Search NASA⌕ Search

SEARCH · Search NASA

Results for “back-illuminated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The infrared spectrograph during the SIRTF pre-definition phase

A test facility was set up to evaluate back-illuminated impurity band detectors constructed for an infrared spectrograph to be used on the Space Infrared Telescope Facility (SIRTF). Equipment built to perform the tests on these arrays is described. Initial tests have been geared toward determining dark current and read noise for the array. Four prior progress reports are incorporated into this report. They describe the first efforts in the detector development and testing effort; testing details and a new spectrograph concept; a discussion of resolution issues raised by the new design; management activities; a review of computer software and testing facility hardware; and a review of the preamplifier constructed as well as a revised schematic of the detector evaluation facility.

Houck, James R.↗

HII regions in IC 1613: The ISM in a nearby dwarf irregular galaxy

IC 1613, a nearby (725 kpc distant) dwarf irregular galaxy, has always been known to contain large, ring-shaped HII regions in its northeast corner. A new H alpha image has been obtained using the Bell Labs Charge Coupled Device (CCD) camera, an RCA 320 X 512 pixel-thinned, back-illuminated CCD, an H alpha filter of central wavelength 6562 A and width (full width half maximum) of 30 A, and the 42 inch telescope at Lowell Observatory. The low resolution images exhibit many new, faint features.

Price, Jill S.↗

Performance characteristics of STIS detectors

We report quantum efficiency measurements of back-illuminated, ion-implanted, laser-annealed charge coupled devices (CCD's) in the wavelength range 13-10,000 A. The equivalent quantum efficiency (EQE = effective photons detected per incident photon) ranges from a minimum of 5 percent as 1216 A to a maximum of 87 percent at 135 A. Using a simple relationship for the charge collection efficiency of the CCD pixels as a function of depth, we present a semi-empirical model with few parameters which reproduces our measurements with a fair degree of accuracy. The advantage of this model is that is can be used to predict CCD QE performance for shallow backside implanted devices without detailed solution of a system of differential equations, as in conventional approaches, and yields a simple analytic form for the charge collection efficiency which is adequate for detector calibration purposes. Making detailed assumptions about the dopant profile, we also solve the carrier density and continuity equations in order to relate our semi-empirical model parameters to surface and bulk device properties. The latter procedure helps to better establish device processing parameters for a given level of CCD QE performance.

Stern, Robert A.↗

High-performance visible/UV CCD focal plane technology for spacebased applications

We describe recent technology developments aimed at large CCD imagers for space based applications in the visible and UV. Some of the principal areas of effort include work on reducing device degradation in the natural space-radiation environment, improvements in quantum efficiency in the visible and UV, and larger-device formats. One of the most serious hazards for space based CCD's operating at low signal levels is the displacement damage resulting from bombardment by energetic protons. Such damage degrades charge-transfer efficiency and increases dark current. We have achieved improved hardness to proton-induced displacement damage by selective ion implants into the CCD channel and by reduced temperature of operation. To attain high quantum efficiency across the visible and UV we have developed a technology for back-illuminated CCD's. With suitable antireflection (AR) coatings such devices have quantum efficiencies near 90 percent in the 500-700-nm band. In the UV band from 200 to 400 nm, where it is difficult to find coatings that are sufficiently transparent and can provide good matching to the high refractive index of silicon, we have been able to substantially increase the quantum efficiency using a thin film of HfO2 as an AR coating. These technology efforts were applied to a 420 x 420-pixel frame-transfer imager, and future work will be extended to a 1024 x 1024-pixel device now under development.

Burke, B. E.↗

Solar-B X-ray Telescope (XRT) Concept Study Report

The X-ray observations from the Yohkoh SXT provided the greatest step forward in our understanding of the solar corona in nearly two decades. Expanding on the accomplishments of Yohkoh, we believe that the scientific objectives of the Solar-B mission are achieved with a significantly improved X-ray telescope (XRT) similar to the SXT. The Solar-B XRT will have twice the spatial resolution and a broader temperature response, while building on the knowledge gained from the successful Yohkoh mission. We present the scientific justification for this view, discuss the instrumental requirements that flow from the scientific objectives, and describe the instrumentation to meet these requirements. We then provide a detailed discussion of the design activities carried out during Phase A, noting the conclusions that were reached in terms of their implications for the detailed design activities which are now commencing. Details of the instrument that have changed as a result of the Phase A studied are specifically noted, and areas of concern going into Phase B are highlighted. XRT is a grazing-incidence (GI) modified Wolter I X-ray telescope, of 35cm inner diameter and 2.7m focal length. The 2048x2048 back-illuminated CCD (now an ISAS responsibility) has 13.5 micron pixels, corresponding to 1.0 arcsec and giving full Sun field of view. This will be the highest resolution GI X-ray telescope ever flown for Solar coronal studies, and it has been designed specifically to observe both the high and low temperature coronal plasma. A small optical telescope provides visible light images for co-alignment with the Solar-B optical and EUV instruments. The XRT science team is working in close cooperation with our Japanese colleagues in the design and construction of this instrument. All of the expertise and resources of the High Energy and Solar/Stellar Divisions of the Center for Astrophysics are being made available to this program, and our team will carry its full share of responsibility for mission operations, data reduction and education and public outreach. All aspects of the XRT design were reviewed during Phase A. The study focussed particularly on those aspects that have the greatest affect on instrument performance and extended lifetime, on the image quality error budget, and on the camera (mechanical and electrical) interface and the instrument mounting interfaces. The present instrument design differs in some details from that originally proposed. Selection of the XRT for Phase A study was contingent upon the removal of the camera and its associated electronics, and the acceptance of a stringent cost cap. The removal of the electronics left the XRT without control electronics for the instrument mechanisms. A mechanism controller was therefore added. The removal of the camera resulted in major complications to the integration and test plan. After many discussions, it was decided that the system would be less expensive, and the risk of unacceptable performance lower, if we include a focus mechanism. The remainder of the XRT design baseline matches the proposed configuration. Data requirements for the XRT are driven by the science plans, which are based on the physical processes in the solar outer atmosphere. Discussions to date of the XRT observing plan, both alone and in conjunction with the other Solar-B instruments, shows that the XRT needs 2 Gbits of on-board storage, at least one circulating buffer of 640 Mbits, and twelve 10- minute downlinks per day in order to carry out its required programs.

Golub, Leon↗

Observed On-Orbit Background of the ACIS Detector on the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic X-rays. The ACIS instrument contains 8 Front-Illuminated (FI) CCDs and 2 Back-Illuminated (BI) CCDs. The FI and BI CCD)s exhibit dramatically different responses to enhancements in the particle flux. The F1 CCDs show relatively little increase in the overall count rate, typical increases are 1 - 3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The duration of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the power-law. The events produce morphologies which are similar to cosmic X-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, P. P.↗

Radiation Environment of the Chandra X-Ray Observatory

The Chandra X-ray Observatory lies in a highly elliptical orbit which dips into the outer radiation belt. During the initial stages of orbital operations, Chandra's front-illuminated CCD's (but not the back-illuminated ones) experienced an unanticipated degradation of the charge-transfer efficiency. The subsequent anomaly investigation determined that moderately low-energy protons (or other ions) propagated through the mirror assembly, causing the observed damage. This paper summarizes the effort to determine the radiation environment at the Chandra focal plane and the steps taken to prevent further performance degradation by magnetospheric and solar-wind protons and other ions.

ODell, S. L.↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

Kepler Mission: End-to-End System Demonstration

A test facility has been constructed to demonstrate the capability of differential ensemble photometry to detect transits of Earth-size planets orbiting solar-like stars. The main objective is to determine the effects of various noise sources on the capability of a CCD photometer to maintain a system relative precision of 1 x $10^(-5)$ for mv = 12 stars in the presence of system-induced noise sources. The facility includes a simulated star field, fast optics to simulate the telescope, a thinned back-illuminated CCD similar to those to be used on the spacecraft and computers to perform the onboard control, data processing and extraction. The test structure is thermally and mechanically isolated so that each source of noise can be introduced in a controlled fashion and evaluated for its contribution to the total noise budget. The effects of pointing errors or a changing thermal environment are imposed by piezo-electric devices. Transits are injected by heating small wires crossing apertures in the star plate. Signals as small as those from terrestrial-size transits of solar-like stars are introduced to demonstrate that such planets can be detected under realistic noise conditions. Examples of imposing several noise sources and the resulting detectabilities are presented. These show that a differential ensemble photometric approach CCD photometer can readily detect signals associated with Earth-size transits.

Borucki, William↗

Managing Radiation Degradation of CCDs on the Chandra X-ray Observatory

The CCDs on the Chandra X ray Observatory are sensitive to radiation damage particularly from low-energy protons scattering off the telescope's mirrors onto the focal plane. In its highly elliptical orbit, Chandra passes through a spatially and temporally varying radiation environment, ranging from the radiation belts to the solar wind. Translating thc Advanced CCD Imaging Spectrometer (ACIS) out of the focal position during radiation-belt passages has prevented loss of scientific utility and eventually functionality. However, carefully managing the radiation damage during the remainder of the orbit, without unnecessarily sacrificing observing time, is essential to optimizing the scientific value of this exceptional observatory throughout its planned 10-year mission. In working toward this optimization, the Chandra team developed aid applied radiation-management strategies. These strategies include autonomous instrument safing triggered by the on-board radiation monitor, as well as monitoring, alerts, and intervention based upon real-time space-environment data from NOAA and NASA spacecraft. Furthermore, because Chandra often spends much of its orbit out of the solar wind (in the Earth's outer magnetosphere and magnetosheath), the team developed the Chandra Radiation Model to describe the complete low-energy-proton environment. Management of the radiation damage has thus far succeeded in limiting degradation of the charge-transfer inefficiency (CTI) to less than 4.4*10^-6 and 1.4*10^-6 per year for the front-illuminated and back-illuminated CCDs, respectively.

ODell, Stephen L.↗

A Program to Detect and Characterize Extra-Solar Giant Planets

We initiated a significant hardware upgrade to the AFOE, to increase its efficiency for precise radial velocity studies to the level where we can continue to contribute usefully to extrasolar planet research on relatively bright stars. The AFOE, at a 1.5-m telescope, will of course not have the sensitivity of radial velocity instruments at larger telescopes, such as the HIRES on Keck or the Hectochelle on the MMT telescope (about to come on line). However, it has been possible to increase its efficiency for precise radial velocity studies by a factor of 4 to 5, which-combined with the large amount of telescope time available at the 1.5-m telescope-will permit us to do intensive follow-up observations of stars brighter than about 8 magnitude. The AFOE was originally designed primarily for asteroseismology using a ThAr reference. This provided useful wavelength stability over tens of minutes as required for asteroseismology, but we were unable to get a long-term (month-to-month) velocity precision better than about 15 m/s with that setup. Hence, we implemented an iodine cell as a wavelength reference for extrasolar planet studies. However, the optical design of the original AFOE did not completely span the wavelength range covered by the iodine absorption spectrum, and furthermore the optics suffered significant light loss through optical obscuration in the camera secondary. To remedy this, we replaced the AFOE grating with a new one that covered the entire iodine spectral range at somewhat lower spectral resolution, and replaced the camera with a transmitting lens. (The use of a lens was made possible by restricting the spectral range covered by the upgraded AFOE to only the iodine region.) These upgrades were successfully completed, and the instrument was tested for three nights in fall of 2002. The expected improvement in sensitivity by a factor of 4 to 5 was observed: that is, the same velocity precision as previously attained (of order 5 to 7 m/s) was now obtained on a stars that are about 4 to 5 times fainter. Unfortunately, just after installing the new AFOE optics, there was a catastrophic failure of the old Tektronix CCD. A careful investigation was made, and it was determined that the failure was probably due to too many thermal cyclings over the previous 8 years. The only solution was to purchase a new CCD. Internal funds of $16,000 were found for this purpose, and the new CCD (a thinned, back-illuminated Marconi 2K x 2K device with 13.5 micron pixels, and employing dual readout channels to keep the readout time as short as 20 seconds) was ordered, has now arrived, and is currently under test before 1 being installed in the AFOE liquid nitrogen dewar. At the same time, we expect to implement new CCD control electronics. This system should be better in many ways than the previous detector (including eliminating the need for UV flashing to maximize the quantum efficiency). We plan to install the detector on the telescope and begin operations again in April of this year.

Lindstrom, David↗

Modeling of Proton-Induced CCD Degradation in the Chandra X-Ray Observatory

Modeling results are presented for proton-induced degradation of charge-coupled devices (CCDs) used in the Advanced CCD Imaging Spectrometer instrument on the Chandra X-Ray Observatory. A methodology is described that provides insights regarding degradation mechanism and on-orbit performance for front-illuminated and back-illuminated CCDs Proton-induced changes in charge transfer inefficiency are modeled. The observed amount of on-orbit degradation can be accounted for using a proton spectrum at the CCD location that is reduced in magnitude by a factor of approx. 1E5 compared to the spectrum incident on the spacecraft.

Lo, D. H.↗

A Program to Detect and Characterize Extra-Solar Giant Planets

The upgrade to the AFOE spectrograph at the 1.5-m Tillinghast telescope at FLWO Observatory, described in detail in the previous progress report, was completed. Work included installing a new CCD detector (using SA0 internal funds) to replace the previous detector, which had failed after many thermal cyclings during the previous nearly ten years of operation. The new detector (a back-illuminated Marconi 2K x 2K detector) shows excellent quantum efficiency, and employs dual readout channels to keep the readout time as short as 20 seconds. Tests of the attainable radial velocity precision of the upgraded spectrograph with the new detector show an improvement in radial velocity detection efficiency by a factor of about 10 over the previous AFOE configuration, allowing us to push the photon-noise-limited doppler precision of 7 m/s to correspondingly fainter stars. This work was carried out by Co-investigator Sylvain Korzennik, along with the late Peter Nisenson.

Lindstrim, David↗

Managing radiation degradation of CCDs on the Chandra X-ray Observatory II

The CCDs on the Chandra X-ray Observatory are vulnerable to radiation damage from low-energy protons scattered off the telescope's mirrors onto the focal plane. Following unexpected damage incurred early in the mission, the Chandra Team developed, implemented, and maintains a radiation-protection program. This program - involving scheduled radiation safing during radiation-belt passes, intervention based upon real-time space-weather conditions and radiation-environment modeling, and on-board radiation monitoring with autonomous radiation safing - has successfully managed the radiation damage to the CCDs. Since implementing the program, the charge-transfer inefficiency (CTI) has increased at an average annual rate of only 2.9x10^-6 (2.3%) for the front- illuminated CCDs and 0.95x10^-6 (6.5%) for the back-illuminated CCDs. This paper describes the current status of Chandra radiation-management program.

O'Dell, Stephen L.↗

Ultra-Low-Temperature Homoepitaxial Growth of Sb-Doped Silicon

An ultra-low-temperature process for homoepitaxial growth of high-quality, surface-confined, Sb-doped silicon layers is presented. Non-equilibrium growth by molecular beam epitaxy (MBE) is used to achieve dopant incorporation in excess of 2x10(exp 14) per sq cm in a thin, surface-confined layer. Sb surface segregation larger than expected from theoretical models was observed, in agreement with other experimental works. Furthermore, this work details an entirely low-temperature process (less than 450 degree C) that can be applied to fully processed and aluminum-metallized silicon devices. One application of this process is the formation of a back-surface electrode for back-illuminated high-purity silicon imaging arrays.

Molecular beam epitaxy↗

Dual-Pump Coherent Anti-Stokes Raman Scattering Temperature and CO2 Concentration Measurements

Measurements of temperature and CO2 concentration using dual-pump coherent anti-Stokes Raman scattering, (CARS) are described. The measurements were performed in laboratory flames,in a room-temperature gas cell, and on an engine test stand at the U.S. Air Force Research Laboratory, Wright-Patterson Air Force Base. A modeless dye laser, a single-mode Nd:YAG laser, and an unintensified back-illuminated charge-coupled device digital camera were used for these measurements. The CARS measurements were performed on a single-laser-shot basis. The standard deviations of the temperatures and CO2 mole fractions determined from single-shot dual-pump CARS spectra in steady laminar propane/air flames were approximately 2 and 10% of the mean values of approximately 2000 K and 0.10, respectively. The precision and accuracy of single-shot temperature measurements obtained from the nitrogen part of the dual-pump CARS system were investigated in detail in near-adiabatic hydrogen/air/CO2 flames. The precision of the CARS temperature measurements was found to be comparable to the best results reported in the literature for conventional two-laser, single-pump CARS. The application of dual-pump CARS for single-shot measurements in a swirl-stabilized combustor fueled with JP-8 was also demonstrated.

Lucht, Robert P.↗

NASA Tech Briefs, October 2003

Topics covered include: Cryogenic Temperature-Gradient Foam/Substrate Tensile Tester; Flight Test of an Intelligent Flight-Control System; Slat Heater Boxes for Thermal Vacuum Testing; System for Testing Thermal Insulation of Pipes; Electrical-Impedance-Based Ice-Thickness Gauges; Simulation System for Training in Laparoscopic Surgery; Flasher Powered by Photovoltaic Cells and Ultracapacitors; Improved Autoassociative Neural Networks; Toroidal-Core Microinductors Biased by Permanent Magnets; Using Correlated Photons to Suppress Background Noise; Atmospheric-Fade-Tolerant Tracking and Pointing in Wireless Optical Communication; Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors; Software for Displaying Data from Planetary Rovers; Software for Refining or Coarsening Computational Grids; Software for Diagnosis of Multiple Coordinated Spacecraft; Software Helps Retrieve Information Relevant to the User; Software for Simulating a Complex Robot; Software for Planning Scientific Activities on Mars; Software for Training in Pre-College Mathematics; Switching and Rectification in Carbon-Nanotube Junctions; Scandia-and-Yttria-Stabilized Zirconia for Thermal Barriers; Environmentally Safer, Less Toxic Fire-Extinguishing Agents; Multiaxial Temperature- and Time-Dependent Failure Model; Cloverleaf Vibratory Microgyroscope with Integrated Post; Single-Vector Calibration of Wind-Tunnel Force Balances; Microgyroscope with Vibrating Post as Rotation Transducer; Continuous Tuning and Calibration of Vibratory Gyroscopes; Compact, Pneumatically Actuated Filter Shuttle; Improved Bearingless Switched-Reluctance Motor; Fluorescent Quantum Dots for Biological Labeling; Growing Three-Dimensional Corneal Tissue in a Bioreactor; Scanning Tunneling Optical Resonance Microscopy; The Micro-Arcsecond Metrology Testbed; Detecting Moving Targets by Use of Soliton Resonances; and Finite-Element Methods for Real-Time Simulation of Surgery.

Source record↗