Search NASA⌕ Search

SEARCH · Search NASA

Results for “air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Cold air quench control of local crystallization environment in fully air-processed carbon-based perovskite solar cells

Carbon-based perovskite solar cells (C-PSCs) present a low-cost route to efficient photovoltaic technology. Gas quenching is an essential process commonly used for solvent extraction in scalable module fabrication using solution processes, but film quality remains highly sensitive to the localized environmental processing temperature, especially during intermediate phase transitions before perovskite film high temperature annealing. In this study, we introduce a cold air quench strategy to precisely control the local crystallization temperature that simultaneously promotes uniform crystallization and facilitates strain relaxation in fully air-processed C-PSCs. It is found that implementing dry air at 10 °C as the quenching gas yields a champion power conversion efficiency (PCE) of 20.52 %, with preferential (110) orientation and reduced, homogenized in-plane strain. This newly developed technique of a cost-effective low temperature air quenching process also enhances carrier lifetime, reduces interface recombination, and improves charge extraction. Furthermore, this work presents cold air quenching as a scalable, economic method to control perovskite crystallization and strain in C-PSC fabrication, advancing the industrial viability of high-performance perovskite modules.

14 SOLAR ENERGY↗

An Experimental and Theoretical Examination of Air Ingress Rates During Small- and Medium-Break Air Ingress Accidents

Here, air ingress measurements using the 1/20th-scaled Helium Air Ingress gas Reactor Experiment (HAIRE) facility show key geometric variables of interest and their effect on air ingress in small- and medium-sized breaks in High Temperature Gas cooled Reactors. These variables include but are not limited to break diameter, break angle, and break wall thickness. Differing wall thicknesses for the same break diameter can have order-of-magnitude changes to the air ingress rate, which is a key figure of merit in the air ingress accident scenario. Additionally, different break sizes can change the importance of the angle in the break scenario. With smaller breaks, the flow will not transition from intermittent flow, to countercurrent flow, to diffusive flow as the break rotates from vertically upward toward vertically downward. This would lead to less variability with smaller breaks, which in turn would make the accident scenario more predictable for smaller-sized breaks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Protective effects of non–catalytic proteins on endoglucanase activity at air and lignin interfaces

The manner in which added non-catalytic proteins during enzymatic hydrolysis of lignocellulosic substrates enhances hydrolysis mechanisms is not completely understood. Prior research has indicated that a reduction in the non-specific adsorption of enzymes on lignin, and deactivation of enzymes exposed to air–liquid interface provide rationale. This work investigated root causes including effects of the air–liquid interface on non-catalytic proteins, and effects of lignin on endoglucanase. Three different experimental designs and three variables (air–liquid interfacial area, the types of lignin (acid or enzymatic lignin), and the presence of non-enzymatic protein (bovine serum albumin [BSA] or soy proteins ) were used. The results showed that acid isolated lignin adsorbed almost all endoglucanase activity initially present in supernatant, independent of air interface conditions (25 or 250 ml flasks) with the presence of BSA preventing this effect. Endoglucanase lost 30%–50% of its activity due to an air–liquid interface in the presence of lignin while addition of non-enzymatic protein helped to preserve this enzyme's activity. Langmuir and Freundlich models applied to experimental data indicated that the adsorption increases with increasing temperature for both endoglucanase and BSA. Adsorption of the enzyme and protein were endothermic with an increase in entropy. Finally, these results, combined, show that hydrophobicity plays a strong role in the adsorption of both endoglucanase and BSA on lignin.

59 BASIC BIOLOGICAL SCIENCES↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

Chemical Challenges that the Peroxide Dianion Presents to Rechargeable Lithium–Air Batteries

Understanding the fundamental redox reactions and processes that occur in lithium–air and, more generally, metal–air batteries is important to the progress of this promising energy-storage technology. Knowledge of the chemistry of the peroxide dianion, O 2 2– , is especially crucial, as the dianion is at the nexus of the charge/discharge cycle of lithium–air batteries. The intrinsic electron transfer properties and redox chemistry of peroxide dianion are poorly defined because it is difficult to isolate the dianion free of protons and metal ions. We review the results of (i) the electron transfer kinetics and (ii) the redox reaction chemistry of isolated peroxide dianion encapsulated within the cavity of a hexacarboxamide cryptand. With regard to the former, electron transfer kinetics measurements provide fundamental Marcus parameters that will be useful for models that seek to disentangle the precise contributions of Li + ion-coupled electron transfer, electron transfer across the Li 2 O 2 solid particle interface, and charge hopping among Li 2 O 2 particles. With regard to the latter, an underappreciated chemistry of peroxide dianion with CO 2 produces peroxymonocarbonate (OOCO 2 2– ) and peroxydicarbonate (O 2 COOCO 2 2– ). An autocatalytic cycle will lead to oxidative degradation of traditional organic electrolytes and other vulnerable cell components employed in lithium–air batteries. Furthermore, this peroxycarbonate-derived chemistry, in addition to more commonly recognized solution-based oxidation chemistry, will need to be mitigated to realize the long-term cyclability of rechargeable lithium–air batteries.

25 ENERGY STORAGE↗

Impact of ceiling fan and room air cleaner on air mixing and fate of particulate matter in a multiroom residence

We are exposed to airborne particles of health concern in residences, and Room Air Cleaners (RACs) can remove these particles. However, they are often limited to treating local air in the room or near vicinity of the device. RAC performance in multi-room residences may be improved by ceiling fan whole-house air mixing with a minor increase in energy use. Here, this study analyzed air quality and energy efficiency from experimental measurements using combinations of ceiling fan and RAC operation. We measured removal rates of tracer gas and particles from ultrafine to 5 µm after their release in the kitchen area of a multiroom test house. Results show that the air mixing by ceiling fans increased ultrafine and > 1 µm particle removal over the baseline – with no ceiling fans and no RAC – suggesting increased deposition onto the ceiling fan blades and house surfaces. Also, ceiling fan mixing increased particle removal in all size bins over the RAC performance with no ceiling fans. The removal rate with ceiling fans and the RAC was greater than the sum of the rates from each operating alone, indicating that synergistic interactions between the ceiling fans and the RAC increased the RAC filtration rate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Quaternary ammonium salt coated air filter for bioaerosol removal from building indoor air

Developing air filters with biocidal ability is important to protect the public from infectious respiratory diseases. A simple spray-coating approach was devised to fabricate antimicrobial air filters to remove bioaerosols. Here, the commercial antimicrobial agent Goldshield 75 was coated on the air filters through covalent immobilization, endowing the fabricated filter with long-lasting biocidal ability. All coated filters significantly inhibited both Gram-positive bacteria (Micrococcus luteus) and Gram-negative bacteria (Escherichia coli). The antibacterial ability of the coated filters is similar to the commercial AeraSafe antibacterial filter. The coated filter showed over 99.9 % antibacterial efficiency 3 months after the application of the coating. Both bacterial and virus filtration efficiencies of coated charged polypropylene filter were higher than 99.9 %. The coating did not have much effect on the NaCl aerosol filtration efficiency of the filters. This simple spray-coating strategy is a practical method for producing antimicrobial air filters for the prevention of infectious respiratory diseases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An effective air–liquid contactor for CO 2 direct air capture using aqueous solvents

Here, the development of a cost-effective, corrosion resistant, high-flux direct air capture (HiDAC) contactor for a solvent-based direct air capture (DAC) process is reported. Literature technoeconomic analyses suggest that the air–liquid contactor can cost over 20 % of the overall DAC plant’s annualized capital costs. To bring down the overall cost of DAC, it is imperative that an effective contactor is developed. A hybrid contactor consisting of a commercial polyvinylchloride structured packing enhanced with stainless-steel 410 random packing has been developed to provide a high surface area for air–liquid contact. The contactor geometry, wettability, corrosion resistance, pressure drop, along with its CO 2 uptake efficiency, CO 2 uptake rates, and extended loading potential using potassium sarcosinate solutions are investigated. Results show that the HiDAC contactor has a relatively high specific surface area (885 m 2 /m 3 ), which allows for CO 2 uptake efficiencies of up to 75 % and capture rates of up to 550 g of CO 2 per day for a 0.3 × 0.25 × 0.3 m contactor. The contactor also exhibits high levels of wettability and corrosion resistance with amino acid-based DAC solvents. A CO 2 uptake model was developed, and modeling results are compared to experimental data to simulate and predict the performance of the contactor in a DAC process using potassium sarcosinate solvent. The system’s overall mass transfer coefficient and theoretical pressure drop were also calculated, and these results were compared to DAC data found in literature. The results presented indicate that the HiDAC contactor is well suited for DAC due to its high specific surface area, resistance to corrosion, and high degree of wettability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct air capture with amino acid solvent: Operational optimization using a crossflow air‐liquid contactor

Direct air capture (DAC) is a negative emission technology for removing CO2 from the atmosphere to maintain the CO 2 level within a reasonable range so as to address greenhouse effects. In this study, the operational optimization of lab-scale DAC has been investigated using a crossflow air-liquid contactor loaded with a three dimensionally printed Gyroid packing structure and a potassium sarcosinate solvent. The effects of various parameters, including feed air flow rate, liquid solvent flow rate, contactor geometry, and ambient temperature, are examined. The results demonstrate that the Gyroid packing design achieves comparable CO 2 capture performance to conventional packed beds but with a significantly lower pressure drop of up to 77.8%, suggesting its potential as an efficient and cost-effective solution for gas–liquid contactors in DAC. Additionally, the study explores the climate impact on CO 2 capture performance and finds that as the air temperature increases from 35 to 95°F at a fixed relative humidity of 80%, the CO 2 capture rate increased from 23.2% to 46.8% with better stability. The research highlights the importance of optimizing contactor design and operational conditions to improve the CO 2 capture rate and feasibility of DAC systems as a negative emission technology for addressing greenhouse effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Performance Air Breathing Flexible Lithium–Air Battery

Lithium–oxygen (Li–O 2 ) batteries possess the highest theoretical energy density (3500 Wh kg –1 ), which makes them attractive candidates for modern electronics and transportation applications. In this work, an inexpensive, flexible, and wearable Li–O 2 battery based on the bifunctional redox mediator of InBr 3 , MoS 2 cathode catalyst, and Fomblin-based oxygen permeable membrane that enable long-cycle-life operation of the battery in pure oxygen, dry air, and ambient air is designed, fabricated, and tested. The battery operates in ambient air with an open system air-breathing architecture and exhibits excellent cycling up to 240 at the high current density of 1 A g –1 with a relative humidity of 75%. The electrochemical performance of the battery including deep-discharge capacity, and rate capability remains almost identical after 1000 cycle in a bending fatigue test. Furthermore, this finding opens a new direction for utilizing high performance Li–O 2 batteries for applications in the field of flexible and wearable electronics.

25 ENERGY STORAGE↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Air Carbon for Algae Production (AirCAP) – Expanding algae resource potential via direct (in-pond) air-CO2 capture.

Microalgae biofuel production potential in the United States is constrained by a lack of suitable cultivation locations within a close proximity to CO2 point-sources. Initial estimates suggest that removing the requirement of a concentrated CO2 source expands resource potential ten-fold, allowing the projection of production levels that approach levels of current U.S. diesel consumption. Decoupling cultivation locations from concentrated CO2 point-sources requires direct capture of air-CO2 into the pond bulk at a rate sufficient to meet maximum expected carbon assimilation rates (10 g C/m2-day and higher). Enhancement of the ingassing rate via chemical reaction, the direct reaction of dissolved CO2 with hydroxide ions, has been proposed as a mechanism to increase the ingassing rate of air-CO2. The central objectives of this project are to validate whether chemically enhanced air-CO2 ingassing rates in large raceway ponds can meet or exceed the level required to support high levels of algae productivity, then subsequently identify alkaliphilic strains able to withstand such conditions while maintaining a biomass productivity that enables process economics. Full scale ponds (~1 acre, unlined) will be used to validate ingassing rates as a function of pH expected at scale in a series of abiotic experiments. To date, mass-transfer dynamics have been characterized in ponds ranging from 1 to 1,000 m2. Initial results will be presented describing the mass transfer coefficient in 1-acre (~4,000 m2), unlined ponds. The maximum expected carbon ingassing rate will be measured during ingassing trials, in which pond pH is displaced from equilibrium via the addition of a strong base, with the subsequent decrease in pH (and increase in dissolved inorganic carbon) corresponding to the air-CO2 absorption rate. A mass-transfer model, validated with experimental results, will be used to project ingassing rates expected at pond scales (10 acres) required for production of commodity chemicals.

09 BIOMASS FUELS↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment

Explosives are often used in industry, geology, mining, and other applications, but it is not always clear what remains after a detonation or the fate and transport of any residual material. The goal of this study was to determine to what extent intact molecules of high explosive (HE) compounds are detectable and quantifiable from post-detonation dust and particulates in a field experiment with varied topography. We focused on HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazocane), which is less studied in field detonation literature, as the primary explosive material and RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) as the secondary material. The experiment was conducted at Site 300, Lawrence Livermore National Laboratory’s Experimental Test Site, in California, USA. Two 20.4 kg and one 40.8 kg above ground explosions (primarily comprised of LX-14, an HMX-based polymer-bonded high explosive) were detonated on an open-air firing area on separate days. The complex terrain of the firing area (e.g., buildings, berm, low-height obstacles) was advantageous to study HE deposition in relation to plume dynamics. Three types of samples were collected up to 100 m away from each shot: surface swipes of aluminum plates, surface swipes of fixed objects, and filters from air samples. We used atmospheric flow tube-mass spectrometry (AFT-MS) to quantify picogram levels of molecular residue of HE material in the post-detonation dust. An aliquot of sample extract in methanol (e.g., 1 µL of 0.5 mL) was placed onto a resistive material and then thermally desorbed into the AFT-MS. We successfully detected and quantified both HMX and RDX in many of the samples. Based on mass (pg) detected and solution dilution, we back-calculated the mass collected on the swipe or filter (ng per sample). The aerial distribution of molecular residue was consistent with the path of the plume, which was strongly determined by wind speed and direction at the time of each shot. The quantity of material detected appeared to correlate more with distance from the shot and the wind conditions than with shot size. This study demonstrates that the picogram detection levels of AFT-MS are well-suited for quantification of analytes (e.g., HMX and RDX) in environmental samples.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Vertical Structure of Clouds and Precipitation During Arctic Cold–Air Outbreaks and Warm–Air Intrusions: Observations From COMBLE

The Arctic is marked by deep intrusions of warm, moist air, alternating with outbreaks of cold air down to lower latitudes. The typical vertical structure of clouds and precipitation during these two synoptic weather extremes is examined at a coastal site at 69°N in Norway. The Norwegian Sea is a corridor for warm-air intrusions (WAIs) and frequently witnesses cold-air outbreaks (CAOs). This study uses data from profiling radar, lidar, and microwave radiometer, radiosondes and other probes that were collected during the CAOs in the Marine Boundary Layer Experiment (COMBLE) between 1 December 2019 and 31 May 2020. Marine CAOs are defined in terms of thermal instability relative to the sea surface temperature, and WAIs in terms of equivalent potential temperature stratification between the surface and 850 hPa. Cloud structures in CAOs are convective, driven by strong surface heat fluxes over a long fetch of open water, with cloud tops rarely exceeding 6 km above sea level. The mostly open-cellular convection produces intermittent moderately-heavy precipitation at the observational site, notwithstanding the low precipitable water vapor (PWV). In contrast, WAIs are marked by high values of PWV and integrated vapor transport. Here, WAI clouds are synoptically driven, stratiform, with cloud tops often exceeding 5 km, sometimes layered, and generally producing persistent precipitation that can be heavier than in CAOs.

54 ENVIRONMENTAL SCIENCES↗

Air resonance enhanced multiphoton ionization tagging velocimetry

Air resonance enhanced multiphoton ionization (REMPI) tagging velocimetry (ART) was demonstrated in quiescent and supersonic flows. The ART velocimetry method utilizes a wavelength tunable laser beam to resonantly ionize molecular oxygen in air and generate additional avalanche-type ionization of molecular nitrogen. The fluorescence emissions from the first negative and first positive bands of molecular nitrogen are, thus, produced and used for flow tagging. Detailed characterization of ART was conducted, including the effects of oxygen resonance to fluoresce nitrogen, nitrogen fluorescence spectrum, laser energy deposition into quiescent flow showing minimal perturbations in flow, fluorescence lifetime study at various pressures, and line tagging without breakdown. Pointwise velocity measurements within a supersonic flow from a nominal Mach 1.5 nozzle have been conducted and characterized.

Clark, Aleksander↗