Search NASA⌕ Search

SEARCH · Search NASA

Results for “background software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simulating Alpha Particles Incident on MKID Chips for Quantum Sensitivity Analysis

Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.

Hall, Matthew [Fermilab; UCLA]↗

NuGraph2: A Graph Neural Network for Neutrino Event Reconstruction

Neutrino experiments are set to probe some of the most important open questions in physics, from CP violation and the nature of dark matter. The technology of choice for many of these experiments is the liquid argon time projection chamber (LArTPC). In current LArTPC experiments, reconstruction performance often represents a limiting factor for the sensitivity. New developments are therefore needed to unlock the full potential of LArTPC experiments. NuGraph2 is a state of the art Graph Neural Network for reconstruction of data in LArTPC experiments. NuGraph2 utilizes a heterogeneous graph structure, with separate subgraphs of 2D nodes (hits in each plane) connected across planes via 3D nodes (space points). The model provides a consistent description of the neutrino interaction across all planes. NuGraph2 is a multi-purpose network, with a common message-passing attention engine connected to multiple decoders with different classification or regression tasks. These include the classification of detector hits according to the particle type that produced them (semantic segmentation) and the separation of hits from the neutrino interaction from hits due to noise or cosmic-ray background. Additional decoders are being developed, performing tasks such as the regression of the neutrino interaction vertex position. Performance results will be presented based on publicly available samples from MicroBooNE. These include both physics performance metrics, achieving 95% accuracy for semantic segmentation and 98% classification of neutrino hits, as well as computational metrics for training and for inference on CPU or GPU. The status of the NuGraph integration in the LArSoft software framework will be presented, as well as initial studies about model interpretability and injection of domain knowledge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CalderaCast User Manual Version 1.0

CalderaCast is a user-friendly web-based tool for electrical-load forecast, providing stakeholders with a fully customizable decision-support framework that estimates the likely power draw from a possible future electric-vehicle (EV) charging station at a given location on a given day along an alternative fuel corridor (AFC). These EV charging profiles are accurately modeled in CalderaCast using the Caldera software framework developed by Idaho National Laboratories (INL), reflecting the realistic charging levels observed in actual charge events. This tool was developed as part of the National Electric Vehicle Infrastructure (NEVI) program, which is quickly generating substantial interest from would-be charging station operators (CSO), large and small electric utilities, and state transportation planners, some of whom had not seriously considered EV charging previously. All these entities—with or without background in EV infrastructure—must estimate the electricity load that a proposed charging station will generate. This load forecast is critically important for a utility to properly assess the capacity of their distribution network to support the proposed station or properly size grid upgrades for potential load growth due to future EV adoption, vehicle technology improvements, or station growth. This document describes each aspect of the CalderaCast tool and provides guidance to users who are interested in utilizing the tool for their work.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

NuGraph2: A Graph Neural Network for Neutrino Event Reconstruction

Neutrino experiments are set to probe some of the most important open questions in physics, from CP violation and the nature of dark matter. The technology of choice for many of these experiments is the liquid argon time projection chamber (LArTPC). In current LArTPC experiments, reconstruction performance often represents a limiting factor for the sensitivity. New developments are therefore needed to unlock the full potential of LArTPC experiments. NuGraph2 is a state of the art Graph Neural Network for reconstruction of data in LArTPC experiments. NuGraph2 utilizes a heterogeneous graph structure, with separate subgraphs of 2D nodes (hits in each plane) connected across planes via 3D nodes (space points). The model provides a consistent description of the neutrino interaction across all planes. NuGraph2 is a multi-purpose network, with a common message-passing attention engine connected to multiple decoders with different classification or regression tasks. These include the classification of detector hits according to the particle type that produced them (semantic segmentation) and the separation of hits from the neutrino interaction from hits due to noise or cosmic-ray background. Additional decoders are being developed, performing tasks such as the regression of the neutrino interaction vertex position. Performance results will be presented based on publicly available samples from MicroBooNE. These include both physics performance metrics, achieving 95% accuracy for semantic segmentation and 98% classification of neutrino hits, as well as computational metrics for training and for inference on CPU or GPU. The status of the NuGraph integration in the LArSoft software framework will be presented, as well as initial studies about model interpretability and injection of domain knowledge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NuGraph2: A Graph Neural Network for Neutrino Event Reconstruction

Neutrino experiments are set to probe some of the most important open questions in physics, from CP violation and the nature of dark matter. The technology of choice for many of these experiments is the liquid argon time projection chamber (LArTPC). In current LArTPC experiments, reconstruction performance often represents a limiting factor for the sensitivity. New developments are therefore needed to unlock the full potential of LArTPC experiments. NuGraph2 is a state of the art Graph Neural Network for reconstruction of data in LArTPC experiments [https://arxiv.org/abs/2403.11872]. NuGraph2 utilizes a heterogeneous graph structure, with separate subgraphs of 2D nodes (hits in each plane) connected across planes via 3D nodes (space points). The model provides a consistent description of the neutrino interaction across all planes. NuGraph2 is a multi-purpose network, with a common message-passing attention engine connected to multiple decoders with different classification or regression tasks. These include the classification of detector hits according to the particle type that produced them (semantic segmentation) and the separation of hits from the neutrino interaction from hits due to noise or cosmic-ray background. Additional decoders are being developed, performing tasks such as the regression of the neutrino interaction vertex position. Performance results will be presented based on publicly available samples from MicroBooNE. These include both physics performance metrics, achieving 95% accuracy for semantic segmentation and 98% classification of neutrino hits, as well as computational metrics for training and for inference on CPU or GPU. The status of the NuGraph integration in the LArSoft software framework will be presented, as well as initial studies about model interpretability and injection of domain knowledge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an↗

Commissioning of the Mu2e tracker DAQ, planning for the Vertical Slice Test and pre-pattern recognition studies

The primary objective of the Mu2e experiment at Fermilab is to search for the neutrino-less coherent $\mu \rightarrow e$ conversion in the field of an aluminum nucleus ($\mu^- \text{Al} \rightarrow e^- \text{Al}$). The signature of this process is a monochromatic Conversion Electron (CE) with an energy of approximately 104.97 MeV \cite{bartoszek2015mu2e}. Within the Standard Model (SM), the branching ratio for this process, including neutrino masses and oscillation, is expected to be less than $\mathcal{O}(10^{-50})$. This value is far beyond current experimental capabilities. However, models of physics beyond the SM predict much higher relative rates, approaching an observable level. The SINDRUM II experiment set an upper limit on muon conversion at $7 \times 10^{-13}$ (90\% CL) on Au target \cite{SINDRUMII:2006dvw}, and the Mu2e collaboration aims to improve this limit by four orders of magnitude. Observing this process would provide a clear evidence of physics beyond the Standard Model. A brief discussion of the theoretical and experimental aspects is provided in Chapter \ref{intr}. Mu2e adopts a sophisticated experimental setup to achieve its goals, further described in Chapter \ref{mu2echapter}. The central part of the Mu2e detector is the tracker, that consists of 18 tracking stations. The tracker must provide excellent momentum resolution, approximately 1 MeV/c, to distinguish the monochromatic CE signal from the background. To minimize the energy losses, a straw tube tracker will be used \cite{bobbb}. Chapter \ref{chaptertrk} provides an overview of the straw tracker design and its working principles. This Thesis presents a comprehensive study of the Mu2e tracker, covering complementary aspects from initial commissioning to optimization and first steps of the calibration processes. My work at Fermilab has been focused on the complete Data Acquisition (DAQ) testing from both hardware and software perspectives. I was involved in the commissioning of the Mu2e DAQ system and the Vertical Slice Test (VST) of the tracker. The VST encompasses the entire testing chain, from the straws to the readout, and to processed data on disk. I was also focused on the offline analysis, especially on pre-pattern recognition studies, to explore the best methods for identifying $\delta$-electrons during the data taking. Chapter \ref{commissioning} details the commissioning of the tracker DAQ system, emphasizing the importance of understanding of the readout process before the data acquisition. This includes validating the readout logic and firmware through Monte Carlo simulations to confirm functionality and buffering, monitoring the quality of the data from the tracker preamplifiers and front-end electronics, and assessing overall DAQ performance to ensure reliability during future calibration and data-taking. Chapter \ref{planning} discusses the initial steps towards the tracker calibration. The ultimate goal is to perform a time calibration of the first assembled station of the tracker using cosmic muons, aiming for a longitudinal hit position resolution better than 4 cm. This involves determining the signal propagation times and channel-to-channel delays. I performed a Monte Carlo study to determine the impact of the station orientation on the quality of the calibration, in particular on the cosmic track reconstruction, focusing on potential biases that could arise. These studies provide essential insights into the operation, optimization, and calibration of the Mu2e tracker system. Given the high data volume expected during Mu2e operations, estimated at approximately 7 PBytes per year, optimizing memory usage and minimizing CPU consumption are critical. A significant challenge lies in effectively flagging $\delta$-electron hits, which are the primary source of hits in the tracker, without compromising the efficiency of CE hit detection and track reconstruction. A detailed study of pre-pattern recognition and a thorough comparison of two $\delta$-electron flagging algorithms is provided in Chapter \ref{delta}. In Chapter \ref{conclusions}, the findings are concisely summarized, offering a comprehensive synthesis of the research and emphasizing the key insights derived from this study.

43 PARTICLE ACCELERATORS↗

Full-sky Models of Galactic Microwave Emission and Polarization at Subarcminute Scales for the Python Sky Model

Polarized foreground emission from the Galaxy is one of the biggest challenges facing current and upcoming cosmic microwave background (CMB) polarization experiments. We develop new models of polarized Galactic dust and synchrotron emission at CMB frequencies that draw on the latest observational constraints; that employ the “polarization fraction tensor” framework to couple intensity and polarization in a physically motivated way; and that allow for stochastic realizations of small-scale structure at subarcminute angular scales currently unconstrained by full-sky data. We implement these models into the publicly available Python Sky Model (PySM) software and additionally provide PySM interfaces to select models of dust and CO emission from the literature. We characterize the behavior of each model by quantitatively comparing it to observational constraints in both maps and power spectra, demonstrating an overall improvement over previous PySM models. Finally, we synthesize models of the various Galactic foreground components into a coherent suite of three plausible microwave skies that span a range of astrophysical complexity allowed by current data. Author contributions to this paper can be found at the end of this work.

Group, The Pan-Experiment Galactic Science↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

User Guide for BLADE_LC_processor.py

BLADE_LC_processor.py is an optional script within the BLADE (Bolide Light-curve Analysis and Discrimination Explorer) open-source software package. It converts per-event light curve CSVs plus a metadata table into maps, plots, a per-sample trajectory file, and an aggregate summary. It anchors each trajectory at peak brightness, assumes constant speed and entry angle across the event, and propagates altitude and ground track relative to that anchor. The script converts the input azimuth internally to a travel bearing for the map and trajectory. Outputs include event folders with figures and a consolidated CSV containing start, peak, and end altitudes and all original metadata, sorted newest to oldest. For further background, users are referred to the foundational publication: Silber, E. A., Sawal, V. (2025), “BLADE: An Automated Framework for Classifying Light Curves from the Center for Near-Earth Object Studies Fireball Database,” The Astronomical Journal, doi: 10.3847/1538-3881/adeb55.

97 MATHEMATICS AND COMPUTING↗

time-resolved spectroscopy fit (trspecfit) v0.01

Analyze 2D time- and energy-resolved data, such as from a pump-probe spectroscopy experiment. User can select and input different peak shapes/ functions and background types to first fit a ground state/ unperturbed spectrum. This would be similar to how standard spectroscopy data is fit. Subsequently, to describe the time domain, users can choose functions that describe the temporal dynamics of one or more spectral features, such as a peak amplitude, peak position, etc. These time dynamics functions can be added or convoluted (e.g. describing an instrument response function) with each other. Functionality to integrate implicit variables leading to distributions of certain parameters/ functions is in development. Alternatively, 2D data can be analyzed one time step at a time to get an idea of the time dynamics of the system before deploying the global 2D fit described above. Typically people write custom software for this purpose. During my PhD I've seen five internal LBL and external researchers write one-off code in different languages to analyze time- and energy-resolved spectra. While this was specifically was for a laser pump - X-ray probe spectroscopy experiment, I'm trying to write a general package for the time-resolved spectroscopy community.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Periodicity significance testing with null-signal templates: reassessment of PTF’s SMBH binary candidates

Periodograms are widely employed for identifying periodicity in time series data, yet they often struggle to accurately quantify the statistical significance of detected periodic signals when the data complexity precludes reliable simulations. We develop a data-driven approach to address this challenge by introducing a null-signal template (NST). The NST is created by carefully randomizing the period of each cycle in the periodogram template, rendering it non-periodic. It has the same frequentist properties as a periodic signal template, and we show with simulations that the distribution of false positives is the same as with the original periodic template, regardless of the underlying data. Thus, performing a periodicity search with the NST acts as an effective simulation of the null (no-signal) hypothesis, without having to simulate the noise properties of the data. We apply the NST method to the supermassive black hole binaries (SMBHB) search in the Palomar Transient Factory (PTF), where Charisi et al. had previously proposed 33 high signal-to-noise candidates utilizing simulations to quantify their significance. Our approach reveals that these simulations do not capture the complexity of the real data. There are no statistically significant periodic signal detections above the non-periodic background. To improve the search sensitivity, we introduce a Gaussian quadrature based algorithm for the Bayes Factor with correlated noise as a test statistic. We show with simulations that this improves sensitivity to true signals by more than an order of magnitude. However, the Bayes Factor approach also results in no statistically significant detections in the PTF data.

79 ASTRONOMY AND ASTROPHYSICS↗

Deriving Stable Peak Models to Fit Complex XPS Data From Cu Contaminated Pt Electrocatalysts

X-ray Photoelectron Spectroscopy spectra peak models, designed to partition photoemission signals emanating from different elements or chemical states within an atom, are fitted to data limited to an energy interval over which inelastically scattered photoemission signal can be estimated. While the choice of background approximation and line shapes of components to the peak model requires careful consideration, the energy interval used to define the data to which the peak model is optimized has a significant impact on the final peak model. The relationship between the background intensity and data intensity at the start and end of the energy interval dictates the line shapes used in the peak model. In this work, we devise a method to peak fit a complex overlapping Cu 3p and Pt 4f XPS peak structure to perform the elemental quantification. We first use an Al 2s peak to illustrate how background curves approach data at the limits of the energy interval over which the background is defined, influencing the analysis of XPS spectra. Next, we demonstrate the nature of interactions between specific line shapes (Voigt and pseudo-Voigt profiles) suitable for photoemission peaks and a specific background curve (Shirley) and a peak model is presented that includes components to the peak model that accommodates background intensity during fitting of the peak model to data. The peak model allowed for quantification of the contributions of Pt 4f peaks emanating from the substrate that exhibits strong asymmetry in the presence of the inhomogeneously distributed Cu species, mostly of Lorentzian character.

XPS↗

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean↗

Stereo-DIC Challenge 1.0 – Rigid Body Motion of a Complex Shape

Background Stereo-DIC is a widely used optical measurement technique that provides a dense full-field 3D measurement of the shape, displacement, and strain of a solid sample. When compared with 2D-DIC, Stereo-DIC provides greater flexibility and expands its use beyond flat, planar specimens. Furthermore, the widespread availability of commercial systems has led to the adoption of the technique throughout industry, academia, and government research labs. Objective Even though some research has been done to understand the effects of different experimental and stereo-DIC parameters, no reference is available to benchmark and compare the performance of current stereo-DIC algorithms to each other. Methods This paper provides the description and analysis of a carefully controlled 3D experiment and associated images used to compare the results from five subset based DIC software packages. Both the images and analysis codes used in this paper to compare the results are described here and are available for download and use for continued research. Results We show that over a very large range of motion, the 3D errors are very small, less than 80μm over a travel of ±20 mm out-of-plane and ±20 mm in-plane. While all codes performed similarly, there are important differences noted in the paper. Conclusion The image sets and results comparison software are hosted by the International DIC Society (www.iDICs.org) and are freely available for download and analysis for comparison with results in this paper. Furthermore, it is hoped that this set of images can be used for future research in improving stereo-DIC by future authors.

Algorithms comparison↗

PROTOCALC, a W -band Polarized Calibrator for Cosmic Microwave Background Telescopes: Application to Simons Observatory and CLASS

Current- and next-generation cosmic microwave background (CMB) experiments will measure polarization anisotropies with unprecedented sensitivities. The need for high precision in these measurements underscores the importance of gaining a comprehensive understanding of instrument properties, with a particular emphasis on the study of the beam properties, and especially their polarization characteristics and the measurement of the polarization angle. In this context, a major challenge lies in the scarcity of millimeter polarized astrophysical sources with sufficient brightness and calibration knowledge to meet the stringent accuracy requirements of future CMB missions. This led to the development of a drone-borne calibration source designed for the frequency band centered on approximately 90 GHz, matching a commonly used channel in ground-based CMB measurements. The Prototype Calibrator for Cosmology, PROTOCALC, has undergone thorough in-lab testing, and its properties have been subsequently modeled through simulation software integrated into the standard Simons Observatory analysis pipeline. Moreover, the PROTOCALC system has been tested in the field, having been deployed twice on calibration campaigns with CMB telescopes in the Atacama Desert. The data collected constrain the roll angle of the source with a statistical accuracy of 0$^°_•$045.

79 ASTRONOMY AND ASTROPHYSICS↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗

Frequency-Selectable Laser Source for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M. [Fermilab]↗