Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic dark matter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The non-relativistic effective field theory of dark matter-electron interactions

Electronic excitations in atomic, molecular, and crystal targets are at the forefront of the ongoing search for light, sub-GeV dark matter (DM). In many light DM-electron interactions the energy and momentum deposited is much smaller than the electron mass, motivating a non-relativistic (NR) description of the electron. Thus, for any target, light DM-electron phenomenology relies on understanding the interactions between the DM and electron in the NR limit. In this work we derive the NR effective field theory (EFT) of general DM-electron interactions from a top-down perspective, starting from general high-energy DM-electron interaction Lagrangians. This provides an explicit connection between high-energy theories and their low-energy phenomenology in electron excitation based experiments. Furthermore, we derive Feynman rules for the DM-electron NR EFT, allowing observables to be computed diagrammatically, which can systematically explain the presence of in-medium screening effects in general DM models. We use these Feynman rules to compute absorption, scattering, and dark Thomson scattering rates for a wide variety of high-energy DM models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter Reconstruction in LBAI Experiments with Imperfect Data

Long-baseline atom interferometer (LBAI) experiments offer unprecedented sensitivity to ultralight scalar dark matter (DM) [1], however reconstruction of a putative DM signal with traditional frequency-domain analysis requires ``perfect data (i.e., regularly-sampled with no missing samples). In a real LBAI experiment, there will undoubtedly be imperfections in the data leading to downtime. This downtime can arise from operational considerations (e.g., maintenance), the operational environment (motion of people and animals [2] or elevators), and robustness of the experimental apparatus (e.g., bad atom launches). In this work, we investigate the impact of various downtime models on the overall DM sensitivity of such an experiment. We compare the sensitivity for each downtime model as determined by a ``compound FFT analysis to a baseline no-downtime case. We also show how much sensitivity can be regained by moving to a Lomb-Scargle frequency analysis, as in [2]. Furthermore, we demonstrate reconstruction of the DM wave s phase as well as its frequency. [1] D. Antypas, et al, ``New Horizons: Scalar and Vector Ultralight Dark Matter (2022). arXiv:2203.14915 [2] J. Carlton and C. McCabe, ``From RATs to riches: mitigating anthropogenic and synanthropic noise in atom interferometer searches for ultra-light dark matter (2023). arXiv:2308.101731

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing strontium clock atom interferometry using quantum optimal control

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. In conclusion, this could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-baseline quantum sensor network as dark matter haloscope

Ultralight dark photons constitute a well-motivated candidate for dark matter. A coherent electromagnetic wave is expected to be induced by dark photons when coupled with Standard-Model photons through kinetic mixing mechanism, and should be spatially correlated within the de Broglie wavelength of dark photons. Here we report the first search for correlated dark-photon signals using a long-baseline network of 15 atomic magnetometers, which are situated in two separated meter-scale shield rooms with a distance of about 1700 km. Both the network’s multiple sensors and the shields large size significantly enhance the expected dark-photon electromagnetic signals, and long-baseline measurements confidently reduce many local noise sources. Using this network, we constrain the kinetic mixing coefficient of dark photon dark matter over the mass range 4.1 feV-2.1 peV, which represents the most stringent constraints derived from any terrestrial experiments operating over the aforementioned mass range. Our prospect indicates that future data releases may go beyond the astrophysical constraints from the cosmic microwave background and the plasma heating.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effective electric field: Quantifying the sensitivity of searches for new -odd physics with EuCl 3 ∙ 6H 2 O

Laboratory-scale precision experiments are a promising approach to searching for physics beyond the standard model. Noncentrosymmetric solids offer favorable statistical sensitivity for efforts that search for new fields, whose interactions violate the discrete parity and time-reversal symmetries. One example is the cosmic axion spin precession experiment (CASPEr), which can be sensitive to the defining interaction of the quantum chromodynamics (QCD) axion dark matter with gluons in atomic nuclei. The effective electric field is the parameter that quantifies the sensitivity of such experiments to new physics. We describe the theoretical approach to calculating the effective electric field for noncentrosymmetric sites in ionic insulating solids. We consider the specific example of the crystal, which is a particularly promising material. The optimistic estimate of the effective electric field for the isotope in this crystal is . The calculation uncertainty is estimated to be two orders of magnitude, dominated by the evaluation of the europium nuclear Schiff moment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray-line coincidence photopumping in a potassium-chlorine mixed plasma

Exploiting the multiple long pulse capability and suite of x-ray diagnostics of the Orion laser, we have set out to explore line coincidence photopuming—the enhancement in population of an atomic level brought on by resonant absorption of x rays from a different emitting ion. Unlike previous work, the two ions are in the same plasma and so the experiment is an x-ray analog of the well-known Bowen resonance fluorescence mechanism that operates in astrophysical situations in the optical region. Herein, our measurements have shown enhanced fluorescence in a chlorine plasma, attributable to line coincident photopumping from co-mixed potassium ions. To detect this relatively low signal-to-noise phenomenon, the data from multiple shots are combined, and the statistical method of bootstrapping is used to assign a confidence value to the measured enhancement, resulting in an estimate of the enhancement of 39 ± 18 16 % compared to the null case, where no pumping occurs. The experimental results have been compared to coupled radiation-transport and radiation hydrodynamics simulations using the CRETIN code together with the NYM radiation hydrodynamics model and agreement has been found, with the simulations also predicting modest enhancement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Search for the Migdal effect in liquid xenon with keV-level nuclear recoils

The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the Migdal effect for M- and L-shell electrons in liquid xenon using nuclear recoils produced by tagged neutron scatters. Despite an observed background rate lower than that of expected signals in the region of interest, we do not observe a signal consistent with predictions. We discuss possible explanations, including inaccurate predictions for either the Migdal rate or the signal response in liquid xenon. We comment on the implications for direct dark matter searches and future Migdal characterization efforts. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GD-1 Stellar Stream and Cocoon in the DESI Early Data Release

We present ∼115 new spectroscopically identified members of the GD-1 tidal stream observed with the 5000-fiber Dark Energy Spectroscopic Instrument (DESI). We confirm the existence of a “cocoon,” which is a broad (FWHM ∼ 2:932 ∼ 460 pc) and kinematically hot (velocity dispersion, σ ∼ 5–8 km s −1 ) component that surrounds a narrower (FWHM ∼ 0:353 ∼ 55 pc) and colder [(σ = 3.09 ± 0.76 km s −1 )] thin stream component (based on a median per star velocity precision of 2.7 km s −1 ). The cocoon extends over at least a 30 ∘ segment of the stream observed by DESI. The thin and cocoon components have similar mean values of [Fe/H]: −2.54 ± 0.04 dex and −2.47 ± 0.06 dex, suggestive of a common origin. The data are consistent with the following scenarios for the origin of the cocoon. The progenitor of the GD-1 stream was an accreted globular cluster (GC) and: (a) the cocoon was produced by pre-accretion tidal stripping of the GC while it was still inside its parent dwarf galaxy; (b) the cocoon comprises debris from the parent dwarf galaxy; (c) an initially thin GC tidal stream was heated by impacts from dark subhalos in the Milky Way; (d) an initially thin GC stream was heated by a massive Sagittarius dwarf galaxy; or a combination of some of these. Future DESI spectroscopy and detailed modeling may enable us to distinguish between these possible origins.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on fifth forces and ultralight dark matter from OSIRIS-REx target asteroid Bennu

It is important to test the possible existence of fifth forces, as ultralight bosons that would mediate these are predicted to exist in several well-motivated extensions of the Standard Model. Recent work indicated asteroids as promising probes, but applications to real data are lacking so far. Here we use the OSIRIS-REx mission and ground-based tracking data for the asteroid Bennu to derive constraints on fifth forces. Our limits are strongest for mediator masses m ~ (10 -18 -10 -17 ) eV, where we currently achieve the tightest bounds. These can be translated to a wide class of models leading to Yukawa-type fifth forces, and we demonstrate how they apply to U(1) B dark photons and baryon-coupled scalars. Our results demonstrate the potential of asteroid tracking in probing well-motivated extensions of the Standard Model and ultralight bosons near the fuzzy dark matter range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals. Several mitigations will be enacted, including mu-metal shielding and a suite of magnetometers. This presentation will discuss the development of a magnetic field monitoring system based on commercial magneto-inductive sensors to be installed at several points along the interferometer.

Arce, Edwin [Unlisted; Fermilab]↗

Development of a magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals; static magnetic fields must also be tightly controlled to manage measurement resolution. Several tools are being applied to the problem, including mu-metal shielding, field biasing, and a suite of magnetometers. This report details the development of a magnetic field monitoring system to be built from commercially available parts and installed at seventeen locations, one for each of the modular sections making up the length of the MAGIS-100 apparatus.

Arce, Edwin [Unlisted, US, CA]↗

DarkSide-20k sensitivity to light dark matter particles

The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV c$^{−2}$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV c$^{−2}$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP–nucleon interaction cross-sections below 1 × 10$^{−42}$ cm$^{2}$ is achievable for WIMP masses above 800 MeV c$^{−2}$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV c$^{−2}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fully ab-initio all-electron calculation of dark matter-electron scattering in crystals with evaluation of systematic uncertainties

We calculate target-material responses for dark matter–electron scattering at the all-electron level using atom-centered Gaussian basis sets. The all-electron effects enhance the material response at high momentum transfers from dark matter to electrons, q ≳ O ( 10 α m e ) , compared to calculations using conventional plane wave methods, including those used in ; this enhances the expected event rates at energy transfers E ≳ 10 eV , especially when scattering through heavy mediators. We carefully test a range of systematic uncertainties in the theory calculation, including those arising from the choice of basis set, exchange-correlation functional, number of unit cells in the Bloch sum, k -mesh, and neglect of scatters with very high momentum transfers. We provide state-of-the-art crystal form factors, focusing on silicon and germanium. Our code and results are made publicly available as a new tool, called (“”). Published by the American Physical Society 2024

Dreyer, Cyrus E.↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗