Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Updated evaluation of potential ultralow Q -value β -decay candidates

“Ultralow” Q-value β decays are referred to as such due to their low decay energies of less than ≈1 keV. Such a low energy decay is possible when the parent nucleus decays to an excited state in the daughter, with an energy close to that of the Q value. These decays are of interest as potential new candidates for neutrino mass determination experiments and as a testing ground for studies of atomic interference effects in the nuclear decay process. In this paper, we provide an updated evaluation of atomic mass data and nuclear energy-level data to identify potential ultralow Q-value β decay candidates. For many of these candidates, more precise and accurate atomic mass data is needed to determine if the Q value of the potential ultralow decay branch is energetically allowed and in fact ultralow. Furthermore, the relevant precise atomic mass measurements can be achieved via Penning trap mass spectrometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurement of 27 P to constrain type-I x-ray burst models and validate the isobaric multiplet mass equation for the $A = 27, T = \frac{3}{2}$ isospin quartet

Background: Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in rp process reaction rates, which can be reduced via precision mass measurements of neutron-deficient isotopes in the rp process path. Purpose: Perform a precise atomic mass measurement of 27 P. Use this new measurement to calculate rp process reaction rates and input these rates into an x-ray burst model to reduce simulated light curve uncertainty. Use the mass measurement of 27 P to validate the isobaric multiplet mass equation (IMME) for the A = 27 T = 3/2 isospin quartet which 27 P belongs to. Method: High-precision Penning trap mass spectrometry utilizing the time-of-flight ion cyclotron resonance technique was used to determine the atomic mass of 27 P. The MESA code (Modules for Experiments in Stellar Astrophysics) was then used to simulate x-ray bursts using a one-dimensional multizone model to produce updated light curves. Results: The mass excess of 27 P was measured to be –670.7(6) keV, a 14-fold precision increase over the mass reported in the 2020 Atomic Mass Evaluation (AME2020). The 26 Si(p, $γ$) 27 P– 27 P($γ$, p) 26 Si rate equilibrium has been determined to a higher precision based on the precision mass measurement of 27 P. x-ray burst light curves were produced with the MESA code using the new reaction rates. Changes in the mass of 27 P seem to have minimal effect on light curves, even in burster systems tailored to maximize impact. Conclusion: The mass of 27 P does not play a significant role in x-ray burst light curves. It is important to understand that more advanced models do not just provide more precise results, but often qualitatively different ones. This result brings us a step closer to being able to extract stellar parameters from individual x-ray burst observations. In addition, the IMME has been validated for the A = 27, T = 3/2 quartet. The normal quadratic form of the IMME using the latest data yields a reduced $χ$ 2 of 2.9. Finally, the cubic term required to generate an exact fit to the latest data matches theoretical attempts to predict this term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quadruple Langmuir probe characterization of different fuel gases in a plasma deflagration accelerator

Astrophysical flows may be studied by reproducing similar conditions using a coaxial plasma accelerator operating in the deflagration regime (or plasma deflagration accelerator). This allows for the recreation and investigation of dynamics present in complex highly coupled plasma systems at the laboratory scale. Here we report on measurements of the plasma density, temperature, plasma potential and velocity found using a quadruple Langmuir probe (QLP) on such a deflagration accelerator in the form of the Stanford Coaxial High ENerGy (CHENG) device operating with multiple gases – specifically argon, nitrogen and hydrogen. Experiments show a general decrease in bulk plasma velocity with gas atomic mass from upwards of 120 km s –1 with hydrogen to less than 30 km s –1 with argon. There was an accompanying increase in peak plasma density with increasing atomic mass from ~3 × 10 20 m –3 with hydrogen to ~1.5 × 10 21 m –3 with argon. It was found that the momentum flux and internal energy density also generally increase with atomic mass while the particle flux is constant between shots. Further investigation is needed to understand these correlations and the underlying physics. Lastly, comparisons with scaling laws show that while the CHENG device may be operated in such a way as to simulate the effects of bulk solar wind movement, it may not properly capture the thermal effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence for chain molecules enriched in carbon, hydrogen, and oxygen in comet Halley

In situ measurements of the composition and spatial distribution of heavy thermal positive ions in the coma of comet Halley were made with the heavy-ion analyzer RPA2-PICCA aboard the Giotto spacecraft. Above 50 atomic mass units an ordered series of mass peaks centered at 61, 75, 91, and 105 atomic mass units were observed. Each peak appears to be composed of three or more closely spaced masses. The abundances decrease and the dissociation rates increase smoothly with increasing mass. These observations suggest the presence of chain molecules that are enriched in carbon, oxygen, and hydrogen, such as polyoxymethylene (polymerized formaldehyde), in comet Halley.

Mitchell, D. L.↗

Comparing the kinetics of ionized and neutral atoms from single and multi-element laser-produced plasmas

In this work, kinetics of ion and neutral atom emission features were compared for nanosecond laser-produced plasmas generated from several metal targets (i.e., Al, Ti, Zr, Nb, Ta) and an alloy containing all of these as principal alloying elements. Plasmas were produced by focusing 6 ns, 1064 nm pulses from an Nd:YAG laser on the targets of interest in a vacuum. A Faraday cup was used for collecting ion temporal features while spatially and temporally resolved emission spectroscopy was used for measuring the optical time of flight of various neutral atomic transitions. Our results highlight that most probable ion and atom velocities decay with increasing atomic mass. Trends for ions from the alloy target represent a weighted average where all ions contribute. For both ions and atoms, velocities decrease with increasing heat of vaporization and melting temperature, consistent with the thermal mechanisms that contribute to nanosecond laser ablation. Kinetic energies for neutral atoms from pure metal targets have some variability with atomic mass, whereas kinetic energies for atoms from the alloy target are more similar. These more similar kinetic energies observed for neutral atoms in the multi-element plasma may be attributed to collisions between species from all elements in the Knudsen layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnesium and Titanium Isotopic Compositions of an Unusual Hibonite-Perovskite Refractory Inclusion from Allende: It Is Fun

Introduction: Hibonite-rich refractory inclusions are among the first solids that formed in the solar nebula, and thus provide constraints on the earliest environment in the Solar System. An unusual hibonite-perovskite inclusion from Allende, SHAL, consists of a large (approximately 500 by 200 microns) single hibonite crystal and coexisting blocky perovskite (approximately 200 microns in size). The hibonite is characterized by chemical and oxygen isotopic compositions similar to those in the FUN (Fractionated and Unknown Nuclear anomalies) inclusion HAL. However, the rare earth element (REE) patterns measured at different spots of SHAL hibonite are highly variable, ranging from Group II-like (light REEs enriched relative to heavy REEs) to Group III-like (relatively flat with slight Eu depletions), but overall contrast largely with that of HAL, especially in the Ce and Yb abundances. This implies that SHAL hibonite formed and underwent distillation processes under more reducing conditions. Interestingly, the accompanying perovskite has uniform, unfractionated oxygen isotopic compositions (averaging delta (sup 17) O equals delta (sup 18) O equals −7 per mille) and REE abundances that are completely different from those of SHAL hibonite. This has been interpreted that perovskite and hibonite may not be co-genetic. Here we performed Al-Mg and Ti isotopic measurements of SHAL hibonite and perovskite to determine if the FUN characteristics are observed in these two isotope systems, and to further constrain the origin and evolution of SHAL. Results: Isotopic measurements of Al-Mg and Ti in SHAL were performed on the UCLA CAMECA ims-1290 ion microprobe by following the analytical protocols described in [1]. The Al-Mg and Ti data obtained in both terrestrial standards and SHAL hibonite and perovskite are shown below. Both SHAL hibonite and perovskite, despite very high (sup 27) Al to (sup 24) Mg ratios, are devoid of (sup 26) Mg excesses that can be attributed to the decay of (sup 26) Al. Delta (sup 25) Mg (mass-dependent fractionation) in hibonite is approximately −5 per mille per atomic mass unit relative to Madagascar hibonite, but is not well constrained for perovskite due to very large uncertainties owing to extremely low Mg contents. Similar to Mg isotopes, SHAL hibonite and perovskite show essentially the same Ti isotopic compositions, with anomalies in (sup 50) Ti of approximately 14 per mille, but the former shows greater Ti isotope fractionation than the latter (2.5 per mille per atomic mass unit versus 0 per mille). Discussion and Conclusions: The Al-Mg and Ti isotopic compositions of SHAL hibonite are consistent with those of HAL, suggesting that SHAL hibonite is a FUN inclusion and likely formed prior to homogenization of (sup 26) Al and Ti isotope variations in the solar nebula. However, the formation mechanisms for SHAL and HAL differ, given the differences in the REE patterns and degrees of oxygen mass-dependent fractionation. The Group-II to Group-III like REE patterns, the Yb depletions, and negative delta (sup 25) Mg observed in SHAL hibonite are all consistent with condensation of the hibonite precursor in a reducing environment.. The lack of large Ce depletions in SHAL hibonite implies that distillation processes that fractionated hibonite's oxygen isotopes must have taken place under a reducing condition, but the extent to which SHAL hibonite was distilled appears to be less than HAL because of the smaller degree of oxygen mass-dependent fractionation. The perovskite shares essentially the same Ti and Mg isotopic compositions as hibonite and probably formed in the same reservoir.. The ultrarefractory REE pattern seen in perovskite likely resulted from gas-solid fractionation which depleted HREEs in this reservoir. This process also explains why SHAL hibonite is generally depleted in HREEs relative to LREEs.

Liu, M.-C.↗

Status of CHIP-TRAP: The Central Michigan University High-Precision Penning Trap

Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (~1 part in 10 11 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Attosecond Time Delay Trends across the Isoelectronic Noble Gas Sequence

The analysis and measurement of Wigner time delays can provide detailed information about the electronic environment within and around atomic and molecular systems, with one the key differences being the lack of a long-range potential after a halogen ion undergoes photoionization. In this work, we use relativistic random-phase approximation to calculate the average Wigner delay from the highest occupied subshells of the atomic pairings (2p, 2s in Fluorine, Neon), (3p, 3s in Chlorine, Argon), (4p, 4s, 3d, in Bromine, Krypton), and (5p, 5s, 4d in Iodine, Xenon). The qualitative behaviors of the Wigner delays between the isoelectronic pairings were found to be similar in nature, with the only large differences occurring at photoelectron energies less than 20 eV and around Cooper minima. Interestingly, the relative shift in Wigner time delays between negatively charged halogens and noble gases decreases as atomic mass increases. All atomic pairings show large differences at low energies, with noble gas atoms showing large positive Wigner delays, while negatively charged halogen ions show negative delays. The implications for photoionization studies in halide-containing molecules is also discussed.

Grafstrom, Brock↗

Graphic Three-Axes Presentation of Residual Gas Analyser Data

Residual gas analyzers (RGA) are commonly used to measure the composition of residual gases in thermal-vacuum test chambers. Measurements from RGAs are often used to identify and quantify outgassing contaminants from a test article during thermal-vacuum testing. RGA data is typically displayed as snapshots in time, showing instantaneous concentrations of ions from ionized residual gas molecules at different atomic masses. A method was devised by the authors to present RGA data in a three-axis format, plotting atomic mass unit (AMU), ion concentration as a function of AMU, and time, to provide a clear graphic visualization ot trends in gas concentration changes and to initiate a valuable analytical tool to interpret test article outgassing rates during thermal-vacuum testing.

data analysis↗

Noble gas adsorption to tuff

For this report a method was developed to measure trace noble gas element adsorption to the surfaces of geologic materials in the presence of a background gas that could potentially compete for surface adsorption sites. Adsorption of four noble gas elements (Ne, Ar, Kr, and Xe) at a concentration of 100 ppm in helium and nitrogen were measured on a sample of crushed tuff at 0, 15, 30, and 45°C. In addition, Ne, Ar, Kr, and Xe at 250 ppm and 500 ppm in nitrogen at 15°C were measured. Noble gas adsorption was found to increase with increasing atomic mass and decreasing temperature. It was also observed that the relative increase in noble gas element adsorption with decreasing temperature tends to increase with increasing atomic mass. Noble gas adsorption from nitrogen was approximately an order of magnitude greater than for the noble gases in helium. As the noble gas concentrations in nitrogen increased, adsorption increased in a slightly non-linear fashion which could be modeled using a Freundlich isotherm. For noble gas concentrations that were ≤100 ppm Henry's Law constant were calculated.

58 GEOSCIENCES↗

Isotopic stack - measurement of heavy cosmic ray isotopes

Heavy cosmic ray nuclei with nuclear charge, Z, equal to or greater than 3 are to be measured using an isotopic stack consisting of passive visual track detectors which remain sensitive throughout the entire mission. The scientific data are stored in latent tracks which are produced by heavy ions and which can be revealed in the investigator's laboratory after recovery. During the mission, only housekeeping data have to be collected. The exposure onboard Spacelab 1 allows the study of the chemical composition and energy spectrum of articles which have energies in the range 20 to 100 million electron volts per atomic mass unit, as well as the isotopic composition of heavy galactic cosmic rays with energies in the range 100 to 1000 million electron volts per atomic mass unit.

Beaujean, R.↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heavy-element production in a compact object merger observed by JWST

The mergers of binary compact objects such as neutron stars and black holes are of central interest to several areas of astrophysics, including as the progenitors of gamma-ray bursts (GRBs), sources of high-frequency gravitational waves (GWs) and likely production sites for heavy-element nucleosynthesis by means of rapid neutron capture (the r -process). Here we present observations of the exceptionally bright GRB 230307A. We show that GRB 230307A belongs to the class of long-duration GRBs associated with compact object mergers and contains a kilonova similar to AT2017gfo, associated with the GW merger GW170817. We obtained James Webb Space Telescope (JWST) mid-infrared imaging and spectroscopy 29 and 61 days after the burst. The spectroscopy shows an emission line at 2.15 microns, which we interpret as tellurium (atomic mass A = 130) and a very red source, emitting most of its light in the mid-infrared owing to the production of lanthanides. These observations demonstrate that nucleosynthesis in GRBs can create r -process elements across a broad atomic mass range and play a central role in heavy-element nucleosynthesis across the Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Light nuclei collectivity from s NN = 3 GeV Au+Au collisions at RHIC

In high-energy heavy-ion collisions, partonic collectivity is evidenced by the constituent quark number scaling of elliptic flow anisotropy for identified hadrons. A breaking of this scaling and dominance of baryonic interactions is found for identified hadron collective flow measurements in sNN = 3 GeV Au+Au collisions. In this paper, we report measurements of the first- and second-order azimuthal anisotropic parameters, v1 and v2, of light nuclei (d, t, 3He, 4He) produced in sNN = 3 GeV Au+Au collisions at the STAR experiment. An atomic mass number scaling is found in the measured v1 slopes of light nuclei at mid-rapidity. For the measured v2 magnitude, a strong rapidity dependence is observed. Unlike v2 at higher collision energies, the v2 values at mid-rapidity for all light nuclei are negative and no scaling is observed with the atomic mass number. Calculations by the Jet AA Microscopic Transport Model (JAM), with baryonic mean-field plus nucleon coalescence, are in good agreement with our observations, implying baryonic interactions dominate the collective dynamics in 3 GeV Au+Au collisions at RHIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlating Nanoscale Secondary Ion Mass Spectrometry and Atom Probe Tomography Analysis of Uranium Enrichment in Metallic Nuclear Fuel

Distribution and enrichment of 235U within nuclear fuels are essential to material performance and reactor safety. With the development of metallic U fuels, understanding 235U homogeneity has become increasingly important, however, it is difficult to map with high spatial, and mass resolution to analyze both matrix and secondary phase precipitates. Here, we analyze 235U enrichment in matrix and carbide phases in LEU-Mo via two chemical imaging modalities: nanoscale secondary ion mass spectrometry (nanoSIMS) and atom probe tomography (APT). NanoSIMS and APT provided consistent results, with no statistically significant difference between measured and nominal enrichment (19.75 % 235U).

U-10Mo, atom probe tomography, nanoscale secondary↗

Cometary particulate analyzer

A concept for determining the relative abundance of elements contained in cometary particulates was evaluated. The technique utilizes a short, high intensity burst of laser radiation to vaporize and ionize collected particulate material. Ions extracted from this laser produced plasma are analyzed in a time of flight mass spectrometer to yield an atomic mass spectrum representative of the relative abundance of elements in the particulates. Critical aspects of the development of this system are determining the ionization efficiencies for various atomic species and achieving adequate mass resolution. A technique called energy-time focus, which utilizes static electric fields to alter the length of the ion flight path in proportion to the ion initial energy, was used which results in a corresponding compression to the range of ion flight times which effectively improves the inherent resolution. Sufficient data were acquired to develop preliminary specifications for a flight experiment.

Friichtenicht, J. F.↗