Search NASA⌕ Search

SEARCH · Search NASA

Results for “automatic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Distribution Substation Planning Toolkit (dsp-toolkit) v1.0

The Distribution Substation Planning Toolkit (DSP Toolkit) is a software suite designed to streamline the planning and optimization of distribution substations. This toolkit offers a comprehensive set of tools and APIs for data curation, short-term electric load forecasting, and weather-sensitive load adjustment, making it an essential resource for utility companies, engineers, and researchers. Features • Data Preprocessing and Curation: Efficiently manage and preprocess large datasets to ensure high-quality input for analysis. • Short-Term Load Forecasting: Utilize data-driven models to predict short-term electric loads accurately. • Weather-Sensitive Modeling: Automatically adjust load forecasts based on weather data to predict future peak demands more precisely. Uses The DSP Toolkit is ideal for planning and optimizing distribution substations, providing a user-friendly interface and comprehensive documentation. It is suitable for both novice and experienced users, facilitating efficient and accurate planning processes. Advantages • Efficiency: Automates complex planning tasks, reducing manual effort and minimizing errors. • Scalability: Handles large datasets and complex models, making it suitable for large-scale projects. • Community and Support: Open-source with active community contributions, ensuring continuous improvement and support. • Extensibility: Easily extendable with custom modules and plugins, allowing users to tailor the toolkit to their specific needs. The DSP Toolkit stands out by offering a robust, flexible, and user-friendly solution for distribution substation planning. Public Abstract

Li, Han [Lawrence Berkeley National Laboratory (LB↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

Plug load management system with load identification

The present disclosure relates to a plug load management system having automatic and dynamic load detection, meaning it has the ability to identify devices that are plugged into outlets of a building and determine the location of the plug load down to the specific outlet. When a device is moved, the plug load management system can determine this change and update accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic load balancing algorithm for molecular dynamics based on Voronoi cells domain decompositions

We present a new algorithm for automatic parallel load balancing in classical molecular dynamics. It assumes a spatial domain decomposition of particles into Voronoi cells. It is a gradient method which attempts to minimize a cost function by displacing Voronoi sites associated with each processor/sub-domain along steepest descent directions. Excellent load balance has been obtained for quasi-2D and 3D practical applications, with up to 440·10 6 particles on 65,536 MPI tasks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automatic Cloud Bursting under FermiCloud

Cloud computing is changing the infrastructure upon which scientific computing depends from supercomputers and distributed computing clusters to a more elastic cloud-based structure. The service-oriented focus and elasticity of clouds can not only facilitate technology needs of emerging business but also shorten response time and reduce operational costs of traditional scientific applications. Fermi National Accelerator Laboratory (Fermilab) is currently in the process of building its own private cloud, FermiCloud, which allows the existing grid infrastructure to use dynamically provisioned resources on FermiCloud to accommodate increased but dynamic computation demand from scientists in the domains of High Energy Physics (HEP) and other research areas. Cloud infrastructure also allows to increase a private cloud’s resource capacity through “bursting” by borrowing or renting resources from other community or commercial clouds when needed. This paper introduces a joint project on building a cloud federation to support HEP applications between Fermi National Accelerator Laboratory and Korea Institution of Science and Technology Information, with technical contributions from the Illinois Institute of Technology. In particular, this paper presents two recent accomplishments of the joint project: (a) cloud bursting automation and (b) load balancer. Automatic cloud bursting allows computer resources to be dynamically reconfigured to meet users’ demands. The load balance algorithm which the cloud bursting depends on decides when and where new resources need to be allocated. Our preliminary prototyping and experiments have shown promising success, yet, they also have opened new challenges to be studied

Wu, Hao↗

Bucket Loading Trajectory Optimization for the Automated Wheel Loader

The bucket motion of a wheel loader during the loading process is investigated in this study. The optimal bucket loading trajectory can be obtained by solving an optimal control problem with the performance criteria of the fill factor , fuel efficiency and operation cycle time . A control-oriented model for the bucket loading operation is developed. Based on the control-oriented model, the bucket loading process is formulated as an optimal control problem with physical constraints. An open-source optimization solver, OpenOCL, is used to solve this problem. The simulation results show that the proposed method is effective in generating the optimal trajectory with significantly increased energy efficiency and productivity. Furthermore, this optimal trajectory can be employed as a reference for an automated wheel loader or as a driver advisory for a human operated wheel loader.

42 ENGINEERING↗

The PhEDEx next-gen website

PhEDEx is the data-transfer management solution written by CMS. It consists of agents running at each site, a website for presentation of information, and a web-based data-service for scripted access to information. The website allows users to monitor the progress of data-transfers, the status of site agents and links between sites, and the overall status and behaviour of everything about PhEDEx. It also allows users to make and approve requests for data-transfers and for deletion of data. It is the main point-of-entry for all users wishing to interact with PhEDEx. For several years, the website has consisted of a single perl program with about 10K SLOC. This program has limited capabilities for exploring the data, with only coarse filtering capabilities and no context-sensitive awareness. Graphical information is presented as static images, generated on the server, with no interactivity. It is also not well connected to the rest of the PhEDEx codebase, since much of it was written before the data-service was developed. All this makes it hard to maintain and extend. We are re-implementing the website to address these issues. The UI is being rewritten in Javascript, replacing most of the server-side code. We are using the YUI toolkit to provide advanced features and context-sensitive interaction, and will adopt a Javascript charting library for generating graphical representations client-side. This relieves the server of much of its load, and automatically improves server-side security. The Javascript components can be re-used in many ways, allowing custom pages to be developed for specific uses. In particular, standalone test-cases using small numbers of components make it easier to debug the Javascript than it is to debug a large server program. Information about PhEDEx is accessed through the PhEDEx data-service, since direct SQL is not available from the clients browser. This provides consistent semantics with other, externally written monitoring tools, which already use the data-service. It also reduces redundancy in the code, yielding a simpler, consolidated codebase. In this talk we describe our experience of re-factoring this monolithic server-side program into a lighter client-side framework. We describe some of the techniques that worked well for us, and some of the mistakes we made along the way. We present the current state of the project, and its future direction.

Egeland, R.↗

Localized Fault Recovery for Nested Fork-Join Programs

Nested fork-join programs scheduled using work stealing can automatically balance load and adapt to changes in the execution environment. In this paper, we design an approach to efficiently recover from faults encountered by these programs. Specifically, we focus on localized recovery of the task space in the presence of fail-stop failures. We present an approach to efficiently track, under work stealing, the relationships between the work executed by various threads. This information is used to identify and schedule the tasks to be re-executed without interfering with normal task execution. The algorithm precisely computes the work lost, incurs minimal re-execution overhead, and can recover from an arbitrary number of failures. Experimental evaluation demonstrates low overheads in the absence of failures, recovery overheads on the same order as the lost work, and much lower recovery costs than alternative strategies.

Kestor, Gokcen↗

Distributed Resource Energy Analysis and Management System (DREAMS) Development for Real-time Grid Operations

This project supports development of the next generation, integrated energy management infrastructure (EMS) able to incorporate advance visualization of behind-the-meter distributed resource information and probabilistic renewable energy generation forecasts to inform real-time operational decisions. The project involves end-users and active feedback from an Utility Advisory Team (UAT) to help inform how information can be used to enhance operational functions (e.g. unit commitment, load forecasting, Automatic Generation Control (AGC) reserve monitoring, ramp alerts) within two major EMS platforms. Objectives include: Engaging utility operations personnel to develop user input on displays, set expectations, test and review; Developing ease of use and timeliness metrics for measuring enhancements; Developing prototype integrated capabilities within two operational EMS environments; Demonstrating an integrated decision analysis platform with real-time wind and solar forecasting information and timely distributed resource information; Seamlessly integrating new 4-dimensional information into operations without increasing workload and complexities; Developing sufficient analytics to inform and confidently transform and adopt new operating practices and procedures; Disseminating project lessons learned through industry sponsored workshops and conferences;Building on collaborative utility-vendor partnership and industry capabilities

14 SOLAR ENERGY↗

Development of Automation Technologies for Glovebox Processing, Part 2

Topics • Surplus Plutonium Disposition (SPD) Overview • Robotic Arm Development for Glovebox Operations • Automatic Sphincter Loading System (ASLS) Update Surplus Plutonium Disposition (SPD) Overview • Application Background • Development Scope • Improvement Goals • Limitations

Krementz, Daniel↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging Plug Load Management Technologies that Save Energy and Time

This fact sheet introduces two emerging technologies that could streamline plug load management (PLM) for increased energy savings for building owners: learning behavior algorithms (LBA) and automatic and dynamic load detection (ADLD). Plug loads are responsible for 47% of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them challenging to manage. PLM systems exist today that use smart plugs to meter and control devices at the outlet level, but their uptake has been relatively slow in part because of the significant labor required for installation and maintenance. LBA and ADLD may address these challenges and provide additional energy efficiency and nonenergy benefits.

Plug and process loads, PPL, plug loads, plug load↗

Microgrid Service Restoration Incorporating Unmonitored Automatic Voltage Controllers and Net Metered Loads

Islanded microgrids may experience voltage and frequency instability due to uncontrolled state changes of voltage regulation devices and inaccurate demand forecasts. Uncontrolled state changes can occur if optimal microgrid restoration and dispatch algorithms, used for generating control commands for distributed energy resources, do not incorporate the behavior of automatic controllers of voltage regulation devices. Inaccurate demand forecasts may be encountered since post-outage demand of behind-the-meter net metered (NM) loads can vary significantly from their historical NM profiles. Here, this paper proposes an optimization formulation which allows optimal control of voltage regulators and capacitor banks without remote control and communication capabilities. A generalized demand model for NM loads is proposed which incorporates the cold load pickup phenomenon and their time varying post-outage demand in accordance with the IEEE 1547 standard. The time dependent optimal control formulation and the NM demand model are integrated in a sequential microgrid restoration algorithm by linearization of the involved logic propositions. A detailed case study on the unbalanced IEEE 123-node test system in OpenDSS validates the effectiveness of the proposed approach.

30 DIRECT ENERGY CONVERSION↗

A meta-learning based distribution system load forecasting model selection framework

This paper presents a meta-learning based, automatic distribution system load forecasting model selection framework. Furthermore, the framework includes the following processes: feature extraction, candidate model preparation and labeling, offline training, and online model recommendation. Using load forecasting needs and data characteristics as input features, multiple metalearners are used to rank the candidate load forecast models based on their forecasting accuracy. Then, a scoring-voting mechanism is proposed to weights recommendations from each meta-leaner and make the final recommendations. Heterogeneous load forecasting tasks with different temporal and technical requirements at different load aggregation levels are set up to train, validate, and test the performance of the proposed framework. Simulation results demonstrate that the performance of the meta-learning based approach is satisfactory in both seen and unseen forecasting tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dissipativity-based design of local and wide-area DER controls for large-scale power systems with high penetration of renewables

In this paper, an integrated and modular control design is developed for distributed energy resources (DERs) to stabilize power systems and minimize effects of load variations and intermittent generation. Traditionally, the droop control of each generator (or virtual power plant) works as a local feedback loop to track frequency during load disturbance, whereas automatic generation control (AGC) calculates control signals and sends them to each generator with the goal of matching the total generation and load in the overall system. The droop control and the AGC work separately, therefore the two controls often conflict each other. The proposed design enables us to modularly synthesize an integrated control for each of the DERs by using both local and wide-area measurements so that the controls work together in enhancing stability and performance of the power system. The design methodology admits the full nonlinear power flow equations, and it results in a data-driven control that in real-time takes into account the nonlinear power flow interactions (in terms of current angle measurements) and adaptively adjusts parameters of the controls that operate the DERs. The design framework uses the concept of passivity-short systems to analyze individual DERs and quantify their dynamic responses in such a way that the resulting system-wide implementation becomes plug-and-play. Simulations are done to demonstrate the effectiveness of the proposed methodology and design.

Harvey, Roland↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗