Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Mechanism of Electron Injection and Acceleration in Transrelativistic Reconnection

Electron acceleration during magnetic reconnection is thought to play a key role in time-variable high-energy emission from astrophysical systems. By means of particle-in-cell simulations of transrelativistic reconnection, we investigate electron injection and acceleration mechanisms in low-β electron–proton plasmas. We set up a diversity of density and field structures (e.g., X-points and plasmoids) by varying the guide field strength and choosing whether to trigger reconnection or let it spontaneously evolve. We show that the number of X-points and plasmoids controls the efficiency of electron acceleration, with more X-points leading to a higher efficiency. Using on-the-fly acceleration diagnostics, we also show that the nonideal electric fields associated with X-points play a critical role in the first stages of electron acceleration. As a further diagnostic, we include two populations of test particles that selectively experience only certain components of electric fields. We find that the out-of-plane component of the parallel electric field determines the hardness of the high-energy tail of the electron energy distribution. These results further our understanding of electron acceleration in this regime of magnetic reconnection and have implications for realistic models of black hole accretion flows.

79 ASTRONOMY AND ASTROPHYSICS↗

Two new diagnostics of dark energy

We introduce two new diagnostics of dark energy (DE). The first, Om, is a combination of the Hubble parameter and the cosmological redshift and provides a null test of dark energy being a cosmological constant {lambda}. Namely, if the value of Om(z) is the same at different redshifts, then DE{identical_to}{lambda}, exactly. The slope of Om(z) can differentiate between different models of dark energy even if the value of the matter density is not accurately known. For DE with an unevolving equation of state, a positive slope of Om(z) is suggestive of phantom (w<-1) while a negative slope indicates quintessence (w>-1). The second diagnostic--acceleration probe q--is the mean value of the deceleration parameter over a small redshift range. It can be used to determine the cosmological redshift at which the universe began to accelerate, again without reference to the current value of the matter density. We apply the Om and q diagnostics to the Union data set of type Ia supernovae combined with recent data from the cosmic microwave background (Wilkinson Microwave Anisotropy Probe 5) and baryon acoustic oscillations.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview of the SPring-8 Diagnostics Beamlines

We present an overview of the two SPring-8 diagnostics beamlines, the beamline I (dipole magnet source) and II (insertion device source). At the beamline I, synchrotron radiation (SR) in both the X-ray and the visible bands is exploited for characterizations of the electron beam. At the beamline II, by observing the spectral, spatial, and temporal characteristics of X-ray SR of the insertion device (ID), new techniques for accelerator diagnostics are investigated. Irradiation experiments with the ID to develop accelerator components such as photon absorbers, and production of intensive 10 MeV {gamma}-rays by backward Compton scattering of external far infrared (FIR) laser photons are being prepared at the beamline II.

43 PARTICLE ACCELERATORS↗

A Client/Server Architecture for Supporting Science Data Using EPICS Version 4

The Phase 1 grant that serves as a precursor to this proposal, prototyped complex storage techniques for high speed structured data that is being produced in accelerator diagnostics and beam line experiments. It demonstrates the technologies that can be used to archive and retrieve complex data structures and provide the performance required by our new accelerators, instrumentations, and detectors. Phase 2 is proposed to develop a high-performance platform for data acquisition and analysis to provide physicists and operators a better understanding of the beam dynamics. This proposal includes developing a platform for reading 109 MHz data at 10 KHz rates through a multicore front end processor, archiving the data to an archive repository that is then indexed for fast retrieval. The data is then retrieved from this data archive, integrated with the scalar data, to provide data sets to client applications for analysis, use in feedback, and to aid in identifying problem with the instrumentation, plant, beam steering, or model. This development is built on EPICS version 4 , which is being successfully deployed to implement physics applications. Through prior SBIR grants, EPICS version 4 has a solid communication protocol for middle layer services (PVAccess), structured data representation and methods for efficient transportation and access (PVData), an operational hierarchical record environment (JAVA IOC), and prototypes for standard structured data (Normative Types). This work was further developed through project funding to successfully deploy the first service based physics application environment with demonstrated services that provide arbitrary object views, save sets, model, lattice, and unit conversion. Thin client physics applications have been developed in Python that implement quad centering, orbit display, bump control, and slow orbit feedback. This service based architecture has provided a very modular and robust environment that enables commissioning teams to rapidly develop and deploy small scripts that build on powerful services. These services are all built on relational database data stores and scalar data. The work proposed herein, builds on these previous successes to provide data acquisition of high speed data for online analysis clients.

43 PARTICLE ACCELERATORS↗

Modeling of the interaction of a volumetric metallic metamaterial structure with a relativistic electron beam

We present the design of a volumetric metamaterial (MTM) structure and its interaction with a relativistic electron beam. This novel structure has promising applications in particle beam diagnostics, acceleration and microwave generation. The volumetric MTM has a cubic unit cell allowing structures of arbitrary size to be configured as an array of identical cells. This structure allows the exploration of the properties of a metamaterial structure without having to consider substrates or other supporting elements. The dispersion characteristics of the unit cell are obtained using eigenmode simulations in the HFSS code and also using an effective medium theory with spatial dispersion. Good agreement is obtained between these two approaches. The lowest order mode of the MTM structure is found to have a negative group velocity in all directions of propagation. The frequency spectrum of the radiation from a relativistic electron beam passing through the MTM structure is calculated analytically and also calculated with the CST code, with very good agreement. The radiation pattern from the relativistic electron beam is found to be backward Cherenkov radiation, which is a promising tool for particle diagnostics. Calculations are also presented for the application of a MTM-based wakefield accelerator as a possible all-metal replacement for the conventional dielectric wakefield structure. The proposed structure may also be useful for MTM-based vacuum electron devices for microwave generation and amplification.

43 PARTICLE ACCELERATORS↗

Application of the portable diagnostic package to the Wisconsin high-temperature-superconducting axisymmetric mirror (WHAM)

We present an application of the Portable Diagnostic Package (PDP) on the Wisconsin High-temperature-superconducting Axisymmetric Mirror (WHAM), which integrates an optical emission spectroscopy (OES) system and an active Thomson scattering (TS) system. The OES system facilitates a comprehensive impurity line survey and enables flow measurements through the Doppler effect observed on impurity lines. Plasma rotation profiles were successfully derived from doubly charged carbon lines. The TS system enabled the first measurements of the electron temperature in commissioning plasmas on WHAM. Notably, the PDP was installed, commissioned, and used to obtain OES and TS data within ∼6 months from project start, enabled by its designed portability and standardized interfaces. These results demonstrate the PDP’s potential to accelerate diagnostic readiness and advance experimental plasma studies.

Doppler effect↗

The LCLS Timing Event System

The Linac Coherent Light Source requires precision timing trigger signals for various accelerator diagnostics and controls at SLAC-NAL. A new timing system has been developed that meets these requirements. This system is based on COTS hardware with a mixture of custom-designed units. An added challenge has been the requirement that the LCLS Timing System must co-exist and 'know' about the existing SLC Timing System. This paper describes the architecture, construction and performance of the LCLS timing event system.

43 PARTICLE ACCELERATORS↗

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CryoET reveals organelle phenotypes in huntington disease patient iPSC-derived and mouse primary neurons

Huntington’s disease (HD) is caused by an expanded CAG repeat in the huntingtin gene, yielding a Huntingtin protein with an expanded polyglutamine tract. While experiments with patient-derived induced pluripotent stem cells (iPSCs) can help understand disease, defining pathological biomarkers remains challenging. Here, we used cryogenic electron tomography to visualize neurites in HD patient iPSC-derived neurons with varying CAG repeats, and primary cortical neurons from BACHD, deltaN17-BACHD, and wild-type mice. In HD models, we discovered sheet aggregates in double membrane-bound organelles, and mitochondria with distorted cristae and enlarged granules, likely mitochondrial RNA granules. We used artificial intelligence to quantify mitochondrial granules, and proteomics experiments reveal differential protein content in isolated HD mitochondria. Knockdown of Protein Inhibitor of Activated STAT1 ameliorated aberrant phenotypes in iPSC- and BACHD neurons. We show that integrated ultrastructural and proteomic approaches may uncover early HD phenotypes to accelerate diagnostics and the development of targeted therapeutics for HD.

59 BASIC BIOLOGICAL SCIENCES↗

Nonlinear plasma experiments in geospace with gigawatts of RF power at HAARP

The ionosphere is the ionized uppermost layer of our atmosphere (from 70 – 500 km altitude) where free electron densities yield peak critical frequencies in the HF (3 – 30 MHz) range. The ionosphere thus provides a quiescent plasma target, stable on timescales of minutes, for a whole host of active plasma experiments. High power RF experiments on ionospheric plasma conducted in the U.S. have been reported since 1970. The largest HF transmitter built to date is the HAARP phased-array HF transmitter near Gakona, Alaska which can deliver up to 3.6 Gigawatts (ERP) of CW RF power in the range of 2.8 – 10 MHz to the ionosphere with microsecond pointing, power modulation, and frequency agility. With an ionospheric background thermal energy in the range of only 0.1 eV, this amount of power gives access to the highest regimes of the nonlinearity (RF intensity to thermal pressure) ratio. HAARP’s unique features have enabled the conduct of a number of unique nonlinear plasma experiments in the interaction region of overdense ionospheric plasma including generation of artificial aurorae, artificial ionization layers, VLF wave-particle interactions in the magnetosphere, parametric instabilities, stimulated electromagnetic emissions (SEE), strong Langmuir turbulence (SLT) and suprathermal electron acceleration. Diagnostics include the Modular UHF Ionospheric Radar (MUIR) sited at HAARP, the SuperDARN-Kodiak HF radar, spacecraft radio beacons, HF receivers to record stimulated electromagnetic emissions (SEE) and telescopes and cameras for optical emissions. We report on short timescale ponderomotive overshoot effects, artificial field-aligned irregularities (AFAI), the aspect angle dependence of the intensity of the HF-enhanced plasma line, and production of suprathermal electrons. One of the primary missions of HAARP, has been the generation of ELF (300 – 3000 Hz) and VLF (3 – 30 kHz) radio waves which are guided to global distances in the Earth-ionosphere waveguide. We review recent efforts to improve the efficiency of the generation ELF/VLF and develop alternative mechanisms that do not require a natural ionospheric current. Applications include the controlled study of ionospheric irregularities affecting spacecraft communication and navigation systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optics-on-a-chip for ultrafast manipulation of 350-MHz hard x-ray pulses

Microelectromechanical systems (MEMS) are miniature devices integrated into a vast range of industrial and consumer applications. Optical MEMS are developed for dynamic spatiotemporal control in lightwave manipulation and communication as modulators, switches, multiplexers, spectrometer, etc. However, they have not been shown to function similarly in sub-nm wavelength regimes, namely, with hard x-rays, as high-brilliance pulsed x-rays have proven powerful for addressing challenges in time-domain science, from energy conversion to neurobiological control. While desirable temporal properties of x-ray pulses can be enhanced by optics, conventional x-ray optics are inherently massive in size, hence, never dynamic. We demonstrate highly ultrafast x-ray optics-on-a-chip based on MEMS capable of modulating hard x-ray pulses exceeding 350 MHz, 10 3 × higher than any other mechanical modulator, with a pulse purity >10 6 without compromising the spectral brilliance. Moreover, the timing characteristics of the devices can be tuned on-the-fly to deliver optimal pulse properties to create a host of dynamic x-ray instruments and applications, impossible with traditional optics of 10 9 × bulkier and more massive. The advent of the ultrafast optics-on-a-chip heralds a new paradigm of x-ray photonics, time-domain science, and accelerator diagnostics, especially at not only the future-generation light sources that offer coherent and high-frequency pulses but also lab-based facilities that normally do not offer timing structures.

42 ENGINEERING↗

Coherent Optical Transition Radiation Imaging for Laser-Driven Plasma Accelerator Electron-Beam Diagnostics

Application of coherent optical transition radiation (COTR) diagnostics to compact accelerators has been demonstrated for the laser-driven wake field accelerator (LWFA) case recently. It is proposed that such diagnostics for beam size, beam divergence, microbunching fraction, spectral content, and bunch length would be useful before and after any subsequent acceleration in crystals or nanostructures. In addition, there are indications that under some scenarios a microbunched beam could resonantly excite wake fields in nanostructures that might lead to an increased acceleration gradient.

43 PARTICLE ACCELERATORS↗

First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks

At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.

43 PARTICLE ACCELERATORS↗

Computational diagnostics for flame acceleration and transition to detonation in a hydrogen/air mixture

A new computational diagnostic method for pressure-induced compressibility is proposed by projecting its local contribution to the chemical explosive mode (CEM) in the chemical explosive mode analysis (CEMA) framework. The new method is validated for the study of detonation development during the deflagration-to-detonation transition (DDT) process. The flame characteristics are identified through the quantification of individual CEM contributions of chemical reaction, diffusion, and pressure-induced compressibility. Numerical simulations are performed to investigate the DDT processes in a stoichiometric hydrogen-air mixture. A Godunov algorithm, fifth-order in space, and third-order in time are used to solve the fully compressible Navier-Stokes equations on a dynamically adapting mesh. A single-step, calibrated chemical diffusive model (CDM) described by Arrhenius kinetics is used for energy release and conservation between the fuel and the product. The new diagnostic method is first applied to onedimensional (1D) canonical flame configurations followed by two-dimensional (2D) simulations of DDT in an obstructed channel where different detonation initiation scenarios are examined using the new CEMA projection formulation. Detailed examinations of the idealized configuration of detonation initiation through shock focusing mechanism at a flame front are also studied using the new formulation. A comparison of the currently proposed CEMA projection and the original formulation by the authors suggests that including the pressure-induced compressibility is essential for the use of CEMA in DDT process. The results also show that the new formulation of CEMA projection can successively capture the detonation initiation through either a gradient mechanism or a direct initiation mechanism, and therefore can be used as an effective local analytical tool for the computational diagnostics of detonation initiation in a DDT process. It was found that detonation development is characterized by a strong contribution of chemistry role to the CEM which is pivotal to the initiation of detonation. The role of compressibility is found enhanced at the edge of the detonation front where diffusion was found to have minimal effects on detonation development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grating-based deflecting, focusing, and diagnostic dielectric laser accelerator structures

Recent technological advances has made possible the realization of the first laser-driven particle accelerator structure to be fabricated lithographically. However, a complete particle accelerator requires more than just accelerating elements. In this paper, we present a grating-based design for three other quintessential accelerator elements: the focusing structure, the deflecting structure, and the diagnostic structure.

43 PARTICLE ACCELERATORS↗

UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC

to couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision. The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.

43 PARTICLE ACCELERATORS↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗