At least 37 records · Page 2

Determining Calibration Constants for Attitude Measurements

Algorithm based on method of least squares determines calibration constants of seismic instruments for precise attitude measurements. Algorithm programed and run successfully on commercially available desk-top computer. Simplifies determinations of accelerometer calibration constants, and used in field to verify accelerometer stability.

Tcheng, P.↗

Environmental design criteria

Wind velocities at 140-200 km altitude were observed by a Low-G Accelerometer Calibration System (LOGACS) flown on an Agena satellite during a geomagnetic storm. An interesting wind reversal observed by the satellite at auroral latitudes is satisfactorily explained by the neutral air motion caused by the E x B drift deduced from the ground-based geomagnetic data recorded at stations near the meridian of the satellite orbit.

Wu, S. T.↗

An analysis of the upper atmospheric wind observed by LOGACS

Wind velocities at 140 to 200 km altitude were observed by a low-g accelerometer calibration system (LOGACS) flown on an Agena satellite during a geomagnetic storm. An interesting wind reversal observed by the satellite at auroral latitudes is satisfactorily explained by the neutral air motion caused by the E x B drift deduced from the ground-based geomagnetic data recorded at stations near the meridian of the satellite orbit.

Wu, S. T.↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Magnetospheric Multiscale (MMS) Mission Attitude Ground System Design

This paper presents an overview of the attitude ground system (AGS) currently under development for the Magnetospheric Multiscale (MMS) mission. The primary responsibilities for the MMS AGS are definitive attitude determination, validation of the onboard attitude filter, and computation of certain parameters needed to improve maneuver performance. For these purposes, the ground support utilities include attitude and rate estimation for validation of the onboard estimates, sensor calibration, inertia tensor calibration, accelerometer bias estimation, center of mass estimation, and production of a definitive attitude history for use by the science teams. Much of the AGS functionality already exists in utilities used at NASA's Goddard Space Flight Center with support heritage from many other missions, but new utilities are being created specifically for the MMS mission, such as for the inertia tensor, accelerometer bias, and center of mass estimation. Algorithms and test results for all the major AGS subsystems are presented here.

Sedlak, Joseph E.↗

Flight calibration assessment of HiRAP accelerometer data

A flight derived method of calibrating the High Resolution Accelerometer Package (HiRAP) flight data has been developed and is discussed for Shuttle Orbiter missions STS-35 and STS-40. These two mission data sets have been analyzed using ground calibration factors and flight derived calibration factors. This flight technique evolved early in the flight program when it was recognized that ground calibration factors are insufficient to determine absolute low-acceleration levels. The application of flight calibration factors to the data sets from these missions produced calibrated acceleration levels within an accuracy of less than +/- 1.5 microgravity of zero during a time in the flight when the acceleration level was known to be less than 1.0 microgravity. This analysis further confirms the theory that flight calibrations are required in order to obtain the absolute measurement of low-frequency, low-acceleration flight signals.

Blanchard, Robert C.↗

Accuracy improvement in a calibration test bench for accelerometers by a vision system

A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ground and flight calibration assessment of HiRAP accelerometer data from missions STS-35 and STS-40

A method of removing non-aerodynamic signals and calibrating the High Resolution Accelerometer Package (HiRAP) flight data was developed and is discussed for Shuttle Orbiter missions STS-35 and STS-40. These two mission data sets were analyzed using ground (dynamic) calibration data and flight calibrations using a flight calibration technique that was developed and refined over the HiRAP operational lifetime. This technique evolved early in the flight program, since it was recognized that ground calibration factors are insufficient to determine absolute low acceleration levels. The application of flight calibration factors to the data sets from these missions produced calibrated acceleration levels within an accuracy of less than plus or minus 1.5 micro-g of zero during a time in the flight when the acceleration level was known to be less than 1 micro-g. This analysis further confirms the theory that flight calibrations are required in order to obtain the absolute measurement of low-frequency, low-acceleration flight signals.

Blanchard, Robert C.↗

GRACE KBR and Accelerometer Data Reduction and Calibration

The Gravity Recovery and Climate Experiment (GRACE), launched on March 17, 2002, represents the state-of-the-art in geodetic observations of the static and time varying components of the Earth's geopotential field. The fundamental measurement used to observe gravity is the inter-satellite range and range rate between two coplanar, low altitude satellites obtained from a K-band ranging (KBR) system. In addition to the K-band ranging system, each satellite possess a Super-STAR Accelerometer, a GPS receiver/antenna package, Star Cameras and a Laser Retro Reflector (LRR) to complete the compliment of science instruments. The GRACE project has now released two years of Level 1B data derived from the science instruments and sensors. An integral component of our time variable gravity research is the reduction, calibration and analyses of these Level 1B data. In particular we have analyzed several months of K-band ranging (KBR1B), accelerometry (ACC1B) and GPS navigation (GNAV1B) data. Accelerometer calibration and KBR data reduction methodology and results will be presented. We discuss the impact of these analyses on the recovery of time variable gravity.

Rowlands, David D.↗

Microcantilevers with embedded accelerometers for dynamic atomic force microscopy

The measurement of the intermittent interaction between an oscillating nanotip and the sample surface is a key challenge in dynamic Atomic Force Microscopy (AFM). Accelerometers integrated onto AFM cantilevers can directly measure this interaction with minimal cantilever modification but have been difficult to realize. Here, we design and fabricate high frequency bandwidth accelerometers on AFM cantilevers to directly measure the tip acceleration in commercial AFM systems. We demonstrate a simple way of calibrating such accelerometers and present experiments using amplitude modulated AFM on freshly cleaved mica samples in water to study the response of the accelerometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements to Calibration Modeling of a Tri-Axial Accelerometer Using Response Surface Methods

Aerodynamic ground test facilities require precision attitude measurements to support fundamental research and aerodynamic vehicle characterization. Accelerometers are used as one solution for measuring test article attitude. Several wind-tunnel facilities experience elevated temperatures during sustained testing of approximately 38°C (100°F) and extremes up to 149°C (300°F). Accelerometer thermal corrections are required to maintain attitude measurement accuracy during elevated temperature tunnel conditions. This manuscript details characterization of non-linear and thermal effects of the Mini/MEMs Tri-Axis Sensor System (MTASS) developed at NASA. Non-linear effects are characterized using a two-axis index head, and temperature effects are characterized using a metallic cube in a thermal chamber. The results show a significant decrease in back-computed residuals for room temperature and elevated temperatures experiments.

Accelerometer↗

Improvements to Calibration Modeling of a Tri-Axial Accelerometer Using Response Surface Methods

Aerodynamic ground test facilities require precision attitude measurements to support fundamental research and aerodynamic vehicle characterization. Accelerometers are used as one solution for measuring test article attitude. Several wind-tunnel facilities experience elevated temperatures during sustained testing of approximately 38°C (100°F) and extremes up to 149°C (300°F). Accelerometer thermal corrections are required to maintain attitude measurement accuracy during elevated temperature tunnel conditions. This manuscript details characterization of non-linear and thermal effects of the Mini/MEMs Tri-Axis Sensor System (MTASS) developed at NASA. Non-linear effects are characterized using a two-axis index head, and temperature effects are characterized using a metallic cube in a thermal chamber. The results show a significant decrease in back-computed residuals for room temperature and elevated temperatures experiments.

Accelerometer↗

Absolute calibration method for nanosecond-resolved, time-streaked, fiber optic light collection, spectroscopy systems

This paper describes a convenient and accurate method to calibrate fast (<1 ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such systems are inherently difficult to calibrate due to the lack of sufficiently intense, calibrated light sources. Such a system is used to collect spectral data on plasmas generated in electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA) at Sandia National Laboratories. On RITS, plasma light is collected through a small diameter (200 {mu}m) optical fiber and recorded on a fast streak camera at the output of a 1 meter Czerny-Turner monochromator. For this paper, a 300 W xenon short arc lamp (Oriel Model 6258) was used as the calibration source. Since the radiance of the xenon arc varies from cathode to anode, just the area around the tip of the cathode ('hotspot') was imaged onto the fiber, to produce the highest intensity output. To compensate for chromatic aberrations, the signal was optimized at each wavelength measured. Output power was measured using 10 nm bandpass interference filters and a calibrated photodetector. These measurements give power at discrete wavelengths across the spectrum, and when linearly interpolated, provide a calibration curve for the lamp. The shape of the spectrum is determined by the collective response of the optics, monochromator, and streak tube across the spectral region of interest. The ratio of the spectral curve to the measured bandpass filter curve at each wavelength produces a correction factor (Q) curve. This curve is then applied to the experimental data and the resultant spectra are given in absolute intensity units (photons/sec/cm{sup 2}/steradian/nm). Error analysis shows this method to be accurate to within +/- 20%, which represents a high level of accuracy for this type of measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗