Search NASA⌕ Search

SEARCH · Search NASA

Results for “active coded aperture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Nuclear imaging to diagnose and correct target-driver registration at high-repetition-rate for improved reactor efficiency

Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Sonic Boom Control

A theory and simulation code are developed to study nonsteady sources as means to control sonic booms of supersonic aircraft. A key result is that the source of sonic boom pressure is not confined to the length of the aircraft but occupies an extensive segment of flight path. An aircraft in nonsteady flight functions as a synthetic aperture antenna, generating complex acoustic waves with no simple relation to instantaneous volume or lift distributions. The theory applies linear acoustics to slender nonsteady sources but requires no far field approximation. The solution for pressure contains a term not seen in Whitham's theory for sonic booms of distant supersonic aircraft. The term describes a pressure field that decays algebraically behind the Mach cone and, in the case of steady flight, integrates to a ground load equal to the weight of the aircraft. The algebraic term is separate from those that describe the sonic boom. Two nonsteady source phenomena are evaluated: periodic velocity changes (surge), and periodic longitudinal lift redistribution (slosh). Surge can attenuate a sonic boom and convert it into prolonged weak reverberation, but accelerations needed to produce the phenomenon seem too large for practical use. Slosh may be practical and can alter sonic booms but does not, on the average, result in boom attenuation. The conclusion is that active sonic boom abatement is possible in theory but maybe not practical

Crow, Steven C.↗

Pitfalls of tungsten multileaf collimator in proton beam therapy

Purpose: Particle beam therapy is associated with significant startup and operational cost. Multileaf collimator (MLC) provides an attractive option to improve the efficiency and reduce the treatment cost. A direct transfer of the MLC technology from external beam radiation therapy is intuitively straightforward to proton therapy. However, activation, neutron production, and the associated secondary cancer risk in proton beam should be an important consideration which is evaluated. Methods: Monte Carlo simulation with FLUKA particle transport code was applied in this study for a number of treatment models. The authors have performed a detailed study of the neutron generation, ambient dose equivalent [H*(10)], and activation of a typical tungsten MLC and compared with those obtained from a brass aperture used in a typical proton therapy system. Brass aperture and tungsten MLC were modeled by absorber blocks in this study, representing worst-case scenario of a fully closed collimator. Results: With a tungsten MLC, the secondary neutron dose to the patient is at least 1.5 times higher than that from a brass aperture. The H*(10) from a tungsten MLC at 10 cm downstream is about 22.3 mSv/Gy delivered to water phantom by noncollimated 200 MeV beam of 20 cm diameter compared to 14 mSv/Gy for the brass aperture. For a 30-fraction treatment course, the activity per unit volume in brass aperture reaches 5.3 x 10{sup 4} Bq cm{sup -3} at the end of the last treatment. The activity in brass decreases by a factor of 380 after 24 h, additional 6.2 times after 40 days of cooling, and is reduced to background level after 1 yr. Initial activity in tungsten after 30 days of treating 30 patients per day is about 3.4 times higher than in brass that decreases only by a factor of 2 after 40 days and accumulates to 1.2 x 10{sup 6} Bq cm{sup -3} after a full year of operation. The daily utilization of the MLC leads to buildup of activity with time. The overall activity continues to increase due to {sup 179}Ta with a half-life of 1.82 yr and thus require prolonged storage for activity cooling. The H*(10) near the patient side of the tungsten block is about 100 {mu}Sv/h and is 27 times higher at the upstream side of the block. This would lead to an accumulated dose for therapists in a year that may exceed occupational maximum permissible dose (50 mSv/yr). The value of H*(10) at the upstream surface of the tungsten block is about 220 times higher than that of the brass. Conclusions: MLC is an efficient way for beam shaping and overall cost reduction device in proton therapy. However, based on this study, tungsten seems to be not an optimal material for MLC in proton beam therapy. Usage of tungsten MLC in clinic may create unnecessary risks associated with the secondary neutrons and induced radioactivity for patients and staff depending on the patient load. A careful selection of material for manufacturing of an optimal MLC for proton therapy is thus desired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space astrophysics with large structures - CASES and P/OF

Space instruments for remote sensing, of the types used for astrophysics and solar-terrestrial physics among many disciplines, will grow to larger physical sizes in the future. The zero-g space environment does not inherently restrict such growth, because relatively lightweight structures can be used. Active servo control of the structures can greatly increase their size for a given mass. The Pinhole/Occulter Facility, a candidate Space Station attached payload, offers an example: it will achieve 0.2 arc s resolution by use of a 50-m baseline for coded-aperture telescopes for hard X-ray and gamma-ray imagers.

Hudson, Hugh S.↗

Spectra and angular distributions of atmospheric gamma rays from 0.3 to 10 MeV at lambda = 40 deg

Measurements of the spectral and angular distributions of atmospheric gamma sq cm rays in the energy range 0.3-10 MeV over Palestine, Texas, at residual depths of 2.5 and 70 g/sq cm are reported. In confirmation of the general features of a model prediction, the measurements show at 2.5 g/sq cm upward moving fluxes greater than the downward moving fluxes, the effect increasing with energy, and approximate isotropy at 70 g/sq cm. Numerous characteristic gamma-ray lines were observed, most prominently at 0.511, 1.6, 2.3, 4.4, and 6.1 MeV. Their intensities were also compared with model predictions. Observations were made with an actively shielded scintillator counter with two detectors, one of aperture 50 deg FWHM and the other of 120 deg FWHM. Above 1 MeV, contributions to the counting rate from photons penetrating the shield annulus and from neutron interactions were large; they were studied by means of a Monte Carlo code and are extensively discussed.

Ling, J. C.↗

ITER Generic Diagnostic Upper Port Plug Nuclear Heating and Personnel Dose Rate Assesment Neutronics Analysis using the ATTILA Discrete Ordinates Code

Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of the ECH heating system were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture (ECH). The neutronics discrete-ordinates code ATTILA® and SEVERIAN® (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from the ITER “Brand Model” MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and ECH cases. The ECH or Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 μSv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 μSv/hr but fell below the limit to 90 μSv/hr 2-weeks later. The Large Aperture or ECH style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 μSv/hr but was still at 120 μSv/hr 4-weeks later. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COSMIC monthly progress report

Activities of the Computer Software Management and Information Center (COSMIC) are summarized for the month of August, 1993. Tables showing the current inventory of programs available from COSMIC are presented and program processing and evaluation activities are discussed. Ten articles were prepared for publication in the NASA Tech Brief Journal. These articles (included in this report) describe the following software items: (1) MOM3D - A Method of Moments Code for Electromagnetic Scattering (UNIX Version); (2) EM-Animate - Computer Program for Displaying and Animating the Steady-State Time-Harmonic Electromagnetic Near Field and Surface-Current Solutions; (3) MOM3D - A Method of Moments Code for Electromagnetic Scattering (IBM PC Version); (4) M414 - MIL-STD-414 Variable Sampling Procedures Computer Program; (5) MEDOF - Minimum Euclidean Distance Optimal Filter; (6) CLIPS 6.0 - C Language Integrated Production System, Version 6.0 (Macintosh Version); (7) CLIPS 6.0 - C Language Integrated Production System, Version 6.0 (IBM PC Version); (8) CLIPS 6.0 - C Language Integrated Production System, Version 6.0 (UNIX Version); (9) CLIPS 6.0 - C Language Integrated Production System, Version 6.0 (DEC VAX VMS Version); and (10) TFSSRA - Thick Frequency Selective Surface with Rectangular Apertures. Activities in the areas of marketing, customer service, benefits identification, maintenance and support, and dissemination are also described along with a budget summary.

Source record↗

Radiological Survey of Contaminated Installations of Research Reactor before Dismantling in High Dose Conditions with Complex for Remote Measurements of Radioactivity - 12069

Decontamination and decommissioning of the research reactors MR (Testing Reactor) and RFT (Reactor of Physics and Technology) has recently been initiated in the National Research Center (NRC) 'Kurchatov institute', Moscow. These research reactors have a long history and many installations - nine loop facilities for experiments with different kinds of fuel. When decommissioning nuclear facilities it is necessary to measure the distribution of radioactive contamination in the rooms and at the equipment at high levels of background radiation. At 'Kurchatov Institute' some special remote control measuring systems were developed and they are applied during dismantling of the reactors MR and RFT. For a survey of high-level objects a radiometric system mounted on the robotic Brokk vehicle is used. This system has two (4π and collimated) dose meters and a high resolution video camera. Maximum measured dose rate for this system is ∼8.5 Sv/h. To determine the composition of contaminants, a portable spectrometric system is used. It is a remotely controlled, collimated detector for scanning the distribution of radioactive contamination. To obtain a detailed distribution of contamination a remote-controlled gamma camera is applied. For work at highly contaminated premises with non-uniform background radiation, another camera is equipped with rotating coded mask (coded aperture imaging). As a result, a new system of instruments for remote radioactivity measurements with wide range of sensitivity and angular resolution was developed. The experience and results of measurements in different areas of the reactor and at its loop installations, with emphasis on the radioactive survey of highly-contaminated samples, are presented. These activities are conducted under the Federal Program for Nuclear and Radiation Safety of Russia. Adaptation of complex remote measurements of radioactivity and survey of contaminated installations of research reactor before dismantling in high dose conditions has proven successful. The radioactivity measuring devices for operation at high, non-uniform dose background were tested in the field and a new data of measurement of contamination distribution in the premises and installations were obtained. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

Development of Diamond Membrane-Based X-Ray Optics: Fresnel Zone Plates, Beam Stops, and Grids

This project was proposed to develop the design and fabrication of zone plates for hard X-ray focusing up to 25 keV photon energies with 20 nm resolution (with zone doubling), based on diamond membranes. The benefits of using diamond are: improved mechanical robustness which among other advantages prevents collapse of high-aspect-ratio ring structures, a known high-aspect-ratio etch method, and excellent compatibility with other processes, excellent radiation hardness, extremely low X-ray absorption, and significantly improved thermal/dimensional stability as compared to alternative materials. The Phase I findings enable Phase II goals as well as significant progress in other diamond-membrane devices, such as diamond-supported X-ray optics (beam stops, apertures, phase shift disks for phase contrast X-ray microscopy, grids, resolution targets, coded apertures for coherence measurements, etc), X-ray windows and membrane–based detectors. Zone plates with outermost zones of 60 nm were written in 500 nm electron resist and transferred to a depth of up to 1.8 mm (exceeding the expectations) into a stack of engineered multilayer ultra-nano-crystalline diamond alternating non-conductive and conductive layers. The active material for focusing was added on top (Au and Ir). Several processes were investigated and validated to enable in Phase II the enhancement of the thickness of the structures, including polishing the over-plated zone plates and growing diamond on top of Ir-coated zone plates without the destruction of the nanostructures underneath. The zone plates were geometrically characterized.

07 ISOTOPE AND RADIATION SOURCES↗

The Advanced Solar Observatory

A conceptual plan for the development of a comprehensive long duration solar space observatory, The Advanced Solar Observatory (ASO) is described. The ASO is intended to provide solar astronomers with the observational power necessary to address fundamental problems relating to the solar convection zone and activity cycle; the thermal and nonthermal processes that control the transport of energy, mass, and magnetic flux in the solar atmosphere; the generation of the solar wind; and the dynamics of the inner heliosphere. The ASO concept encompasses three proposed Space Station-based instrument ensembles: (1) the High Resolution Telescope Cluster, which includes far ultraviolet, extreme ultraviolet, and X-ray telescopes; (2) the Pinhole/Occulter Facility, which includes Fourier transform and coded aperture hard X-ray and gamma ray telescopes and occulted ultraviolet and visible light coronagraphs; and (3) the High Energy Facility, which contains neutron, gamma ray, and low frequency radio spectrometers. Two other facilities, the Orbiting Solar Laboratory, and a package of Global Dynamics Instrumentation, will, with the Space Station ensembles, form a comprehensive capability for solar physics. The scientific program of the ASO, current instrument concepts for the Space Station based ASO instrument ensembles, and plans for their accommodation on the Space Station are described.

Walker, Arthur B. C., Jr.↗

Possibilities of improving the performance of an autonomous cw chemical DF laser by replacing the slot nozzles by the ramp ones in the nozzle array

The results of a comparative numerical study of the performance of an autonomous cw chemical DF laser are obtained by simulating the processes in the nozzles and laser cavity where several configurations of slot and ramp nozzle arrays are employed. Three-dimensional Navier-Stokes equations solved with the Ansys CFX software are used to describe the reacting multicomponent flow in the nozzles and laser cavity. To investigate lasing characteristics, a supplementary code is developed and is used to calculate the radiation intensity in the Fabry-Perot resonator, taking into account its nonuniform distribution along the aperture width and height. It is shown that the use of the nozzle array consisting of ramp nozzles, which, in contrast to the slot nozzles, provide enhanced mixing of the reactants makes it possible to improve the laser performance in the case of a high-pressure (more than 15 Torr) active medium. (control of radiation parameters)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TOUGH-UDEC: A simulator for coupled multiphase fluid flows, heat transfers and discontinuous deformations in fractured porous media

A numerical simulator entitled TOUGH-UDEC is presented for the assessment of coupled thermal-hydraulic-mechanical processes in fractured porous media. Two existing well-established codes, TOUGH2 and UDEC, are coupled to model multiphase fluid flows, heat transfers, and discontinuous deformations in fractured porous media by means of discrete fracture representation. TOUGH2 is widely used for the modeling of heat transfers and multiphase multicomponent fluid flows, and UDEC is a well-known distinct element code for rock mechanics. The two codes are solved sequentially, with coupling parameters passed to each equation at specific intervals. After solving thermal-hydraulic equations within the TOUGH2 code, pressure and temperature information is imported into the UDEC model. Upon solving the mechanical equation within the UDEC code the calculated fracture apertures are converted to the equivalent permeability and porosity values for a TOUGH2 flow analysis. The solution is calculated by iteratively following an explicit sequence for numerical efficiency. Verifications are presented to demonstrate the capabilities of the coupled TOUGH-UDEC simulator. Three application examples of (1) shear dilation due to increased pore pressure, (2) thermal stress and (3) CO 2 injection, show that the new simulator can be an effective tool for geoengineering applications involving shear activation of fractures and faults.

54 ENVIRONMENTAL SCIENCES↗

A rate equation approach to gain saturation effects in laser mode calculations

Space exploration and research require large amounts of power. Solar pumped laser systems have been shown to have the potential for meeting the performance requirements necessary for power transmission in space. The successful design of laser systems for these applications will depend, in part, on having a clear understanding of the development of the dynamical processes in the laser cavity and on the effects that changes in physical and design parameters have on laser performance. In particular, it is necessary to know the amplitude and phase distributions of the laser beam at the output aperture when steady state operation is achieved in order to determine the far-field power distribution. The output from the laser will depend on the active medium, the optical environment of the active material and on the gain distribution in the active region as laser action builds up and reaches steady state. An important component in the design process will be a realistic model of the active laser cavity. A computer model of the laser cavity, based on Huygens' principle was developed. The code calculates the amplitude and phase of an optical wave reflected back and forth between the mirrors of a laser cavity. The original code assumes a gain distribution which does not change with the buildup of oscillations in the cavity. A step in the direction of realism is the inclusion of a saturable gain medium in the cavity. The objective is to incorporate saturation effects into the existing computer model.

Roberts, Lila F.↗

Oil Spill Thickness Determination from L-band Synthetic Aperture Radar

Efficient and effective oil spill response requires accurate information regarding slick location, extent, and thickness to direct remediation activities. Of these three, the most challenging to determine is thickness. Ideally, the needed information would be provided by remote sensing instruments, particularly those operating from space. In this study we consider the capability of L-band synthetic aperture radar (SAR) for identifying oil layer thickness for slicks in open water given the range of oil properties and environmental conditions typical in this setting. The goal is to determine layer thickness with precision equivalent to that of the Bonn Agreement Oil Appearance Code. Here we report preliminary results of an ongoing study to determine whether either relative or absolute slick thickness can be determined from L-band SAR. The study has an experimental component, which uses low noise airborne SAR data acquired over slicks to evaluate the capability to determine relative thickness, i.e., to differentiate sheen from zones of varying thicker oil within a slick. The component of the study to evaluate whether absolute thickness can be determined from SAR uses backscatter simulations within a physics- based model of electromagnetic scattering from slicked and unslicked ocean surfaces accounting for oil properties, meteorological conditions, and sea state. As part of the theoretical component of the study, we evaluate the backscatter sensitivity to oil characteristics to determine which properties most influenced the SAR measurements. These results are used to determine whether the oil-to-water ratio or the oil thickness can be quantified with reasonable accuracy based upon SAR backscatter intensities alone or whether it requires calibration to go from relative to absolute thickness. The ratio of the backscatter contrast between clean and slicked ocean surfaces is shown to be sensitive to variations within slicks that well correlate with the oil layer thickness. Determination of absolute thickness is much more challenging given the variation of oil properties as the oil weathers on the sea surface.

Holt, Benjamin↗

A LOCAL BASELINE OF THE BLACK HOLE MASS SCALING RELATIONS FOR ACTIVE GALAXIES. I. METHODOLOGY AND RESULTS OF PILOT STUDY

We present high-quality Keck/LRIS long-slit spectroscopy of a pilot sample of 25 local active galaxies selected from the SDSS (0.02 {<=}z {<=} 0.1; M{sub BH}>10{sup 7} M{sub sun}) to study the relations between black hole mass (M{sub BH}) and host-galaxy properties. We determine stellar kinematics of the host galaxy, deriving stellar-velocity dispersion profiles and rotation curves from three spectral regions (including CaH and K, MgIb triplet, and Ca II triplet). In addition, we perform surface photometry on SDSS images, using a newly developed code for joint multi-band analysis. BH masses are estimated from the width of the H{beta} emission line and the host-galaxy free 5100 A active galactic nucleus (AGN) luminosity. Combining results from spectroscopy and imaging allows us to study four M{sub BH} scaling relations: M{sub BH}-{sigma}, M{sub BH}-L{sub sph}, M{sub BH}-M{sub sph,*}, and M{sub BH}-M{sub sph,dyn}. We find the following results. First, stellar-velocity dispersions determined from aperture spectra (e.g., SDSS fiber spectra or unresolved data from distant galaxies) can be biased, depending on aperture size, AGN contamination, and host-galaxy morphology. However, such a bias cannot explain the offset seen in the M{sub BH}-{sigma} relation at higher redshifts. Second, while the CaT region is the cleanest to determine stellar-velocity dispersions, both the MgIb region, corrected for Fe II emission, and the CaHK region, although often swamped by the AGN power-law continuum and emission lines, can give results accurate to within a few percent. Third, the M{sub BH} scaling relations of our pilot sample agree in slope and scatter with those of other local active and inactive galaxies. In the next papers of the series we will quantify the scaling relations, exploiting the full sample of {approx}100 objects.

79 ASTRONOMY AND ASTROPHYSICS↗