Variables influencing the strain-age cracking and mechanical properties of Rene 41 and related alloys
Rene 41 ductility reduction by environmental oxygen promoting intergranular cracking at high temperatures
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Rene 41 ductility reduction by environmental oxygen promoting intergranular cracking at high temperatures
The mechanical properties are presented of solution treated and age hardened A-286 corrosion resistant steel bar stock. Material solution treated at 899 C or 982 C, each followed by an age hardening treatment of 718 C, was evaluated. Test specimens manufactured from 1.50 inch (3.81 cm) diameter bar stock were tested at temperatures from +649 C to -253 C. The test data indicated excellent tensile, yield, elongation and reduction-in-area properties at all testing temperatures for both solution treated and aged materials. Cryogenic temperature notched tensile, impact, and shear tests indicated excellent notch strength, ductility, and shear values. There was very little difference in the mechanical properties of the two solution treated and aged materials. The only exception was that the 962 C solution treated and aged material had superior stress rupture properties at 649 C.
Exercise capacity and skeletal muscle blood flow during exercise are reduced with advancing age. This reduction in blood flow capacity may be related to increased reactivity of skeletal muscle resistance vessels to vasoconstrictor stimuli. The purpose of this study was to test the hypothesis that aging results in increased vasoconstrictor responses of skeletal muscle resistance arterioles. First-order (1A) arterioles (90-220 microm) from the gastrocnemius and soleus muscles of young (4 mo) and aged (24 mo) Fischer-344 rats were isolated, cannulated, and pressurized via hydrostatic reservoirs. Vasoconstriction in response to increases in norepinephrine (NE; 1 x 10(-9)-1 x 10(-4) M) and KCl (20-100 mM) concentrations and increases in intraluminal pressure (10-130 cmH(2)O) were evaluated in the absence of flow. Responses to NE and KCl were similar in both soleus and gastrocnemius muscle arterioles from young and aged rats. In contrast, active myogenic responses to changes in intraluminal pressure were diminished in soleus and gastrocnemius arterioles from aged rats. To assess whether alterations in the mechanical properties of resistance arterioles underlie altered myogenic responsiveness, passive diameter responses to pressure and mechanical stiffness were evaluated. There was no effect of age on the structural behavior (passive pressure-diameter relationship) or stiffness of arterioles from either the soleus or gastrocnemius muscles. These results suggest that aging does not result in a nonspecific decrease in vasoconstrictor responsiveness of skeletal muscle arterioles. Rather, aging-induced adaptations of vasoreactivity of resistance arterioles appear to be limited to mechanisms that are uniquely involved in the signaling of the myogenic response.
An investigation was conducted to determine the age-hardening response and cryogenic mechanical properties of superplastic Al-Cu-Li-Zr-In alloys. Two alloys with compositions Al-2.65Cu-2.17Li-O.13Zr (baseline) and Al-2.60Cu-2.34Li-0.16Zr-0.17In were scaled-up from 30 lb permanent mold ingots to 350 lb DC (direct chill) ingots and thermomechanically processed to 3.2 mm thick sheet. The microstructure of material which contained the indium addition was partially recrystallized compared to the baseline suggesting that indium may influence recrystallization behavior. The indium-modified alloy exhibited superior hardness and strength compared to the baseline alloy when solution-heat-treated at 555 C and aged at 160 C or 190 C. For each alloy, strength increased and toughness was unchanged or decreased when tested at - 185 C compared to ambient temperature. By using optimized heat treatments, the indium-modified alloy exhibited strength levels approaching those of the baseline alloy without deformation prior to aging. The increase in strength of these alloys in the T6 condition make them particularly attractive for superplastic forming applications where post-SPF parts cannot be cold deformed to increase strength.
Experimental study addresses related topics of thermo-oxidative aging of PMR-15 (polyimide matrix/graphite-fiber composite materials) strengths of interfacial bonds, effects of various surface treatments, and relative merits of mechanical tests yielding measures of strengths of materials.
Red blood cell mechanical fragility independence from cell age in rats
Age hardening in Inconel 718 is investigated using Brinell hardness measurements. Formation of a precipitate causes an increase in hardness.
The relative contributions of the hardening mechanisms in Hastelloy X during cyclic deformation were investigated by conducting isothermal cyclic deformation tests within a total strain range of +/-0.3 pct and at several temperatures and strain rates, and thermomechanical tests within several different temperature limits. The results of the TEM examinations and special constant structure tests showed that the precipitation on dislocations of Cr23C6 contributed to hardening, but only after sufficient time above 500 C. Solute drag alone produced very considerable cyclic hardening. Heat dislocation densities, peaking around 10 exp 11 per sq cm, were found to develop at temperatures producing the greatest cyclic hardening.
Age dependent changes in geotaxis profiles were examined in 27 wild-type populations of Drosophila, representing a diversity of species, semispecies and strains. In addition, four strains of D. melanogaster were tested. Tests were carried out at a minimum of three test ages, and involve the use of a calibrated, adjustable inclined plane that can be set at any angle between 0 and 85 deg. Among selected lines, decline in geotactic response occurs later in the long lived flies than in the controls. Longer lived flies continue to show an increase in negative geotactic response through age 14 days. These results suggest that common processes may be influencing the rate of decline in geotactic response and longevity. Further analysis of the mechanisms underlying age dependent changes in geotaxis may reveal factors which influence the aging process itself. The use of geotaxis aging markers in a broad range of Drosophila species reflecting varying degrees of genetic relatedness is proposed to test the universality vs. specificity of aging processes.
Work has included significant research in several areas aimed at further clarification of the aging and chemical failure mechanism of thermoplastics (PVDF or Tefzel) for pipes. Among the areas investigated were the crystallinity changes associated with both the Coflon and Tefzel after various simulated environmental exposures using X-Ray diffraction analysis. We have found that significant changes in polymer crystallinity levels occur as a function of the exposures. These crystallinity changes may have important consequences on the fracture, fatigue, tensile, and chemical resistance of the materials. We have also noted changes in the molecular weight distribution of the Coflon material using a dual detector Gel Permeation Analysis. Again these changes may result in variation in the mechanical and chemical properties in the material. We conducted numerous analytical studies with methods including X-Ray Diffraction, Gel Permeation Chromatography, Fourier Transform Infrared Spectroscopy, Thermogravimetric Analysis, and Differential Scanning Calorimetry. We investigated a number of aged samples of both Tefzel and Coflon that were forwarded from MERL. Pressurized tests were performed in a modified Fluid G, which we will call G2. In this case the ethylene diamine concentration was increased to 3 percent in methanol. Coflon pipe sections and powdered Coflon were exposed in pressure cells at 1700 psi at three separate test temperatures, 70 C, 110 C, and 130 C. The primary purpose of the pressure tests in Fluid G2 was to further elucidate the aging mechanism of PVDF degradation.
Development efforts have been undertaken to improve the processing and structural efficiencies of advanced cold-formable beta Ti alloys, using the standard, hot-formed and rivetted construction of Ti-6Al-4V sheet structures as a basis for comparison. Ti-15V-3Cr-3Al-3Sn (Ti-15-3) beta alloy is formable, brazable and weldable in the solution-treated condition, and after aging displays mechanical properties suitable for postulated service in the -65 to 600 F temperature range. A novel methodology using cold-formed Ti-15-3 stringers and Ti-6Al-4V face sheets that are joined by means of an out-of-furnace isothermal brazing process, followed by low temperature aging, can reduce production costs by as much as 28 per cent. Structural efficiency has been demonstrated in room and elevated temperature crippling tests of small skin-stringer assemblies.
This study examines and compares the effect of different heat treatments (HT) on the microstructure and mechanical properties of Monel K500 fabricated using laser powder bed fusion (L-PBF) and laser powder directed energy deposition (LP-DED) technologies. The as-fabricated Monel K500 specimens exhibited dendritic microstructure and elemental micro-segregation due to high cooling rates induced during the fabrication process. The applicability of HT proposed in the literature for wrought Monel K500 was investigated for L-PBF and LP-DED using four different HT procedures involving hot isostatic pressing (HIP), solution annealing (SA), and aging. The mechanical properties of test specimens were evaluated using uniaxial tensile testing at room temperature. The microstructural evolution of test specimens during HT was analyzed using a scanning electron microscope. For all HT conditions investigated, L-PBF Monel K500 specimens consistently displayed higher strength and lower ductility compared to the LP-DED counterparts. The HT procedure involving HIP at 1160°C for 3hr at 100 MPa, SA at 1100°C for 15 min, and three step aging at 610°C for 16 hr, 540°C for 6 hr, and 480°C for 8 hr resulted in highest strength for both L-PBF and LP-DED fabricated Monel K500.
The effect of long-term, elevated-temperature vacuum and lithium exposures on the mechanical properties of T-111 (Ta-8W-2Hf) is determined. Exposure conditions were for 1000 hours at 980 or 1315 C, 5000 hours at 1315 C, and a duplex temperature exposure of 1000 hours at 980 C plus 4000 hours at 1040 C. The exposures resulted in reduced tensile and creep strengths of the T-111 in the 900 to 1100 C temperature range where a dynamic strain-age-strengthening mechanism is operative in this alloy. This strength reduction was attributed to the depletion of oxygen from solid solution in this alloy.
This report deals with all recent mechanical testing performed on variously aged samples of Coflon and TefzeL to complete the work for Phase 1. Earlier results were reported in CAPP/M.7. Fluids A, F, G, and I have all been used for ageing in the last 12 month period, with particular attention concentrated on the effects of Fluid F as a result of discussions at the December 1995 steering committee meeting in Austin. Dramatic mechanical and physical changes occurred to Coflon in our initial studies after 4 weeks at 120 C in this sour gas mixture and so a detailed matrix was drawn up to investigate the effects of time and temperature of exposure. Subsequent tensile tests and compact tension (CT) fatigue tests were performed. Fatigue testing has been limited during this period to Coflon only; however, Tefzel CT samples have been exposed to the same conditions as the Coflon allowing the possibility for fatigue tests to be performed at a later date. Fluid A exposures during the last 6 months have been long-term at 65 C, 100 C and 120 C only. These exposures have been a continuation of earlier work and will complete the investigation of this fluid. Other chemical ageings have involved Fluid G at 120 C to confirm and investigate the hostile nature of this fluid on Coflon. Again, this fluid will not be used in Phase 2. Finally, long-term exposures in Fluid 1, a high aromatic oil mixture, were carried out to investigate the effects on the polymers of aromaticity in a simulated service fluid.
While the electronics industry appears to be focusing on Sn-Ag-Cu as the alloy of choice for lead free electronics assembly, ,the exact composition varies by geographic region, supplier and user. Add to that dissolved copper and silver from the printed circuit board traces and surface finish, and there can be significant variation in the final solder joint composition. A systematic study of the mechanical and microstructural properties of Sn-Ag-Cu alloys with Ag varying from 2wt% to 4wt% and Cu varying from 0.5wt% to lSwt%, was undertaken in this research study. Different sample preparation techniques (water quenched, oil quenched and water quenched followed by reflow) were explored and the resulting microstructure compared to that of a typical reflowed lead free chip scale package (CSP) solder joint. Tensile properties (modulus, 0.2% yield strength and the ultimate tensile strength) and creep behavior of selected alloy compositions (Sn-4Ag-1 X u , Sn-4Ag-OSCu, Sn- 2Ag-1 X u , Sn-2Ag-OSCu, Sn-3.5Ag-O.SCu) were determined for three conditions: as- cast; aged for 100 hours at 125OC; and aged for 250 hours at 125OC. There was no significant difference in Young's Modulus as a function of alloy composition. After an initial decrease in modulus after 100 hours at 125"C, there was an insignificant change with further aging. The distribution of 0.2% strain yield stress and ultimate tensile strength as a function of alloy composition was more significant and decreased with aging time and temperature. The microstructures of these alloys were examined using light and scanning electron microscopy (LM and SEM) respectively and SEM based energy dispersive x-ray spectroscopy (EDS). Fracture surface and cross-section analysis were performed on the specimens after creep testing. The creep testing results and the effect of high temperature aging on mechanical properties is presented for the oil quenched samples. In general the microstructure of oil quenched specimen exhibited a eutectic region of Sn with moderately dispersed Ag3Sn intermetallic, surrounded by a dendritic Sn-rich phase. The SEM images of the fracture surface indicated the presence of a tough shear surface at the initial cavity break area and a break line in the middle of specimen along the failure direction. A hyperbolic-sine creep model was adopted and used to fit the creep experiment data. The effect on the mechanical properties by adding the quaternary element bismuth to the Sn-3.5Ag-0.8Cu alloy was measured and compared with the mechanical properties of the ternary alloys. The results of this research study provide necessary data for the modeling of solder joint reliability for a range of Sn-Ag-Cu compositions and a baseline for evaluating the effects of subsequent quaternary additions.
The hygrothermal aging characteristics of an epoxy resin were characterized over 1 year, which included 908 temperature and humidity cycles. The epoxy resin quickly showed evidence of aging through color change and increased brittleness. The influence of aging on the material s glass transition temperature (Tg) was evaluated by Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA). The Tg remained relatively constant throughout the year long cyclic aging profile. The chemical composition was monitored by Fourier Transform Infrared Spectroscopy (FTIR) where evidence of chemical aging and advancement of cure was noted. The tensile strength of the resin was tested as it aged. This property was severely affected by the aging process in the form of reduced ductility and embrittlement. Detailed chemical evaluation suggests many aging mechanisms are taking place during exposure to hygrothermal conditions. This paper details the influence of processes such as: advancement of cure, chemical degradation, and physical aging on the chemical and physical properties of the epoxy resin.
A description is presented of a test program which has shown that well-constructed bubble memories can operate reliably over long periods of time and at low error rates. Even the relatively high error rate of one memory during burn-in can be considered acceptable if compared with tape recorder standards. No wear-out mechanism or aging could be detected. Bubble memories are now considered suitable for long-duration space missions and certainly are suitable for many military and commercial applications. It must be recognized, however, that bubble memories are complex devices and not yet fully understood. While the particular memory tested may never find practical applications, it nevertheless has provided insight into performance characteristics considered typical of bubble memories.
Traditionally, the use of brittle materials has been avoided in demanding structural applications because of their unreliability. They have been used however, due to other desirable properties, in nonstructural applications or where the mechanical load is minimal. The most common method utilized today for the design approach of brittle materials is the probabilistic, which takes into consideration the flaw and stress distribution within the brittle material. It does not take into consideration the fracture mechanics effect of strength degradation while aging under a mechanical load. This project will combine the two methods, probabilistic and fracture mechanics, into a more reliable design method for brittle materials.