At least 37 records · Page 2

Capacity decline of ambient temperature secondary lithium battery

The use of ambient temperature secondary lithium cells is limited primarily because of the poor cycle life performance. Much of the cell capacity is irreversibly lost upon cycling. Studies have been undertaken to understand the problem of capacity decline. Experimental Li-TiS2 cells were fabricated and tested for their cycle life performance. Cells were disassembled at different stages of cycle life, and cell active components were analyzed by various analytical techniques. The results of this study indicate that all the cell's active components/materials are undergoing degradation. Details of the experiments carried out and the results obtained are described.

Shen, D. H.↗

Performance characteristics of ambient temperature secondary lithium cells

State of art ambient temperature secondary lithium cells were evaluated to determine their performance capability and limitations and to assess the present status of the technology of these cells. Li-MoS2, Li-NbSe3 and Li-TiS2 cells were evaluated for their charge/discharge characteristics, rate capability, and cycle life performance. The cells evaluated have a cycle life of 100-250 cycles at moderate discharge rates (C/5). The specific energy of these cells is between 50 and 100 Wh/Kg, depending upon the system. This paper describes the details of the cell designs, the test procedures, and the results of the evaluation studies.

Deligiannis, F.↗

Development of ambient temperature secondary lithium cells

JPL is developing ambient temperature secondary lithium cells for future spacecraft applications. Prior studies on experimental laboratory type Li-TiS2 cells yielded promising results in terms of cycle life and rate capability. To further assess the performance of this cell, 5 Ah engineering model cells were developed. Initially baseline cells were designed and fabricated. Each cell had 15 cathodes and 16 anodes and the ratio of anode to cathode capacity is 6:1. A solution of 1.5 molar LiAsF6 in 2Me-THF was used as the electrolyte. Cells were evaluated for their cycle life at C/1 and C/5 discharge rates and 100 percent depth of discharge. The cells were cycled between voltage limits 1.7 and 2.8 volts. The rate of charge in all cases is C/10. The results obtained indicate that cells can operate at C/10 to C/2 discharge rates and have an initial energy density of 70 Wh/kg. Cells delivered more than 100 cycles at C/2 discharge rate. The details of cell design, the test program, and the results obtained are described.

Subbarao, S.↗

Understanding Electric Vehicle Range and Charging Needs: Interactions Between Ambient Temperature, Commute Patterns, and State-of-Charge Usage

Electric vehicle (EV) performance can vary substantially under real-world operating conditions, particularly due to ambient temperature effects on energy consumption, battery behavior, and thermal management requirements. This study quantifies how weather conditions, daily driving patterns, and State-of-Charge (SOC) usage strategies jointly influence EV driving range, charging frequency, and overall energy efficiency. A detailed and experimentally validated Autonomie vehicle model is developed, integrating a powertrain, a mono-zonal cabin model, and a battery electro-thermal model. Three battery sizes (200-, 300-, and 400-mile homologated ranges) are assessed across five commute profiles (20–200 miles) and six ambient temperatures (−18 °C to 50 °C), including scenarios with and without preconditioning. Results show that extreme temperatures could significantly decrease the maximum achievable range by up to 55% in cold conditions (−18 °C) and 40% in hot conditions (50 °C), relative to moderate conditions. Larger battery packs retain a greater fraction of their nominal range under thermal stress, while smaller packs experience sharper relative penalties due to the higher contribution of thermal loads to total energy demand. The analysis further demonstrates that limiting operation to partial SOC windows (e.g., 80–20%), a common real-world practice, significantly reduces achievable range and increases charging frequency, particularly in cold weather. Thermal preconditioning while plugged in is shown to mitigate these effects for short trips, reducing energy consumption by up to 31% in hot conditions and 7% in cold conditions. The findings demonstrate how climate, SOC usage behavior, and thermal management jointly shape the practical driving capability of EVs, highlighting the importance of efficient thermal management and realistic user charging strategies for ensuring reliable EV operation across diverse climatic scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Ambient temperature recorder

A temperature data recorder, designated the Ambient Temperature Recorder (ATR-4), was developed at NASA Ames Research Center to meet particular requirements for space life sciences experiments. The small, self-contained, four-channel, battery-powered device records 32 kilobytes of temperature data over a range of -40 to +60 C at four sampling intervals ranging from 1.875 to 15 minutes. Data is stored in its internal electronic memory for later readout by a personal computer.

Russell, Larry D.↗

Variation of forearm, hand, and finger blood flow indices with ambient temperature

Forearm, hand, and finger blood flow (impedance) changes are measured by impedance rheography on seven healthy male subjects aged 20-35 yr during exposure to ambient temperatures ranging from 10 to 46 C. All observations are made in an environmental chamber at a dew point temperature of 13 + or - 0.25 C. It is shown that impedance rheography is suitable for quantifying peripheral circulatory responses to thermal stress. The measured blood flow indices are found to be consistent with previously reported values for the forearm, hand, and fingers obtained using air or water displacement plethysmography. In particular, the more distal body segments exhibit relatively larger vasomotor responses to changes in ambient temperature than do the more proximal body segments.

Montgomery, L. D.↗

Ambient temperature effects on broadband UV-B measurements using fluorescent phosphor (MgWO4)-based detectors

Results of field tests on a group of broadband UV-B pyranometers are presented. A brief description of the instrument is given. The effects of ambient temperature on thermally unregulated fluorescent phosphor (Robertson type) meters are presented and compared with the performance of thermally stabilized instruments. Means for correcting data from thermally unregulated instruments, where the prevailing ambient temperatures are known, are outlined.

Dichter, Bronislaw K.↗

Test Standard Developed for Determining the Slow Crack Growth of Advanced Ceramics at Ambient Temperature

The service life of structural ceramic components is often limited by the process of slow crack growth. Therefore, it is important to develop an appropriate testing methodology for accurately determining the slow crack growth design parameters necessary for component life prediction. In addition, an appropriate test methodology can be used to determine the influences of component processing variables and composition on the slow crack growth and strength behavior of newly developed materials, thus allowing the component process to be tailored and optimized to specific needs. At the NASA Lewis Research Center, work to develop a standard test method to determine the slow crack growth parameters of advanced ceramics was initiated by the authors in early 1994 in the C 28 (Advanced Ceramics) committee of the American Society for Testing and Materials (ASTM). After about 2 years of required balloting, the draft written by the authors was approved and established as a new ASTM test standard: ASTM C 1368-97, Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Ambient Temperature. Briefly, the test method uses constant stress-rate testing to determine strengths as a function of stress rate at ambient temperature. Strengths are measured in a routine manner at four or more stress rates by applying constant displacement or loading rates. The slow crack growth parameters required for design are then estimated from a relationship between strength and stress rate. This new standard will be published in the Annual Book of ASTM Standards, Vol. 15.01, in 1998. Currently, a companion draft ASTM standard for determination of the slow crack growth parameters of advanced ceramics at elevated temperatures is being prepared by the authors and will be presented to the committee by the middle of 1998. Consequently, Lewis will maintain an active leadership role in advanced ceramics standardization within ASTM. In addition, the authors have been and are involved with several international standardization organizations including the Versailles Project on Advanced Materials and Standards (VAMAS), the International Energy Agency (IEA), and the International Organization for Standardization (ISO). The associated standardization activities involve fracture toughness, strength, elastic modulus, and the machining of advanced ceramics.

Choi, Sung R.↗

Overcharge and overdischarge protection of ambient temperature secondary lithium cells

A cathode additive is provided for protecting an ambient temperature secondary lithium cell from overcharging or overdischarging. The cathode additive is chosen to create an upper voltage plateau which is slightly higher than a characteristic charge cutoff voltage of the cathode of the cell. The cathode additive additionally creates a lower voltage plateau which is slightly lower than the characteristic discharge cutoff voltage of the cell. Preferably, the cathode additive is a transition metal oxide or a sulfide and may, for example, include a mixture of Li2Mn2O4 and Li(0.1)MoO2.

Huang, Chen-Kuo↗

Higher-Performance Ambient-Temperature Heat Pipe

Improved version of heat pipe described in "High-Performance Ambient-Temperature Heat Pipe" (MFS-26062). Lining of sintered aluminum powder added to liquid channel. Results in improved thermal performance.

Ernst, Donald M.↗

The effect of ambient temperature and humidity on the carbon monoxide emissions of an idling gas turbine

Changes in ambient temperature and humidity affect the exhaust emissions of a gas turbine engine. The results of a test program employing a JT8D combustor are presented which quantize the effect of these changes on carbon monoxide emissions at simulated idle operating conditions. Analytical results generated by a kinetic model of the combustion process and reflecting changing ambient conditions are given. It is shown that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine engine.

Kauffman, C. W.↗

Mid-infrared photodetection with 2D metal halide perovskites at ambient temperature

The detection of mid-infrared (MIR) light is technologically important for applications such as night vision, imaging, sensing, and thermal metrology. Traditional MIR photodetectors either require cryogenic cooling or have sophisticated device structures involving complex nanofabrication. Here, we conceive spectrally tunable MIR detection by using two-dimensional metal halide perovskites (2D-MHPs) as the critical building block. Leveraging the ultralow cross-plane thermal conductivity and strong temperature-dependent excitonic resonances of 2D-MHPs, we demonstrate ambient-temperature, all-optical detection of MIR light with sensitivity down to 1 nanowatt per square micrometer, using plastic substrates. Through the adoption of membrane-based structures and a photonic enhancement strategy unique to our all-optical detection modality, we further improved the sensitivity to sub–10 picowatt-per-square-micrometer levels. The detection covers the mid-wave infrared regime from 2 to 4.5 micrometers and extends to the long-wave infrared wavelength at 10.6 micrometers, with wavelength-independent sensitivity response. Our work opens a pathway to alternative types of solution-processable, long-wavelength thermal detectors for molecular sensing, environmental monitoring, and thermal imaging.

Li, Yanyan [Yale University, New Haven, CT (United↗

Ambient-Temperature Sputtering Of Composite Oxide Films

Technique for deposition of homogeneous films of multicomponent oxides on substrates at ambient temperature based on sequential sputter deposition of individual metal components, as alternating ultra-thin layers, from multiple targets. Substrates rotated over sputtering targets of lead, zirconium, and titanium. Dc-magnetron sputtering of constituent metals in reactive ambient of argon and oxygen leads to formation of the respective metal oxides intermixed on extremely fine scale in desired composition. Compatible with low-temperature microelectronic processing.

Thakoor, Sarita↗