Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam independence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of beam–beam effects on absolute luminosity calibrations at the CERN Large Hadron Collider

At the Large Hadron Collider (LHC), absolute luminosity calibrations obtained by the van der Meer (vdM) method are affected by the mutual electromagnetic interaction of the two beams. The colliding bunches experience relative orbit shifts, as well as optical distortions akin to the dynamic-β effect, that both depend on the transverse beam separation and must therefore be corrected for when deriving the absolute luminosity scale. In the vdM regime, the beam–beam parameter is small enough that the orbit shift can be calculated analytically. The dynamic-β corrections to the luminometer calibrations, however, had until the end of Run 2 been estimated in the linear approximation only. In this report, the influence of beam–beam effects on the vdM-based luminosity scale is quantified, together with the associated systematic uncertainties, by means of simulations that fully take into account the non-linearity of the beam–beam force, as well as the resulting non-Gaussian distortions of the transverse beam distributions. Two independent multiparticle simulations, one limited to the weak-strong approximation and one that models strong-strong effects in a self-consistent manner, are found in excellent agreement; both predict a percent-level shift of the absolute pp-luminosity values with respect to those assumed until recently in the physics publications of the LHC experiments. These results also provide guidance regarding further studies aimed at reducing the beam–beam-related systematic uncertainty on beam–beam corrections to absolute luminosity calibrations by the van der Meer method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam optics ramping in underconstrained lattice design: Application to Electron-Ion Collider hadron storage ring cooling section

This paper presents the lattice design and optics ramping strategy for the cooling section of the hadron storage ring at the electron-ion collider. The main challenge is that available tuning knobs exceed beam-optics constraints. Independently optimized injection and top-energy optics often yield disconnected solutions, making interpolation impossible. To address this, we propose two new methods. The first is an intermediate-penalty scheme that ensures ramping path continuity by penalizing constraint violations at intermediate states. The second is a continuation-based approach that adapts high-energy optics to low energy, guided by an adaptive weighting scheme to balance injection and ramping constraints. The solutions meet all beam dynamics and hardware limits. The two methods offer a general strategy for ramping in systems where the solution space is under-constrained and the starting and target configurations are far apart.

43 PARTICLE ACCELERATORS↗

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS↗

Synthesis and Physical Properties of Manganese Chromium Nitride Thin Films Grown via Molecular Beam Epitaxy

Here, we demonstrate the ability to grow epitaxial thin films of manganese–chromium nitride (Mn x Cr 1–x N) across the entire composition range on magnesium oxide (MgO) (1 0 0) surfaces by molecular beam epitaxy. By independently controlling the ratio of the atomic fluxes of manganese and chromium, the compositional dependence of structural and electrical transport properties is determined. Soft X-ray absorption shows that the valence states of Cr( 3+ ) and Mn( 3+ ) remain identical among these MnCrN epitaxial films. The metallic transport behavior of binary manganese nitride (MnN) and chromium nitride (CrN) is suppressed in the ternary alloys. Changes in room temperature electrical resistivity of up to 100 times and 5 orders of magnitude at cryogenic temperatures are observed. This work expands the variety of nitride compounds available for epitaxial integration and could provide additional flexibility for the development of metal–semiconductor–insulator junctions for spintronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absorptive corrections to the electromagnetic form factor in high-energy elastic proton-proton scattering

Recently, it was noted that absorptive corrections to the electromagnetic form factor in high-energy proton-proton scattering are important for the theoretical interpretation of the p ↑ p and p ↑ A analyzing power A N ( t ) measurements with the Hydrogen Jet Target polarimeter (HJET) at RHIC. Here, a concise expression for the absorptive correction was derived within the eikonal approach. The resulting analysis reveals a systematic bias, nearly independent of the beam energy, in the experimental determination of the real-to-imaginary ratio ρ when absorption effects are overlooked in the data analysis. Quantification of this bias, as ρ meas = ρ + ( 0.036 ± 0.016 ) bias , was achieved using a Regge fit applied to available proton-proton measurements of ρ meas ( s ) and σ tot meas ( s ) . Considering the potential impact of such an effect on the experimentally determined A N ( t ) , one may enhance consistency between the HJET and STAR measurements of the hadronic spin-flip amplitude. While the sign of the bias in the value of ρ aligns with the anticipated effective increase in the proton charge radius in p p scattering due to absorption, it amplifies the observed discrepancy between σ tot meas and ρ meas values at s = 13 TeV as measured in the TOTEM experiment. Evaluation (using published TOTEM data) of the measured proton-proton d σ / d t dependence on the absorptive corrections indicated that possible soft photon corrections to the hadronic amplitude slope may be essential for such data analysis. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Charge per Micro-Pulse Calculation for Ideal Lujan and WNR beams

A complete redesign of the LANSCE front-end is currently under development for the Los Alamos Modernization Project (LAMP). This includes the replacement of the traditional Cockroft-Walton injection system to the newer radiofrequency quadrupole (RFQ) standard. LANSCE accelerates both H- and H+ beams and therefore requires an unconventional application for RFQ systems. A new facility could consider using an independent RFQ for each beam species. However, with the tight space of the LANSCE injector facility, it would prove difficult to instrument. Our initial studies have shown that a single RFQ could be used. The negatively- and positively-charged direct current (DC) beams are shaped, bunched, and accelerated out of phase to each other, with very little interaction. This would work for all possible H+ beam gates and most H- Beam gates. However, a challenge arises with the Weapons Neutron Research (WNR) beam structure that requires the acceleration of bunched beams at higher charge density per pulse. The Long Bunch Enable Gate (LBEG) used for the Lujan center is the best example of a standard injector beam gate. The beam gate, or Macro-Pulse (MP), is 625-us long, separated by at least 8.3 ms. A chopper is used to dice the MP into 1750 mini-Pulses (mP), which are 290-ns wide. After chopping, the MP contains 100,000 micro-Pulses (uP), which are generated by the linac acceleration structure modulated at 201.25 MHz; that is, the micro-Pulses are separated 5 ns apart from each other. The H+ beam structure will be very similar once a chopper is added to its transport. However, the Multi-Pulse Enable Gate (MPEG) used for WNR is significantly different in structure. In this case, the mP is chopped to be only 35-ns wide. This width is then rotated into a single 201.25 MHz RF bucket using the Low Frequency Buncher (LFB). This is proving difficult for the RFQ design in the LAMP upgrade. We began investigating the amount of current sent to WNR for two reasons. Firstly, we wanted to find a solution to avoid using the Low Frequency Buncher to simplify the LAMP RFQ design. It is simple to inject and accelerate a 35 mA DC beam in the LAMP RFQ (this is done in numerous accelerator facilities). However, injecting a short bunch with a larger current (once compressed to 5 ns to meet the RFQ frequency) may be difficult. Second, we have a technique called PSR2WNR in which we do not employ the Low Frequency Buncher, but rather accumulate 5 LBEG uP (5 ns) in the PSR and deliver the accumulated beam to WNR every 1.8 us. As a result, we could provide to WNR with five accumulated LBEG uPs every shot. The goal here is to create a rapid kicker with a frequency response of 555 kHz. DARHT-II and other accelerator facilities have constructed kickers of this type for other uses, and our engineers consider this technology as feasible.

43 PARTICLE ACCELERATORS↗

Correlated characterization of 20 Ne-implanted targets using nuclear reaction analysis, Rutherford backscattering spectrometry, and ion transport modeling

In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

RFQ Beam Loss and Shielding Consideration

The proposed novel RFQ-based injector for LANSCE operation includes two independent low energy transports merging beams at the entrance of a single RFQ, which accelerates simultaneously both protons and H- ions with multiple flavors of the beams. One of the design issues of the project is the estimation of shielding requirements for the injector. Continuous access to the injector components reduces the number of times required to open the linac tunnel and saves time for the operation. Estimation involves the evaluation of radiation generated by beam losses in the injector. In this paper, we present an overview of the shielding in existing RFQ injectors and discuss the aspects of shielding configuration for the LANSCE RFQ-based injector.

43 PARTICLE ACCELERATORS↗

Mitigation of Beam Losses in LANSCE Linear Accelerator

Suppression of beam losses is essential for successful operation of high-intensity accelerator facility. The LANSCE accelerator started routine operation in 1972 as a 0.8 MW average proton beam power facility for meson physics research, and delivered highpower beam for a quarter century. The accelerator currently delivers 100 MeV proton beam to Isotope Production Facility (IPF) and 800 MeV H- beams to various experimental areas. The accelerator is equipped with two independent injectors for H + and H - beams, merging at the entrance of a 201.25 MHz Drift Tube Linac (DTL). The DTL performs acceleration up to the energy of 100 MeV. After the DTL, the Transition Region beamline directs a 100 MeV proton beam to the Isotope Production Facility, while the H - beam is accelerated up to the final energy of 800 MeV in an 805- MHz Coupled Cavity Linac. The H - beams, created with different time structure by a lowenergy chopper, are distributed in the Switch Yard (SY) to four experimental areas: the Lujan Neutron Scattering Center equipped with a Proton Storage Ring (PSR), the Weapons Neutron Research facility (WNR), the Proton Radiography facility (pRad), and the Ultra-Cold Neutron facility (UCN). Multi-beam operation requires careful control of accelerator tune to minimize beam losses. In this paper we review main effects affecting beam losses in LANSCE linear accelerator and discuss methods to reduce them.

43 PARTICLE ACCELERATORS↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Chemical and physical transformations of carbon-based nanomaterials observed by liquid phase transmission electron microscopy

This article addresses recent advances in liquid phase transmission electron microscopy (LPTEM) for studying nanoscale synthetic processes of carbon-based materials that are independent of the electron beam—those driven by nonradiolytic chemical or thermal reactions. In particular, we focus on chemical/physical formations and the assembly of nanostructures composed of organic monomers/polymers, peptides/DNA, and biominerals. The synthesis of carbon-based nanomaterials generally only occurs at specific conditions, which cannot be mimicked by aqueous solution radiolysis. Carbon-based structures themselves are also acutely sensitive to the damaging effects of the irradiating beam, which make studying their synthesis using LPTEM a unique challenge that is possible when beam effects can be quantifi ed and mitigated. With new direct sensing, high frame rate cameras, and advances in liquid-cell holder designs, combined with a growing understanding of irradiation effects and proper experimental controls, microscopists have been able to make strides in observing traditionally problematic carbon-based materials under conditions where synthesis can be controlled, and imaged free from beam effects, or with beam effects quantified and accounted for. These materials systems and LPTEM experimental techniques are discussed, focusing on nonradiolytic chemical and physical transformations relevant to materials synthesis.

Parent, Lucas R.↗

Timelike Compton Scattering from a longitudinally polarised target with CLAS12 at Jefferson Lab

Explorations into the internal dynamics of hadrons are constantly evolving, and the requirement for experimental results to verify theoretical models of hadron structure is paramount. A key area in this field is the study of Generalised Parton Distributions (GPDs), which are functions used to model the momenta of quarks and gluons within hadrons, and the methods to access GPDs experimentally. One such scattering process that allows access to these is Timelike Compton Scattering. TCS complements existing Deeply Virtual Compton Scattering experiments and allows investigation into the universality of GPDs through access to the real and imaginary parts of the parton helicity independent GPD Hq via beam spin asymmetries (BSA), and it provides novel access to the real and imaginary parts of the parton helicity dependent GPD ˜Hq through target polarisation asymmetries (TSA). This thesis work presents a comparative study with the first published BSA for TCS at the Thomas Jefferson National Accelerator Facility (JLab), alongside a first time extraction of a Target Spin Asymmetry with the Summer 2022 data taking run. JLab hosts the Continuous Electron Beam Accelerator Facility (CEBAF) which provides a 12 GeV electron beam to four experimental halls. Hall-B contains the CEBAF Large Acceptance Spectrometer, which took data across three run periods on a longitudinally polarised NH3 and ND3 fixed target from 2022-2023, to extract measurements of electron-proton scattering, from which a TCS signal could be extracted. The thesis discusses work done to understand and eliminate contributions from the non-/low-polarised nuclear background, testing pre-established cuts to eliminate pion background from a dilepton (e+e-) final state and modifying them as needed for the new experimental run, and attempts to hone in on a clean TCS signal from which to extract the two asymmetry observables. A comparison with existing BSA results was performed; however, the statistical errors are too large to draw a significant conclusion as to whether there is agreement across each bin. More data is needed for a multidimensionally binned extraction. A proof of principle was achieved in the TSA measurements, with two out of four kinematic bins showing preliminary agreement in shape with theoretical values. Again, the errors are significant due to the contributions from the nuclear background. To support these conclusions, a further study was done, which takes into account an estimate of the asymmetries with the full available dataset (this thesis is based only on data taken in the summer set; at the time of writing processing was still being conducted for the final two datasets), as well as an estimate including additional future experiment days that were awarded in July 2024. Additional work was done on a secondary project exploring the feasibility of measuring TCS at the upcoming Electron Ion Collider, supporting the design proposal for the detector for the first interaction region and giving a positive outlook for the future of these types of measurements beyond JLab.

Gates, Kayleigh [Univ. of Glasgow, Scotland (Unite↗

Analysis of Allison Scanner Phase Portraits Using Action-Phase Coordinates

Allison scanners provide detailed information on the beam transverse phase space. An effective way for analyzing the beam distribution from these measurements is to use action-phase coordinates, where beam propagation in a linear lattice is reduced to advancing the phase. This report presents such analysis for measurements performed with a 2.1 MeV, 5 mA H⁻ beam in the MEBT of the PIP2IT test accelerator at Fermilab. In part, with the choice of calculating the Twiss parameters over the high intensity portion of the beam, the beam core is found to be phase-independent with intensity decreasing exponentially with action, while the beam tails exhibit a clear phase dependence that is stable over the beam line.

43 PARTICLE ACCELERATORS↗

Measuring dark neutrinos and light using external and internal components of LArTPCs

The so-called MiniBooNE low-energy excess has been a long-standing questionfor beyond Standard Model (BSM) physics in the neutrino field. The ShortBaseline Neutrino (SBN) program was proposed to investigate and provide furtherinsights into this excess. The SBN program utilises Liquid Argon Time ProjectionChamber (LArTPC) technology, which allows for precise measurements of neutrinointeractions and holds great potential for addressing significant open questions inthe field. Within the SBN program, the Short Baseline Near Detector (SBND) plays acrucial role as one of the near detector, positioned just 110 meters from the neutrinosource. Being located on the surface, SBND is exposed to cosmic-ray background,and to mitigate this, the Cosmic Ray Tagger (CRT) system has been implemented toidentify and veto cosmic background events, thereby enhancing the purity of neutrinointeractions. Additionally, the CRT system can be used to search for BSM signatures,such as the dark neutrinos, which have been proposed to explain the MiniBooNElow-energy excess. This thesis presents a novel approach for searching for darkneutrinos using existing SBND CRT data, collected with a unique setup called theCRT Beam Telescope. An extended model-independent search based on the darkneutrino analysis is also presented. The sensitivity plot for the CRT Beam Telescopeis compared with an estimated MiniBooNE exclusion limit. Furthermore, this thesiscovers the commissioning work conducted for the SBND CRT system, which is vitalfor ensuring optimal performance. The LArTPC technology also benefits from liquidargon’s excellent scintillation properties, producing abundant scintillation light. Thisthesis describes a method developed to understand the detector response to thescintillation light produced across the LArTPC, enhancing our understanding of thedetector’s performance and facilitating more accurate measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam-energy dependence of identified two-particle angular correlations in $\sqrt{S_{NN}} = 7.7 – 200$ GeV Au + Au collisions

The two-particle angular correlation functions, $R_2$ , of pions, kaons, and protons in Au + Au collisions at $\sqrt{S_{NN}}$ = 7.7 , 11.5 , 14.5 , 19.6 , 27 , 39 , 62.4 , and 200 GeV were measured by the STAR experiment at the BNL Relativistic Heavy Ion Collider. These correlations were measured for both like-sign and unlike-sign charge combinations and versus the centrality. The correlations of pions and kaons show the expected near-side (i.e., at small relative angles) peak resulting from short-range mechanisms. The amplitudes of these short-range correlations decrease with increasing beam energy. However, the proton correlation functions exhibit strong anticorrelations in the near-side region. This behavior is observed for the first time in an A + A collision system. The observed anticorrelation is $p_T$ independent and decreases with increasing beam energy and centrality. The experimental results are also compared to the Monte Carlo models UrQMD, Hijing, and AMPT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncovering Hidden Entanglement in Twin Beams

Proper characterization of quantum correlations in multimode optical quantum states is critical for applications in quantum information science. However, standard entanglement measurements can lead to incomplete state reconstruction and characterization. Here, we implement a resonator-based detection system that reveals entanglement between sideband modes of twin beams, achieving full tomography and retrieving often ignored quantum correlations. Unlike standard spectral measurements such as homodyne detection, resonator detection can independently address the sidebands of each beam, thereby accessing these hidden correlations. Additionally, we show how phase shifts between the carrier and the sideband modes of the involved fields redistribute information and modify the observation of entanglement for different witnesses. The ability of the resonant detection to independently address sideband modes of entangled states can contribute to enhancing the capacity for secure communication and quantum networking protocols.

Rincon Celis, Raul [University of Sao Paulo, Brazi↗

Ground observations of a space laser for the assessment of its in-orbit performance

The wind mission Aeolus of the European Space Agency was a groundbreaking achievement for Earth observation. Between 2018 and 2023, the space-borne lidar instrument ALADIN onboard the Aeolus satellite measured atmospheric wind profiles with global coverage, which contributed to improving the accuracy of numerical weather prediction. The precision of the wind observations, however, declined over the course of the mission due to a progressive loss of the atmospheric backscatter signal. The analysis of the root cause was supported by the Pierre Auger Observatory in Argentina whose fluorescence detector registered the ultraviolet laser pulses emitted from the instrument in space, thereby offering an estimation of the laser energy at the exit of the instrument for several days in 2019, 2020, and 2021. The reconstruction of the laser beam not only allowed for an independent assessment of the Aeolus performance, but also helped to improve the accuracy in the determination of the laser beam’s ground track on single pulse level. The results presented in this paper set a precedent for the monitoring of space lasers by ground-based telescopes and open new possibilities for the calibration of cosmic-ray observatories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗