Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The stability of weakly ionized collisional dusty plasma in the presence of flow

The stability of weakly ionized and magnetized plasma in the presence of transverse (to the magnetic field) neutral wind is investigated in the present work. The collisional coupling of ambient background flow to the magnetized plasma gives rise to an electric field. In the presence of charged unmagnetized dust, electrostatic fluctuations in such plasma become unstable, with the growth rate dependent on the plasma thermal speed as well as on the dust charge and collision frequencies. This instability is similar to the Farley-Buneman instability. However, unlike Farley-Buneman, where the growth rate is directly dependent on the background flow, this dependence in the present case is only indirect. It is shown that this instability can grow over few seconds in the Earth's lower ionosphere and thus could play an important role in the structure formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inviscid evolution of large amplitude filaments in a uniform gravity field

The inviscid evolution of localized density stratifications under the influence of a uniform gravity field in a homogeneous, ambient background is studied. The fluid is assumed to be incompressible, and the stratification, or filament, is assumed to be initially isotropic and at rest. It is shown that the center of mass energy can be related to the center of mass position in a form analogous to that of a solid object in a gravity field g by introducing an effective gravity field g{sub eff}, which is less than g due to energy that goes into the background and into non-center of mass motion of the filament. During the early stages of the evolution, g{sub eff} is constant in time and can be determined from the solution of a 1D differential equation that depends on the initial, radially varying density profile of the filament. For small amplitude filaments such that ρ{sub 0} ≪ 1, where ρ{sub 0} is the relative amplitude of the filament to the background, the early stage g{sub eff} scales linearly with ρ{sub 0}, but as ρ{sub 0}→∞, g{sub eff}→g and is thus independent of ρ{sub 0}. Fully nonlinear simulations are performed for the evolution of Gaussian filaments, and it is found that the time t{sub max}, which is defined as the time for the center of mass velocity to reach its maximum value U{sub max}, occurs very soon after the constant acceleration phase and so U{sub max}≈g{sub eff}(t=0)t{sub max}. The simulation results show that U{sub max}∼1/t{sub max}∼√(ρ{sub 0}) for ρ{sub 0} ≪ 1, in agreement with theory and results from previous authors, but that U{sub max} and t{sub max} both scale approximately with √(ρ{sub 0}) for ρ{sub 0} ≫ 1. The fact that U{sub max} and t{sub max} have the same scaling with ρ{sub 0} for large amplitude filaments is in agreement with the theory presented in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helicon waves in uniform plasmas. II. High m numbers

Helicons are whistler modes with azimuthal wave numbers. They have been studied in solids and plasmas where boundaries play a role. The present work shows that very similar modes exist in unbounded gaseous plasmas. Instead of boundaries, the antenna properties determine the topology of the wave packets. The simplest antenna is a magnetic loop which excites m = 0 or m = 1 helicons depending on whether the dipole moment is aligned parallel or perpendicular to the ambient background magnetic field B{sub 0}. While these low order helicons have been described by J. M. Urrutia and R. L. Stenzel [“Helicon modes in uniform plasmas. I. Low m modes,” Phys. Plasmas 22, 092111 (2015)], the present work focuses on high order modes up to m = 8. These are excited by antenna arrays forming magnetic multipoles. Their wave magnetic field has been measured in space and time in a large and uniform laboratory plasma free of boundary effects. The observed wave topology exhibits m pairs of unique field line spirals which may have inspired the name “helicon” to this mode. All field lines converge into these nested spirals which propagate like corkscrews along B{sub 0}. The field lines near the axis of helicons are perpendicular to B{sub 0} and circularly polarized as in parallel whistlers. Helical antennas couple to these transverse fields but not to the spiral fields of helicons. Using a circular antenna array of phased m = 0 loops, right or left rotating or non-rotating multipole antenna fields are generated. They excite m < 0 and m > 0 modes, showing that the plasma supports both modes equally well. The poor excitation of m < 0 modes is a characteristic of loops with dipole moment across B{sub 0}. The radiation efficiency of multipole antennas has been found to decrease with m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements

Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The inner 30 cm has a 20×20 cm{sup 2} opening, while the remaining length has a 30×30 cm{sup 2} opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm{sup 2} opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.

07 ISOTOPE AND RADIATION SOURCES↗

Detection of embedded radiation sources using temporal variation of gamma spectral data.

Conventional full spectrum gamma spectroscopic analysis has the objective of quantitative identification of all the isotopes present in a measurement. For low energy resolution detectors, when photopeaks alone are not sufficient for complete isotopic identification, such analysis requires template spectra for all the isotopes present in the measurement. When many isotopes are present it is difficult to make the correct identification and this process often requires many trial solutions by highly skilled spectroscopists. This report investigates the potential of a new analysis method which uses spatial/temporal information from multiple low energy resolution measurements to test the hypothesis of the presence of a target spectrum of interest in these measurements without the need to identify all the other isotopes present. This method is referred to as targeted principal component analysis (TPCA). For radiation portal monitor applications, multiple measurements of gamma spectra are taken at equally spaced time increments as a vehicle passes through the portal and the TPCA method is directly applicable to this type of measurement. In this report we describe the method and investigate its application to the problem of detection of a radioactive localized source that is embedded in a distributed source in the presence of an ambient background. Examples using simulated spectral measurements indicate that this method works very well and has the potential for automated analysis for RPM applications. This method is also expected to work well for isotopic detection in the presence of spectrally and spatially varying backgrounds as a result of vehicle-induced background suppression. Further work is needed to include effects of shielding, to understand detection limits, setting of thresholds, and to estimate false positive probability.

99 GENERAL AND MISCELLANEOUS↗

Coherent Elastic Neutrino Nucleus Scattering

Coherent Elastic Neutrino Nucleus Scattering (CENNS) has yet to be observed since its first prediction in 1974. The CENNS cross-section is precisely known in the Standard Model (SM). It is considerably larger than the other neutrino interaction channels at MeV energies. If measured at its predicted value, CENNS can be a very powerful tool for future neutrino oscillation experiments. Alternatively, any deviation from the very robust SM prediction could be a window to beyond-SM physics. The discovery of CENNS requires an intense source of low energy neutrinos, and a large-scale low energy threshold detector, both of which complement and build on existing programs at Fermilab. The Booster Neutrino Beamline (BNB) at Fermilab is a surprisingly powerful source of pion decay-at-rest ($\pi$DAR) neutrinos. The energy spectrum and flux of neutrinos in the backward direction (far-off-axis) of the BNB is excellent for a CENNS discovery measurement. At the closest practical location, the $\pi$DAR neutrino flux at BNB would be about a fifth of the neutrino flux of Spallation Neutron Source (SNS at Oak Ridge). The BNB site is preferable in almost every other aspect, however. First, the beam duty factor of BNB (2.5x10 -5 ) is about a factor of four better, which will help to reduce ambient backgrounds. Second, the potential experiment site, close to the BNB target, allows optimal placement of the detectors, with minimal sitting issues. The CENNS experiment would be completely parasitic to any running of the BNB. It would require no changes to the beamline, and place no additional requirements on the running mode or times. The $\pi$DAR neutrinos from the BNB are a by-product of running the beamline for MicroBooNE, and will be available for the foreseeable future. The CENNS detector would be a ton-scale single-phase Liquid Argon (LAr) detector, placed inside a water shield with an active cosmic ray veto. The low energy threshold and low background detector technology is already well developed thanks to work over the last decade in Dark Matter detector physics. Moreover, Fermilab is equipped with very strong technical and engineering resources in liquid argon detector development. One issue that must be addressed prior to the development of a full CENNS proposal is the question of whether the beam-related fast neutron background is low enough that it can be practically shielded.

Brice, S. J.↗

Authorized limits for disposal of PCB capacitors from Buildings 361 and 391 at Argonne National Laboratory, Argonne, Illinois.

This report contains data and analyses to support the approval of authorized release limits for the clearance from radiological control of polychlorinated biphenyl (PCB) capacitors in Buildings 361 and 391 at Argonne National Laboratory, Argonne, Illinois. These capacitors contain PCB oil that must be treated and disposed of as hazardous waste under the Toxic Substances Control Act (TSCA). However, they had been located in radiological control areas where the potential for neutron activation existed; therefore, direct release of these capacitors to a commercial facility for PCB treatment and landfill disposal is not allowable unless authorized release has been approved. Radiological characterization found no loose contamination on the exterior surface of the PCB capacitors; gamma spectroscopy analysis also showed the radioactivity levels of the capacitors were either at or slightly above ambient background levels. As such, conservative assumptions were used to expedite the analyses conducted to evaluate the potential radiation exposures of workers and the general public resulting from authorized release of the capacitors; for example, the maximum averaged radioactivity levels measured for capacitors nearest to the beam lines were assumed for the entire batch of capacitors. This approach overestimated the total activity of individual radionuclide identified in radiological characterization by a factor ranging from 1.4 to 640. On the basis of this conservative assumption, the capacitors were assumed to be shipped from Argonne to the Clean Harbors facility, located in Deer Park, Texas, for incineration and disposal. The Clean Harbors facility is a state-permitted TSCA facility for treatment and disposal of hazardous materials. At this facility, the capacitors are to be shredded and incinerated with the resulting incineration residue buried in a nearby landfill owned by the company. A variety of receptors that have the potential of receiving radiation exposures were analyzed. Based on the dose assessment results, it is indicated that, if the disposition activities are completed within a year, the maximum individual dose would be about 0.021 mrem/yr, which is about 0.02% of the primary dose limit of 100 mrem/yr set by U.S. Department of Energy (DOE) for members of the public. The maximum individual dose was associated with a conservative and unlikely scenario involving a hypothetical farmer who intruded the landfill area to set up a subsistence living above the disposal area 30 years after burial of the incineration residue. Potential collective dose for worker and the general public combined was estimated to be less than 4 x 10{sup -4} person-rem/yr, about 0.004% of the DOE authorized release objective of 10 person-rem/yr for collective exposure. In reality, the actual radiation doses incurred by workers and the general public are expected to be at least two orders of magnitude lower than the estimated values. To follow the ALARA (as low as reasonably achievable) principle of reducing potential radiation exposures associated with authorized release of the PCB capacitors, a dose constraint of 1 mrem/yr, corresponding to a small fraction of the 25 mrem/yr limit set by DOE, was initially used as a reference to derive the authorized release limits. On the basis of the dose assessment results, the following authorized release limits are proposed - 0.6 pCi/g for Mn-54, 0.6 pCi/g for Na-22, 0.1 pCi/g for Co-57, and 2.3 pCi/g for Co-60, with a corresponding maximum individual dose of 0.21 mrem/yr. This maximum dose, about 0.2% of the DOE primary dose limit of 100 mrem/yr for members of the public from all sources and exposure pathways, was then selected as the final dose constraint for releasing the PCB capacitors through the authorized process. The proposed authorized release limits would satisfy the DOE requirements for the release of non-real properties to a commercial treatment and disposal facility. In addition, due to the relatively short half-lives (< 5.27 years) of radionuclides of concern, there will be no long-term buildup of doses either in groundwater or through other exposure pathways associated with this particular release action. Contact with Clean Harbors and the State of Texas has been initiated. The radioactivity levels in the PCB capacitors meet the State of Texas radiological exemption limits and would be accepted by Clean Harbors, subject to the approval by DOE for the authorized release process. Cost benefit analysis shows that authorized release of the PCB capacitors would provide significant cost saving over the low-level radioactive waste (LLRW) disposition alternative, i.e. sending the PCB capacitors to a certified LLRW facility for treatment and disposal, and would not cause a significantly different impact in terms of human health protection. Therefore, authorized release is determined to be the preferred alternative for the disposition of Argonne PCB capacitors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A remote sensing laser fluorometer

A sensor is reported which is able to identify certain specific substances in water by means of their fluorescence spectra. In particular, the sensor detects oil, ligninsulfonates and chlorophyll. The device is able to measure the fluorescence spectra of water at ranges up to 75 m and to detect oil spills on water at altitudes up to 300 m. Blue light from a laser is used to excite the fluorescence of the target. Any light from the ambient background illumination, from the reflected laser light or from the induced fluorescence is gathered by a small telescope focused on the target. Optical filters are used to block the reflected laser light and to select the wavelengths of interest in the fluorescence spectrum of the target. The remaining light is detected with a photomultiplier tube. The amplitude of the laser induced fluorescence in the wavelength interval selected by the optical filters is displayed on a meter or strip chart recorder.

Oneill, R. A.↗

Remote measurements of ambient air pollutants with a bistatic laser system

The ambient air pollutants ozone, nitric oxide, and ethylene have been monitored in the Pasadena area with a bistatic IR laser apparatus. These pollutants were measured with a differential absorption technique, using selected wavelengths in the 9.5-, 5.2-, and 10.5-micron regions, respectively. The transmitted laser radiation was detected using both direct and heterodyne detection techniques. In the direct detection case, cube corner retroreflectors provided the return, and the heterodyne detection responded to scattered radiation from various rough surfaces, ranging from 400 m to 1.9 km in distance from the apparatus. Significant departures from ambient background concentration levels were noticed in the region near a local freeway during periods of moderate and heavy traffic.

Menzies, R. T.↗

EUV observations of the equatorial aurora

Using the Apollo-Soyuz mission's extreme ultraviolet telescope, it proved possible to observe the equatorial aurora on four different occasions. The observations were made from 220 km in quiet geomagnetic conditions. In all cases, signals were well above ambient background in the 50 to 150 A, 114 to 150 A, 170 to 600 A, and 500 to 780 A bands. The existence of a strong feature in the 50 to 150 A region may be an indication that other elements besides helium - possibly oxygen and nitrogen - contribute to the enhancement.

Paresce, F.↗

The equatorial aurora in the extreme ultraviolet

The extreme ultraviolet telescope on the Apollo-Soyuz mission observed the equatorial aurora from an altitude of 220 km on four separate occasions in July 1975, in quiet geomagnetic conditions (Ap = 6). In all cases signals well above ambient background in the 50-150, 114-150, 170-600, and 500-780 A bands were recorded as the spacecraft moved across the equator and the instrument viewed the atmosphere below it. The observed emissions are confined to a band roughly 10 to 20 deg in width with the peak emission occurring in the range -15 to +2 deg magnetic latitude. No enhancement on the 1350-1550 A channel was noted. The observed signals are interpreted as recombination radiation of energetic helium and, possibly, oxygen ions originating in the terrestrial ring current.

Paresce, F.↗

Prediction of corridor effect from the launching of the satellite power system

A diagnostic model is developed to define the parameters which control the corridor effect of contaminants deposited in a narrow latitudinal band of the earth's atmosphere by numerous launches of the STS and heavy lift launch vehicles for construction of satellite solar power systems. Identified factors included the pollution injection rate, the ambient background levels of the pollutant species, and the transport properties related to the dilution rate of the chemicals. If the chemical life of the pollutant was shorter or the same length of time as the transport time, alterations in the chemical production and loss rates were found to be parameters necessarily added to the model. A comparison with NASA Ames Research Center two-dimensional model results indicate that the corridor effect was possile with operations above 60 km in the case of H2O, H2, and NO production.

Borucki, W. J.↗

A low noise infrared spot scanner for testing detector arrays

A low noise spot scanner has been built for use in testing the performance of infrared detector arrays for NASA's IR detector technology development program and the University of California's MICRO program. The scanner provides a convenient low noise detector test environment and a wide range of test conditions including versatile temperature control of the detector, ambient background, and blackbody source temperature and control of spot size, color, and brightness.

Puetter, R. C.↗

Effects of signal analysis parameters and noise removal on measured aircraft spectra

Special techniques must be applied when analyzing acoustic noise data from nonstationary sources such as aircraft flyover measurements. Since the Fourier transform is time dependent, the noise signal is divided into short time segments by introducing a window function so that the spectral characteristics remain reasonably stationary. Reducing the window width reduces the frequency resolution while increasing the window duration can lead to spectral smearing. A trade-off must be made between time resolution and frequency resolution. The effects of varying the window duration on narrow-band acoustic spectra and thus the frequency bin width are addressed in this study. The influence of window functions (rectangular, Hamming, etc.) are also investigated. Both a tonal noise source, XV-15 aircraft in the airplane mode, and a broadband noise source, a F-18 aircraft, are considered. When dealing with flight test data, not only is the signal nonstationary, often it is contaminated by both ambient background noise and internal noise generated by the data acquisition system and power generators. Since generator noise is highly tonal, this can be particularly troublesome when computing tone-corrected perceived noise level (PNLT). A scheme is presented in this paper to eliminate unwanted background and internal noise.

Kelly, Jeffrey J.↗

The 3-D effects in the long-term solar wind speed rise observed by Voyager 2 in early 1994

In early 1994, Voyager 2 at 42-43 AU near heliolatitude 10 deg S observed over a period of approximately 100 days a remarkable sequence of quasi-recurrent stream fronts, wherein the background (ambient) speed rose steadily from approximately 450 to approximately 550 km/s while the mean period of the streams decreased from the usual 25 days down to approximately 20 days. A qualitative explanation for this effect can be derived from IMP observations, which show that the amplitude of the stream structure at 1 AU increased monotonically in late 1993, concurrent with major secular evolution in the corona. The reduction in period, then, amounts to a doppler shift due to the progressive overtaking of successively faster streams in the sequence. Attempts to model this process quantitatively with 1-D dynamic simulations falter on three accounts: (1) the reduction in period is overestimated, (2) the simulation predicts many more fronts surviving to 43 AU than are observed by Voyager; (3) the density variations are much too large. It is argued that inclusion of the 3-D geometry in the simulation would resolve most all these shortcomings. Using a series of calculations executed with 1-D, 2-D, and 3-D MHD models of hypothetical tilted-dipole flows, we show that: (1) the radial propagation velocities of 3-D fronts are less than those of 1-D or 2-D fronts, owing to the tilt of (and increased shearing across) the interaction surfaces hence the overtaking rate of successive streams is reduced; (2) in a tilted-dipole geometry, the reverse fronts should largely disappear from the equatorial plane by 43 AU, effectively halving the number of fronts to be observed (see companion paper on predominance of forward fronts at Voyager); and (3) the density enhancements would be much smaller than predicted by a 1-D model.

Pizzo, V. J.↗

Assessing Terra Disposal Orbit Candidates from an Orbital Debris Perspective

The NASA Terra satellite is reaching the end of its mission life. Because the satellite resides in the 705 km Earth Science Constellation, disposal strategies need to be considered to remove it from this densely populated operational orbit. Of critical importance was the need to examine the future potential risk to other satellite residents of the 705 km constellation due to an unexpected breakup event of the Terra satellite post-disposal. This study quantifies the comparative risk of debris impacts associated with the two leading candidate disposal orbits (701 km vs. 686 km) and characterizes the suitability of each orbit for the purpose of long-term spacecraft disposal. The increase in collision risk to any member of the 705 km Earth Science Constellation is very modest. The long-term, average, total risk (including the ambient background risk) due to a Terra breakup at a disposal of -19 km (i.e., 686 km) relative to the 705 km constellation is 9.7 × 10(exp -6) impacts/day versus 1.0 × 10(exp -5) impacts/day for a disposal of only -4 km (i.e., 701 km). For perspective, note that the nominal space background risk to the 705 km constellation is 9.2 × 10(exp -6) impacts/day which implies a very modest increase in risk (approximately 3% difference between the two cases) due to a Terra breakup in either disposal orbit.

Abraham, Andrew J.↗

A Psychoacoustic Test on the Effect of Masking on Annoyance to Urban Air Mobility Vehicle Noise

Urban Air Mobility (UAM) vehicles have a large range of designs and configurations that lead to new noise characteristics and potentially different perceptual responses when compared to traditional aircraft. In addition, UAM vehicles are expected to operate around and within densely populated regions where the presence of ambient background noise is often present. Strategically, this can be leveraged to inform vehicle design and operations to partially or completely mask UAM noise, allowing for mitigation of negative responses and an increased number of allowed operations. A psychoacoustic test was conducted to investigate how masking effects can influence the annoyance response to a low frequency harmonic tone complex (80-320 Hz). To do this, five test subjects compared their annoyance response to the low frequency tonal noise with a higher frequency broadband noise (10dB down bandwidth between 300-2000 Hz), with and without a masking noise present. Detection thresholds were also measured for both sounds to help fit a model to the data. Although the effect of masking on annoyance is complex, results indicate that for some individuals, masking leads to a lower annoyance than the sound level alone would predict.

Matthew Boucher↗

Automatic Analyte-Ion Recognition and Background Removal for Ambient Mass-Spectrometric Data Based on Cross-Correlation

Ambient mass spectrometry is a powerful approach for rapid, high-throughput, and direct sample analysis. Due to the open-air desorption and ionization processes, random fluctuations of ambient conditions can lead to large variances in mass-spectral signals over time. The mass-spectral data also can be further complicated due to multiple analytes present in the sample, background-ion signals stemming from the desorption/ionization source itself, and other laboratory-specific conditions (e.g., ambient laboratory air, nearby hardware). Thus, background removal and analyte-ion recognition can be quite difficult, particularly in non-targeted analyses. Here, we demonstrate the use of a cross-correlation-based approach to exploit chemical information encoded in the time domain to group/categorize mass-spectral peaks from a single analysis dataset. Ions that originate from ambient (or other) background species were readily flagged and removed from spectra; the result was a decrease in mass-spectral complexity by over 70% due to the removal of these background ions. Meanwhile, analyte ions were differentiated and categorized based on their time-domain profiles. With sufficient mass resolving-power and mass-spectral acquisition rate, isolated mass spectra containing ions from the same species in a sample could be extracted, leading to a reduction in mass-spectral complexity by more than 98% in some cases. The cross-correlation approach was tested with different ionization sources as well as reproducible and irreproducible sample introduction. Software built in-house enabled fully automated data processing, which can be performed within a few seconds. Ultimately, this approach provides an additional dimension of analyte separation in ambient mass-spectrometric analyses with information that is already recorded throughout the analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗