Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in G4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages to this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Measurement of Telescope Transmission Using a Collimated Beam Projector

With the increasingly large number of Type Ia supernova being detected by current-generation survey telescopes, and even more expected with the upcoming Rubin Observatory Legacy Survey of Space and Time, the precision of cosmological measurements will become limited by systematic uncertainties in flux calibration rather than statistical noise. One major source of systematic error in determining SNe Ia color evolution (needed for distance estimation) is uncertainty in telescope transmission, both within and between surveys. We introduce here the Collimated Beam Projector (CBP), which is meant to measure a telescope transmission with collimated light. The collimated beam more closely mimics a stellar wave front as compared to flat-field-based instruments, allowing for more precise handling of systematic errors such as those from ghosting and filter angle-of-incidence dependence. As a proof of concept, we present CBP measurements of the StarDICE prototype telescope, achieving a standard (1σ) uncertainty of 3% on average over the full wavelength range measured with a single beam illumination.

79 ASTRONOMY AND ASTROPHYSICS↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

In situ transmission electron microscopy with dual ion beam irradiation and implantation

To study the helium effects and their interactions with displacement damage in irradiated materials, an in situ dual-ion beam irradiation capability with transmission electron microscopy was recently established at the IVEM-Tandem Facility at Argonne National Laboratory. Pure nickel was irradiated in situ individually with 1 MeV Kr ions for displacement damage study, 16 keV He ions for helium implantation, and simultaneously with 1 MeV Kr ions and 16 keV He ions at the rate of 1 at.% He/dpa to study the interaction of helium and displacement damage at 500 degrees C. Helium bubbles were formed and segregated within dislocation loops during the He implantation experiment and no bubbles were observed outside the loops. The loop size increased with increasing helium concentration. In contrast, helium bubbles were formed uniformly in the matrix when nickel was irradiated simultaneously with 1 MeV Kr ions and 16 keV He ions. Overall, it is suggested that the uniformly-distributed defect clusters formed under 1 MeV Kr ion irradiation serve as trapping sites of helium atoms resulting in homogeneous nucleation of helium bubbles under the dualion beam irradiation in nickel.

36 MATERIALS SCIENCE↗

Ultrafast time-resolved 2D imaging of laser-driven fast electron transport in solid density matter using an x-ray free electron laser

High-power, short-pulse laser-driven fast electrons can rapidly heat and ionize a high-density target before it hydrodynamically expands. The transport of such electrons within a solid target has been studied using two-dimensional (2D) imaging of electron-induced Kα radiation. However, it is currently limited to no or picosecond scale temporal resolutions. Here, we demonstrate femtosecond time-resolved 2D imaging of fast electron transport in a solid copper foil using the SACLA x-ray free electron laser (XFEL). An unfocused collimated x-ray beam produced transmission images with sub-micron and ~10 fs resolutions. The XFEL beam, tuned to its photon energy slightly above the Cu K-edge, enabled 2D imaging of transmission changes induced by electron isochoric heating. Time-resolved measurements obtained by varying the time delay between the x-ray probe and the optical laser show that the signature of the electron-heated region expands at ~25% of the speed of light in a picosecond duration. Time-integrated Cu Kα images support the electron energy and propagation distance observed with the transmission imaging. The x-ray near-edge transmission imaging with a tunable XFEL beam could be broadly applicable for imaging isochorically heated targets by laser-driven relativistic electrons, energetic protons, or an intense x-ray beam.

47 OTHER INSTRUMENTATION↗

Parallel Broadband Femtosecond Reflection Spectroscopy at a Soft X-Ray Free-Electron Laser

X-ray absorption spectroscopy (XAS) and the directly linked X-ray reflectivity near absorption edges yield a wealth of specific information on the electronic structure around the resonantly addressed element. Observing the dynamic response of complex materials to optical excitations in pump–probe experiments requires high sensitivity to small changes in the spectra which in turn necessitates the brilliance of free electron laser (FEL) pulses. However, due to the fluctuating spectral content of pulses generated by self-amplified spontaneous emission (SASE), FEL experiments often struggle to reach the full sensitivity and time-resolution that FELs can in principle enable. Here, we implement a setup which solves two common challenges in this type of spectroscopy using FELs: First, we achieve a high spectral resolution by using a spectrometer downstream of the sample instead of a monochromator upstream of the sample. Thus, the full FEL bandwidth contributes to the measurement at the same time, and the FEL pulse duration is not elongated by a monochromator. Second, the FEL beam is divided into identical copies by a transmission grating beam splitter so that two spectra from separate spots on the sample (or from the sample and known reference) can be recorded in-parallel with the same spectrometer, enabling a spectrally resolved intensity normalization of pulse fluctuations in pump–probe scenarios. We analyze the capabilities of this setup around the oxygen K- and nickel L-edges recorded with third harmonic radiation of the free electron laser in Hamburg (FLASH), demonstrating the capability for pump–probe measurements with sensitivity to reflectivity changes on the per mill level.

36 MATERIALS SCIENCE↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling for the phased injector upgrade for 12 GeV CEBAF

The upcoming Jefferson Lab K-Long experiment at Hall D will require unique beam conditions with a much lower bunch repetition rate and atypically high bunch charge. To optimize the Continuous Electron Beam Accelerator Facility (CEBAF) injector for this experiment, we performed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) to determine the magnetic elements and RF settings necessary for the K-long bunch charge (0.64 pC) at 200 kV. We also investigated the transmission and beam characteristics of low to high charge per bunch electron beams through the injector for simultaneous operations of all four CEBAF Halls and characterized the transmission as a function of the photocathode laser spot size and pulse length. Our findings provide valuable insights into optimizing the CEBAF injector for the Jefferson Lab K-Long experiment, as well as for other experiments with similar beam conditions

Kazimi, R.↗

Modeling the CEBAF Injector at 200 kV: Investigating K-Long Beam Conditions with and without Wien Filter

The upcoming K-Long experiment [1] ain Hall D at Jefferson Lab presents unique beam requirements, featuring a significantly low bunch repetition rate and an unusually high bunch charge. This experiment, which utilizes the CEBAF accelerator in conjunction with the GlueX experimental setup, aims to study strange hadron spectroscopy by measuring the differential cross section and polarizations of produced hyperons such as Λ, Σ, Ξ, and Ω. By directing an intense K-Long beam towards the LD2/LH2 target, new and valuable data can be obtained. To optimize the CEBAF injector specifically for this experiment, we employed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) simulations. Through this approach, we determined the optimal magnetic elements and radiofrequency (RF) settings required to achieve a K-Long bunch charge of 0.64 pC at an energy of 200 kV. We conducted simulations with both the Wien Filter turned on and off to examine its impact on the beam. Furthermore, we investigated the transmission efficiency and beam characteristics of electron beams with varying charge per bunch through the injector, considering the simultaneous operation of all four CEBAF Halls. The results of our study offer valuable insights and guidance for optimizing the CEBAF injector not only for the Jefferson Lab K-Long experiment but also for other experiments that entail similar beam conditions.

Pokharel, Sunil↗

Novel Focused Ion Beam Liftouts for Spatial Characterization of Spherical Biominerals With Transmission Electron Microscopy

Abstract Focused ion beam (FIB) is frequently used to prepare electron- and X-ray-beam-transparent thin sections of samples, called lamellae. Typically, lamellae are prepared from only a subregion of a sample. In this paper, we present a novel approach for FIB lamella preparation of microscopic samples, wherein the entire cross-section of the whole sample can be investigated. The approach was demonstrated using spherical, porous, and often hollow microprecipitates of biologically precipitated calcium carbonate. The microprecipitate morphology made these biogenic samples more fragile and challenging than materials commonly investigated using FIB lamellae. Our method enables the appropriate orientation of the lamellae required for further electron/X-ray analyses after attachment to the transmission electron microscopy (TEM) grid post and facilitates more secure adhesion onto the grid post. We present evidence of autofluorescence in bacterially precipitated vaterite using this lamella preparation method coupled with TEM selected area diffraction. This innovative approach allows studying biomineralization at the micro to nano scales, which can provide novel insights into bacterial responses to microenvironmental conditions.

47 OTHER INSTRUMENTATION↗

High-efficiency transmission-mode diamond scintillator for quantitative characterization of X-ray beams

The luminance of a transmission mode X-ray scintillator diamond plate is dominated by induced defect centers having an excited state lifetime less than 10 msec, and in embodiments less than 1 msec, 100 usec, 10 used, 1 used, 100 nsec, or even 50 nsec, thereby providing enhanced X-ray luminance response and an X-ray flux dynamic range that is linear with X-ray flux on a log-log scale over at least three orders of magnitude. The diamond plate can be a single crystal having a dislocation density of less than 104 per square centimeter, and having surfaces that are ion milled instead of mechanically polished. The defect centers can be SiV centers induced by silicon doping during CVD diamond formation, and/or NV0 centers formed by nitrogen doping followed by applying electron beam irradiation of the diamond plate and annealing.

Antipov, Sergey↗

Secure mmWave Spectrum Sharing with Autonomous Beam Scheduling for 5G and Beyond

Spectrum Sharing (SS) has seen a renewed set of initiatives in 5G with the availability of shared and unlicensed spectrum bands that can be used by multiple cellular service providers and private cellular networks. Beam based transmission, instead of the traditional sector based transmission in conjunction with the spectrum agility of the 5G New Radio (NR) has brought new opportunities to optimized sharing of spectrum. Currently in the U.S., a centralized Spectrum Access Server (SAS) is used to co-ordinate spectrum sharing among networks sharing the same spectrum band. However, SAS becomes a focal point for security attacks and a performance bottleneck. In addition, SAS relies on an Environmental Sensor Network (ESN), separate from the 5G network. Without trusted spectral occupancy information, false reporting of spectrum sensing data can create sub-optimal and unfair spectrum usage. This paper summarizes our recent research findings in using a decentralized scheme for multiple networks to securely share spectrum with autonomous beam scheduling : 1) A new stochastic network framework based on Lyapunov Optimization approach is developed to optimize scheduling at the base stations; 2) Game theoretic (GT) approach is used to formulate the distributed scheduler; 3) Another distributed scheduler with Q-learning is presented that utilizes the Reinforcement Learning (RL) approach; 4) The performance and convergence rate of these distributed solutions to use shared and unlicensed spectrum are compared with existing solutions. Conditions under which the performance of these schedulers approach the theoretical upper bound, which is the performance possible with no interference among the operators sharing the spectrum, are presented; 5) The ability of a base station to use its own user equipment as sensors, for optimal spectrum sharing with base stations in other operator networks, is demonstrated to be an effective approach.

5G↗

Degradation of a Cr-Mo steel by carbide precipitation over long-term service

Microstructure of the 40-year service-exposed 1Cr-0.5Mo steel extracted from pressure vessels through the boat sampling technique was characterized using x-ray diffraction, field-emission scanning electron microscopy, energy dispersive spectrometry, electron backscatter diffraction, focused ion beam, and transmission electron microscopy. The microstructure degradation during long-term service was identified. Statistical crystal plastic ity models were developed to correlate the microstructure and mechanical properties quantitatively. The steel is found significantly strengthened but slightly embrittled. Nanoscale Mo 2 C carbides have nucleated within the ferrite matrix over the long-term service, resulting in significant strengthening of the matrix. The coarser grain boundary Cr 23 C 6 carbides, on the other hand, act as the damage accumulation sites and lead to the degradation.

36 MATERIALS SCIENCE↗

Behavior and properties of helium cavities in ductile-phase-toughened tungsten irradiated with He + ions at an elevated temperature

Ductile-phase toughened tungsten (DPT W) composites have demonstrated a great potential for plasma-facing components in fusion power systems. These materials can retain the outstanding thermomechanical properties of W while significantly enhancing the fracture toughness. The DPT W composite in this study consists of W particles (88 wt.%) embedded in a ductile NiFeW (12 wt.%) solution matrix. Irradiation of the composite was performed with 90 keV He + ions to 1.0 × 10 17 He + /cm 2 at 973 K. The He cavities formed in both W and NiFeW phases are examined using convergent-beam scanning transmission electron microscopy (CB-STEM) at an atomic-level resolution. Full-range depth profiles of the He cavity diameters and number densities are analyzed. The results show that the average cavity diameter in NiFeW is ~2.7 times that in W, while the number density is an order of magnitude lower. A quantitative analysis of the He density and pressure in the cavities is also achieved using STEM electron energy loss spectroscopy (STEM-EELS) mapping. The He atoms in the cavities in NiFeW are found to be under-pressurized, while those in similar-sized cavities in W are not detectable. Further, the He energy-loss shift exhibits a linear relationship with the He density in cavities in NiFeW, with the slope comparable to that for martensitic steel.

36 MATERIALS SCIENCE↗

Self-Guiding of Long-Wave Infrared Laser Pulses Mediated by Avalanche Ionization

Nonlinear self-guided propagation of intense long-wave infrared (LWIR) laser pulses is of significant recent interest, as it promises high power transmission without beam breakup and multifilamentation. Central to self-guiding is the mechanism for the arrest of self-focusing collapse. Here, we show that discrete avalanche sites centered on submicron aerosols can arrest self-focusing, providing a new mechanism for self-guided propagation of moderate intensity LWIR pulses in outdoor environments. In this work, our conclusions are supported by simulations of LWIR pulse propagation using an effective index approach that incorporates the time-resolved plasma dynamics of discrete avalanche breakdown sites.

47 OTHER INSTRUMENTATION↗

High-temperature oxidation behavior of the SiC layer of TRISO particles in low-pressure oxygen

Surrogate tristructural-isotropic (TRISO)-coated fuel particles were oxidized in 0.2 kPa O 2 at 1200–1600°C to examine the behavior of the SiC layer and understand the mechanisms. The thickness and microstructure of the resultant SiO 2 layers were analyzed using scanning electron microscopy, focused ion beam, and transmission electron microscopy. The majority of the surface comprised smooth, amorphous SiO 2 with a constant thickness indicative of passive oxidation. The apparent activation energy for oxide growth was 188 ± 8 kJ/mol and consistent across all temperatures in 0.2 kPa O 2 . The relationship between activation energy and oxidation mechanism is discussed. Raised nodules of porous, crystalline SiO 2 were dispersed across the surface, suggesting that active oxidation and redeposition occurred in those locations. These nodules were correlated with clusters of nanocrystalline SiC grains, which may facilitate active oxidation. So these findings suggest that microstructural inhomogeneities such as irregular grain size influence the oxidation response of the SiC layer of TRISO particles and may influence their accident tolerance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ORNL Post-irradiation Examination (LAMDA) Final Report on Characterization of Irradiated Grade 92 Ferritic-Martensitic Steels

Irradiation effects on ferritic-martensitic steel Grade 92 were investigated in this project. Samples from two heats of Grade 92, i.e., G92-2b and NF616, were selected, which were irradiated in the High Flux Isotope Reactor (HFIR) and the Advanced Test Reactor (ATR), respectively. Samples from two heats of ferriticmartensitic steel T91, irradiated in the ATR, were also selected as references for the Grade 92 samples. The selected G92-2b samples were irradiated to 0.5–14.7 displacements per atom (dpa) at two temperature regimes: 400–497 °C and 683–720°C. The selection of the high irradiation temperatures up to ~720°C is to test the performance at such upper bound temperatures, which would provide insights for the upper bound applicable temperature for Grade 92. The selected NF616 and T91 samples were irradiated to 3–8.2 dpa at 292–448°C. Except for T91 heat2 samples in 3-mm diameter discs, all the other selected samples are of type SS-J2 miniature tensile specimens. Two Nuclear Science User Facilities (NSUF), i.e., the Irradiated Materials Examination and Testing (IMET) hot cell facility and the Low Activation Materials Design and Analysis (LAMDA) facility, were used in the Post-Irradiation Examination (PIE) activities for the selected samples, which include: Tensile tests at room temperature (IMET); Fractography of the tensile fracture surfaces (LAMDA: scanning electron microscopy and energy; dispersive spectroscopy); Vickers hardness measurements (LAMDA); and Microstructural characterization (LAMDA: electron backscatter diffraction, focused-ion beam, and transmission electron microscopy).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗