Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive nulling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Perceptually-Based Adaptive JPEG Coding

An extension to the JPEG standard (ISO/IEC DIS 10918-3) allows spatial adaptive coding of still images. As with baseline JPEG coding, one quantization matrix applies to an entire image channel, but in addition the user may specify a multiplier for each 8 x 8 block, which multiplies the quantization matrix, yielding the new matrix for the block. MPEG 1 and 2 use much the same scheme, except there the multiplier changes only on macroblock boundaries. We propose a method for perceptual optimization of the set of multipliers. We compute the perceptual error for each block based upon DCT quantization error adjusted according to contrast sensitivity, light adaptation, and contrast masking, and pick the set of multipliers which yield maximally flat perceptual error over the blocks of the image. We investigate the bitrate savings due to this adaptive coding scheme and the relative importance of the different sorts of masking on adaptive coding.

Watson, Andrew B.↗

Precision bolometer bridge

Prototype precision bolometer calibration bridge is manually balanced device for indicating dc bias and balance with either dc or ac power. An external galvanometer is used with the bridge for null indication, and the circuitry monitors voltage and current simultaneously without adapters in testing 100 and 200 ohm thin film bolometers.

White, D. R.↗

NASA Tech Briefs, March 2005

Topics covered include: Scheme for Entering Binary Data Into a Quantum Computer; Encryption for Remote Control via Internet or Intranet; Coupled Receiver/Decoders for Low-Rate Turbo Codes; Processing GPS Occultation Data To Characterize Atmosphere; Displacing Unpredictable Nulls in Antenna Radiation Patterns; Integrated Pointing and Signal Detector for Optical Receiver; Adaptive Thresholding and Parameter Estimation for PPM; Data-Driven Software Framework for Web-Based ISS Telescience; Software for Secondary-School Learning About Robotics; Fuzzy Logic Engine; Telephone-Directory Program; Simulating a Direction-Finder Search for an ELT; Formulating Precursors for Coating Metals and Ceramics; Making Macroscopic Assemblies of Aligned Carbon Nanotubes; Ball Bearings Equipped for In Situ Lubrication on Demand; Synthetic Bursae for Robots; Robot Forearm and Dexterous Hand; Making a Metal-Lined Composite-Overwrapped Pressure Vessel; Ex Vivo Growth of Bioengineered Ligaments and Other Tissues; Stroboscopic Goggles for Reduction of Motion Sickness; Articulating Support for Horizontal Resistive Exercise; Modified Penning-Malmberg Trap for Storing Antiprotons; Tumbleweed Rovers; Two-Photon Fluorescence Microscope for Microgravity Research; Biased Randomized Algorithm for Fast Model-Based Diagnosis; Fast Algorithms for Model-Based Diagnosis; Simulations of Evaporating Multicomponent Fuel Drops; Formation Flying of Tethered and Nontethered Spacecraft; and Two Methods for Efficient Solution of the Hitting- Set Problem.

Source record↗

Adaptive Orbit Determination for Interplanetary Spacecraft

The interplanetary orbit problem has been traditionally solved using least-squares techniques. Due to operational limitations of this method, a Kalman filter approach has been proposed for future missions which includes all spacecraft and measurement modeling states in the filter.

adaptive↗

ZAG-Otolith: Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control during Variable Radius Centrifugation Following Space Flight

Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, <20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. One result of this study will be to characterize the variability (gain, asymmetry) in both otolithocular responses and motion perception during variable radius centrifugation, and measure the time course of postflight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

Wood, S. J.↗

Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control During Variable Radius Centrifugation Following Space Flight

Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, less than 20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. One result of this study will be to characterize the variability (gain, asymmetry) in both otolith-ocular responses and motion perception during variable radius centrifugation, and measure the time course of post-flight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

Wood, Scott J.↗

Design and Performance of the Keck Angle Tracker

The Keck Angle Tracker (KAT) is a key subsystem in the NASA-funded Keck Interferometer at the Keck Observatory on the summit of Mauna Kea in Hawaii. KAT, which has been in operation since the achievement of first fringes in March 2001, senses the tilt of the stellar wavefront for each of the beams from the interferometer telescopes and provides tilt error signals to fast tip/tilt mirrors for high-bandwidth, wavefront tilt correction. In addition, KAT passes low-bandwidth, desaturation offsets to the adaptive optics system of the Keck telescopes to correct for slow pointing drifts. We present an overview of the instrument design and recent performance of KAT in support of the V2 science and nulling observing modes of the Keck Interferometer.

adaptive optics↗

Broadband adaptively-controlled polarization-separation network

A broadband adaptively-controlled frequency-reuse system has been developed and demonstrated. The system is designed to operate at 11 GHz and above, where polarization deorthogonalization due to rain effects is a problem. Direct analog control is used to continually correct for varying cross polarization conditions. Two cancellation networks are presented; an electro-mechanical RF waveguide network, and an all-electronic IF network; each adaptively controlled using pilot signals, detecting the amount of cross polarized pilot in each channel, and nulling the signal. Cancellations of cross polarization to greater than 35 dB below the copolarized signal are demonstrated.

Gianatasio, A. J.↗

MEMS AO for Planet Finding

This slide presentation reviews a method for planet finding using microelectromechanical systems (MEMS) Adaptive Optics (AO). The use of a deformable mirror (DM) is described as a part of the instrument that was designed with a nulling interferometer. The strategy that is used is described in detail.

calibration interferometer↗

An Organic Decontamination Method for Sampling Devices used in Life-detection Studies

Organic decontamination of sampling and storage devices are crucial steps for life-detection, habitability, and ecological investigations of extremophiles living in the most inhospitable niches of Earth, Mars and elsewhere. However, one of the main stumbling blocks for Mars-analogue life-detection studies in terrestrial remote field-sites is the capability to clean instruments and sampling devices to organic levels consistent with null values. Here we present a new seven-step, multi-reagent cleaning and decontamination protocol that was adapted and tested on a glacial ice-coring device and on a rover-guided scoop used for sediment sampling both deployed multiple times during two field seasons of the Arctic Mars Analog Svalbard Expedition AMASE). The effectiveness of the protocols for both devices was tested by (1)in situ metabolic measurements via APT, (2)in situ lipopolysacchride (LPS) quantifications via low-level endotoxin assays, and(3) laboratory-based molecular detection via gas chromatography-mass spectrometry. Our results show that the combination and step-wise application of disinfectants with oxidative and solvation properties for sterilization are effective at removing cellular remnants and other organic traces to levels necessary for molecular organic- and life-detection studies. The validation of this seven-step protocol - specifically for ice sampling - allows us to proceed with confidence in kmskia4 analogue investigations of icy environments. However, results from a rover scoop test showed that this protocol is also suitable for null-level decontamination of sample acquisition devices. Thus, this protocol may be applicable to a variety of sampling devices and analytical instrumentation used for future astrobiology missions to Enceladus, and Europa, as well as for sample-return missions.

Eigenbrode, Jennifer↗

Zero-Net-Charge Air Ionizer

Instrument monitors air supplied by air ionizer and regulates ionizer to ensure net charge neutral. High-impedance electrometer and nulling control amplifier regulate output of air ionizer. Primarily intended to furnish ionized air having no net charge, instrument adaptable to generating air with positive or negative net charge is so desired. Useful where integrated circuit chips are manufactured, inspected, tested or assembled.

Woods, W. R., Jr.↗

Using Simulation to Analyze Acoustic Environments

One of the main projects that was worked on this semester was creating an acoustic model for the Advanced Space Suit in Comsol Multiphysics. The geometry tools built into the software were used to create an accurate model of the helmet and upper torso of the suit. After running the simulation, plots of the sound pressure level within the suit were produced, as seen below in Figure 1. These plots show significant nulls which should be avoided when placing microphones inside the suit. In the future, this model can be easily adapted to changes in the suit design to determine optimal microphone placements and other acoustic properties. Another major project was creating an acoustic diverter that will potentially be used to route audio into the Space Station's Node 1. The concept of the project was to create geometry to divert sound from a neighboring module, the US Lab, into Node 1. By doing this, no new audio equipment would need to be installed in Node 1. After creating an initial design for the diverter, analysis was performed in Comsol in order to determine how changes in geometry would affect acoustic performance, as shown in Figure 2. These results were used to produce a physical prototype diverter on a 3D printer. With the physical prototype, testing was conducted in an anechoic chamber to determine the true effectiveness of the design, as seen in Figure 3. The results from this testing have been compared to the Comsol simulation results to analyze how closely the Comsol results are to real-world performance. While the Comsol results do not seem to closely resemble the real world performance, this testing has provided valuable insight into how much trust can be placed in the results of Comsol simulations. A final project that was worked on during this tour was the Audio Interface Unit (AIU) design for the Orion program. The AIU is a small device that will be used for as an audio communication device both during launch and on-orbit. The unit will have functions including push-to-talk buttons and volume control. With this project, an existing design was modified based on prior feedback that had been received. With the modified design, I created a 3D printed prototype, shown in Figure 4, which was then used in suited evaluations performed by crew members. The feedback received from those evaluations will be utilized to help create the best possible Orion AIU. As a whole, a number of different interesting engineering projects were worked on over the course of this semester. For many of these projects, acoustic simulations provided valuable insight into how different environments would respond to sound. While work is still underway to verify the results of these simulations, the results are fascinating because of the interesting ways that sound waves interact with the environment. Going forward, it will be interesting to see how closely these results can be matched by real-world test data.

Wood, Eric J.↗

Overview of LBTI: A Multipurpose Facility for High Spatial Resolution Observations

The Large Binocular Telescope Interferometer (LBTI) is a high spatial resolution instrument developed for coherent imaging and nulling interferometry using the 14.4 m baseline of the 2x8.4 m LBT. The unique telescope design, comprising of the dual apertures on a common elevation-azimuth mount, enables a broad use of observing modes. The full system is comprised of dual adaptive optics systems, a near-infrared phasing camera, a 1-5 micrometer camera (called LMIRCam), and an 8-13 micrometer camera (called NOMIC). The key program for LBTI is the Hunt for Observable Signatures of Terrestrial planetary Systems (HOSTS), a survey using nulling interferometry to constrain the typical brightness from exozodiacal dust around nearby stars. Additional observations focus on the detection and characterization of giant planets in the thermal infrared, high spatial resolution imaging of complex scenes such as Jupiter's moon, Io, planets forming in transition disks, and the structure of active Galactic Nuclei (AGN). Several instrumental upgrades are currently underway to improve and expand the capabilities of LBTI. These include: Improving the performance and limiting magnitude of the parallel adaptive optics systems; quadrupling the field of view of LMIRcam (increasing to 20"x20"); adding an integral field spectrometry mode; and implementing a new algorithm for path length correction that accounts for dispersion due to atmospheric water vapor. We present the current architecture and performance of LBTI, as well as an overview of the upgrades.

The Large Binocular Telescope Interferometer (LBTI↗

Visibility of Wavelet Quantization Noise

The Discrete Wavelet Transform (DWT) decomposes an image into bands that vary in spatial frequency and orientation. It is widely used for image compression. Measures of the visibility of DWT quantization errors are required to achieve optimal compression. Uniform quantization of a single band of coefficients results in an artifact that is the sum of a lattice of random amplitude basis functions of the corresponding DWT synthesis filter, which we call DWT uniform quantization noise. We measured visual detection thresholds for samples of DWT uniform quantization noise in Y, Cb, and Cr color channels. The spatial frequency of a wavelet is r 2(exp)-L , where r is display visual resolution in pixels/degree, and L is the wavelet level. Amplitude thresholds increase rapidly with spatial frequency. Thresholds also increase from Y to Cr to Cb, and with orientation from low-pass to horizontal/vertical to diagonal. We describe a mathematical model to predict DWT noise detection thresholds as a function of level, orientation, and display visual resolution. This allows calculation of a "perceptually lossless" quantization matrix for which all errors are in theory below the visual threshold. The model may also be used as the basis for adaptive quantization schemes.

Watson, Andrew B.↗

SCExAO: First Results and On-Sky Performance

We present new on-sky results for the Subaru Coronagraphic Extreme Adaptive Optics imager (SCExAO) verifying and quantifying the contrast gain enabled by key components: the closed-loop coronagraphic low-order wavefront sensor (CLOWFS) and focal plane wavefront control ("speckle nulling"). SCExAO will soon be coupled with a high-order, Pyramid wavefront sensor which will yield greater than 90% Strehl ratio and enable 10(exp 6) -10(exp 7) contrast at small angular separations allowing us to image gas giant planets at solar system scales. Upcoming instruments like VAMPIRES, FIRST, and CHARIS will expand SCExAO's science capabilities.

Subaru Coronagraphic Extreme Adaptive Optics image↗

Role of Vibration-Induced Streaming in Float-Zone Crystal Growth

This presentation will examine in detail the role of vibration-induced streaming flow in the context of float-zone crystal growth. It is very well known that during float-zone materials processing, the naturally occurring temperature gradients along the zone surface impose a thermocapillary flow in the zone. Under certain processing conditions, the thermocapillary flow can also become nonsteady (oscillatory). The presence of thermocapillary flow is detrimental to crystal quality, for it can promote non-uniform dopant distribution and crystal striations. To null this effect we have imposed a counter streaming flow in the zone, via end-wall vibration. This technique has been adapted to float-zone processing of Sodium Nitrate-Barium Nitrate eutectic alloys, under both steady and nonsteady thermocapillary flow conditions. The beneficial effects of counter streaming flow have been clearly brought out through the before and after comparisons of the crystal microstructure. In addition, we are also examining the theoretical underpinnings of the balancing of thermocapillary flows with vibration-driven counter flows in float-zones.

Anilkumar, A. V.↗

Role of Vibration-Induced Streaming in Float-Zone Crystal Growth

This presentation will examine in detail the role of vibration-induced streaming flow in the context of float-zone crystal growth. It is very well known that during float-zone materials processing, the naturally occurring temperature gradients along the zone surface impose a thermocapillary flow in the zone. Under certain processing conditions, the thermocapillary flow can also become nonsteady (oscillatory). The presence of thermocapillary flow is detrimental to crystal quality, for it can promote non-uniform dopant distribution and crystal striations. To null this effect we have imposed a counter streaming flow in the zone, via end-wall vibration. This technique has been adapted to float-zone processing of Sodium Nitrate-Barium Nitrate eutectic alloys, under both steady and nonsteady thermocapillary flow conditions. The beneficial effects of counter streaming flow have been clearly brought out through the before and after comparisons of the crystal microstructure. In addition, we are also examining the theoretical underpinnings of the balancing of thermocapillary flows with vibration-driven counter flows in float-zones.

Anikumar, A. V.↗

Displacing Unpredictable Nulls in Antenna Radiation Patterns

A method of maintaining radio communication despite the emergence of unpredictable fades and nulls in the radiation pattern of an antenna has been proposed. The method was originally intended to be applied in the design and operation of a radio antenna aboard a robotic exploratory vehicle on a remote planet during communication with a spacecraft in orbit around the planet. The method could also be applied in similar terrestrial situations for example, radio communication between two ground vehicles or between a ground vehicle and an aircraft or spacecraft. The method is conceptually simple, is readily adaptable to diverse situations, and can be implemented without adding greatly to the weight, cost, power demand, or complexity of a system to which it may be applied. The unpredictable fades and nulls in an antenna radiation pattern arise because of electromagnetic interactions between the antenna and other objects within the near field of the antenna (basically, objects within a distance of a few wavelengths). These objects can include general vehicle components, masts, robotic arms, other antennas, the ground, and nearby terrain features. Figure 1 presents representative plots of signal strength versus time during a typical pass of a spacecraft or aircraft through the far field of such an antenna, showing typical nulls and fades caused by nearby objects. The traditional approach to ensuring reliability of communication in the presence of deep fades calls for increasing the effective transmitter power and/or reducing the receiver noise figure at the affected ground vehicle, possibly in combination with appropriate redesign of the equipment at the spacecraft or aircraft end of the communication link. These solutions can be expensive and/or risky and, depending on the application, can add significantly to weight, cost, and power demand. The proposed method entails none of these disadvantages.

Lux, James↗