Search NASA⌕ Search

SEARCH · Search NASA

Results for “alternative water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evolution of Electric Sector Water Use Under Alternative Electricity Futures

Increasing competition for water resources in the United States could create future challenges for allocating and using thermal cooling water in the U.S. electric power sector. While thermal power plant retirements and the growth of wind and solar technologies can reduce national aggregate power sector cooling water use, local water constraints and growing demand for agricultural or municipal supply could create greater needs for higher-cost alternative water supplies such as groundwater or recycled wastewater. For some regions, these incentives could change future electricity planning and operational decisions. These relationships and impacts are studied here using the National Renewable Energy Laboratory (NREL) Regional Energy Deployment System (ReEDS), a national electric sector planning model that has recently been upgraded to include a highly detailed representation of thermal cooling water demand and supply. Thermal power technologies are differentiated by both cooling technology and water source type to track and constrain thermal cooling water use in a way that incorporates both physical and legal water considerations in the United States. This capability is exercised under a range of electricity sector futures with alternative technology costs, fuel prices, and water constraints to illustrate ways that U.S. electric sector water use could evolve under uncertain future electric sector drivers. In exploring changes to regional generation and transmission planning and operation, water requirements, and cost, we highlight the environmental and economic impacts of future power sector water decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Oil and Gas Produced Water Reuse: Opportunities, Treatment Needs, and Challenges

Advances in water treatment technologies paired with potential restrictions on oil and gas (O&G) produced water disposal could incentivize the beneficial reuse of treated produced water in the O&G industry. However, the remote nature of O&G operations limits the applicability of many of these solutions, which may be spatially inefficient, require operator supervision, or are ill-suited for the complex nature of produced water. Furthermore, the responsible, sustainable reuse of produced water as an alternative water source requires standardized analytical techniques for characterizing and determining the toxicity of treated produced water and improving our understanding of the fate and transport of various constituents. In the past decade, we made little progress in economically treating produced water for beneficial reuse outside of oilfield operations; the sole major breakthrough has been in the development of salt-tolerant fracturing chemicals that allow for reuse of produced water for fracking operations. Guided research should assist in the development of fit-for-purpose solutions to maximize the reuse of treated produced water. This is exemplified by the case studies presented here that detail currently operating treatment facilities for reclamation and reuse of produced water.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic analysis of the water, energy, and greenhouse gas emissions impacts from the adoption of water efficiency practices in the U.S. manufacturing sector

Water is a critical resource for all of manufacturing. As such, mitigating risks to the supply of water to manufacturing plants facilitates maintaining a vital manufacturing sector. Reductions in water use through water efficiency is one method for mitigating risk, however little is known about its potential in the United States (U.S.) manufacturing sector. Herein, we address this gap and calculate the water reduction potential in U.S. manufacturing from commercially available water efficiency opportunities specific to the manufacturing sector. A list of water efficiency measures specific to the manufacturing sector is compiled and applied to estimates of U.S. manufacturing water withdrawals. The energy and carbon dioxide equivalent (CO 2 e) emission impacts from implementation of these measures are also quantified to better inform the resource, environmental, and economic trade-offs from implementation of these measures. We find that the water savings potential from the evaluated measures is up to 60 percent of U.S. manufacturing water withdrawal for certain subsectors, with the energy and emissions impact dependent on the measure. Further, we calculate the levelized cost of conserved water for several water efficiency measures (-$\$4,000$ to $\$85$/thousand m 3 , where negative values indicate net cost savings and positive values indicate net cost expenditures) and compare them to the levelized cost of alternative water sources ($\$600$ to $\$3,400$/thousand m 3 ). The results show significant opportunities for water and energy use reductions at levelized costs at least one order of magnitude lower than alternative water supplies, with some being revenue-generating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next Generation Life Support Project: Development of Advanced Technologies for Human Exploration Missions

Next Generation Life Support (NGLS) is one of several technology development projects sponsored by the National Aeronautics and Space Administration s Game Changing Development Program. NGLS is developing life support technologies (including water recovery, and space suit life support technologies) needed for humans to live and work productively in space. NGLS has three project tasks: Variable Oxygen Regulator (VOR), Rapid Cycle Amine (RCA) swing bed, and Alternative Water Processing. The selected technologies within each of these areas are focused on increasing affordability, reliability, and vehicle self sufficiency while decreasing mass and enabling long duration exploration. The RCA and VOR tasks are directed at key technology needs for the Portable Life Support System (PLSS) for an Exploration Extravehicular Mobility Unit (EMU), with focus on prototyping and integrated testing. The focus of the Rapid Cycle Amine (RCA) swing-bed ventilation task is to provide integrated carbon dioxide removal and humidity control that can be regenerated in real time during an EVA. The Variable Oxygen Regulator technology will significantly increase the number of pressure settings available to the space suit. Current spacesuit pressure regulators are limited to only two settings while the adjustability of the advanced regulator will be nearly continuous. The Alternative Water Processor efforts will result in the development of a system capable of recycling wastewater from sources expected in future exploration missions, including hygiene and laundry water, based on natural biological processes and membrane-based post treatment. The technologies will support a capability-driven architecture for extending human presence beyond low Earth orbit to potential destinations such as the Moon, near Earth asteroids and Mars.

Barta, Daniel J.↗

Robust Carbon Dioxide Plume Imaging Using Joint Tomographic Inversion of Seismic Onset Time and Distributed Pressure and Temperature Measurements (Final Report)

We develop and demonstrate rapid and cost-effective methodologies for spatiotemporal tracking of CO2 plumes during geologic sequestration using joint inversion of seismic data and distributed pressure and temperature measurements. Key elements of our methodology are: (a) a computationally efficient approach to pressure and temperature propagation, (b) analysis of time lapse seismic data using a novel ‘seismic onset time’ approach to detect fluid front propagation, and (c) data assimilation and uncertainty assessment via joint inversion of pressure, temperature and time lapse seismic data, and (d) validating the numerical tomographic inversion using a CO2 injection demonstration projects, specifically data collected from the from the Petra Nova Parish Holdings CCUS project in the West Ranch Field, Texas and the Chester-16 reef CO2 injection site in Northern Michigan which is part of the DOE Midwestern Carbon Sequestration Project. The research team is led by Texas A&M University and includes Battelle as a subcontractor with support from Shell, Anadarko, Chevron and JX Nippon. A carbon dioxide (CO2) water-alternating-gas (WAG) pilot was conducted to gain insights into tertiary oil recovery potential via CO2 flood in the West Ranch Field as part of the Petra Nova project, the world’s largest post-combustion CO2 capture and utilization initiative. With a fluvial formation geology and large contrasts in permeability, this is a challenging and novel application of CO2 enhanced oil recovery (EOR). We build a predictive dynamic model of the subsurface that incorporates the multiphase and compositional data acquired during the pilot operation. The calibrated model is used for the carbon dioxide plume imaging. The study began with an initialization of the pilot sector model extracted from a calibrated full-field model. The pilot model calibration follows a two-step hierarchical workflow. First, we performed a large-scale update of the permeability distribution by integrating available bottomhole pressure and multiphase production data. In the second step, local permeability field is fine-tuned using a streamline-based method to match CO2 breakthrough times at the producers. The predictive capability of the calibrated model was verified through two blind validation tests: (1) the model showed good agreement with saturation logs acquired at two observation wells; and (2) the model reproduced the CO2 recovery as a fraction of the injected CO2. The use of seismic onset times has shown great promise for integrating near-continuous seismic surveys for updating geologic models. In this study, we analyze the impact of seismic survey frequency on the onset time approach aiming to extend the application of onset time to infrequent seismic surveys. In addition, we quantitatively examine the nonlinearity of the onset time method and compare it to the commonly used amplitude inversion method. We carry out a sensitivity analysis of seismic survey frequency based on the complete seismic survey data (over 175 surveys) of steam injection in a heavy oil reservoir (Peace River Unit) in Canada. Our results show that an adequate onset time map can be obtained from the infrequent seismic surveys by interpolation between seismic surveys as long as there is no change in the dominant underlying physics between the successive surveys. The study also shows that nonlinearity of the onset time method can be -smaller than that of the amplitude inversion method by several orders of magnitude. Application to the Brugge benchmark case shows that the onset time method obtains comparable permeability update as the traditional seismic amplitude inversion method with faster computation and improved convergence characteristics. We extend the streamline-based data integration approach to incorporate distributed temperature sensor (DTS) data using the concept of thermal tracer travel time. Then, a hierarchical workflow composed of evolutionary and streamline methods is employed to jointly history match the DTS and pressure data. Finally, CO2 saturation and streamline maps are used to visualize the CO2 plume movement during the sequestration process. The hierarchical workflow is applied to a carbon sequestration project in a carbonate reef reservoir within the Northern Niagaran Pinnacle Reef Trend in Michigan, USA. The monitoring data set consists of distributed temperature sensing (DTS) data acquired at the injection well and a monitoring well, flowing bottom-hole pressure data at the injection well, and time-lapse pressure measurements at several locations along the monitoring well. The history matching results indicate that the CO2 movement is mostly restricted to the intended zones of injection which is consistent with an independent warm-back analysis of the temperature data. In addition to employing simulation models and inverse methods for CO2 plume imaging, we also initialized a data-driven technology for detecting inter-well connectivity based on production and pressure data. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO2 EOR projects utilizing the water-alternating-gas (WAG) process. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. Texas A&M University, the lead organization in the project, was primarily responsible for the development of tomographic approaches for CO2 plume mapping in conjunction with distributed pressure, temperature and seismic onset time data. Battelle, as a subcontractor, was primarily responsible for the development of analytical and empirical methods for analyzing transient injection rate and pressure data from point/line sources such as injection and monitoring wells. An additional area of emphasis for Battelle was the use of machine learning for such tasks as inferring reservoir connectivity information from injection-production data, and identifying variable importance for machine learning-based proxy models developed from full-physics simulations. The two organizations also collaborated on the application of the tomographic inversion methodology for a field data set.

02 PETROLEUM↗

Mine Water Use, Treatment, and Reuse in the United States: A Look at Current Industry Practices and Select Case Studies

Mining provides significant economic value while often impacting local water supplies and environments because of freshwater usage and waste disposal practices. In this paper we identify current practices in mine water, including how water is used in mining, influent and effluent water quality, treatment technologies, and end uses with the goal of informing future research on implementable, reliable, and cost-effective advanced water treatment in the mining sector. This study also reviews the available literature to broadly evaluate mining in the United States and performs a techno-economic assessment on water use and disposal for three detailed case studies applicable to lithium, uranium, and copper mines. These case studies highlight specific industry examples of distinct extraction methods, geographical regions, and mined commodities. Hypothetical scenarios based on case study baselines revealed potential impacts to mine water available for beneficial reuse through the use of novel water treatment technologies and alternate water management strategies. Finally, an assessment of national level impacts resulting from the reuse of treated mine source water is presented.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plant functional types broadly describe water use strategies in the Caatinga, a seasonally dry tropical forest in northeast Brazil

In seasonally dry tropical forests, plant functional type can be classified as deciduous low wood density, deciduous high wood density, or evergreen high wood density species. While deciduousness is often associated with drought-avoidance and low wood density is often associated with tissue water storage, the degree to which these functional types may correspond to diverging and unique water use strategies has not been extensively tested. We examined (a) tolerance to water stress, measured by predawn and mid-day leaf water potential; (b) water use efficiency, measured via foliar δ 13 C; and (c) access to soil water, measured via stem water δ 18 O. We found that deciduous low wood density species maintain high leaf water potential and low water use efficiency. Deciduous high wood density species have lower leaf water potential and variable water use efficiency. Both groups rely on shallow soil water. Evergreen high wood density species have low leaf water potential, higher water use efficiency, and access alternative water sources. These findings indicate that deciduous low wood density species are drought avoiders, with a specialized strategy for storing root and stem water. Deciduous high wood density species are moderately drought tolerant, and evergreen high wood density species are the most drought tolerant group. Our results broadly support the plant functional type framework as a way to understand water use strategies, but also highlight species-level differences.

54 ENVIRONMENTAL SCIENCES↗

Federal Water Management Planning Manual

This Federal Water Management Resource Guide provides direction to Federal agencies on how optimize water use at Federal facilities, use water balance analysis methods, identify design elements and procurement best practices, and expand use of alternative water. It provides best practices for managing water to be considered when developing or improving an effective facility water management program. PNNL developed this guide for the Federal Energy Management Program (FEMP). FEMP was directed by the Council on Environmental Quality (CEQ) to develop a Federal Water Management Resource Guide per the Implementing Instructions for Executive Order (E.O.) 13834, Efficient Federal Operations. This document serves to satisfy this requirement in order to provide best water management practices within the Federal Government.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal Water Management Planning Manual

This Federal Water Management Resource Guide provides direction to Federal agencies on how optimize water use at Federal facilities, use water balance analysis methods, identify design elements and procurement best practices, and expand use of alternative water. It provides best practices for managing water to be considered when developing or improving an effective facility water management program. PNNL developed this guide for the Federal Energy Management Program (FEMP). FEMP was directed by the Council on Environmental Quality (CEQ) to develop a Federal Water Management Resource Guide per the Implementing Instructions for Executive Order (E.O.) 13834, Efficient Federal Operations. This document serves to satisfy this requirement in order to provide best water management practices within the Federal Government.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical, Economic, Energetic, and Environmental Evaluation of Pretreatment Strategies for Scaling Control in Brackish Water Desalination Brine Treatment

Effective pretreatment is essential for achieving long-term stable operation and high water recovery during the desalination of alternative waters. This study developed a process modeling approach for technical, economic, energetic, and environmental assessments of pretreatment technologies to identify the impacts of each technology treating brackish water desalination brine with high scaling propensity. The model simulations evaluated individual pretreatment technologies, including chemical softening (CS), chemical coagulation (CC), electrocoagulation (EC), and ion exchange (IX). In addition, combinations of these pretreatment technologies aiming at the effective reduction of key scaling constituents such as hardness and silica were investigated. The three evaluation parameters in this assessment consist of levelized cost of water (LCOW, $/m 3 ), specific energy consumption and cumulative energy demand (SEC|CED, kWh/m 3 ), and carbon dioxide emissions (CO 2 , kg CO 2-eq /m 3 ). The case study evaluated in this work was the desalination brine from the Kay Bailey Hutchison Desalination Plant (KBHDP) with a total dissolved solids (TDS) concentration of 11,000 mg/L and rich in hardness and silica. The evaluation of individual pretreatment units from the highest to lowest LCOW, SEC|CED, and CO 2 emissions in the KBHDP brine was IX > CS > EC > CC, CS > IX > EC > CC, and CC > CS > EC > IX, respectively. In the case of pretreatment combinations for the KBHDP, the EC + IX treatment combination was shown to be the best in terms of the LCOW and CO 2 emissions. The modeling and evaluation of these pretreatment units provide valuable guidance on the selection of cost-effective, energy-efficient, and environmentally sustainable pretreatment technologies tailored to desalination brine applications for minimal- or zero-liquid discharge.

14 SOLAR ENERGY↗

Investigation of enhanced CO 2 storage in deep saline aquifers by WAG and brine extraction in the Minnelusa sandstone, Wyoming

Geological CO 2 sequestration in deep saline aquifers has been extendedly investigated to reach the goal of carbon neutral as large amount of CO 2 can be reduced in a short time. Here, this study investigates the feasibility of water-alternating-gas (WAG) injection and brine extraction on enhancing CO 2 storage in a target deep saline aquifer, Minnelusa Sandstone in the Powder River Basin (PRB) of Wyoming. An integrated numerical model is developed to account for four scenarios: (1) CO 2 continuous injection (CI) through one injection well, (2) WAG injection through one injection well, (3) CO 2 CI through one injection well and brine extraction through one producer, (4) WAG injection through one injection well and brine extraction through one producer. Simulation results suggest that WAG injection and brine extraction corporately make it possible to enhance CO 2 injectivity while securing CO 2 storage safety. For instance, WAG injection considerably reduces structural trapping contribution while enhances dissolved and residual trapping contributions. As for brine extraction, it can decrease the maximum averaged reservoir pressure by 37% and 22% for CI and WAG injection, respectively. Besides, sensitive analyses of the operational parameters for the fourth scenarios are performed. Results reveal that, when the amount of total CO 2 injection has been predetermined, CO 2 injection time and rate within each period of WAG should be small whereas it is preferable to have large water injection time and rate. This is to secure desirable dissolved and residual trapping contributions (store CO 2 with safety). Sensitive degree results confirm that CO 2 injection rate, water injection time, and CO 2 injection time of WAG injection exhibit significant effects on CO 2 storage whereas the impacts of producer bottom-hole pressure (BHP), water injection rate, and CO 2 -water injection time are relatively weaker. This study not only sheds light on achieving double-win goal: enhance CO 2 injectivity and store CO 2 with safety, but also can be a critical reference for other CO 2 storage in deep saline aquifers.

58 GEOSCIENCES↗

Contributions of the Siberian shelf polynyas to the Arctic Ocean intermediate and deep water

To investigate the role of Siberian Shelf polynyas in water mass formation, and that of Whalers Bay in the cooling of the West Spitsbergen Current, satellite observations from the Nimbus 7 scanning multichannel microwave radiometer are used to determine the size and location of polynyas for November-March, 1978-1982. If salt contributes only to the Arctic Intermediate Water, the results show that the continental shelves can produce 20-60 percent of this water. Alternatively, if the salt contributes only to the deep water of the Eurasian Basin, then without consideration of the mixing of the bottom water with the Greenland and Norwegian Sea water, the contribution from the shelves yields a renewal time of about 100 years. These results imply that there is insufficient water produced in the shelf polynyas to perform all of the roles that have historically been assigned to it.

Martin, Seelye↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MaxTech HPWH Using Ultra-low GWP Refrigerant

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of superior performance compared with that of alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, significant interest exists for deploying low global warming potential refrigerants to minimize environmental impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Treatment: Are Membranes the Panacea?

Alongside the rising global water demand, continued stress on current water supplies has sparked interest in using nontraditional source waters for energy, agriculture, industry, and domestic needs. Membrane technologies have emerged as one of the most promising approaches to achieve water security, but implementation of membrane processes for increasingly complex waters remains a challenge. The technical feasibility of membrane processes replacing conventional treatment of alternative water supplies (e.g., wastewater, seawater, and produced water) is considered in the context of typical and emerging water quality goals. This review considers the effectiveness of current technologies (both conventional and membrane based), as well as the potential for recent advancements in membrane research to achieve these water quality goals. We envision the future of water treatment to integrate advanced membranes (e.g., mixed-matrix membranes, block copolymers) into smart treatment trains that achieve several goals, including fit-for-purpose water generation, resource recovery, and energy conservation.

catalysis (heterogeneous)↗

High Temperature Stability of Aqueous Foams for Potential Application in Enhanced Geothermal System (EGS)

Enhanced Geothermal Systems (EGS) are typically constructed by injecting high-pressure water into the deep hot dry rocks (HDR) under carefully controlled conditions to create new or re-open existing fractures, which usually utilizes an immense quantity of water. Alternatively, aqueous foam-based fracturing fluids may offer potential advantages over conventional water-based fracturing fluid, including reduced consumption of water and environmental impact. Although foam-based fracturing has shown promising results in oil and gas industries, its applicability to EGS is unknown. Foams are complex mixtures of liquids with gaseous phases that are thermodynamically unstable. Their stability will decrease over time due to liquid drainage, bubble coarsening, and coalescence. Therefore, it is essential to stabilize foam fluids at high temperatures for EGS related applications such as fracking of HDRs.This paper is focused on investigating high-temperature stability of N2-in-water or N2 foams containing different surfactants and stabilizing agents. Foam stability was characterized by the half-life, which is defined as the time a foam decreases to 50% of its original height due to drainage. Surfactants with various concentrations dissolved in deionized water were investigated, including alfa olefin sulfonate (AOS), sodium dodecyl sulfonate (SDS), TergitolTM (NP – 40), and cetyltrimethylammonium chloride (CTAC). Also, the effects of other stabilizing agents, including guar gum, bentonite clay, crosslinker, graphene oxide (GO) dispersion on foam stability were tested. Initial results showed that foam stability decreased dramatically as temperature increased. On the other hand, foams became relatively more stable as pressure increased. Certain stabilizing agents, such as guar gum and crosslinker, can enhance foam stability at a wide range of temperatures. Our results indicate that it may be possible to obtain stable foams at high-temperature, high-pressure conditions with appropriate stabilizing agents.

Thakore, Virensinh↗