Automatic Calibration Systems

A continuous requirement exists for calibration and environmental testing of instruments in use at multitude of test facilities at Langley Research Center. Brief summarizes several automated systems available for calibration of research instruments to include: six-component balance, multimeter, amplifier, pyrometer, voltage-controlled oscillator, pressure transducer and accelerometer.

Ferris, A. T.↗

Automatic calibration of space based manipulators and mechanisms

Four tasks in manipulator kinematic calibration are summarized. Calibration of a seven degree of freedom manipulator was simulated. A calibration model is presented that can be applied on a closed-loop robot. It is an expansion of open-loop kinematic calibration algorithms subject to constraints. A closed-loop robot with a five-bar linkage transmission was tested. Results show that the algorithm converges within a few iterations. The concept of model differences is formalized. Differences are categorized as structural and numerical, with emphasis on the structural. The work demonstrates that geometric manipulators can be visualized as points in a vector space with the dimension of the space depending solely on the number and type of manipulator joint. Visualizing parameters in a kinematic model as the coordinates locating the manipulator in vector space enables a standard evaluation of the models. Key results include a derivation of the maximum number of parameters necessary for models, a formal discussion on the inclusion of extra parameters, and a method to predetermine a minimum model structure for a kinematic manipulator. A technique is presented that enables single point sensors to gather sufficient information to complete a calibration.

Everett, Louis J.↗

Automatic Calibration Of Manual Machine Tools

Modified scheme uses data from multiple positions and eliminates tedious positioning. Modification of computer program adapts calibration system for convenient use with manually-controlled machine tools. Developed for use on computer-controlled tools. Option added to calibration program allows data on random tool-axis positions to be entered manually into computer for reduction. Instead of setting axis to predetermined positions, operator merely sets it at variety of arbitrary positions.

Gurney, Rex D.↗

First International Symposium on Strain Gauge Balances

The first International Symposium on Strain Gauge Balances was sponsored and held at NASA Langley Research Center during October 22-25, 1996. The symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. Over 130 delegates from 15 countries were in attendance. The program opened with a panel discussion, followed by technical paper sessions, and guided tours of the National Transonic Facility (NTF) wind tunnel, a local commercial balance fabrication facility, and the LaRC balance calibration laboratory. The opening panel discussion addressed "Future Trends in Balance Development and Applications." Forty-six technical papers were presented in 11 technical sessions covering the following areas: calibration, automatic calibration, data reduction, facility reports, design, accuracy and uncertainty analysis, strain gauges, instrumentation, balance design, thermal effects, finite element analysis, applications, and special balances. At the conclusion of the Symposium, a steering committee representing most of the nations and several U.S. organizations attending the Symposium was established to initiate planning for a second international balance symposium, to be held in 1999 in the UK.

John S Tripp↗

First International Symposium on Strain Gauge Balances

The first International Symposium on Strain Gauge Balances was sponsored and held at NASA Langley Research Center during October 22-25, 1996. The symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. Over 130 delegates from 15 countries were in attendance. The program opened with a panel discussion, followed by technical paper sessions, and guided tours of the National Transonic Facility (NTF) wind tunnel, a local commercial balance fabrication facility, and the LaRC balance calibration laboratory. The opening panel discussion addressed "Future Trends in Balance Development and Applications." Forty-six technical papers were presented in 11 technical sessions covering the following areas: calibration, automatic calibration, data reduction, facility reports, design, accuracy and uncertainty analysis, strain gauges, instrumentation, balance design, thermal effects, finite element analysis, applications, and special balances. At the conclusion of the Symposium, a steering committee representing most of the nations and several U.S. organizations attending the Symposium was established to initiate planning for a second international balance symposium, to be held in 1999 in the UK.

Tripp, John S↗

Automatic PCM guard-band selector and calibrator

Automatic method for selection of proper guard band eliminates human error and speeds up calibration process. There is also an option which allows a single channel to be calibrated, independently of other channels. Entire system is designed on 3- by 4-inch printed-circuit cards and may be used with any pulse code modulation system.

Noda, T. T.↗

Automatic flowmeter calibration system

A system for automatically calibrating the accuracy of a flowmeter is described. The system includes a calculator capable of performing mathematical functions responsive to receiving data signals and function command signals. A prover cylinder is provided for measuring the temperature, pressure, and time required for accumulating a predetermined volume of fluid. Along with these signals, signals representing the temperature and pressure of the fluid going into the meter are fed to a plurality of data registers. Under control of a progress controller, the data registers are read out and the information is fed through a data select circuit to the calculator. Command signals are also produced by a function select circuit and are fed to the calculator set indicating the desired function to be performed. The reading is then compared with the reading produced by the flowmeter.

Lisle, R. V.↗

In-pixel automatic threshold calibration for the CMS Endcap Timing Layer readout chip

We present the implementation and verification of an in-pixel automatic threshold calibration circuit for the CMS Endcap Timing Layer (ETL) in the High-Luminosity LHC upgrade. The discriminator threshold of the ETL readout chip (ETROC) needs to be calibrated regularly to mitigate the circuit baseline change. Traditional methods need a lot of communication through a slow control system hence are time-consuming. This paper describes an in-pixel automatic scheme with improvements in operating time and usability. In this scheme, a sample-accumulation circuit is used to measure the average discriminator output. A binary successive approximation and linear combination scan are applied to find the equivalent baseline. The actual calibration procedure has been first implemented in FPGA firmware and tested with the ETROC front-end prototype chip (ETROC0). The calibration circuit has been implemented with Triple Modular Redundancy (TMR) and verified with Single Event Effects (SEEs) simulation. A complete calibration process lasts 35 ms with a 40 MHz clock. In the worst case, the dynamic and static power consumption are estimated to be 300 uW and 10.4 uW, respectively. The circuit design, implemented in a 65 CMOS technology, will be integrated into ETROC2, the next iteration of the ETROC with a 16 x16 pixel matrix.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Statistical Analysis of the 1995 Evaluation by NASA LaRC of the IAI Automatic Balance Calibration Machine

The NASA Langley Research Center (LARC) participated in a national cooperative evaluation of the Israel Aircraft Industries (IAI) automatic balance calibration machine at Microcraft, San Diego in September 1995. A LaRC-designed six-component strain gauge balance was selected for test and calibration during LaRC's scheduled evaluation period. Eight calibrations were conducted using three selected experimental designs. Raw data were exported to LaRC facilities for reduction and statistical analysis using the techniques outlined in Tripp and Tcheng (1994). This report presents preliminary assessments of the results, and compares IAI calibration results with manual calibration results obtained at the Modern Machine and Tool Co., Inc. (MM & T). Newport News, VA. A more comprehensive report is forthcoming.

Tcheng, Ping↗

Automatic force balance calibration system

A system for automatically calibrating force balances is provided. The invention uses a reference balance aligned with the balance being calibrated to provide superior accuracy while minimizing the time required to complete the calibration. The reference balance and the test balance are rigidly attached together with closely aligned moment centers. Loads placed on the system equally effect each balance, and the differences in the readings of the two balances can be used to generate the calibration matrix for the test balance. Since the accuracy of the test calibration is determined by the accuracy of the reference balance and current technology allows for reference balances to be calibrated to within +/-0.05% the entire system has an accuracy of +/-0.2%. The entire apparatus is relatively small and can be mounted on a movable base for easy transport between test locations. The system can also accept a wide variety of reference balances, thus allowing calibration under diverse load and size requirements.

Ferris, Alice T.↗

Automatic force balance calibration system

A system for automatically calibrating force balances is provided. The invention uses a reference balance aligned with the balance being calibrated to provide superior accuracy while minimizing the time required to complete the calibration. The reference balance and the test balance are rigidly attached together with closely aligned moment centers. Loads placed on the system equally effect each balance, and the differences in the readings of the two balances can be used to generate the calibration matrix for the test balance. Since the accuracy of the test calibration is determined by the accuracy of the reference balance and current technology allows for reference balances to be calibrated to within .+-.0.05%, the entire system has an accuracy of a .+-.0.2%. The entire apparatus is relatively small and can be mounted on a movable base for easy transport between test locations. The system can also accept a wide variety of reference balances, thus allowing calibration under diverse load and size requirements.

Ferris, Alice T.↗

A Comprehensive Calibration Framework for the Northwest River Forecast Center

We present a comprehensive framework developed by the Northwest River Forecast Center for calibrating hydrologically diverse basins. The framework includes models for snow, soil moisture, routing, channel loss, and consumptive use. Data inputs include a wide range of open-access datasets for meteorology, land use, topography, and land cover. The framework uses conceptual hydrologic models to handle basins with various hydrologic regimes including rain-driven and snowmelt-dominated basins. We also develop a flexible automatic calibration system that can handle numerous unobservable model parameters in a computationally efficient manner. A single-basin automatic calibration run can typically be completed on a modern laptop in under 10 min. We found that model performance metrics for this new approach match the quality of the NWRFC's previous labor-intensive manual calibrations. The model performance also rivals that of a state-of-the-art deep learning model at a fraction of the computational cost. This framework presents a new standard for the quality of calibrations possible with lumped conceptual hydrologic models, combining careful data curation, an objective calibration framework, and expert local knowledge. In addition, we have made software packages available for the entire suite of National Weather Service River Forecast System models, including SAC-SMA, SNOW-17, and Lag-K. These modern interfaces are intended to increase accessibility and facilitate future research.

Forecasting↗

Online Photometric Calibration of Automatic Gain Thermal Infrared Cameras

Thermal infrared cameras are increasingly being used in various applications such as robot vision, industrial inspection and medical imaging, thanks to their improved resolution and portability. However, the performance of traditional computer vision techniques developed for electro-optical imagery does not directly translate to the thermal domain due to two major reasons: these algorithms require photometric assumptions to hold, and methods for photometric calibration of RGB cameras cannot be applied to thermal-infrared cameras due to difference in data acquisition and sensor phenomenology. In this paper, we take a step in this direction, and introduce a novel algorithm for online photometric calibration of thermalinfrared cameras. Our proposed method does not require any specific driver/hardware support and hence can be applied to any commercial off-the-shelf thermal IR camera. We present this in the context of visual odometry and SLAM algorithms, and demonstrate the efficacy of our proposed system through extensive experiments for both standard benchmark datasets, and real-world field tests with a thermal-infrared camera in natural outdoor environments.

Daftry, Shreyansh↗