Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

6-D weak-strong beam-beam simulation study of proton lifetime in presence of head-on beam-beam compensation in the RHIC

In this note we summarize the calculated particle loss of a proton bunch in the presence of head-on beam-beam compensation in the Relativistic Heavy Ion Collider (RHIC). To compensate the head-on beam-beam effect in the RHIC 250 GeV polarized proton run, we are introducing a DC electron beam with the same transverse profile as the proton beam to collide with the proton beam. Such a device is called an electron lens (e-lens). In this note we first present the optics and beam parameters and the tracking setup. Then we calculate and compare the particle loss of a proton bunch with head-on beam-beam compensation, phase advance of k{pi} between IP8 and the center of the e-lens and second order chromaticity correction. We scanned the proton beam's linear chromaticity, working point and bunch intensity. We also scanned the electron beam's intensity, transverse beam size. The effect of the electron-proton transverse offset in the e-lens was studied. In the study 6-D weak-strong beam-beam interaction model a la Hirata is used for proton collisions at IP6 and IP8. The e-lens is modeled as 8 slices. Each slice is modeled with as drift - (4D beam-beam kick) - drift.

43 PARTICLE ACCELERATORS↗

Simulation of H{sup -} ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator

A three-dimensional ion optical code IBSimu, which is being developed at University of Jyvaeskylae, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H{sup -} ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H{sup -} currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transcranial phase aberration correction using beam simulations and MR-ARFI

Purpose: Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-ARFI technique to achieve aberration correction for transcranial MR-guided focused ultrasound surgery. The technique uses ultrasound beam propagation simulations with MR Acoustic Radiation Force Imaging (MR-ARFI) to correct skull-caused phase aberrations. Methods: Skull-based numerical aberrations were obtained from a MR-guided focused ultrasound patient treatment and were added to all elements of the InSightec conformal bone focused ultrasound surgery transducer during transmission. In the first experiment, the 1024 aberrations derived from a human skull were condensed into 16 aberrations by averaging over the transducer area of 64 elements. In the second experiment, all 1024 aberrations were applied to the transducer. The aberrated MR-ARFI images were used in the hybrid simulation-MR-ARFI technique to find 16 estimated aberrations. These estimated aberrations were subtracted from the original aberrations to result in the corrected images. Each aberration experiment (16-aberration and 1024-aberration) was repeated three times. Results: The corrected MR-ARFI image was compared to the aberrated image and the ideal image (image with zero aberrations) for each experiment. The hybrid simulation-MR-ARFI technique resulted in an average increase in focal MR-ARFI phase of 44% for the 16-aberration case and 52% for the 1024-aberration case, and recovered 83% and 39% of the ideal MR-ARFI phase for the 16-aberrations and 1024-aberration case, respectively. Conclusions: Using one MR-ARFI image and noa priori information about the applied phase aberrations, the hybrid simulation-MR-ARFI technique improved the maximum MR-ARFI phase of the beam's focus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-CAMPUS-J-01: Acoustic Range Verification of Proton Beams: Simulation of Heterogeneity and Clinical Proton Pulses

Purpose: Through simulation, to assess acoustic-based range verification of proton beams (protoacoustics) under clinical conditions. Methods: Pressure waves generated by the energy deposition of a 150 MeV, 8 mm FWHM pulsed pencil proton beam were numerically simulated through two Methods: 1) For a homogeneous water medium, an analytical wave-equation solution was used to calculate the time-dependent pressure measured at detector points surrounding the proton Bragg peak. 2) For heterogeneity studies, a CT tissue image was used to calculate the proton dose deposition and define the acoustic properties of the voxels through which numerical pressure wave propagation was simulated with the k-Wave matlab toolbox. The simulations were used to assess the dependence of the acoustic amplitude and range-verification accuracy on proton pulse rise time and tissue heterogeneity. Results: As the proton pulse rise time is increased from 1 to 40 µs, the amplitude of the expected acoustic emission decreases (a 60% drop distal to the Bragg peak), the central frequency of the expected signal decreases (from 45 to 6 kHz), and the accuracy of the range-verification decreases (from <1 mm to 16 mm at 5 cm distal to the Bragg peak). For a 300 nA pulse, the expected pressure range is on the order of 0.1 Pa, which is observable with commercial detectors. For the heterogeneous medium, our test case shows that pressure waves emitted by an anterior pencil beam directed into the abdomen and detected posteriorly can determine the Bragg peak range to an accuracy of <2mm for a 1 µs proton pulse. Conclusion: For proton pulses with fast rise-times, protoacoustics is a promising potential method for monitoring penetration depth through heterogeneous tissue. The loss of range-verification accuracy with increasing rise-times, however, suggests the need for comparisons to modeling to improve accuracy for slower cyclotron proton sources.

07 ISOTOPE AND RADIATION SOURCES↗

Study of Particle Loss in Synchrotron Phase Space Injection for ESR Using Weak-Strong Beam-Beam Simulation with Nonlinear Lattice

In this report, we use tracking simulations to investigate synchrotron phase space injection for electron accumulation in the electron storage ring of the Electron Ion Collider. Our simulation model accounts for both beam-beam interactions and lattice nonlinearities. Specifically, we examine how particle loss is influenced by various parameters. Additionally, we conduct a theoretical analysis and derive an analytical formula for the rapid evaluation of particle loss. Our results demon strate the feasibility of synchrotron phase-space injection for the electron storage ring and provide insights to guide parameter selection for the design of the injection line.

43 PARTICLE ACCELERATORS↗

Explicit TE/TM scheme for particle beam simulations

In this paper we propose an explicit two-level conservative scheme based on a TE/TM like splitting of the field components in time. Its dispersion properties are adjusted to accelerator problems. It is simpler and faster than the implicit version [I. Zagorodnov, T. Weiland, TE/TM scheme for computation of electromagnetic fields in accelerators, J. Comput. Phys. 207 (2005) 69]. It does not have dispersion in the longitudinal direction and the dispersion properties in the transverse plane are improved. The explicit character of the new scheme allows a uniformly stable conformal method without iterations and the scheme can be parallelized easily. It assures energy and charge conservation. A version of this explicit scheme for rotationally symmetric structures is free from the progressive time step reducing for higher order azimuthal modes as it takes place for Yee's explicit method used in the most popular electrodynamics codes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam Beam Simulation Studies for NLC And SLC2000

We apply and modify the computer codes CAIN(P.Chen, G.Horton-Smith, T.Ohgaki, A.W.Weidemann, K.Yokoya, contributed to Workshop on Gamma-Gamma Colliders, Berkeley, CA, March 28-31, 1994; SLAC-PUB-6583.) and GUINEAPIG(D.Schulte (DESY), unpublished.) to make detailed studies of the beam-beam interaction in the SLAC design for a future linear collider (NLC), as well as to the proposed SLC2000 project. Using realistic beam distributions, we present simulations related to the tuning and optimization of luminosity in SLC2000 and NLC.

43 PARTICLE ACCELERATORS↗

Weak-strong Beam-beam Simulations for HL-LHC

In this paper we present dynamic aperture studies for possible High Luminosity LHC optics in the presence of beam-beam interactions, crab crossing schemes and magnets multipolar errors. Possible operational scenarios of luminosity leveling by transverse offset and betatron function are also studied and the impact on the beams stability is discussed.

43 PARTICLE ACCELERATORS↗

STUDY OF HARMONIC CRAB CAVITY IN EIC BEAM-BEAM SIMULATIONS

In the Electron-Ion Collider (EIC) design, crab cavities are adopted to compensate the geometric luminosity loss from the crossing angle. From previous studies, higher-order synchro-betatron resonances are excited since the hadron beam is long and the crossing angle is large. To reduce the luminosity degradation rate, different combinations of harmonic crab cavities are studied with both weak-strong and strong-strong simulation methods. The frequency map analysis (FMA) is also used for comparison. This study helps determine the crab cavity parameters for the future EIC.

43 PARTICLE ACCELERATORS↗

AN IMPLICIT"DRIFT-LORENTZ" PARTICLE MOVER FOR PLASMA AND BEAM SIMULATIONS

In order to efficiently perform particle simulations in systems with widely varying magnetization, we developed a drift-Lorentz mover, which interpolates between full particle dynamics and drift kinetics in such a way as to preserve a physically correct gyroradius and particle drifts for both large and small ratios of the timestep to the cyclotron period. In order to extend applicability of the mover to systems with plasma frequency exceeding the cyclotron frequency such as one may have with fully neutralized drift compression of a heavy-ion beam we have developed an implicit version of the mover. A first step in this direction, in which the polarization charge was added to the field solver, was described previously. Here we describe a fully implicit algorithm (which is analogous to the direct-implicit method for conventionalparticle-in-cell simulation), summarize a stability analysis of it, and describe several tests of the resultant code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Implicit "Drift-Lorentz" Particle Mover for Plasma and Beam Simulations

In order to efficiently perform particle simulations in systems with widely varying magnetization, we have developed a 'drift-Lorentz mover', which interpolates between full particle dynamics and drift kinetics in such a way as to preserve a physically correct gyroradius and particle drifts for both large and small ratios of the timestep to the cyclotron period. In order to extend applicability of the mover to systems with plasma frequency exceeding the cyclotron frequency - such as one may have with fully neutralized drift compression of a heavy ion beam - we have developed an implicit version of the mover. A first step in this direction, in which the polarization charge was added to the field solver, was described previously. Here we describe a fully implicit algorithm (which is analogous to the direct-implicit method for conventional particle-in-cell simulation), a stability analysis of it, its implementation in the WARP code, and several tests of the resultant code. The fully implemented version is electrostatic; we are beginning development of an electromagnetic version, and describe also the status of that effort.

43 PARTICLE ACCELERATORS↗

Challenges in simulating beam dynamics of dielectric laser acceleration

Dielectric Laser Acceleration (DLA) achieves the highest gradients among structure-based electron accelerators. The use of dielectrics increases the breakdown field limit, and thus the achievable gradient, by a factor of at least 10 in comparison to metals. Experimental demonstrations of DLA in 2013 led to the Accelerator on a Chip International Program (ACHIP), funded by the Gordon and Betty Moore Foundation. In ACHIP, our main goal is to build an accelerator on a silicon chip, which can accelerate electrons from below 100 keV to above 1 MeV with a gradient of at least 100 MeV/m. For stable acceleration on the chip, magnet-only focusing techniques are insufficient to compensate the strong acceleration defocusing. Thus, spatial harmonic and Alternating Phase Focusing (APF) laser-based focusing techniques have been developed. Additionally, we have developed the simplified symplectic tracking code DLAtrack6D, which makes use of the periodicity and applies only one kick per DLA cell, which is calculated by the Fourier coefficient of the synchronous spatial harmonic. Due to coupling, the Fourier coefficients of neighboring cells are not entirely independent and a field flatness optimization (similarly as in multi-cell cavities) needs to be performed. The simulation of the entire accelerator on a chip by a Particle In Cell (PIC) code is possible, but impractical for optimization purposes. Finally, we have also outlined the treatment of wake field effects in attosecond bunches in the grating within DLAtrack6D, where the wake function is computed by an external solver.

43 PARTICLE ACCELERATORS↗