Search NASA⌕ Search

SEARCH · Search NASA

Results for “astronomical detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Integrated detector array preprocessing for infrared astronomical applications

On-board preprocessing of astronomical data from integrated infrared detector arrays and discrete detectors will allow increases in sensitivity and reductions in costs for observations from cryogenic space telescopes. A variety of preprocessing functions for this application, which could be implemented either through analog on-chip devices or through external microprocessors, is identified. Software simulations and laboratory evaluations are underway to determine the effectiveness of these preprocessing schemes.

Mccreight, C. R.↗

Precision Projector Laboratory: Detector Characterization with an Astronomical Emulation Testbed

As astronomical observations benefit from improved sensitivity, the effectiveness of scientific programs is becoming limited by systematics that often originate in poorly understood image sensor behavior. Traditional, bottom-up detector characterization methods provide one way to model underlying detector physics, and generate ever more faithful numerical simulations, but this approach is vulnerable to preconceptions and over-simplification. The alternative top-down approach is laboratory emulation, which enables observation, calibration, and analysis scenarios to be tested without relying on a complete understanding of the underlying physics. This complements detector characterization and simulation efforts by testing their validity. We describe a laboratory facility and experimental testbed that supports the emulation of a wide range of mission concepts such as gravitational weak lensing measurements by WFIRST and high precision spectrophotometry of transiting exoplanets by JWST. An Offner relay projects readily customizable "scenes" (e.g. stars, galaxies, spectra) with very low optical aberration over the full area of a typical optical or near infrared image sensor. f/8 and slower focal ratios may be selected, spanning those of most proposed space missions and approximating the point spread function (PSF) size of seeing limited ground based surveys. Diffraction limited PSFs are projected over a wide field of view and wavelength range to deliver highly predictable image patterns down to sub-pixel scales with stable intensity and fine motion control. The testbed enables realistic validation of detector performance on science-like images, which aids mission design and survey strategy, as well as targeted investigations of various detector effects.

Seshadri, Suresh↗

JWST Noise Floor. I. Random Error Sources in JWST NIRCam Time Series

James Webb Space Telescope (JWST) transmission and emission spectra will provide invaluable glimpses of transiting exoplanet atmospheres, including possible biosignatures. This promising science from JWST, however, will require exquisite precision and understanding of systematic errors that can impact the time series of planets crossing in front of and behind their host stars. Here, we provide estimates of the random noise sources affecting JWST Near-Infrared Camera (NIRCam) time-series data on the integration-to-integration level. We find that 1/ f noise can limit the precision of grism time series for two groups (230–1000 ppm depending on the extraction method and extraction parameters) but will average down like the square root of N frames/reads. The current NIRCam grism time-series mode is especially affected by 1/ f noise because its GRISMR dispersion direction is parallel to the detector fast-read direction, but could be alleviated in the GRISMC direction. Care should be taken to include as many frames as possible per visit to reduce this 1/ f noise source: thus, we recommend the smallest detector subarray sizes one can tolerate, four output channels, and readout modes that minimize the number of skipped frames (RAPID or BRIGHT2). We also describe a covariance-weighting scheme that can significantly lower the contributions from 1/ f noise as compared to sum extraction. We evaluate the noise introduced by preamplifier offsets, random telegraph noise, and high dark current resistor capacitor (RC) pixels and find that these are correctable below 10 ppm once background subtraction and pixel masking are performed. We explore systematic error sources in a companion paper.

Exoplanet atmospheres↗

Development of a segmented n-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented.

Gehrels, N.↗

The development of a segmented N-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented. Previously announced in STAR as N84-13039

Gehrels, N.↗

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

Assessment study of infrared detector arrays for low-background astronomical research

The current state-of-the-art of infrared detector arrays employing charge coupled devices (CCD) or charge injection devices (CID) readout are assessed. The applicability, limitations and potentials of such arrays under the low-background astronomical observing conditions of interest for SIRFT (Shuttle Infrared Telescope Facility) are determined. The following are reviewed: (1) monolithic extrinsic arrays; (2) monolithic intrinsic arrays; (3) charge injection devices; and (4) hybrid arrays.

Ando, K. J.↗

Infrared astronomical imaging using a microcomputer data system

A small, portable data-acquisition and display system with a unique coprocessor was designed and built to collect data from infrared array detectors for astronomical and laboratory use. The system consists of a microcomputer board, two 12-bit analog-to-digital data-acquisition boards, a color-graphics driver board, and two coprocessor boards. The coprocessors are arithmetic logic units designed to achieve the high computation rates necessary for real-time infrared background cancellation. The system can collect data from infrared detectors of 1 to 256 pixel elements with a computation rate of 768 kHz. The software for the system was designed to collect data in the system's background, while performing other tasks in the system's foreground. The data for the detector arrays is stored in block fashion to facilitate variable image size.

Stafford, P. S.↗

Photographic film as a detector for solar X-ray/XUV astronomical applications

The characteristics of several films as detectors for solar soft X-ray (3-100 A) and XUV (100-600 A) radiation are discussed. The properties of soft-X-ray-sensitive films like the SO-212 make them useful for the glancing-incidence X-ray telescopes. Used for the MSFC X-Ray Telescope during the Skylab mission (at the wavelengths of 8.34 and 15.4 A), the SO-212 film functioned as a photon detector, achieving spatial resolution of 2.2 arc sec. Other high-resolution soft-X-ray-sensitive films include SO-242 and 101-07. For XUV detection, the SC-5, SC-7, 104-07, and 101-07 films are recommended.

Hoover, Richard B.↗

Equalizing the Pixel Response of the Imaging Photoelectric Polarimeter Onboard the IXPE Mission

The Gas Pixel Detector is a gas detector, sensitive to the polarization of X-rays, currently flying onboard the Imaging X-ray Polarimetry Explorer (IXPE)—the first observatory dedicated to X-ray polarimetry. It detects X-rays and their polarization by imaging the ionization tracks generated by photoelectrons absorbed in the sensitive volume, and then reconstructing the initial direction of the photoelectrons. The primary ionization charge is multiplied and ultimately collected on a finely pixellated ASIC specifically developed for X-ray polarimetry. The signal of individual pixels is processed independently and gain variations can be substantial, of the order of 20%. Such variations need to be equalized to correctly reconstruct the track shape, and therefore its polarization direction. The method to do such equalization is presented here and is based on the comparison between the mean charge of a pixel with respect to the other pixels for equivalent events. The method is shown to finely equalize the response of the detectors onboard IXPE, allowing a better track reconstruction and energy resolution, and can in principle be applied to any imaging detector based on tracks.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Telescope Transmission Using a Collimated Beam Projector

With the increasingly large number of Type Ia supernova being detected by current-generation survey telescopes, and even more expected with the upcoming Rubin Observatory Legacy Survey of Space and Time, the precision of cosmological measurements will become limited by systematic uncertainties in flux calibration rather than statistical noise. One major source of systematic error in determining SNe Ia color evolution (needed for distance estimation) is uncertainty in telescope transmission, both within and between surveys. We introduce here the Collimated Beam Projector (CBP), which is meant to measure a telescope transmission with collimated light. The collimated beam more closely mimics a stellar wave front as compared to flat-field-based instruments, allowing for more precise handling of systematic errors such as those from ghosting and filter angle-of-incidence dependence. As a proof of concept, we present CBP measurements of the StarDICE prototype telescope, achieving a standard (1σ) uncertainty of 3% on average over the full wavelength range measured with a single beam illumination.

79 ASTRONOMY AND ASTROPHYSICS↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a mercuric iodide solid state spectrometer for X-ray astronomy

Mercuric iodide detectors, experimental development for astronomical use, X ray observations of the 1980 Cygnus X-1 High State, astronomical had X ray detectors in current use, detector development, balloon flight of large area (1500 sq cm) Phoswich detectors, had X ray telescope design, shielded mercuric iodide background measurement, Monte Carlo analysis, measurements with a shielded mercuric iodide detector are discussed.

Vallerga, J.↗

Icy Satellites of the Planets, and the Work of V.I. Moroz

The satellites of the giant planets are highly varied in size and density, indicating a wide range of compositions. The principal components of these satellites are ices of many different compositions (with H2O the most abundant) and varying amounts of silicate rocky material. Many different ices have been found by spectroscopic techniques both from Earth-based observatories and from planetary spacecraft. Three of the Galilean satellites of Jupiter exhibit H2O ice on their surfaces, while small amounts of CO2 are present on Ganymede and Callisto. The volcanic satellite Io has abundant SO2 ice and frost deposits. Saturn s satellites have surfaces dominated by H2O ice, but CO2 is also present on most of them, and in the cases of the low-albedo satellites Iapetus and Phoebe, there is evidence of complex hydrocarbons mixed with the surface materials. The large Uranian satellites also have H2O-dominated surfaces, but CO2 has also been discovered on two of them. Neptune s largest satellite, Triton, show spectroscopic evidence for six different ices, including N2, CH4, CO, CO2, H2O, and C2H6. The latter ice is a photochemical product from the action of sunlight on Triton's atmosphere. Pluto is similar to Triton, although CO2 has not been found. Pluto s large satellite, Charon, shows evidence for an ammonia hydrate on part of its surface. V. I. Moroz was a pioneer in the application of near-infrared detectors to astronomical sources. Using a prism spectrometer he measured the spectra of the Galilean satellites of Jupiter, and in 1966 he published the first near-infrared spectra, noting the appearance of H2O ice as a major component of Europa and Ganymede. This discovery, and the techniques of Moroz measurements help set the stage for the broad extension of the study of planetary, satellite, and asteroid surfaces through reflectance spectroscopy in the near-infrared.

Cruikshank, Dale P.↗

Self-scanned photodiode array - High performance operation in high dispersion astronomical spectrophotometry

A multichannel spectrophotometric detector system has been developed using a 1024 element self-scanned silicon photodiode array, which is now in routine operation with the high-dispersion coude spectrograph of the University of Texas McDonald Observatory 2.7-m telescope. Operational considerations in the use of such arrays for high precision and low light level spectrophotometry are discussed. A detailed description of the system is presented. Performance of the detector as measured in the laboratory and on astronomical program objects is described, and it is shown that these arrays are highly effective detectors for high dispersion astronomical spectroscopy.

Vogt, S. S.↗