Search NASA⌕ Search

SEARCH · Search NASA

Results for “beamline automation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solution scattering at the Life Science X-ray Scattering (LiX) beamline

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q -range of typically 0.006–3.2 Å −1 . Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.

60 APPLIED LIFE SCIENCES↗

Tools for supporting solution scattering during the COVID-19 pandemic

During the COVID-19 pandemic, synchrotron beamlines were forced to limit user access. Performing routine measurements became a challenge. At the Life Science X-ray Scattering (LiX) beamline, new instrumentation and mail-in protocols have been developed to remove the access barrier to solution scattering measurements. Our efforts took advantage of existing instrumentation and coincided with the larger effort at NSLS-II to support remote measurements. Given the limited staff–user interaction for mail-in measurements, additional software tools have been developed to ensure data quality, to automate the adjustments in data processing, as users would otherwise rely on the experience of the beamline staff, and produce a summary of the initial assessments of the data. This report describes the details of these developments.

99 GENERAL AND MISCELLANEOUS↗

An Online Dynamic Amplitude-Correcting Gradient Estimation Technique to Align X-ray Focusing Optics

High-brightness X-ray pulses, as generated at synchrotrons and X-ray free electron lasers (XFELs), are used in a variety of scientific experiments. At these facilities, measurements often require optical equipment, e.g Compound Refractive Lenses (CRLs) to be precisely aligned and focused. The lateral alignment of CRLs to a beamline requires precise positioning along four axes: two translational, and the two rotational. At a synchrotron, alignment is often accomplished manually. However, XFEL beamlines present a beam brightness that fluctuates stochastically, making manual alignment a time-consuming endeavor. Automation using simplex or classic stochastic descent often fails, given the errant gradient estimates. Herein we present a dynamic-amplitude correction to the usual gradient based on the combination of a generalized finite difference stencil and a time-dependent sampling pattern. Intensity is recorded periodically, then used to normalize numerical derivatives against fluctuations. Error expectation is analyzed, and efficacy is demonstrated on classic benchmarks. We provide a proof of concept by laterally aligning optics on a simulated XFEL beamline using data recorded at both synchrotron and XFEL facilities.

97 MATHEMATICS AND COMPUTING↗

An automated liquid jet for fluorescence dosimetry and microsecond radiolytic labeling of proteins

X-ray radiolytic labeling uses broadband X-rays for in situ hydroxyl radical labeling to map protein interactions and conformation. High flux density beams are essential to overcome radical scavengers. However, conventional sample delivery environments, such as capillary flow, limit the use of a fully unattenuated focused broadband beam. An alternative is to use a liquid jet, and we have previously demonstrated that use of this form of sample delivery can increase labeling by tenfold at an unfocused X-ray source. Here we report the first use of a liquid jet for automated inline quantitative fluorescence dosage characterization and sample exposure at a high flux density microfocused synchrotron beamline. Our approach enables exposure times in single-digit microseconds while retaining a high level of side-chain labeling. This development significantly boosts the method’s overall effectiveness and efficiency, generates high-quality data, and opens up the arena for high throughput and ultrafast time-resolved in situ hydroxyl radical labeling.

59 BASIC BIOLOGICAL SCIENCES↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

hkl-projects/ioc-hkl

HKL-IOC is an open source EPICS IOC that performs real‑time crystallographic HKL calculations for diffractometers and scattering instruments. It integrates the Python hkl library with EPICS through PyDevice, exposing HKL calculations and diffractometer geometry transformations as standard EPICS process variables. This allows beamline and laboratory control systems to convert between motor positions and reciprocal‑space coordinates, configure diffractometer geometries, and drive scans directly in HKL space. The software is written in Python and designed to run alongside existing EPICS deployments without requiring changes to core EPICS components. It is intended for use at synchrotron and neutron scattering facilities, as well as laboratory X‑ray diffractometers, where reliable and reproducible HKL calculations are needed for experiment control, data collection, and automation. HKL-IOC is distributed under the GNU General Public License v3.0 (GPL‑3.0) and contributions and extensions for additional geometries and beamlines are welcomed.

Baekey, Alex↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Automated Disposal Debris Shield (ADDS) Test Stand, Version 2.0

One of the major refurbishing efforts mentioned in the National Ignition Facility (NIF) sustainability plan is improvements to prevent the debris generated during shots from reaching the high value optics. Addressing this issue will allow NIF to continue high powered shots while maintaining a manageable optic exchange rate. A major area of concern is right outside the Target Chamber in the Final Optics Assembly (FOA) where we have the Grating Debris Shield (GDS) being protected from target debris by the Automated Disposable Debris Shields (ADDS). The area that houses the ADDS will be referred to as the ADDS Doghouse. The schematic illustration of a single NIF beamline with the general area of the ADDS Doghouse outlined in red can be seen in Figure 1. Discovering methods to improve the ADDS Doghouse in preventing debris from passing through is top priority.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First measurement of electron neutrino scattering cross section on argon

We report the first electron neutrino cross section measurements on argon, based on data collected by the ArgoNeuT experiment running in the GeV-scale NuMI beamline at Fermilab. A flux-averaged $\nu_e + \overline{\nu}_e$ total and a lepton angle differential cross section are extracted using 13 $\nu_e$ and $\overline{\nu}_e$ events identified with fully-automated selection and reconstruction. We employ electromagnetic-induced shower characterization and analysis tools developed to identify $\nu_e/\overline{\nu}_e$-like events among complex interaction topologies present in ArgoNeuT data ($\langle E_{\bar{\nu}_e} \rangle = 4.3$ GeV and $\langle E_{\nu_e} \rangle = 10.5$ GeV). The techniques are widely applicable to searches for electron-flavor appearance at short- and long-baseline using liquid argon time projection chamber technology. Notably, the data-driven studies of GeV-scale $\nu_e/\overline{\nu}_e$ interactions presented in this Letter probe an energy regime relevant for future DUNE oscillation physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sample Code for "An automated approach to the alignment of compound refractive lenses"

This sample code is intended to be publicly released on DOECODE. It is an accompaniment to "n automated approach to the alignment of compoundrefractive lenses". It's two small, mostly self-contained scripts that include the complete details necessary to implement the to-be published article's algorithm at a scientific beamline.

Breckling, SeanR [Mission Support and Test Service↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operating advanced scientific instruments with AI agents that learn on the job

Advanced scientific user facilities, such as next generation X-ray light sources and self-driving laboratories, are revolutionizing scientific discovery by automating routine tasks and enabling rapid experimentation and characterizations. However, these facilities must continuously evolve to support new experimental workflows, adapt to diverse user projects, and meet growing demands for more intricate instruments and experiments. This continuous development introduces significant operational complexity, necessitating a focus on usability, reproducibility, and intuitive human-instrument interaction. In this work, we explore the integration of agentic AI, powered by Large Language Models (LLMs), as a transformative tool to achieve this goal. We present our approach to developing a human-in-the-loop pipeline for operating advanced instruments including an X-ray nanoprobe beamline and an autonomous robotic station dedicated to the design and characterization of materials. Specifically, we evaluate the potential of various LLMs as trainable scientific assistants for orchestrating complex, multi-task workflows, which also include multimodal data, optimizing their performance through optional human input and iterative learning. We demonstrate the ability of AI agents to bridge the gap between advanced automation and user-friendly operation, paving the way for more adaptable and intelligent scientific facilities.

Large Language Models↗

A Systems Engineering Analysis of National Ignition Facility Industrial Controls Systems and Safety Interlock Systems Remote Input/Output Networking Migration from ControlNet to EtherNet/IP

The ControlNet industrial communications protocol and modules used in the Industrial Control System (ICS) and Safety Interlock System (SIS) at the National Ignition Facility (NIF) are no longer necessary and the ICS and SIS would be better served by migrating the communications structure to use EtherNet/Industrial Protocol (IP) and EtherNet bridge modules instead. By the admission of the vendor of ControlNet hardware, Rockwell Automation, in literature by Bill Petro [1], “Moving forward, customers will be able to optimize their asset utilization better using EtherNet/IP protocol than with ControlNet.” The NIF is one of the key elements of the Inertial Confinement Fusion (ICF) program at Lawrence Livermore National Laboratory (LLNL), a federally funded research and development center (FFRDC). The NIF contains the systems and provides the operational capacity to perform ICF, high energy density (HED), and discovery science experiments utilizing 192 individual beamlines, a host of diagnostics, and all the industrial systems required to facilitate these beamlines and diagnostics. The industrial systems are governed by the ICS and SIS, with the ICS providing control and the SIS providing monitoring and permissives. Construction on the NIF began in 1997 and was certified complete in 2009 and, as a result, the ICS and SIS were developed during this time using the tools that were available then. This includes the communications structure and protocols for these systems, much of which was, and still is, ControlNet. ControlNet, particularly during the time that the ICS and SIS were being built, has several attractive features. ControlNet hardware is exclusive to Rockwell Automation, which was the automation hardware chosen for the ICS and SIS. One feature that could be considered an advantage or a disadvantage depending on the communication needs of the system is that ControlNet also utilizes no active network components, excluding repeaters which are not always necessary. According to the architect of the ICS system at the NIF, Gordon Lau, one of the most attractive features of the ControlNet protocol during development of the ICS and SIS was that it is deterministic, providing timing of data transfer that is executed exactly as it is defined by the developer.

42 ENGINEERING↗

Empowering Scientific Discovery Through Computing at the Advanced Photon Source

This paper explores the challenges and solutions for managing and processing the vast amount of data generated by the Advanced Photon Source (APS), a synchrotron light source facility producing ultra-bright x-rays for diverse scientific domains. With 68 experimental beamlines covering materials research, biology, and more, the APS serves a wide user base across academia, government, and industry. The ongoing upgrade of the APS storage ring and installation of new instruments will amplify data generation and processing demands. This paper discusses the approach to address these demands through automated data processing using standardized workflows that produce faster scientific insights. The APS Data Management System coordinates various data related tasks to manage storage, data transfer, metadata cataloging, data processing, and interfaces with tools provided by Globus. Through integration with the Argonne Leadership Computing Facility (ALCF), APS users can efficiently access high-performance computing resources. Standardized workflows have led to reduced computational burdens on scientists and greater accessibility of high performance computing resources. We demonstrate how standardization and collaboration enable scientists to rapidly convert raw data into meaningful scientific results, establishing a streamlined path from data collection to analysis and ultimately to publication.

Parraga, Hannah↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

LLM integration into EPICS

The utilization of large language models (LLMs) such as ChatGPT has seen a remarkable increase in various fields over the past few years. These models have demonstrated their versatility and capability in understanding and generating human-like text, making them invaluable tools in numerous applications. In this project, we explore the integration of a LLM into the Experimental Physics and Industrial Control System (EPICS). The primary focus of this integration is to employ the LLM for advanced image processing and spatial analysis on images obtained from the beamlines. By leveraging the capabilities of the LLM, we aim to enhance the accuracy and efficiency of image interpretation, enabling more precise data analysis and decision-making within the EPICS framework. This integration not only showcases the potential of LLMs in scientific and industrial applications but also sets the stage for future advancements in automated control systems.

Adams, Ethan↗

Enabling Real-time Scattering Data Analysis with Scalable Optimization [Slides]

Diffraction experiments produce datasets with rich multidimensional physics information such as microstructure, equations of state, crystal structure, elastoplastic properties, and other key inputs to LANL mission-essential multiphysics models. This information is typically extracted through a process called Rietveld refinement, which involves selecting appropriate models of the instrument, crystal structure, and microstructure, identifying suitable starting values, and then fitting often hundreds of model parameters using a sequence of empirical parameter turnon/off sequences within a non-global gradient-based optimization. Extensive user expertise is required to properly setup a refinement, identify appropriate models, and select initial parameter values close to truth, such that the refinement will yield parameter values that are optimally predictive. This is a very tedious manual process performed far after the beamline campaign has ended. As facilities have become capable of generating larger volumes of data, the limitation in throughput due to Rietveld refinement has led to a dramatic increase in unanalyzed data as opposed to an intended increase in new science. In our FY22 TED, we demonstrated an integrated toolset providing near real-time automated Rietveld analysis. If this toolset can be optimized to provide automated Rietveld analysis in real-time, this could alleviate the bottleneck in unanalyzed diffraction data, aid in decision-making during experiments, and increase efficiency of the facility.

74 ATOMIC AND MOLECULAR PHYSICS↗