At least 37 records · Page 2

Piezo-Operated Shutter Mechanism Moves 1.5 cm

The figure shows parts of a shutter mechanism designed to satisfy a number of requirements specific to its original intended application as a component of an atomic clock to be flown in outer space. The mechanism may also be suitable for use in laboratory and industrial vacuum systems on Earth for which there are similar requirements. The requirements include the following: a) To alternately close, then open, a 1.5-cm-diameter optical aperture twice per second, with a stroke time of no more than 15 ms, during a total operational lifetime of at least a year; b) To attenuate light by a factor of at least 1012 when in the closed position; c) To generate little or no magnetic field; d) To be capable of withstanding bakeout at a temperature of 200 C to minimize outgassing during subsequent operation in an ultrahigh vacuum; and e) To fit within a diameter of 12 in. (=305 mm) a size limit dictated by the size of an associated magnetic shield. The light-attenuation requirement is satisfied by use of overlapping shutter blades. The closure of the aperture involves, among other things, insertion of a single shutter blade between a pair of shutter blades. The requirement to minimize the magnetic field is satisfied by use of piezoelectric actuators. Because piezoelectric actuators cannot withstand bakeout, they must be mounted outside the vacuum chamber, and, hence, motion must be transmitted from the actuators to the shutter levers via a vacuum-chamber-wall diaphragm.

Glaser, Robert↗

Space Environmental Effects on Additively Manufactured (AM) Parts on MISSE-9/10

The Materials on International Space Station Experiment (MISSE) experiments have made a continuous presence on the ISS and allowed for testing of performance and durability of materials exposed to the Low Earth Orbit (LEO) space environment. Additive Manufacturing (AM) has been included on several MISSE flights, and many companies (Made in Space and Stratasys) and NASA centers wanted to test various AM material samples. The goal of studying Space Environmental Effects on AM Parts with MISSE 9/10 was to fly promising metal and polymer AM material samples (dogbones) that could have future manufacturing capabilities in space and conduct post-flight analysis of these materials via mechanical and optical properties. On these flights, MISSE-9 contained three Inconel and 12 polymer samples and MISSE-10 included three Inconel and 16 polymer samples. Before flying to the ISS, all the samples underwent thermal vacuum bakeout (at 60°C for 24 hours and 10-6 torr). After bakeout, control and flight experiments were weighed, and optical properties were taken. Optical properties such as solar absorptance and infrared emittance were taken on the control samples and the flight samples (preflight and postflight). To understand more about the mechanical properties of the AM samples, tensile testing was conducted on the samples to determine the yield and ultimate tensile strength of the dogbone samples against the control. Lastly, the torque on the fasteners securing the dogbone samples were loosened and measured using a torque wrench, and they were compared to their preflight torque specification required. Optical properties and masses were recorded before flight, and the postflight results were recorded and collected in June 2022 to study the effects. With the postflight analysis, NASA engineers can now better characterize how UV radiation and thermal cycling affect the material properties.

Materials on International Space Station Experimen↗

Water and Ammonia Desorption from 5A Zeolite

Demonstrate adsorption and desorption characteristics of water and ammonia on 5A zeolite during regeneration conditions using a Thermogravimetric analyzer (TGA) on samples previously evaluated by residual gas analyzer (RGA)/mass balance. Molecular sieve (zeolite) adsorbents have the following characteristics: Crystalline alumino-silicates containing pores or 'cages' that adsorb water or other molecules. Polar compound are adsorbed with high loading even at very low concentrations of the fluid. A 5A molecular sieve was chosen for its ability to adsorb both water and ammonia (NH{sub 3}) from a carrier gas stream. Preliminary RGA/mass balance testing indicated: 5A zeolite captured both NH{sub 3} and water as anticipated based on molecular size; Reloading showed limited success after zeolite heated beyond manufacturer recommended operating conditions: Steam dealumination theorized cause; Tests were reprioritized to focus on NH{sub 3} removal and end of life potential holdup of NH{sub 3} and water on 5A zeolite material. TGA measures a sample's weight and volatile composition as it is heated or cooled in a furnace. TGA heats sample to release volatile materials, (change in mass is measured). MS detects/measures low levels of impurities. Perform TGA desorption of zeolite samples taken at the following conditions tested with RGA (RGA results not shown here): Initial Bakeout conditions: hydrogen carrier gas, slowly raise temp to approximately 300 deg. C until desired moisture content <<100 ppm is achieved. Water loading (re-loading): argon carrier gas through bubbler until breach is observed. Ammonia loading (re-loading): hydrogen carrier gas through system. Regenerations/End of life conditions: hydrogen carrier gas, raise temp to approximately 300 deg. C, then slowly to 450 deg. C (end of life). After end of life testing less than 4% of the total mass was residual ammonia or water at bakeout conditions. Peak water and ammonia removal occurred around 275 deg. C and 150 deg. C respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IOTA Pre-Bake Test Development

The IOTA (Integrable Optics Test Accelerator) Bakeout project is intended to improve the quality of the vacuum within the IOTA ring. Impurities consisting of hydrogen and oxygen that build within the beampipe are reduced through applying heat to the beampipe’s exterior. Two versions of the Bakeout project exist, one as a smaller scale test setup, and one five times larger located within the IOTA ring. During my internship, I worked together with a team to bring this project from an effectively dormant state to ready for testing, working together to create full documentation of the PLC (Programmable Logic Controller) programs, making multiple new hardware configurations of this test possible, as well as an additional safety system.

Seagrave, Kayla [DuPage Coll.; Fermilab]↗

Vacuum Studies of a Prototype Composite Coil Dewar for HTSC Transformers

Oak Ridge National Laboratory (ORNL) is collaborating with Waukesha Electric Systems (WES) to develop a high-temperature superconducting (HTSC) utility power transformer with primary and secondary coils cooled by liquid nitrogen. Since the vacuum-insulated cryogenic coil dewar surrounds the magnetic core limb and cannot form a shorted turn, non-conductive materials are required. Two test vessels and a small prototype dewar have been fabricated by Scorpius Space Launch Company with epoxy/fiberglass composites, using their proprietary PRESSURMAXX vessel technology. The effects of pumping time, bakeout temperature, and cryogenic vessel temperature on vacuum outgassing rates have been investigated. Outgassing rates of the individual materials used in vessel construction have also been measured. The results will be scaled up to determine the required pumping capacity for a full-size 25-MVA commercial transformer dewar.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Analyses of the NSTX-U PF1A Poloidal Field Coil Support

New poloidal field (PF) coils and supports have been designed for the National Spherical Torus Experiment Upgrade (NSTX-U) Recovery project. The PF1A coil structural requirements demand a large preload to pre-compress the coil insulation. Coil support design accounts for all operational conditions and loads of NSTX-U including bakeout, seismic events, and electromagnetic loads. Background magnetic fields produce coil Lorentz forces that react on the structural supports. These Lorentz forces include interactions from the coil current and all plasma events: normal operations, disruptions, and vertical displacement events. This paper will detail the design and design loads and highlight some of the analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

R&D ERL: Vacuum

The ERL Vacuum systems are depicted in a figure. ERL has eight vacuum volumes with various sets of requirements. A summary of vacuum related requirements is provided in a table. Five of the eight volumes comprise the electron beamline. They are the 5-cell Superconducting RF Cavity, Superconducting e-gun, injection, loop and beam dump. Two vacuum regions are the individual cryostats insulating the 5-cell Superconducting RF Cavity and the Superconducting e-gun structures. The last ERL vacuum volume not shown in the schematic is the laser transport line. The beamline vacuum regions are separated by electropneumatic gate valves. The beam dump is common with loop beamline but is considered a separate volume due to geometry and requirements. Vacuum in the 5-cell SRF cavity is maintained in the {approx}10{sup -9} torr range at room temperature by two 20 l/s ion pumps and in the e-gun SRF cavity by one 60 l/s ion pump. Vacuum in the SRF cavities operated at 2{sup o}K is reduced to low 10{sup -11} torr via cryopumping of the cavity walls. The cathode of the e-gun must be protected from poisoning, which can occur if vacuum adjacent to the e-gun in the injection line exceeds 10-11 torr range in the injection warm beamline near the e-gun exit. The vacuum requirements for beam operation in the loop and beam dump are 10-9 torr range. The beamlines are evacuated from atmospheric pressure to high vacuum level with a particulate free, oil free turbomolecular pumping cart. 25 l/s shielded ion pumps distributed throughout the beamlines maintain the vacuum requirement. Due to the more demanding vacuum requirement of the injection beamline proximate to the e-gun, a vacuum bakeout of the injection beamline is required. In addition, two 200 l/s diode ion pumps and supplemental pumping provided by titanium sublimation pumps are installed in the injection line just beyond the exit of the e-gun. Due to expected gas load a similar pumping arrangement is planned for the beam dump. The cryostat vacuum thermally insulating the SRF cavities need only reduce the convective heat load such that heat loss is primarily radiation through several layers of multi-layer insulation and conductive end-losses which are contained by 5{sup o}K thermal transitions. Prior to cool down rough vacuum {approx}10{sup -5} torr range is established and maintained by a dedicated turbomolecular pump station. Cryopumping by the cold mass and heat shields reduces the insulating vacuum to 10{sup -7} torr range after cool down.

43 PARTICLE ACCELERATORS↗

Plasma Switch for High-Power Active Pulse Compressor

Results are presented from experiments carried out at the Naval Research Laboratory X-band magnicon facility on a two-channel X-band active RF pulse compressor that employed plasma switches. Experimental evidence is shown to validate the basic goals of the project, which include: simultaneous firing of plasma switches in both channels of the RF circuit, operation of quasi-optical 3-dB hybrid directional coupler coherent superposition of RF compressed pulses from both channels, and operation of the X-band magnicon directly in the RF pulse compressor. For incident 1.2 μs pulses in the range 0.63 - 1.35 MW, compressed pulses of peak powers 5.7 - 11.3 MW were obtained, corresponding to peak power gain ratios of 8.3 - 9.3. Insufficient bakeout and conditioning of the high-power RF circuit prevented experiments from being conducted at higher RF input power levels.

43 PARTICLE ACCELERATORS↗

Assessment of Electrode Contamination Mitigation at 0.5 MA Scale

The Z Machine at Sandia National Laboratories uses current pulses with peaks up to 27 MA to drive target implosions and generate high energy density conditions of interest for stockpile stewardship programs pertinent to the NNSA program portfolio . Physical processes in the region near the Z Machine target create electrode plasmas which seed parasitic current loss that reduce the performance and output of a Z experiment. Electrode surface contaminants (hydrogen, water, hydrocarbons) are thought to be the primary constituent of electrode plasmas which contribute to loss mechanisms. The Sandia team explore d in situ heating and plasma discharge techniques by integrating requisite infrastructure into Sandia's Mykonos LTD accelerator, addressing potential impacts to accelerator operation, and reporting on the impact of these techniques on electrode plasma formation and shot performance. The in situ discharge cleaning utilizes the electrodes of the accelerator to excite an argon-oxygen plasma to sputter and chemically react contaminants from electrode surfaces. Insulating breaks are required to isolate the plasma in electrode regions where loss processes are most likely to occur. The shots on Mykonos validate that these breaks do not perturb experiment performance, reducing the uncertainty on the largest unknown about the in situ cleaning system. Preliminary observations with electrical and optical diagnostics suggest that electrode plasma formation is delayed, and overall inventory has been substantively reduced. In situ heating embeds cartridge heaters into accelerator electrodes and employs a thermal bakeout to rapidly desorb contaminants from electrode surfaces. For the first time, additively manufactured (AM) electrode assemblies were used on a low impedance accelerator to integrate cooling channels and manage thermal gradients. Challenges with poor supplier fabrication to specifications, load alignment, thermal expansion and hardware movement and warpage appears to have introduced large variability in observed loss, though, preventing strong assertions of loss reduction via in situ heating. At this time, an in situ discharge cleaning process offers the lowest risk path to reduce electrode contaminant inventories on Z, though we recommend continuing to develop both approaches. Additional engineering and testing are required to improve the implementation of both systems. .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Material Selection and Operational Conditions for XHV Systems: Lessons from AISI 1020 and 316L Comparative Studies

In this study, AISI 1020 low-carbon steel is investigated as a cost-effective alternative to SS316 stainless steel for reaching extreme high vacuum (XHV) conditions. After being baked at 400°C, a vacuum chamber made of the low-carbon steel material exhibited an outgassing rate approximately 2000 times smaller than a similar chamber made of stainless steel. Its activation energy for hydrogen diffusion (27 kJ/mol) is less than half that of stainless steel (60.3 kJ/mol), indicating more efficient hydrogen removal during bakeout. MolFlow+ simulations supported the experimental data and demonstrated the importance of system geometry optimization and minimizing stainless steel content for achieving optimal vacuum performance. AISI 1020's magnetic properties, typically considered disadvantageous for accelerator applications, could benefit spin-polarized electron sources by shielding photocathodes from stray fields while simultaneously providing improved vacuum through reduced outgassing. To optimize AISI 1020's performance in XHV systems, practical considerations include pre-baking protocols and careful system design to minimize stainless steel components.

Al-Allaq, Aiman H.↗

In situ transfer standard for ultrahigh vacuum gage calibration

A compact insitu calibration assembly, for ultrahigh vacuum gauges is described. The system depends on the repeatable generation of a specific gas pressure by the dissociation of a solid solution chemical compound when subjected to a given temperature. A precise temperature measurement is related to the pressure generated within the vacuum by the properties of the solid solution compound. this accurately establishes the gas pressure which in turn is used to calibrate a vacuum gauge. Also included is a metering orifice used in the calibration system and which is made movable to facilitate the degassing bakeout required in ultrahigh vacuum devices.

Outlaw, R. A.↗

The role of hybrid construction techniques on sealed moisture levels

Residual gas analysis techniques were employed to measure the moisture in sealed hybrid packages as a function of substrate attach material, vacuum bake time and sequence, and sealing procedure. It is shown that when room atmospheric exposure is eliminated following the vacuum bakeout moisture levels of less than 1000 ppm may be achieved for modest bake times and solder substrate attach techniques. Suitable moisture levels were achieved for epoxy attached substrates only when seam sealing procedures were employed.

Somerville, D. T.↗

Proposed method for degassing metals for extreme low pressures

Metal outgassing currently limits the pressures attained in vacuum chambers. The dominant residual gas in a carefully degassed metal system is usually hydrogen. The atomic hydrogen within bulk metals could be removed by diffusion processes if surface effects did not interfere. It is proposed that removing the surface hydrogen during vacuum bakeout by continuous electron bombardment (or similar irradiation) would allow the diffusion to proceed and lead to lower outgassing rates and operating pressures.

Moore, B. C.↗

Large area space qualified thermoelectrically (TE) cooled HgCdTe MW photovoltaic detectors for the Halogen Occultation Experiment (HALOE)

Large-area, HgCdTe MW photovoltaic detectors have been developed for the NASA-HALOE instrument scheduled for operation on the Upper Atmospheric Research Satellite. The photodiodes will be TE-cooled and were designed to operate in the 5.1-5.4 micron band at 185 K to measure nitric oxide concentrations in the atmosphere. The active area required 15 micron thick devices and a full backside common contact. Reflections from the backside contact doubled the effective thickness of the detectors. Optical interference from reflections was eliminated with a dual layer front surface A/R coating. Bakeout reliability was optimized by having Au metallization for both n and p interconnects. Detailed performance data and a model for the optical stack are presented.

Norton, P. W.↗

Design, fabrication, and performance of brazed, graphite electrode, multistage depressed collectors with 500-W, continuous wave, 4.8- to 9.6-GHz traveling-wave tubes

A small, isotropic graphite electrode, multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W, continuous wave (CW), 4.8- to 9.6-GHz traveling-wave tube (TWT). The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The brazing technique, which used copper braze filler metal, is compatible with both vacuum and the more commonly available hydrogen atmosphere brazing furnaces. The TWT and graphite electrode MCC bakeout, processing, and outgassing characteristics were evaluated and found to be comparable to TWT's equipped with copper electrode MDC's. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average radiofrequency (RF), overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-hr CW test, conducted without the use of an appendage ion pump, showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter↗

Isotropic graphite multistage depressed collectors - A progress report

A small isotropic-graphite-electrode multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W CW 4.8-9.6-GHz TWT. The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary-electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The TWT and graphite-electrode MDC bakeout and processing (outgassing) characteristics were evaluated and found to be comparable to those for TWTs equipped with copper-electrode MDCs. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average RF, overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-h CW test showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter↗

An overview of the first results on the solar array passive LDEF experiment (sample), AO171

Space environmental effects were visibly obvious on components of experiment AO171 which contained solar cells, composites, polymeric thin films, solar reflectors, protective coatings, metals, paints , and elastomers. Micrometeoroid/space debris impacts were observed on all experiment elements. Luminescence of polyimide, silicone, and polyurethane materials occurred under black light examination. Outgassing of RTV511 occurred mainly as a result of insufficient thermal vacuum bakeout. Solar cell degradation was predominantly below 10 percent. Elastomers lost mass and discolored; composites showed evidence of atomic oxygen attack, and unprotected thin polymer films eroded away.

Whitaker, Ann F.↗