Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Vertical-cavity surface-emitting lasers with intracavity contacts and a rhomboidal current aperture for compact atomic clocks

Single-mode vertical-cavity surface-emitting lasers (VCSELs) with intracavity contacts, composite distributed Bragg reflectors, and a rhomboidal selectively-oxidised current aperture are studied. It is shown that the use of a rhomboidal current aperture allows the light output polarisation to be fixed without using a special surface relief and leads to efficient narrowing of the emission line with retaining a high slope efficiency. The developed VCSELs have a high output power (exceeding 1 mW), a threshold current below 1 mA, an effective modulation frequency exceeding 5 GHz, and a linewidth smaller than 60 MHz at increased (65 – 75 °C) temperatures and are promising for application in compact Cs vapour cell atomic clocks. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical atomic clock aboard an Earth-orbiting space station (OACESS): enhancing searches for physics beyond the standard model in space

We present a concept for a high-precision optical atomic clock (OAC) operating on an Earth-orbiting space station. This pathfinder science mission will compare the space-based OAC with one or more ultra-stable terrestrial OACs to search for space-time-dependent signatures of dark scalar fields that manifest as anomalies in the relative frequencies of station-based and ground-based clocks. This opens the possibility of probing models of new physics that are inaccessible to purely ground-based OAC experiments where a dark scalar field may potentially be strongly screened near Earth's surface. This unique enhancement of sensitivity to potential dark matter candidates harnesses the potential of space-based OACs.

79 ASTRONOMY AND ASTROPHYSICS↗

Rydberg Spectroscopy in an Optical Lattice: Blackbody Thermometry for Atomic Clocks

We show that optical spectroscopy of Rydberg states can provide accurate in situ thermometry at room temperature. Transitions from a metastable state to Rydberg states with principal quantum numbers of 25-30 have 200 times larger fractional frequency sensitivities to blackbody radiation than the strontium clock transition. We demonstrate that magic-wavelength lattices exist for both strontium and ytterbium transitions between the metastable and Rydberg states. Frequency measurements of Rydberg transitions with 10{sup -16} accuracy provide 10 mK resolution and yield a blackbody uncertainty for the clock transition of 10{sup -18}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of trapped-ion heating on generalised Ramsey methods for suppressing frequency shifts caused by a probe field in atomic clocks

Based on a simple one-dimensional model, we consider the effect of trapped-ion heating on the efficiency of generalised Ramsey methods for the probe-induced frequency shift suppression in optical frequency standards based on single ultracold ions. It is shown that ion heating reduces the efficiency of all previously proposed one-loop generalised Ramsey methods, leading in all cases to the appearance of a linear dependence of the reference frequency shift on the residual field frequency shift. Two versions of the most heating stable generalised Ramsey schemes, for which the proportionality coefficient in this dependence is minimal, are demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clocked atom delivery to a photonic crystal waveguide

Experiments and numerical simulations are described that develop quantitative understanding of atomic motion near the surfaces of nanoscopic photonic crystal waveguides (PCWs). Ultracold atoms are delivered from a moving optical lattice into the PCW. Synchronous with the moving lattice, transmission spectra for a guided-mode probe field are recorded as functions of lattice transport time and frequency detuning of the probe beam. By way of measurements such as these, we have been able to validate quantitatively our numerical simulations, which are based upon detailed understanding of atomic trajectories that pass around and through nanoscopic regions of the PCW under the influence of optical and surface forces. The resolution for mapping atomic motion is roughly 50 nm in space and 100 ns in time. By introducing auxiliary guided-mode (GM) fields that provide spatially varying AC Stark shifts, we have, to some degree, begun to control atomic trajectories, such as to enhance the flux into the central vacuum gap of the PCW at predetermined times and with known AC Stark shifts. In conclusion, applications of these capabilities include enabling high fractional filling of optical trap sites within PCWs, calibration of optical fields within PCWs, and utilization of the time-dependent, optically dense atomic medium for novel nonlinear optical experiments.

36 MATERIALS SCIENCE↗

Low SWaP Trapped Ion Atomic Clock

For this project we attempted to show signature traits of excellent optical clock performance in a trapped ion system which had an integrated photonic delivery system for all clock algorithm beams. These traits were 1) Contrast for the clock transition, 2) Coherence of the clock transition, and 3) ion lifetime. We were partially successful and were able to demonstrate the clock laser portion of an optical clock with $\sim 4.4 \text{x} 10^{-14}/\sqrt{\tau}$ fractional frequency instability. Additionally, we made progress towards a background-free detection method.

42 ENGINEERING↗

Low-frequency, self-sustained oscillations in inductively coupled plasmas used for optical pumping

We have investigated very low frequency, on the order of one hertz, self-pulsing in alkali-metal inductively-coupled plasmas (i.e., rf-discharge lamps). This self-pulsing has the potential to significantly vary signal-to-noise ratios and (via the ac-Stark shift) resonant frequencies in optically pumped atomic clocks and magnetometers (e.g., the atomic clocks now flying on GPS and Galileo global navigation system satellites). The phenomenon arises from a nonlinear interaction between the atomic physics of radiation trapping and the plasma's electrical nature. To explain the effect, we have developed an evaporation/condensation theory (EC theory) of the self-pulsing phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technique of pulsed optical pumping and pulsed excitation of microwave resonances using the Ramsey scheme in a {sup 87}Rb cell with a buffer gas

A laboratory prototype of a compact quantum frequency standard based on a rubidium vapour cell with pulsed laser pumping is developed. With significantly smaller overall dimensions (a volume of ∼10 L and a mass of ∼10 kg), the frequency standard is expected to have the short-term instability comparable with that of the commercial passive hydrogen masers and even the laboratory fountain-type atomic clocks based on cold atoms. The advantages of the technique of pulsed optical pumping and pulsed excitation of microwave resonances over the traditional techniques of double radio-optical resonance detection are substantiated. The results of the experimental study of pulsed optical pumping of a rubidium cell with a mixture of buffer Ar – Ne gases implemented at the VNIIFTRI are presented, the Ramsey resonances are obtained, and the process of optimising the contrast of the central resonance peak is described. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-squeezed vector atomic magnetometry

Atomic magnetometers based on Zeeman shift measurement have the potential for high sensitivity and long-term stability. Like other atomic sensors, including atomic clocks and atom interferometers, the atomic magnetometer could, in principle, be augmented with spin squeezing for further sensitivity enhancement. However, existing atomic magnetometers are not compatible with spin squeezing because the atoms can hardly be in a pure quantum state during operation. Moreover, a natural challenge faced by an atomic magnetometer is the arbitrary direction of the magnetic field. In this paper, we propose a cold-atom-based magnetometer with spin squeezing that can measure both the magnitude and the direction of an arbitrary magnetic field. For experimentally accessible parameters, we show that the technique described above could potentially achieve a sensitivity nearly two orders of magnitude higher than that of the best existing magnetometers.

Li, Jinyang [Northwestern U.] (ORCID:0000000194328↗