Search NASA⌕ Search

SEARCH · Search NASA

Results for “active coded aperture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

36 records · Page 2

Radiological Survey of Contaminated Installations of Research Reactor before Dismantling in High Dose Conditions with Complex for Remote Measurements of Radioactivity - 12069

Decontamination and decommissioning of the research reactors MR (Testing Reactor) and RFT (Reactor of Physics and Technology) has recently been initiated in the National Research Center (NRC) 'Kurchatov institute', Moscow. These research reactors have a long history and many installations - nine loop facilities for experiments with different kinds of fuel. When decommissioning nuclear facilities it is necessary to measure the distribution of radioactive contamination in the rooms and at the equipment at high levels of background radiation. At 'Kurchatov Institute' some special remote control measuring systems were developed and they are applied during dismantling of the reactors MR and RFT. For a survey of high-level objects a radiometric system mounted on the robotic Brokk vehicle is used. This system has two (4π and collimated) dose meters and a high resolution video camera. Maximum measured dose rate for this system is ∼8.5 Sv/h. To determine the composition of contaminants, a portable spectrometric system is used. It is a remotely controlled, collimated detector for scanning the distribution of radioactive contamination. To obtain a detailed distribution of contamination a remote-controlled gamma camera is applied. For work at highly contaminated premises with non-uniform background radiation, another camera is equipped with rotating coded mask (coded aperture imaging). As a result, a new system of instruments for remote radioactivity measurements with wide range of sensitivity and angular resolution was developed. The experience and results of measurements in different areas of the reactor and at its loop installations, with emphasis on the radioactive survey of highly-contaminated samples, are presented. These activities are conducted under the Federal Program for Nuclear and Radiation Safety of Russia. Adaptation of complex remote measurements of radioactivity and survey of contaminated installations of research reactor before dismantling in high dose conditions has proven successful. The radioactivity measuring devices for operation at high, non-uniform dose background were tested in the field and a new data of measurement of contamination distribution in the premises and installations were obtained. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

Development of Diamond Membrane-Based X-Ray Optics: Fresnel Zone Plates, Beam Stops, and Grids

This project was proposed to develop the design and fabrication of zone plates for hard X-ray focusing up to 25 keV photon energies with 20 nm resolution (with zone doubling), based on diamond membranes. The benefits of using diamond are: improved mechanical robustness which among other advantages prevents collapse of high-aspect-ratio ring structures, a known high-aspect-ratio etch method, and excellent compatibility with other processes, excellent radiation hardness, extremely low X-ray absorption, and significantly improved thermal/dimensional stability as compared to alternative materials. The Phase I findings enable Phase II goals as well as significant progress in other diamond-membrane devices, such as diamond-supported X-ray optics (beam stops, apertures, phase shift disks for phase contrast X-ray microscopy, grids, resolution targets, coded apertures for coherence measurements, etc), X-ray windows and membrane–based detectors. Zone plates with outermost zones of 60 nm were written in 500 nm electron resist and transferred to a depth of up to 1.8 mm (exceeding the expectations) into a stack of engineered multilayer ultra-nano-crystalline diamond alternating non-conductive and conductive layers. The active material for focusing was added on top (Au and Ir). Several processes were investigated and validated to enable in Phase II the enhancement of the thickness of the structures, including polishing the over-plated zone plates and growing diamond on top of Ir-coated zone plates without the destruction of the nanostructures underneath. The zone plates were geometrically characterized.

07 ISOTOPE AND RADIATION SOURCES↗

Possibilities of improving the performance of an autonomous cw chemical DF laser by replacing the slot nozzles by the ramp ones in the nozzle array

The results of a comparative numerical study of the performance of an autonomous cw chemical DF laser are obtained by simulating the processes in the nozzles and laser cavity where several configurations of slot and ramp nozzle arrays are employed. Three-dimensional Navier-Stokes equations solved with the Ansys CFX software are used to describe the reacting multicomponent flow in the nozzles and laser cavity. To investigate lasing characteristics, a supplementary code is developed and is used to calculate the radiation intensity in the Fabry-Perot resonator, taking into account its nonuniform distribution along the aperture width and height. It is shown that the use of the nozzle array consisting of ramp nozzles, which, in contrast to the slot nozzles, provide enhanced mixing of the reactants makes it possible to improve the laser performance in the case of a high-pressure (more than 15 Torr) active medium. (control of radiation parameters)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TOUGH-UDEC: A simulator for coupled multiphase fluid flows, heat transfers and discontinuous deformations in fractured porous media

A numerical simulator entitled TOUGH-UDEC is presented for the assessment of coupled thermal-hydraulic-mechanical processes in fractured porous media. Two existing well-established codes, TOUGH2 and UDEC, are coupled to model multiphase fluid flows, heat transfers, and discontinuous deformations in fractured porous media by means of discrete fracture representation. TOUGH2 is widely used for the modeling of heat transfers and multiphase multicomponent fluid flows, and UDEC is a well-known distinct element code for rock mechanics. The two codes are solved sequentially, with coupling parameters passed to each equation at specific intervals. After solving thermal-hydraulic equations within the TOUGH2 code, pressure and temperature information is imported into the UDEC model. Upon solving the mechanical equation within the UDEC code the calculated fracture apertures are converted to the equivalent permeability and porosity values for a TOUGH2 flow analysis. The solution is calculated by iteratively following an explicit sequence for numerical efficiency. Verifications are presented to demonstrate the capabilities of the coupled TOUGH-UDEC simulator. Three application examples of (1) shear dilation due to increased pore pressure, (2) thermal stress and (3) CO 2 injection, show that the new simulator can be an effective tool for geoengineering applications involving shear activation of fractures and faults.

54 ENVIRONMENTAL SCIENCES↗

A LOCAL BASELINE OF THE BLACK HOLE MASS SCALING RELATIONS FOR ACTIVE GALAXIES. I. METHODOLOGY AND RESULTS OF PILOT STUDY

We present high-quality Keck/LRIS long-slit spectroscopy of a pilot sample of 25 local active galaxies selected from the SDSS (0.02 {<=}z {<=} 0.1; M{sub BH}>10{sup 7} M{sub sun}) to study the relations between black hole mass (M{sub BH}) and host-galaxy properties. We determine stellar kinematics of the host galaxy, deriving stellar-velocity dispersion profiles and rotation curves from three spectral regions (including CaH and K, MgIb triplet, and Ca II triplet). In addition, we perform surface photometry on SDSS images, using a newly developed code for joint multi-band analysis. BH masses are estimated from the width of the H{beta} emission line and the host-galaxy free 5100 A active galactic nucleus (AGN) luminosity. Combining results from spectroscopy and imaging allows us to study four M{sub BH} scaling relations: M{sub BH}-{sigma}, M{sub BH}-L{sub sph}, M{sub BH}-M{sub sph,*}, and M{sub BH}-M{sub sph,dyn}. We find the following results. First, stellar-velocity dispersions determined from aperture spectra (e.g., SDSS fiber spectra or unresolved data from distant galaxies) can be biased, depending on aperture size, AGN contamination, and host-galaxy morphology. However, such a bias cannot explain the offset seen in the M{sub BH}-{sigma} relation at higher redshifts. Second, while the CaT region is the cleanest to determine stellar-velocity dispersions, both the MgIb region, corrected for Fe II emission, and the CaHK region, although often swamped by the AGN power-law continuum and emission lines, can give results accurate to within a few percent. Third, the M{sub BH} scaling relations of our pilot sample agree in slope and scatter with those of other local active and inactive galaxies. In the next papers of the series we will quantify the scaling relations, exploiting the full sample of {approx}100 objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an unacceptable level of bias.

benchmark problems↗

A survey of imaging systems for materials and objects in containers

Radiation imaging can be useful to evaluate the contents of containers; Passive imaging i.e., gamma sources, neutron sources, hydrogen near to a neutron source. Active imaging i.e., Transmission radiography shows high density material; Neutron coincidences indicate fissionable material; Time of Flight and die-away time are important. These technologies may be most useful in confirming ABSENCE of an item.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80- channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, opensource pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80-channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, open-source pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

Field Harmonic Measurement of High-Gradient Permanent Magnet Quadrupoles for NSLS- II Upgrade

The National Synchrotron Light Source II (NSLS-II) is preparing for a major upgrade based on a new lattice concept, known as “Complex Bend,” to replace its existing double bend achromat (DBA) lattice. Here, this novel lattice will use high-gradient permanent magnet quadrupoles (PMQs) with small apertures in the range of 16–22 mm. A prototype complex bend branch with PMQs has been installed in the NSLS-II linac to evaluate the lattice's performance. An accurate and precise magnetic measurement system is required for field harmonic characterization and magnetic tuning of these PMQs. As part of this project a Rotating-Coil bench, based on a Printed Circuit Board (PCB) coil with a 12 mm diameter, has been configured to measure nine PMQs with bore diameter of 12.7 mm. This PCB coil has an active length of 270 mm, and is able to measure fields up to the 15th harmonic of the main field at a reference radius of 5 mm, while maintaining field quality levels within 10 ppm of the main field. This article presents the PCB coil setup, the harmonic measurement results and their temperature dependencies and repeatability. Simulation results on compensation of undesired multipoles using “IDBuilder”, a genetic algorithm-based optimizer code for magnetic tuning is included for field harmonic corrections.

36 MATERIALS SCIENCE↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Measurements and analysis of dynamic effects in the LARP model quadrupole HQ02b during rapid discharge

This paper presents the analysis of some quench tests addressed to study the dynamic effects in the 1-m-long 120-mm-aperture Nb 3 Sn quadrupole magnet, i.e., HQ02b, designed, fabricated, and tested by the LHC Accelerator Research Program. The magnet has a short sample gradient of 205 T/m at 1.9 K and a peak field of 14.2 T. The test campaign has been performed at CERN in April 2014. In the specific tests, which were dedicated to the measurements of the dynamic inductance of the magnet during the rapid current discharge for a quench, the protection heaters were activated only in some windings, in order to obtain the measure of the resistive and inductive voltages separately. The analysis of the results confirms a very low value of the dynamic inductance at the beginning of the discharge, which later approaches the nominal value. Indications of dynamic inductance variation were already found from the analysis of current decay during quenches in the previous magnets HQ02a and HQ02a2; however, with this dedicated test of HQ02b, a quantitative measurement and assessment has been possible. An analytical model using interfilament coupling current influence for the inductance lowering has been implemented in the quench calculation code QLASA, and the comparison with experimental data is given. In conclusion, the agreement of the model with the experimental results is very good and allows predicting more accurately the critical parameters in quench analysis (MIITs, hot spot temperature) for the MQXF Nb3Sn quadrupoles, which will be installed in the High Luminosity LHC.

43 PARTICLE ACCELERATORS↗

HEXAGONAL ARRAY STRUCTURE FOR 2D NDE APPLICATIONS

This paper describes a combination of simulation and experimentation to evaluate the advantages offered by utilizing a hexagonal shaped array element in a 2D NDE array structure. The active material is a 1-3 connectivity piezoelectric composite structure incorporating triangular shaped pillars--each hexagonal array element comprising six triangular pillars. A combination of PZFlex, COMSOL and Matlab has been used to simulate the behavior of this device microstructure, for operation around 2.25 MHz, with unimodal behavior and low levels of mechanical cross-coupling predicted. Furthermore, the application of hexagonal array elements enables the array aperture to increase by approximately 30%, compared to a conventional orthogonal array matrix and hence will provide enhanced volumetric coverage and SNR. Prototype array configurations demonstrate good corroboration of the theoretically predicted mechanical cross-coupling between adjacent array elements (approx23 dB).

36 MATERIALS SCIENCE↗

Ultrasonic Flaw Detection of Cracks and Machined Flaws as Observed Through Austenitic Stainless Steel Piping Welds

Piping welds in the pressure boundary of light water reactors (LWRs) are subject to a volumetric examination based on Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. Due to access limitations and high background radiation levels, the technique used is primarily ultrasonic rather than radiographic. Many of the austenitic welds in safety-related piping systems provide limited access to both sides of the weld, so a far-side examination is necessary. Historically, far-side inspections have performed poorly because of the coarse and elongated grains that make up the microstructures of austenitic weldments. The large grains cause the ultrasound to be scattered, attenuated, and redirected. Additionally, grain boundaries or weld geometry may reflect coherent ultrasonic echoes, making flaw detection and discrimination a more challenging endeavor. Previous studies conducted at the Pacific Northwest National Laboratory (PNNL) on ultrasonic far-side examinations in austenitic piping welds involved the application of conventional transducers, use of low-frequency Synthetic Aperture Focusing Techniques (SAFT), and ultrasonic phased-array (PA) methods on specimens containing implanted thermal fatigue cracks and machined reflectors [1-2]. From these studies, PA inspection provided the best results, detecting nearly all of the flaws from the far side. These results were presented at the Fifth International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurised Components in 2006. This led to an invitation to examine field-removed specimens containing service-induced intergranular stress corrosion cracks (IGSCC) at the Electric Power Research Institute’s (EPRI) Nondestructive Evaluation (NDE) Center, in Charlotte, North Carolina. Results from this activity are presented.

36 MATERIALS SCIENCE↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗