Search NASA⌕ Search

SEARCH · Search NASA

Results for “astronomical detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of a segmented n-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented.

Gehrels, N.↗

The development of a segmented N-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented. Previously announced in STAR as N84-13039

Gehrels, N.↗

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

Assessment study of infrared detector arrays for low-background astronomical research

The current state-of-the-art of infrared detector arrays employing charge coupled devices (CCD) or charge injection devices (CID) readout are assessed. The applicability, limitations and potentials of such arrays under the low-background astronomical observing conditions of interest for SIRFT (Shuttle Infrared Telescope Facility) are determined. The following are reviewed: (1) monolithic extrinsic arrays; (2) monolithic intrinsic arrays; (3) charge injection devices; and (4) hybrid arrays.

Ando, K. J.↗

Infrared astronomical imaging using a microcomputer data system

A small, portable data-acquisition and display system with a unique coprocessor was designed and built to collect data from infrared array detectors for astronomical and laboratory use. The system consists of a microcomputer board, two 12-bit analog-to-digital data-acquisition boards, a color-graphics driver board, and two coprocessor boards. The coprocessors are arithmetic logic units designed to achieve the high computation rates necessary for real-time infrared background cancellation. The system can collect data from infrared detectors of 1 to 256 pixel elements with a computation rate of 768 kHz. The software for the system was designed to collect data in the system's background, while performing other tasks in the system's foreground. The data for the detector arrays is stored in block fashion to facilitate variable image size.

Stafford, P. S.↗

Photographic film as a detector for solar X-ray/XUV astronomical applications

The characteristics of several films as detectors for solar soft X-ray (3-100 A) and XUV (100-600 A) radiation are discussed. The properties of soft-X-ray-sensitive films like the SO-212 make them useful for the glancing-incidence X-ray telescopes. Used for the MSFC X-Ray Telescope during the Skylab mission (at the wavelengths of 8.34 and 15.4 A), the SO-212 film functioned as a photon detector, achieving spatial resolution of 2.2 arc sec. Other high-resolution soft-X-ray-sensitive films include SO-242 and 101-07. For XUV detection, the SC-5, SC-7, 104-07, and 101-07 films are recommended.

Hoover, Richard B.↗

Development of a mercuric iodide solid state spectrometer for X-ray astronomy

Mercuric iodide detectors, experimental development for astronomical use, X ray observations of the 1980 Cygnus X-1 High State, astronomical had X ray detectors in current use, detector development, balloon flight of large area (1500 sq cm) Phoswich detectors, had X ray telescope design, shielded mercuric iodide background measurement, Monte Carlo analysis, measurements with a shielded mercuric iodide detector are discussed.

Vallerga, J.↗

Icy Satellites of the Planets, and the Work of V.I. Moroz

The satellites of the giant planets are highly varied in size and density, indicating a wide range of compositions. The principal components of these satellites are ices of many different compositions (with H2O the most abundant) and varying amounts of silicate rocky material. Many different ices have been found by spectroscopic techniques both from Earth-based observatories and from planetary spacecraft. Three of the Galilean satellites of Jupiter exhibit H2O ice on their surfaces, while small amounts of CO2 are present on Ganymede and Callisto. The volcanic satellite Io has abundant SO2 ice and frost deposits. Saturn s satellites have surfaces dominated by H2O ice, but CO2 is also present on most of them, and in the cases of the low-albedo satellites Iapetus and Phoebe, there is evidence of complex hydrocarbons mixed with the surface materials. The large Uranian satellites also have H2O-dominated surfaces, but CO2 has also been discovered on two of them. Neptune s largest satellite, Triton, show spectroscopic evidence for six different ices, including N2, CH4, CO, CO2, H2O, and C2H6. The latter ice is a photochemical product from the action of sunlight on Triton's atmosphere. Pluto is similar to Triton, although CO2 has not been found. Pluto s large satellite, Charon, shows evidence for an ammonia hydrate on part of its surface. V. I. Moroz was a pioneer in the application of near-infrared detectors to astronomical sources. Using a prism spectrometer he measured the spectra of the Galilean satellites of Jupiter, and in 1966 he published the first near-infrared spectra, noting the appearance of H2O ice as a major component of Europa and Ganymede. This discovery, and the techniques of Moroz measurements help set the stage for the broad extension of the study of planetary, satellite, and asteroid surfaces through reflectance spectroscopy in the near-infrared.

Cruikshank, Dale P.↗

Self-scanned photodiode array - High performance operation in high dispersion astronomical spectrophotometry

A multichannel spectrophotometric detector system has been developed using a 1024 element self-scanned silicon photodiode array, which is now in routine operation with the high-dispersion coude spectrograph of the University of Texas McDonald Observatory 2.7-m telescope. Operational considerations in the use of such arrays for high precision and low light level spectrophotometry are discussed. A detailed description of the system is presented. Performance of the detector as measured in the laboratory and on astronomical program objects is described, and it is shown that these arrays are highly effective detectors for high dispersion astronomical spectroscopy.

Vogt, S. S.↗

Dual-Resonator Kinetic-Inductance Detector for Distinction between Signal and 1/ƒ Frequency Noise

Astronomical kinetic inductance detectors (KIDs), similar to quantum information devices, experience performance-limiting noise from materials. In particular, 1/ƒ (frequency) noise arises from two-level system defects (TLSs) in the circuit dielectrics and material interfaces and can be a dominant noise mechanism. Here, we present a dual-resonator KID (DuRKID), which is designed for improved noise-equivalent power relative to standard 1/ƒ -noise-limited KIDs. In this study we present the DuRKID schematic, a fabricated example, our first measurement results, a theoretical model including 1/ƒ noise, and a system-noise model containing additional noise sources. The circuit consists of two superconducting resonators sharing an electrical capacitance bridge of four capacitors, each of which hosts TLSs. The device is intended to operate using hybridization of the modes, which causes TLSs to either couple to one mode or the other, depending upon which capacitor they reside in. In contrast, the signal will affect a resonator inductance and, due to mode hybridization, this causes correlated frequency changes in both modes. Therefore, one can better distinguish the photon signal from the TLS frequency noise. To achieve hybridization, a TiN inductor is current biased to allow tuning of one bare-resonator mode into degeneracy with the other. Measurements show that the resonator modes hybridize as expected. The inter-resonator coupling and unintentional coupling of the two resonators to transmission lines are also characterized in measurements. A quantum information-science model allows device-parameter extraction from experimental data and a 1/ƒ noise analysis with uncorrelated noise. A system-noise analysis of the DuRKID, with comparisons to standard KIDs, is performed with generation-recombination noise and amplifier noise. The study reveals that the DuRKID can exhibit a large performance advantage over TLS-limited KID detectors.

N Forouzani↗

H2RG Detector Characterization for RIMAS and Instrument Efficiencies

The Rapid infrared IMAger-Spectrometer (RIMAS) is a near-infrared (NIR) imager and spectrometer that will quickly follow up gamma-ray burst afterglows on the 4.3-meter Discovery Channel Telescope (DCT). RIMAS has two optical arms which allows simultaneous coverage over two bandpasses (YJ and HK) in either imaging or spectroscopy mode. RIMAS utilizes two Teledyne HgCdTe H2RG detectors controlled by Astronomical Research Cameras, Inc. (ARC/Leach) drivers. We report the laboratory characterization of RIMAS's detectors: conversion gain, read noise, linearity, saturation, dynamic range, and dark current. We also present RIMAS's instrument efficiency from atmospheric transmission models and optics data (both telescope and instrument) in all three observing modes.

Toy, Vicki L.↗

Ccds: Their Cause and Cure

Charge coupled devices (CCDs) have opened new horizons in the optical astronomy. Most of the presently existing astronomical CCD systems are oriented and designed primarily for work on faint objects. The use of CCDs for high precision work on bright objects remains to be explored. Issues and problems specific to (CCDs) are covered in detail. The important structural characteristics of CCDs are that they are integrating, self scanned, photon counting (one selection for each detected photon), solid state devices. The typical physical sizes are of the order of 1 - 3 cm, and typical raster formats of 500x500 pixels (TI), 320x512 (RCA), 385x576 (GEC), 800x800 (TI), and 1500x1500 (GEC) should be available soon. Typical (and optimal) operating temperatures are around -100 C, with liquid N2 as the most common coolant. Some CCDs are physically warped. This causes focus variations across the surface, which amount to a spatially variable PSF. Other relevant properties of CCDs as detectors and a comparison with some other astronomical detectors are given.

Djorgovski, S.↗

Infrared Astronomical Satellite (IRAS) superfluid helium tank temperature control

The infrared detectors on the Infrared Astronomical Satellite (IRAS), which was placed into a polar orbit in January 1983, are cooled to a temperature of less than 3 K by thermal coupling to the main cryogenic tank (MCT) containing superfluid helium. A porous plug built into the vent line entrance acts as a superfluid helium liquid/vapor separator in zero gravity. A description of the IRAS MCT flight porous plug is presented, and tests of the plug in situ are discussed, taking into account submerged plug tests, a restart test, and a cold vapor flow test. Aspects of flow rate determination in the case of an unavailability of flight flow rate data are also considered.

Petrac, D.↗

Integrated detector array technology for infrared astronomy

The status of laboratory and telescope tests of integrated infrared detector array technology for astronomical applications is described. The devices tested represent a number of extrinsic and intrinsic detector materials and various multiplexer designs. Infrared arrays have now been used in successful astronomical applications. These have shown that device sensitivities can be comparable to those of discrete detector systems and excellent astronomical imagery can be produced.

Mccreight, c. R.↗

CALISTO: A Cryogenic Far-Infrared/Submillimeter Observatory

We present a design for a cryogenically cooled large aperture telescope for far-infrared astronomy in the wavelength range 30 micrometers to 300 micrometers. The Cryogenic Aperture Large Infrared Space Telescope Observatory, or CALISTO, is based on an off-axis Gregorian telescope having a 4 m by 6 m primary reflector. This can be launched using an Atlas V 511, with the only optical deployment required being a simple hinged rotation of the secondary reflector. The off-axis design, which includes a cold stop, offers exceptionally good performance in terms of high efficiency and minimum coupling of radiation incident from angles far off the direction of maximum response. This means that strong astronomical sources, such as the Milky Way and zodiacal dust in the plane of the solar system, add very little to the background. The entire optical system is cooled to 4 K to make its emission less than even this low level of astronomical emission. Assuming that detector technology can be improved to the point where detector noise is less than that of the astronomical background, we anticipate unprecedented low values of system noise equivalent power, in the vicinity of 10(exp -19) WHz(exp -0.5), through CALISTO's operating range. This will enable a variety of new astronomical investigations ranging from studies of objects in the outer solar system to tracing the evolution of galaxies in the universe throughout cosmic time.

Cryogenic Aperture Large Infrared Space Telescope ↗

Position-sensitive CdTe detector using improved crystal growth method

The feasibility of developing a position-sensitive CdTe detector array for astronomical observations in the hard X-ray, soft gamma ray region is demonstrated. In principle, it was possible to improve the resolution capability for imaging measurements in this region by orders of magnitude over what is now possible through the use of CdTe detector arrays. The objective was to show that CdTe crystals of the quality, size and uniformity required for this application can be obtained with a new high pressure growth technique. The approach was to fabricate, characterize and analyze a 100 element square array and several single-element detectors using crystals from the new growth process. Results show that detectors fabricated from transversely sliced, 7 cm diameter wafers of CdTe exhibit efficient counting capability and a high degree of uniformity over their entire areas. A 100 element square array of 1 sq mm detectors was fabricated and operated.

Source record↗