Field ionization characteristics of an ion source array for neutron generators

A new deuterium ion source is being developed to improve the performance of existing compact neutron generators. The ion source is a microfabricated array of metal tips with an integrated gate (i.e., grid) and produces deuterium ions by field ionizing (or field desorbing) a supply of deuterium gas. Deuterium field ion currents from arrays at source temperatures of 77 K and 293 K are studied. Ion currents from single etched-wire tips operating under the same conditions are used to help understand array results. I-F characteristics of the arrays were found to follow trends similar to those of the better understood single etched-wire tip results; however, the fields achieved by the arrays are limited by electrical breakdown of the structure. Neutron production by field ionization at 293 K was demonstrated for the first time from microfabricated array structures with integrated gates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigations of ablation stream interaction dynamics in tungsten wire arrays: Interpenetration, magnetic field advection, and ion deflection

Experiments have been carried out to investigate the collisional dynamics of ablation streams produced by cylindrical wire array z-pinches. A combination of laser interferometric imaging, Thomson scattering, and Faraday rotation imaging has been used to make a range of measurements of the temporal evolution of various plasma and flow parameters. This paper presents a summary of previously published data, drawing together a range of different measurements in order to give an overview of the key results. The paper focuses mainly on the results of experiments with tungsten wire arrays. Early interferometric imaging measurements are reviewed, then more recent Thomson scattering measurements are discussed; these measurements provided the first direct evidence of ablation stream interpenetration in a wire array experiment. Combining the data from these experiments gives a view of the temporal evolution of the tungsten stream collisional dynamics. In the final part of the paper, we present new experimental measurements made using an imaging Faraday rotation diagnostic. These experiments investigated the structure of magnetic fields near the array axis directly; the presence of a magnetic field has previously been inferred based on Thomson scattering measurements of ion deflection near the array axis. Although the Thomson and Faraday measurements are not in full quantitative agreement, the Faraday data do qualitatively supports the conjecture that the observed deflections are induced by a static toroidal magnetic field, which has been advected to the array axis by the ablation streams. It is likely that detailed modeling will be needed in order to fully understand the dynamics observed in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial Calibrations and Wind Tunnel Test Results for an In-Flow Reference Array Using New In-Flow Acoustic Sources in Four Array Mount Configurations

This paper describes efforts to develop a small in-flow phased microphone array as a reference acoustic sensor and quantify its level-measurement accuracy with new in-flow calibration sources. The devices can be applied to a wide variety of in- and out-of-flow measurement applications and test facilities. Recent tests of the array and two calibration sources in the NASA Anechoic Chamber and Army 7- by 10-foot Wind Tunnel at NASA Ames Research Center demonstrated that the array was functional over a frequency range of 2 to 100 kilohertz for emission angles of 92 degrees, 108 degrees, and 120 degrees, and Mach numbers of 0, 0.15, and 0.25. The array and calibration sources were then used to assess the relative effects of array installation on background noise and level measurement accuracy by locating the array in the flow (strut- and wall-mounted) as well as outside the flow behind a porous wall screen and a free shear layer. The wind tunnel array measurements were compared with anechoic chamber measurements using discrete microphones at the same source distance and emission angles. At 92 degrees, the noise floor and attenuation spectra were comparable (within 5 decibels) for each installation from 2 to 30 kilohertz. At higher angles, the array installation behind the Kevlar screen had the lowest noise floor at M = 0.15 and 0.25. The array installation 10 inches (maximum available distance) behind a free shear layer had higher background noise that is typically reduced to a lower level by moving the array back further from the flow. For emission angles greater than 92 degrees, both the Kevlar and free shear layer installations exhibited stronger attenuations in measured level, beginning at lower frequencies than either the wall- or strut-mount configurations. Additional array and calibration source units of the same design are being tested at NASA’s Glenn Research Center and Langley Research Center in their aeroacoustic research facilities in an effort to improve measurement accuracy and repeatability.

Aeroacoustic Wind Tunnel Research↗

Study of the precursor and non-precursor implosion regimes in wire array Z-pinches

Star-like and closely spaced nested wire array configurations were investigated in precursor and non-precursor implosions. Closely spaced nested cylindrical arrays have inner and outer arrays with equal wire numbers, and inner and outer wires aligned to each other. The gap between the outer and inner wires is not more than 1 mm. Calculation of magnetic fields shows that the small gap results in a reversed, outward j Multiplication-Sign B force on the inner wires. Closely spaced arrays of 6-16 wires with outer diameter of 16 mm and with gaps of {Delta}R = 0.25-1 mm were tested. 6-8-wire arrays with a gap of {Delta}R = 0.4-1 mm imploded without precursor, but precursor was present in loads with 12-16 wires and {Delta}R = 0.25-1 mm. Implosion dynamics of closely spaced arrays was similar to that of star-like arrays. Implosion time was found to decrease with decreased wire numbers. Star array configurations were designed with a numerical scheme to implode with or without precursor. The lack of precursor resulted in a marginal improvement in total x-ray yield and power, and up to 20% increase in Al K-shell yield. The Al K-shell radiated energy was found to increase with decreasing the number of arrays in closely spaced and star-like wire arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Antenna-coupled TES bolometers used in BICEP2, Keck Array, and Spider

We have developed antenna-coupled transition-edge sensor bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including Bicep2, Keck Array, and the balloon borne Spider. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%–30% bandwidth at 95, 150, or 230 GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ∼0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET ∼ 300 μK{sub CMB}√s. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ∼9 μK{sub CMB}√s, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the Spider instrument, and development of this technology is ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive methods of generating complex light arrays

Structured light arrays of various shapes have been a cornerstone in optical science, driven by the complexities of precise and adaptable generation. This study introduces an approach using a spatial light modulator (SLM) as a generator for these arrays. By projecting a holographic mask onto the SLM, it functions simultaneously as an optical convolution device, focusing mechanism, and structured light beam mask. Our approach offers unmatched versatility, allowing for the experimental fabrication of traditional beam arrays like azimuthal Laguerre–Gaussian (LG), Bessel–Gaussian (BG), and Hermite–Gauss (HG) in the far-field. Notably, it has enabled a method of generating Ince–Gauss (IG) and LG radial mode beam arrays using a convolution solution. Our system provides exceptional control over array periodicity and intensity distribution, bypassing the Talbot self-imaging phenomenon seen in traditional setups. We provide an in-depth theoretical discussion, supported by empirical evidence, of our far-field results. This method has vast potential for applications in optical communication, data processing, and multi-particle manipulation. It paves the way for rapid generation of structured light with high spatial frequencies and complex shapes, promising transformative advances in these domains.

Optics↗

Silicon Emitter Needle and Array Design for Indium Electrospray Arrays for Spacecraft Propulsion

A design for silicon microfabricated emitter arrays was developed for electrospray thrusters for indium propellant in compact architectures with scalable thrust, low mass and volume, high specific impulse and high efficiency operation. The design elements include tip height, height uniformity across the array, tip radii, axial groove depth, tip angle, emitter shank sidewall angle and number of emitters. They were derived from commercial liquid metal ion source designs and modeling, fabrication and test results. The most critical results of the emitter array design analysis suggest that microfabricated silicon emitter array emitters should have a height greater than 280 microns with a height uniformity of +/-10 microns, a tip half angle of 49° for uniform turn-on voltages and current across the array, low beam divergence and high mass utilization efficiency. Elements of the design were fabricated and demonstrated in single emitter and in 400 element emitter arrays to validate the design, fabrication and performance capability. The design height and uniformity of arrays was demonstrated for 85% of the emitters in a prototype array. Required tip and sidewall angles and groove depths have been microfabricated. Single microfabricated silicon emitters demonstrated better performance in current and voltage characteristics than commercially available liquid metal ion sources. Microfabricated emitters and arrays demonstrated the required current and stability performance to enable the MEP thruster development for indium propellant.

Marrese-Reading, Colleen M.↗

Mass accretion and nested array dynamics from Ni-Clad Ti-Al wire array Z pinches.

Analysis of 50 mm diameter wire arrays at the Z Accelerator has shown experimentally the accretion of mass in a stagnating z pinch and provided insight into details of the radiating plasma species and plasma conditions. This analysis focused on nested wire arrays with a 2:1 (outeninner) mass, radius, and wire number ratio where Al wires were fielded on the outer array and Ni-clad Ti wires were fielded on the inner array.In this presentation, we will present analysis of data from other mixed Al/Ni-clad Ti configurations to further evaluate nested wire array dynamics and mass accretion. These additional configurations include the opposite configuration to that described above (Ni-clad Ti wires on the outer array, with Al wires on the inner array) as well as higher wire number Al configurations fielded to vary the interaction of the two arrays. These same variations were also assessed for a smaller diameter nested array configuration (40 mm). Variations in the emitted radiation and plasma conditions will be presented, along with a discussion of what the results indicate about the nested array dynamics. Additional evidence for mass accretion will also be presented.

43 PARTICLE ACCELERATORS↗

Evaluation of nested wire array dynamics with mixed wire array Z pinches.

A series of experiments at the Z Accelerator was performed with 40mm and 50mm diameter nested wire arrays to investigate the interaction of the arrays and assess radiative characteristics. These arrays were fielded with one array as Al:Mg (either the inner or the outer array) and the other array as Ni-clad Ti (the outer or inner array, with respect to location of the Al:Mg). In all the arrays, the mass and radius ratio of the outer:inner was 2:1. The wire number ratio was also 2:1 in some cases, but the Al:Mg wire number was increased in some loads. This presentation will focus on analysis of the emitted radiation (in multiple photon energy bins) and measured plasma conditions (as inferred from x-ray spectra). A discussion on what these results indicate about nested array dynamics will also be presented.

43 PARTICLE ACCELERATORS↗

Focal plane array with modular pixel array components for scalability

A modular, scalable focal plane array is provided as an array of integrated circuit dice, wherein each die includes a given amount of modular pixel array circuitry. The array of dice effectively multiplies the amount of modular pixel array circuitry to produce a larger pixel array without increasing die size. Desired pixel pitch across the enlarged pixel array is preserved by forming die stacks with each pixel array circuitry die stacked on a separate die that contains the corresponding signal processing circuitry. Techniques for die stack interconnections and die stack placement are implemented to ensure that the desired pixel pitch is preserved across the enlarged pixel array.

42 ENGINEERING↗

Advanced Laboratory and Field Arrays: Technical Report for Performance Enhancement for Marine Energy Converter (MEC) Arrays (Task 5)

Task 5 consisted of two parts, wave energy converter (WEC) arrays and current energy converter (CEC) arrays. The two parts of the project were executed independently, and this report covers only the work on WECs. In this part of the task, the team characterized the behavior of and developed control schemes for wave energy converter (WEC) arrays that improved performance (i.e., maximized aggregate power generation and reduced the levelized cost of energy) over baseline, non-coordinated control approaches. Specifically, for WEC arrays: the team developed optimal layouts of arrays that considered the effect of WEC placement within an array on coordinated array control with real-time estimation schemes. The numerical codes developed through this task were made available to users for array design. These tools utilized existing commercial software as well as software developed within the project team.

13 HYDRO ENERGY↗

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras

We developed a robust and low-cost array of virtual Frisch-grid CdZnTe (CZT) detectors coupled to a front-end readout ASIC for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6x6x15 mm 3 detectors grouped into 3x3 sub-arrays of 2x2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single- or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays’ performance and reduction of their cost are made possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects.

36 MATERIALS SCIENCE↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Local imaging of diamagnetism in proximity-coupled niobium nanoisland arrays on gold thin films.

In this work, we study the effect of engineered disorder on the local magnetic response of proximity-coupled superconducting island arrays by comparing scanning superconducting quantum interference device (SQUID) susceptibility measurements to a model in which we treat the system as a network of one-dimensional (1D) superconductor-normal-metal-superconductor Josephson junctions, each with a Josephson coupling energy E-J determined by the junction length or distance between islands. We find that the disordered arrays exhibit a spatially inhomogeneous diamagnetic response which, for low local applied magnetic fields, is well described by this junction network model, and we discuss these results as they relate to inhomogeneous 2D superconductors. Our model of the static magnetic response of the arrays does not fully capture the onset of nonlinearity and dissipation with increasing applied field, as these effects are associated with vortex motion due to the dynamic nature of the scanning SQUID susceptometry measurement. This work demonstrates a model 2D superconducting system with engineered disorder, and it highlights the impact of dissipation on the local magnetic properties of 2D superconductors and Josephson junction arrays.

Bishop-Van Horn, Logan↗

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗