Intensive care alarm indicator system Final technical report, 22 Jun. - 28 Aug. 1970
Intensive care alarm indicator system with audible signal and worn by staff responsible for care
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Intensive care alarm indicator system with audible signal and worn by staff responsible for care
Alarm system design for monitoring one or more relay cicuits
Signaling summary alarm circuit with semiconductor switch for faulty contact indications
Automatic device which attaches to an active television set sounds an audible alarm when a tornado is within 29 km (18miles) of device.
Portable detector tests rate-of-rise temperature devices. Incandescent light bulb is calibrated to produce rate of temperature rise necessary to activate properly functioning alarm.
Description of the aerodynamic molecular beam testing performed on the near earth spacecraft temperature alarm system that is designed to provide in-flight temperature information useful for safeguarding scientific equipment during perigee maneuvers. The temperature/heat flux calibration results obtained are summarized.
The OMEGA Position Location Experiment (OPLE) was performed in 1967 by the Goddard Space Flight Center in order to demonstrate a position location and data collection system. OMEGA navigation signals were received at a remote site and retransmitted via a synchronous satellite to a ground processing center where data collecting and position determination were performed. Recent technological advances have made it possible to develop an Advanced OPLE System towards a global search and rescue application. This application generated some new problem areas such as the OMEGA lane ambiguity, random access, location accuracy, real-time processing, and size and weight of the Search and Rescue Communications (SARCOM). This experiment demonstrates the feasibility of instantaneous alarm and position location by using a relatively inexpensive, battery operated, three-pound package.
Monitor/alarm with audio and visual warning output can be used to warn when prescribed limits of temperature, liquid level, pressure, or similar properties are exceeded. Device is more compact, lighter, and less expensive to manufacture than typical alarm circuits.
A highly efficient computer program, called ALARM, for the determination of eigenvalues and eigenvectors of large symmetric matrices (over 10,000 degrees of freedom), was described. As such, it is highly useful for analyzing complex finite element and finite difference idealizations encountered in structural dynamics and acoustic probelms. The program is based upon a scheme which reduces a large matrix to an equivalent tridiagonal one of much smaller size. The main strength of the algorithm lies in its ability to retain all the information required to obtain the eigenvalues at either end of the original matrix spectrum.
The performance of the Geostationary Lightning Mapper has been evaluated through comparison with other satellite lightning sensors and ground-based networks. However, because the performance of these reference sensors is both imperfect and imperfectly known, the true performance of GLM can only be estimated through such a process. In particular, GLM performance metrics such as detection efficiency (DE) and false alarm rate (FAR) retrieved through comparison with reference networks are affected by those networks’ own DE, FAR, and spatiotemporal accuracy, as well as the selected flash matching criteria. This study presents follow-on results from an ongoing analysis that uses a Monte Carlo simulation-based inversion technique to quantify the effect on retrieved GLM performance of a reasonable range of reference network DE, FAR, spatiotemporal accuracy, and the associated geographic patterns of each. These results help quantify and bound the actual performance of GLM and the attendant uncertainties when comparing GLM to imperfect reference networks.
We present a study on the effectiveness of ExoMiner against False Alarms in Kepler data. ExoMiner is a deep learning model that was used to validate around 370 Kepler Objects of Interest. We follow the analysis conducted in Coughlin et al (2017) “DR25 Robovetter Completeness and Effectiveness” for Robovetter, a rule-based model used to vet TCEs for this data release and automatically generate the Q1-Q17 DR 25 KOI Table. The ExoMiner model is trained on observed transit data from Kepler Q1-Q17 DR25 and evaluated on Kepler inverted and scrambled data. The results provide a more comprehensive insight into the capacities and limitations of ExoMiner, especially the vetting of not-transit-like signals and, more generally, the use of deep learning models to model transit photometry data for vetting and validation purposes.
Inductive loop has been added to commercially available call system fitted with earphone receiver. System transmits high frequency signals to nurse's receiver to announce patient's need for help without disturbing others.
An emergency alert system is described. In a school each classroom (or other area) is instrumented with a hidden microphone and receiver tuned to a non-audible frequency. The receivers' outputs are connected to a central display unit in the school's administrative office. Each instructor is provided with a small concealable transmitter which, when hand activated by the instructor upon the occurrance of any emergency, generates a non-audible signal at the receiver's tuned frequency.
Explore the source record for details and available documents.
An instrument designed to fly on the Atmosphere Explorer-C (AE-C) spacecraft is described which is to provide a thermal measurement indicative of the temperature of the low mass elements, thus providing information to assist in the decision process regarding real time perigee maneuvers. Also described is the method of achievement of two additional design goals, an indication of the altitude at which aerodynamic heating begins to take place, and a quantitative measure of the aerodynamic flux. Provision of such an instrument obviated the need for very costly and very difficult simulation of the aerodynamic heating during thermal vacuum testing.
Conjugated polyacetylene polymers and one condensation polyene, all containing a high degree of conjugated unsaturation, were synthesized. These polymers were characterized by chemical analysis and by thermogravimetric analysis, as well as for their film-forming capability and gas/polymer interactions. It was found that those that had a high degree of conjugated unsaturation and had resonance - stabilizing groups were very thermally stable to 200 C, e.g., poly(dicyanoacetylene), poly(ethynylferrocene) and poly(phenylacetylene); while those with labile moieties, such as poly(p-formamidophenylacetylene), among others, suffered some degradation when heated in air. When subjected to gas/polymer interaction effects, the greatest change in electrical conductance was observed when ammonia was used as the gas and poly(p-nitrophenylacetylene) was the detector. Other polymers showed similar behavior. For example, poly(ethynylcarborane), considered to be an electron acceptor also showed a change in electrical conductance when exposed to ammonia, while poly(ethynylpyridine) and poly(ethylidenepyridazine) responded to carbon monoxide. However, for "fire gases" (gases from smoldering cotton), poly(ethynylferrocene) was the most responsive. Thus, the concept of polymers with different electronegativities forming charge-transfer complexes with different gases was found to be operable.
The electrical resistivities were investigated of some polymers known to be enhanced by the presence of certain gases. This was done to make a device capable of providing early warning to fire through its response with the gases produced in the early phases of combustion. Eight polymers were investigated: poly(phenyl acetylene), poly(p-aminophenyl acetylene), poly(p-nitrophenyl acetylene), poly(p-formamidophenyl acetylene), poly(ethynyl ferrocene), poly(ethynyl carborane), poly(ethynyl pyridine), and the polymer made from 1,2,3,6 tetramethyl pyridazine. A total of 40 usable thin-film sandwich devices and a total of 70 usable interdigitated-electrode lock-and-key devices were fabricated. The sandwich devices were used for measurements of contact linearity, polymer conductivity, and polymer dielectric constant. The lock-and-key devices were used to determine the response of the polymers to a spectrum of gases that included ammonia, carbon nonoxide, carbon dioxide, sulfur dioxide, ethylene, acrolein, water vapor, and normal laboratory air. Strongest responses were to water vapor, ammonia, and acrolein, and depending on the polymer, weaker responses to carbon dioxide, sulfur dioxide, and carbon monoxide were observed. A quantitative theory of device operation, capable of accounting for observed device leakage current and sensitivity, was developed. A prototype detection/alarm system was designed and built for use in demonstrating sensor performance.
The GRAN Experiment is designed to prove a world-wide search and rescue (SAR) system utilizing Omega navigation system signals and geo-synchronous satellites. In order to develop a SAR system, the original NASA Omega Position Locating Equipment (OPLE) experiments have been expanded by the Naval Air Test Center, Patuxent River. Specifically, a fourth frequency (10.880 KHz) has been added experimentally to two Omega transmitters. This will increase line of position (LOP) ambiguities from 72 nautical miles to 360 nmi apart. Algorithms have been developed to resolve the 360 nmi ambiguities. During September and October 1974, two series of tests were conducted with Lincoln Experimental Satellite 6 (LES-6) to demonstrate the position locating potential of the four-frequency Omega concept.