Search NASASearch

SEARCH · Search NASA

Results for “bakeout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Space Environmental Effects on Additively Manufactured (AM) Parts on MISSE-9/10

The Materials on International Space Station Experiment (MISSE) experiments have made a continuous presence on the ISS and allowed for testing of performance and durability of materials exposed to the Low Earth Orbit (LEO) space environment. Additive Manufacturing (AM) has been included on several MISSE flights, and many companies (Made in Space and Stratasys) and NASA centers wanted to test various AM material samples. The goal of studying Space Environmental Effects on AM Parts with MISSE 9/10 was to fly promising metal and polymer AM material samples (dogbones) that could have future manufacturing capabilities in space and conduct post-flight analysis of these materials via mechanical and optical properties. On these flights, MISSE-9 contained three Inconel and 12 polymer samples and MISSE-10 included three Inconel and 16 polymer samples. Before flying to the ISS, all the samples underwent thermal vacuum bakeout (at 60°C for 24 hours and 10-6 torr). After bakeout, control and flight experiments were weighed, and optical properties were taken. Optical properties such as solar absorptance and infrared emittance were taken on the control samples and the flight samples (preflight and postflight). To understand more about the mechanical properties of the AM samples, tensile testing was conducted on the samples to determine the yield and ultimate tensile strength of the dogbone samples against the control. Lastly, the torque on the fasteners securing the dogbone samples were loosened and measured using a torque wrench, and they were compared to their preflight torque specification required. Optical properties and masses were recorded before flight, and the postflight results were recorded and collected in June 2022 to study the effects. With the postflight analysis, NASA engineers can now better characterize how UV radiation and thermal cycling affect the material properties.

Materials on International Space Station Experimen

IOTA Pre-Bake Test Development

The IOTA (Integrable Optics Test Accelerator) Bakeout project is intended to improve the quality of the vacuum within the IOTA ring. Impurities consisting of hydrogen and oxygen that build within the beampipe are reduced through applying heat to the beampipe’s exterior. Two versions of the Bakeout project exist, one as a smaller scale test setup, and one five times larger located within the IOTA ring. During my internship, I worked together with a team to bring this project from an effectively dormant state to ready for testing, working together to create full documentation of the PLC (Programmable Logic Controller) programs, making multiple new hardware configurations of this test possible, as well as an additional safety system.

Seagrave, Kayla [DuPage Coll.; Fermilab]

Optimizing Material Selection and Operational Conditions for XHV Systems: Lessons from AISI 1020 and 316L Comparative Studies

In this study, AISI 1020 low-carbon steel is investigated as a cost-effective alternative to SS316 stainless steel for reaching extreme high vacuum (XHV) conditions. After being baked at 400°C, a vacuum chamber made of the low-carbon steel material exhibited an outgassing rate approximately 2000 times smaller than a similar chamber made of stainless steel. Its activation energy for hydrogen diffusion (27 kJ/mol) is less than half that of stainless steel (60.3 kJ/mol), indicating more efficient hydrogen removal during bakeout. MolFlow+ simulations supported the experimental data and demonstrated the importance of system geometry optimization and minimizing stainless steel content for achieving optimal vacuum performance. AISI 1020's magnetic properties, typically considered disadvantageous for accelerator applications, could benefit spin-polarized electron sources by shielding photocathodes from stray fields while simultaneously providing improved vacuum through reduced outgassing. To optimize AISI 1020's performance in XHV systems, practical considerations include pre-baking protocols and careful system design to minimize stainless steel components.

Al-Allaq, Aiman H.

In situ transfer standard for ultrahigh vacuum gage calibration

A compact insitu calibration assembly, for ultrahigh vacuum gauges is described. The system depends on the repeatable generation of a specific gas pressure by the dissociation of a solid solution chemical compound when subjected to a given temperature. A precise temperature measurement is related to the pressure generated within the vacuum by the properties of the solid solution compound. this accurately establishes the gas pressure which in turn is used to calibrate a vacuum gauge. Also included is a metering orifice used in the calibration system and which is made movable to facilitate the degassing bakeout required in ultrahigh vacuum devices.

Outlaw, R. A.

The role of hybrid construction techniques on sealed moisture levels

Residual gas analysis techniques were employed to measure the moisture in sealed hybrid packages as a function of substrate attach material, vacuum bake time and sequence, and sealing procedure. It is shown that when room atmospheric exposure is eliminated following the vacuum bakeout moisture levels of less than 1000 ppm may be achieved for modest bake times and solder substrate attach techniques. Suitable moisture levels were achieved for epoxy attached substrates only when seam sealing procedures were employed.

Somerville, D. T.

Proposed method for degassing metals for extreme low pressures

Metal outgassing currently limits the pressures attained in vacuum chambers. The dominant residual gas in a carefully degassed metal system is usually hydrogen. The atomic hydrogen within bulk metals could be removed by diffusion processes if surface effects did not interfere. It is proposed that removing the surface hydrogen during vacuum bakeout by continuous electron bombardment (or similar irradiation) would allow the diffusion to proceed and lead to lower outgassing rates and operating pressures.

Moore, B. C.

Large area space qualified thermoelectrically (TE) cooled HgCdTe MW photovoltaic detectors for the Halogen Occultation Experiment (HALOE)

Large-area, HgCdTe MW photovoltaic detectors have been developed for the NASA-HALOE instrument scheduled for operation on the Upper Atmospheric Research Satellite. The photodiodes will be TE-cooled and were designed to operate in the 5.1-5.4 micron band at 185 K to measure nitric oxide concentrations in the atmosphere. The active area required 15 micron thick devices and a full backside common contact. Reflections from the backside contact doubled the effective thickness of the detectors. Optical interference from reflections was eliminated with a dual layer front surface A/R coating. Bakeout reliability was optimized by having Au metallization for both n and p interconnects. Detailed performance data and a model for the optical stack are presented.

Norton, P. W.

Design, fabrication, and performance of brazed, graphite electrode, multistage depressed collectors with 500-W, continuous wave, 4.8- to 9.6-GHz traveling-wave tubes

A small, isotropic graphite electrode, multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W, continuous wave (CW), 4.8- to 9.6-GHz traveling-wave tube (TWT). The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The brazing technique, which used copper braze filler metal, is compatible with both vacuum and the more commonly available hydrogen atmosphere brazing furnaces. The TWT and graphite electrode MCC bakeout, processing, and outgassing characteristics were evaluated and found to be comparable to TWT's equipped with copper electrode MDC's. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average radiofrequency (RF), overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-hr CW test, conducted without the use of an appendage ion pump, showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter

Isotropic graphite multistage depressed collectors - A progress report

A small isotropic-graphite-electrode multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W CW 4.8-9.6-GHz TWT. The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary-electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The TWT and graphite-electrode MDC bakeout and processing (outgassing) characteristics were evaluated and found to be comparable to those for TWTs equipped with copper-electrode MDCs. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average RF, overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-h CW test showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter

An overview of the first results on the solar array passive LDEF experiment (sample), AO171

Space environmental effects were visibly obvious on components of experiment AO171 which contained solar cells, composites, polymeric thin films, solar reflectors, protective coatings, metals, paints , and elastomers. Micrometeoroid/space debris impacts were observed on all experiment elements. Luminescence of polyimide, silicone, and polyurethane materials occurred under black light examination. Outgassing of RTV511 occurred mainly as a result of insufficient thermal vacuum bakeout. Solar cell degradation was predominantly below 10 percent. Elastomers lost mass and discolored; composites showed evidence of atomic oxygen attack, and unprotected thin polymer films eroded away.

Whitaker, Ann F.

Strategy for contamination control to improve Wide-Field/Planetary Camera far-ultraviolet performance

A multifaceted contamination control strategy has been developed for the second generated Wide-Field and Planetary Camera (WFPC-2) to improve the FUV stability by several orders of magnitude, compared to the first camera (WFPC-1). The strategy involves: improved on-orbit boil-off capability of the detector optics, added internal shielding and instrument venting, in-process subassembly vacuum bakeout at elevated temperatures, material substitution, sample testing in ultraclean vacuum facility, and internal instrument contamination-transport modeling. A science performance goal of 1 percent photometric accuracy at 1470 A over an extended time (of at least 30 days) has been established as a contamination control target for WFPC-2. The WFPC-2 is currently planned to be launched by the Shuttle in mid-1993 and replace the WFPC-1 which was recently launched with the HST.

Leschly, Kim

Four space application material coatings on the long-duration exposure flight (LDEF)

Four material coatings of different thickness were flown on the LDEF to determine their ability to perform in the harsh space environment. The coatings, located in the ram direction of the spacecraft, were exposed for 10 months to the low-Earth orbit (LEO) environment experienced by the LDEF at an orbit of 260 nautical miles. They consisted of indium oxide (In2O3), silicon oxide (SiO(x)), clear RTV silicone, and silicone with silicate-treated zinc oxide (ZnO). These coatings were flown to assess their behavior when exposed to atomic oxygen and to confirm their good radiative properties, stability, electrical conductivity, and resistance to UV exposure. The flown samples were checked and compared with the reference unflown samples using high-magnification optical inspection, ESCA analysis, weight changes and dimensional changes. These comparisons indicated the following: The 1000 A SiO(x) coating eroded uniformly, with minor changes in its radiative properties. The 100 A of In2O3 coating eroded completely down to the Kapton backing, with resultant losses of reflectance. The RTV-615 showed erosion, with carbon (C) content losses, while the Si remained constant, with a doubling of the oxygen (O) concentration. The RTV-615 silicone with K2SiO3-treated ZnO changed from flat to glossy white in appearance. It lost C, was etched, and increased its O content. The upper layers showed no remaining Zn or K. Losses of reflectance occurred within certain wavelength bands. It was not possible to evaluate the experimental oxygen reaction rate using the calculated atomic oxygen fluence of 2.6 x 10(exp 20) atoms/cm(exp 2) for the exposure of these coatings during the flight. The bakeout of the coatings was not carried out prior to the flight. Hence, the coating weight and dimensional losses included losses by outgassing products.

Scialdone, John J.

A broadband THz receiver for low background space applications

We have developed a sensitive bolometric receiver for low background space applications. In a 10 percent bandwidth at 1 THz, this receiver is approximately 100 times more sensitive than a quantum limited heterodyne receiver with a 1 GHz IF bandwidth. This receiver is designed to be used for the long wavelength band (200-700 microns) in the MIPS instrument on NASA's SIRTF satellite. The bolometers are cooled to 100 mK by an adiabatic demagnetization refrigerator. Roughly 60 g of cesium chrome alum salt is partially demagnetized to 100 mK, followed by a slow regulated downramp to compensate for the heat leak. The hold time of the ADR system is about 18 hours with a temperature stability of delta T(sub rms) approx. equals 10 micro-K. The composite bolometers have electrical responsivities of 10(exp 9)V/W and electrical NEP's of about 3x10(exp -17) W/square root of Hz. The bolometer signals are read out by JFET preamplifiers located on the helium plate and operated at 120 K. We have addressed a number of space qualification issues, such as the development of an analog magnet controller, construction of a cryogenic shake-table for bolometers and selection of the paramagnetic salt CCA which can survive a bakeout at 50 C. The receiver is scheduled to be flown in the spring of 1992 on a balloon telescope. This flight has a dual purpose. One is to provide realistic test of the capabilities of the new receiver. The other is to search for anisotropies in the cosmic microwave background on scales of a few degrees.

Hagmann, C.

Performance of low resistance microchannel plate stacks

Results are presented from an evaluation of three sets of low resistance microchannel plate (MCP) stacks; the tests encompassed gain, pulse-height distribution, background rate, event rate capacity as a function of illuminated area, and performance changes due to high temperature bakeout and high flux UV scrub. The MCPs are found to heat up, requiring from minutes to hours to reach stabilization. The event rate is strongly dependent on the size of the area being illuminated, with larger areas experiencing a gain drop onset at lower rates than smaller areas.

Siegmund, O. H. W.

Self contamination effects in the TAUVEX UV Telescope: Ground testing and computer simulation

The contamination effects due to outgassing from construction materials of the TAUVEX (Tel Aviv University UV Telescope) were evaluated using a combination of ground testing and computer simulations. Tests were performed from the material level of the system level including: (1) High sensitivity CVCM(10(exp -3 percent) measurements of critical materials. (2) Optical degradation measurements of samples specially contaminated by outgassing products at different contamination levels. (3) FTIR studies of chemical composition of outgassed products on above samples. (4) High resolution AFM studies of surface morphology of contaminated surfaces. The expected degradation of TAUVEX performance in mission was evaluated applying a computer simulation code using input parameters determined experimentally in the above tests. The results have served as guidelines for the proper selection of materials, cleanliness requirements, determination of the thermal conditions of the system and bakeout processes.

Lifshitz, Y.

Four space application material coatings on the Long-Duration Exposure Facility (LDEF)

Four material coatings of different thicknesses were flown on the LDEF to determine their ability to perform in the harsh space environment. The coatings, located in the ram direction of the spacecraft, were exposed for 10 months to the low-Earth orbit (LEO) environments experienced by the LDEF at an orbit of 260 nautical miles. They consisted of indium oxide (In2O3), silicon oxide (SiO(x)), clear RTV silicone, and silicone with silicate-treated zinc oxide (ZnO). These coatings were flown to assess their behavior when exposed to atomic oxygen and to confirm their good radiative properties, stability, electrical conductivity, and resistance to UV exposure. The flown samples were checked and compared with the reference unflown samples using high-magnification optical inspection, ESCA analysis, weight changes, and dimensional changes. These comparisons indicated the following. The 1000 A SiO(x) coating eroded uniformly, with minor changes in its radiative properties. The 100 A In2O3 coating eroded completely down to the Kapton backing, with resultant losses of reflectance. The RTV-615 showed erosion, with carbon (C) content losses, while the Si remained constant, with a doubling of the oxygen (O) concentration. The RTV-615 silicone with K2SiO3-treated ZnO changed from flat to glossy white in appearance. It lost C, was etched, and increased its O content. The upper layers showed no remaining Zn or K. Losses of reflectance occurred within certain wavelength bands. It was not possible to evaluate the experimental oxygen reaction rate using the calculated atomic oxygen fluence of 2.6 x 10(exp 20) atoms/cm(exp 2) for the exposure of these coatings during the flight. The bakeout of the coatings was not carried out prior to the flight. Hence, the coating weight and dimensional losses included losses by outgassing products.

Scialdone, John J.

Thermal Performance of LANDSAT-7 ETM+ Instruments During First Year in Flight

Landsat-7 was successfully launched into orbit on April 15, 1999. After devoting three months to the t bakeout and cool-down of the radiative cooler, and on- t orbit checkout, the Enhanced Thematic Mapper Plus (ETM+) began the normal imaging phase of the mission in mid-July 1999. This paper presents the thermal performance of the ETM+ from mid-July 1999 to mid-May 2000. The flight temperatures are compared to the yellow temperature limits, and worst cold case and worst hot case flight temperature predictions in the 15-orbit mission design profile. The flight temperature predictions were generated by a thermal model, which was correlated to the observatory thermal balance test data. The yellow temperature limits were derived from the flight temperature predictions, plus some margins. The yellow limits work well in flight, so that only several minor changes to them were needed. Overall, the flight temperatures and flight temperature predictions have good agreement. Based on the ETM+ thermal vacuum qualification test, new limits on the imaging time are proposed to increase the average duty cycle, and to resolve the problems experienced by the Mission Operation Team.

Choi, Michael K.