Search NASA⌕ Search

SEARCH · Search NASA

Results for “air ducts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Customer outcomes in Pay-As-You-Save programs

We review the energy and financial outcomes of households participating in several programs based on successive versions of the Pay As You Save¯ (PAYS¯) system. PAYS¯ programs offer non-debt financing for energy efficiency (and sometimes other technologies) in residential buildings through a tariff attached to the home’s utility meter, designed to be offset by project savings. We find that the five programs we study generally serve customers living in zip codes with levels of income and education below the national average and unemployment rates above the national average, demonstrating their potential to improve equity in energy efficiency adoption. Using weather-normalized analysis of energy consumption data, we show that most customers of Midwest Energy’s program reduce annual electricity and gas consumption, averaging 15% and 26% reductions respectively. Changes in energy consumption calculated using this method represent a combination of project effects and changes in occupant behavior. These results are similar to existing analyses of PAYS¯ programs in North Carolina, Arkansas, and Tennessee. About half of participating Midwest households generate sufficient energy cost savings to cover their monthly tariff. Various factors, including changes in occupant behavior, program error, causes independent of the customer or program, or some combination thereof may explain lower-than-expected cost reductions in some projects. Given the inherent variability in annual household electricity consumption, we feel these programs are enabling energy efficiency improvements and their attendant co-benefits, including occupant health and comfort and reduced carbon emissions, while reasonably balancing energy savings and tariff costs. Pairing PAYS¯ with additional financial assistance, as well as promoting cost-effective measures such as air and duct sealing, could further broaden program participation by enabling additional projects to meet PAYS¯ program eligibility rules.

Deason, Jeff↗

ResStock Measure Documentation: Light Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Light Envelope" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Low-Cost Aero Technology Demonstrations

The main focus of this work was to demonstrate the use of polymeric additive manufacturing (AM) to create tooling for both preforming and consolidation. Polymeric tooling was utilized where both modest and higher pressures are used for part consolidation. The key focus for the AM tooling development was for fabrication of complex structures such as ducting, C-channel stiffened skins, and airfoils where conventional male tooling would typically be trapped in the cured part. The AM tooling was evaluated for use as a tool master used to fabricate and re-shape deformable/re-formable mandrels based on SpinTech’s shape memory composite technology known as Smart Tooling. The AM tooling was also evaluated for use as a mold for composite infusion and consolidation. Key performance parameters were tracked for project schedule completion with each step comprising of “art to part” cycle time, cost, and model fidelity for dimensions, performance, and cost. The primary focus of this demonstration was to determine if a 50% cost reduction was achievable, for each AM tooling-set, as compared to conventional processes. UDRI leveraged project partner SpinTech, who manufactures tools and parts in these categories and thus provided a baseline regarding current best practices and provided valuable feedback during the entirety of this demonstration. This demonstration primarily focused on the use of AM tooling for fabrication of three composite component structures which are typically utilized in aircraft and comprise salient geometric features of broad interest. These components are often tooling intensive and have features requiring extraction of male tools which are usually trapped by the geometry. The three structures selected by the team included: 1) A one-piece airfoil shell comprised of compound contours where male tooling would be trapped unless the part were manufactured in two halves as is typically the case. 2) A one-piece duct used for air handling, comprised of compound contours where male tooling would be trapped unless the part were manufactured in two halves, or a washout mandrel were to be used. 3) A co-cured C-channel stiffened skin where typically C-channels would be individually manufactured and then bonded to a cured skin. The demonstration was comprised of three main tasks: • Task 1: AM Tool Feasibility Study – ensure the AM tooling meets the performance requirements as specified by SpinTech to match baseline performance. • Task 2: Complex Tool Demonstration – Fabricate tooling, preforms, and parts representative of an airfoil and duct. • Task 3: Large Aerostructure Fabrication Demonstration – Fabricate tooling, preforms, and part representative of a C-channel stiffened skin. With the conclusion of this project, a decision tree was developed to determine the key considerations necessary to determine if use of AM tooling for the three selected structures was able to attain the same quality as historically achieved on metallic tooling, while providing a significant cost reduction.

36 MATERIALS SCIENCE↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SO3/H2SO4 continuous real-time sensor demonstration at a power plant

We present results from field testing of a new, innovative sensor developed to measure SO3/H2SO4 continuously and in real time at a coal-fired power plant. The system utilizes the sensitivity, specificity, and real-time capabilities of mid-infrared (Mid-IR) laser-based sensor technology, along with a heated, close-coupled cell mounted directly to a power plant duct. Measurements were made by the laser sensor over a 2-day period and compared to results from the accepted method, EPA 8A, which requires a 30-minute collection, labor intensive processing, and off-site analysis at a lab. In contrast to the condensation method, the laser sensor continuously samples flue gas and reports measurements of the concentration of SO3/H2SO4, SO2 ever second with unattended operation. This initial demonstration proved the sensor concept and paves the way for its use for optimizing sorbent injection used to neutralize SO3/H2SO4. Optimized sorbent injection will enable significant cost savings associated with efforts to mitigate the presence and effects of SO3/H2SO4 such as “Blue Plume”, air heater fouling, and duct corrosion. In particular, the real-time, actionable information will enable better control of additive injection in flex conditions and variable fuels.

20 FOSSIL-FUELED POWER PLANTS↗

Room Return Path Sensitivity

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms. In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology–or layout–impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This report considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated heat and energy recovery ventilator system

A heat recovery ventilator (HRV) and/or energy recovery ventilator (ERV) that integrates with a residential capacity air handling unit (AHU) is embodied in a small footprint HRV or ERV unit that connects directly to the return side of an AHU and to outdoor air inlet and exhaust ducts. The ventilator includes a control system incorporating a processor and sensors that control the operation of the system to provide desired ventilation flow rates under varying conditions.

Puttagunta, Srikanth↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel, Simplified Air Delivery System Design Gets Commercialized

Typical air delivery systems require contractors to design systems that are complex, difficult to integrate into the framing and structural components of a home, and often do not meet the optimization demands of newer energy-efficient homes. This complex process can be a burden to already strained construction labor costs. However, a new technology simplifies duct system design to improve comfort and eliminate sources of installation error for residential air delivery systems.

30 DIRECT ENERGY CONVERSION↗

Observations of Offshore Internal Boundary Layers

The growth of the marine internal boundary layer (MIBL, height h i ) with the shore-normal distance x, is a topic of continuing interest because of its applications in coastal dispersion, offshore wind farm siting, coastal air-sea fluxes and in evaporative ducting. Available data on MIBL are only scarce, given its difficult to measure the variability of coastal winds. During Coupled Air-Sea Processes and Electromagnetic Research (CASPER) campaigns an array of instrumentation was deployed to measure offshore spatial variability and its effect on electromagnetic wave propagation. Meteorological sensors (flux towers and remote sensing) were deployed along the coast of Point Mugu, California, on a research vessel and FLoating Instrument Platform (FLIP) provided surface layer and boundary layer observations. In this article, measurements from multiple remote sensing instruments, such as synchronized triple Doppler lidars, small boat operations with tethered lifting system, and radiosondes provide a holistic view of the MIBL growth and its spatial variability from the coast. A convective and stable MIBL observed during two intensive operating period days showed distinct growth characteristics off the coast of Point-Mugu. During stable stratified atmospheric conditions, an MIBL was observed at least up to 47 km from the coast. The growth of the MIBL within the nearshore adjustment zone was influenced by surrounding atmospheric, oceanographic, and topographic conditions. A new parameterization scheme is developed based on advection-diffusion balance equations accounting for upstream turbulence and compared with h i observations from Doppler lidar and profiles from small boat. An evaluation of existing IBL theories was also conducted.

54 ENVIRONMENTAL SCIENCES↗

Fuel cells for single-aisle regional aircraft: System configuration, performance and cost

A hydrogen fuel cell propelled electric aircraft can compete with incumbent turbofan technologies for single-aisle regional aircraft by coupling design of stack, air handling, thermal management, propulsion, and airframe to optimize performance. The stack operates at 95°C to facilitate heat rejection during take-off and below 75°C during cruise to extend lifetime and is oversized to satisfy power requirements at end of life. A multi-stage turbocompressor with a compression ratio >10 is selected to reach high stack power density at 11,300-m cruise altitude. The propulsion system is configured to accommodate air handling within the core duct, an inclined heat exchanger in the outer duct to limit the nacelle size, and variable area nozzles to independently control mass flows through the core and bypass ducts. The airframe is modified for maximum lift coefficient and longer balanced field length for dramatically reduced thrust during take-off, and the fuselage is stretched by 20% to store liquid hydrogen (LH 2 ). Modularization of power systems promotes safety in one engine inoperative scenarios and allows reaching specific power metrics for stack, balance-of-plant and fuel cell system (FCS), necessary for acceptable take-off weight. In conclusion, cost parity requires increase in FCS lifetime, LH 2 cost reduction, and improved FCS specific power.

Catalyst durability↗