Search NASA⌕ Search

SEARCH · Search NASA

Results for “admissibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Finite element structural redesign by large admissible perturbations

In structural redesign, two structural states are involved; the baseline (known) State S1 with unacceptable performance, and the objective (unknown) State S2 with given performance specifications. The difference between the two states in performance and design variables may be as high as 100 percent or more depending on the scale of the structure. A Perturbation Approach to Redesign (PAR) is presented to relate any two structural states S1 and S2 that are modeled by the same finite element model and represented by different values of the design variables. General perturbation equations are derived expressing implicitly the natural frequencies, dynamic modes, static deflections, static stresses, Euler buckling loads, and buckling modes of the objective S2 in terms of its performance specifications, and S1 data and Finite Element Analysis (FEA) results. Large Admissible Perturbation (LEAP) algorithms are implemented in code RESTRUCT to define the objective S2 incrementally without trial and error by postprocessing FEA results of S1 with no additional FEAs. Systematic numerical applications in redesign of a 10 element 48 degree of freedom (dof) beam, a 104 element 192 dof offshore tower, a 64 element 216 dof plate, and a 144 element 896 dof cylindrical shell show the accuracy, efficiency, and potential of PAR to find an objective state that may differ 100 percent from the baseline design.

Bernitsas, Michael M.↗

Axial-slot Air Admission for Controlling Performance of a One-quarter-annulus Turbojet Combustor and Comparison with Complete Engine

An investigation of a single-annulus turbojet combustor with slot-type air admission was conducted to demonstrate the application of certain design principles to the control of outlet-gas temperature distributions. Comparisons of performance of a one-quarter-annulus combustor (duct-type installation) and a full-annulus combustor (obtained in a full-scale turbojet engine) are presented to indicate the applicability of results obtained from combustion studies conducted in duct-type installations. A reasonable correlation existed between the performance of the one-quarter-annulus and full-annulus combustors except for temperature distribution. Sufficient trends did exist which made it possible to predict temperature distributions for the engine, although absolute correlation did not exist. A radial temperature distribution similar to that required for a given engine was obtained using a one-quarter-annulus duct-type setup to predict results.

COMBUSTION--TURBINE ENGINES↗

Comparison of Full and Partial Admission Flow Fields in the Simplex Turbine

This viewgraph presentation provides information on computerized simulations of flow fields in a Simplex turbine. The motivations for the simulation were: Determining the effects of partial admission flow on rotor performance as a function of circumferential location and on unsteady rotor loading; Providing an efficient technique for determining turbine performance. The simulation used the flow code CORSAIR.

Dorney, Daniel J.↗

Cooling of Gas Turbines I - Effects of Addition of Fins to Blade Tips and Rotor, Admission of Cooling Air Through Part of Nozzles, and Change in Thermal Conductivity of Turbine Components

An analysis was developed for calculating the radial temperature distribution in a gas turbine with only the temperatures of the gas and the cooling air and the surface heat-transfer coefficient known. This analysis was applied to determine the temperatures of a complete wheel of a conventional single-stage impulse exhaust-gas turbine. The temperatures were first calculated for the case of the turbine operating at design conditions of speed, gas flow, etc. and with only the customary cooling arising from exposure of the outer blade flange and one face of the rotor to the air. Calculations were next made for the case of fins applied to the outer blade flange and the rotor. Finally the effects of using part of the nozzles (from 0 to 40 percent) for supplying cooling air and the effects of varying the metal thermal conductivity from 12 to 260 Btu per hour per foot per degree Farenheit on the wheel temperatures were determined. The gas temperatures at the nozzle box used in the calculations ranged from 1600F to 2000F. The results showed that if more than a few hundred degrees of cooling of turbine blades are required other means than indirect cooling with fins on the rotor and outer blade flange would be necessary. The amount of cooling indicated for the type of finning used could produce some improvement in efficiency and a large increase in durability of the wheel. The results also showed that if a large difference is to exist between the effective temperature of the exhaust gas and that of the blade material, as must be the case with present turbine materials and the high exhaust-gas temperatures desired (2000F and above), two alternatives are suggested: (a) If metal with a thermal conductivity comparable with copper is used, then the blade temperature can be reduced by strong cooling at both the blade tip and root. The center of the blade will be less than 2000F hotter than the ends; (b) With low conductivity materials some method of direct cooling other than partial admission of cooling air is essential. From this study, it can be deduced that indirect cooling of turbine blades will not make possible large increases in gas temperature.

Brown, Byron↗

Curved film cooling admission tube

Effective film cooling to protect a wall surface from a hot fluid which impinges on or flows along the surface is provided. A film of cooling fluid having increased area is provided by changing the direction of a stream of cooling fluid through an angle of from 135 deg. to 165 deg. before injecting it through the wall into the hot flowing gas. The 1, cooling fluid is injected from an orifice through a wall into a hot flowing gas at an angle to form a cooling fluid film. Cooling fluid is supplied to the orifice from a cooling fluid source via a turbulence control passageway having a curved portion between two straight portions. The angle through which the direction of the cooling fluid is turned results in less mixing of the cooling fluid with the hot gas, thereby substantially increasing the length of the film in a downstream direction.

Graham, R. W.↗

On compactness of admissible parameter sets: Convergence and stability in inverse problems for distributed parameter systems

A series of numerical examples is reported and several algorithms compared for estimation of coefficients in differential equation models. Unconstrained, constrained and Tikhonov regularization methods are tested for their behavior with regard to both convergence (of approximation methods for the states and parameters) and stability (continuity of the estimates with respect to perturbations in the data or observed states).

Banks, H. T.↗

Admissible upstream conditions for slender compressible vortices

The influence of the compressibility on the flow in slender vortices is being studied. The dependence of the breakdown of the slender-vortex approximation on the upstream conditions is demonstrated for various Reynolds numbers and Mach numbers. Compatibility conditions, which have to be satisfied if the vortex is to remain slender, are discussed in detail. The general discussions are supplemented by several sample calculations.

Liu, C. H.↗

On the stochastic dissemination of faults in an admissible network

The dynamic distribution of faults in a general type network is discussed. The starting point is a uniquely branched network in which each pair of nodes is connected by a single branch. Mathematical expressions for the uniquely branched network transition matrix are derived to show that sufficient stationarity exists to ensure the validity of the use of the Markov Chain model to analyze networks. In addition the conditions for the use of Semi-Markov models are discussed. General mathematical expressions are derived in an examination of branch redundancy techniques commonly used to increase reliability.

Kyrala, A.↗

Simulated altitude performance of two annular combustors with continuous axial openings for admission of primary air

Methods of introducing and distributing air and fuel in turbojet-engine combustors were evaluated with two fuels, AN-F-32 and AN-F-58. Investigations were made with two single-annulus liners in a one-quarter sector of a 25 1/2-inch-diameter turbojet combustor. Altitude performance data for these combustors are compared with existing data for a production-model double-annulus combustor. Altitude operating limits and combustion efficiencies of both single-annulus combustors were considerably higher than those of the double-annulus combustor; combustion efficiencies were insensitive to changes in fuel-air ratio.

COMBUSTION - TURBINE ENGINES↗