Search NASA⌕ Search

SEARCH · Search NASA

Results for “beamsplitter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Over-under double-pass interferometer

An over-under double-pass interferometer in which the beamsplitter area and thickness can be reduced to conform only with optical flatness considerations is achieved by offsetting the optical center line of one cat's-eye retroreflector relative to the optical center line of the other in order that one split beam be folded into a plane distinct from the other folded split beam. The beamsplitter is made transparent in one area for a first folded beam to be passed to a mirror for doubling back and is made totally reflective in another area for the second folded beam to be reflected to a mirror for doubling back. The two beams thus doubled back are combined in the central, beam-splitting area of the beamsplitter and passed to a detector. This makes the beamsplitter insensitive to minimum-thickness requirements and selection of material.

Schindler, Rudolf A.↗

Proper time observables of general gravitational perturbations in laser interferometry-based gravitational wave detectors

We present an explicitly gauge-invariant observable of any general gravitational perturbation, ℎ 𝜇⁢𝜈 [not necessarily due to gravitational waves (GWs)], in a laser interferometry-based GW detector, identifying the signature as the proper time elapsed of the beamsplitter observer, between two events: when a photon passes through the beamsplitter, and when the same photon returns to the beamsplitter after traveling through the interferometer arm and reflecting off the far mirror. Our formalism applies to simple Michelson interferometers and can be generalized to more advanced setups. We demonstrate that the proper time observable for a plane GW is equivalent to the detector strain commonly used by the GW community, though now the common framework can be easily generalized for other types of signals, such as dark matter clumps or spacetime fluctuations from quantum gravity. We provide a simple recipe for computing the proper time observable for a general metric perturbation in linearized gravity and explicitly show that it is invariant under diffeomorphisms of the perturbation, as any physical observable should be.

Dark matter detectors↗

Over-under double-pass interferometer

An over-under double pass interferometer in which the beamsplitter area and thickness can be reduced to conform only with optical flatness considerations was achieved by offsetting the optical center line of one cat's-eye retroreflector relative to the optical center line of the other in order that one split beam be folded into a plane distinct from the other folded split beam. The beamsplitter is made transparent in one area for a first folded beam to be passed to a mirror for doubling back and is made totally reflective in another area for the second folded beam to be reflected to a mirror for doubling back. The two beams thus doubled back are combined in the central, beamsplitting area of the beamsplitting and passed to a detector. This makes the beamsplitter insensitive to minimum thickness requirements and selection of material.

Schindler, R. A.↗

Interferometer

An interferometer of relatively simple design which is tilt compensated, and which facilitates adjustment of the path lengths of split light beams is described. The interferometer includes a pair of plate-like elements with a dielectric coating and an oil film between them, that forms a beamsplitter interface, and with a pair of reflector surfaces at the ends of the plates. A pair of retroreflectors are positioned so that each split beam component is directed by a retroreflector onto one of the reflector surfaces and is then returned to the beamsplitter interface, so that the reflector surfaces tilt in a direction and amount that compensates for tilting of the beamsplitter interface.

Breckinridge, J. B.↗

Two complimentary methods for aligning linear arrays

Two approaches are presented for implementing a simple method for aligning the object and image planes of linear arrays of elemental detectors. Both variants begin by firing a laser beam into cubic beamsplitters which change the direction of the resulting parallel beams to one perpendicular to the array. A neutral density filter is located along the beam path and an optical microscope is located beyond the exit plane of the beamsplitters. In the first variant, the beam is tuned to the spectral sensitivity of the elements. In the second version, a lens and a microscope are situated outside the exit plane of the beamsplitters, and spectral tuning is unnecessary. Subsequent rotations of the array are shown to reveal the coincidence or lack of coincidence of the image plane and the linear array.

Finkel, Mitchell W.↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗

Optical considerations in infrared heterodyne spectrometer design

The optical design considerations for optimization of sensitivity, tunability, and versatility of an infrared heterodyne spectrometer are discussed using the GSFC CO2 laser heterodyne spectrometer optical front end as an example. Problems related to the coherent nature of the laser local oscillator beam (e.g., interference effects at edges of optical elements and at the beam combining beamsplitter) are described and proper beamsplitter design discussed. Optimum matching to the telescope is discussed. The severe effects of large central obscuration on the coherent telescope efficiency are described and steps to partially recover the lost system sensitivity are proposed. Measurements made with the GSFC 48 inch telescope (linear obscuration rate = 0.5) and the KPNO McMathe telescope (no obscuration) are given as examples.

Kostiuk, T.↗

Spectrophotovoltaic orbital power generation

A system with 1000 : 1 concentration ratio is defined, using a cassegrain telescope as the first stage concentration (270 x) and compound parabolic concentrators (CPC) for the second stage concentration of 4.7 x for each spectral band. Using reported state of the art (S.O.A.) solar cells device parameters and considering structural losses due to optics and beamsplitters, the efficiencies of one to four cell systems were calculated with efficiencies varying from approximately 22% to 30%. Taking into account cost of the optics, beamsplitter, radiator, and the cost of developing new cells the most cost effective system is the GaAs/Si system.

Knowles, G.↗

High speed multi focal plane optical system

An apparatus for eliminating beamsplitter generated optical aberrations in a pupil concentric optical system providing a plurality of spatially separated images on different focal planes or surfaces is presented. The system employs a buried surface beamsplitter having spherically curved entrance and exit faces which are concentric to a system aperture stop with the entrance face being located in the path of a converging light beam directed there from an image forming objective element which is also concentric to the aperture stop.

Minott, P. O.↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

VUV thin films, chapter 7

The application of thin film technology to the vacuum ultraviolet (VUV) wavelength region from 120 nm to 230 nm has not been fully exploited in the past because of absorption effects which complicate the accurate determination of the optical functions of dielectric materials. The problem therefore reduces to that of determining the real and imaginary parts of a complex optical function, namely the frequency dependent refractive index n and extinction coefficient k. We discuss techniques for the inverse retrieval of n and k for dielectric materials at VUV wavelengths from measurements of their reflectance and transmittance. Suitable substrate and film materials are identified for application in the VUV. Such applications include coatings for the fabrication of narrow and broadband filters and beamsplitters. The availability of such devices open the VUV regime to high resolution photometry, interferometry and polarimetry both for space based and laboratory applications. This chapter deals with the optics of absorbing multilayers, the determination of the optical functions for several useful materials, and the design of VUV multilayer stacks as applied to the design of narrow and broadband reflection and transmission filters and beamsplitters. Experimental techniques are discussed briefly, and several examples of the optical functions derived for selected materials are presented.

Zukic, Muamer↗

Alignment and Polarization Sensitivity Study for the Cassini-Composite InfraRed Spectrometer (CIRS) Far InfraRed (FIR) Interferometer

The Composite InfraRed Spectrometer (CIRS) instrument flying on the Cassini spacecraft to Saturn is a cryogenic spectrometer with far-infrared (FIR) and mid-infrared (MIR) channels. The CIRS FIR channel is a polarizing interferometer that contains three polarizing grid components. These components are an input polarizer, a polarizing beamsplitter, and an output polarizer/analyzer. They consist of a 1.5 micron thick mylar substrate with 2 gm wide copper wires, with 2 gm spacing (4 micron pitch) photolithographically deposited on the substrate. This paper details the polarization sensitivity studies performed on the output polarizer/analyzer, and the alignment sensitivity studies performed on the input polarizer and beamsplitter components in the FIR interferometer.

Crooke, Julie A.↗

Alignment and Polarization Sensitivity Study on the Cassini: CIRS FIR Interferometer

The Composite InfraRed Spectrometer (CIRS) instrument flying on the Cassini spacecraft to Saturn is a cryogenic spectrometer with far-infrared (FIR) and mid-infrared (MIR) channels. The CIRS FIR channel is a polarizing interferometer that contains three polarizing grid components. These components are an input polarizer, a polarizing beamsplitter, and an output polarizer/analyzer. They consist of a 1.5 micron thick mylar substrate with 2 microns wide copper wires, with 2 microns spacing (4 microns pitch) photolithographically deposited on the substrate. This paper details the alignment sensitivity studies performed on the polarizing beamsplitter, and the polarization sensitivity studies performed on all three polarizing components in the FIR interferometer.

Crooke, Julie↗

Real-time analysis keratometer

A computer assisted keratometer in which a fiducial line pattern reticle illuminated by CW or pulsed laser light is projected on a corneal surface through lenses, a prismoidal beamsplitter quarterwave plate, and objective optics. The reticle surface is curved as a conjugate of an ideal corneal curvature. The fiducial image reflected from the cornea undergoes a polarization shift through the quarterwave plate and beamsplitter whereby the projected and reflected beams are separated and directed orthogonally. The reflected beam fiducial pattern forms a moire pattern with a replica of the first recticle. This moire pattern contains transverse aberration due to differences in curvature between the cornea and the ideal corneal curvature. The moire pattern is analyzed in real time by computer which displays either the CW moire pattern or a pulsed mode analysis of the transverse aberration of the cornea under observation, in real time. With the eye focused on a plurality of fixation points in succession, a survey of the entire corneal topography is made and a contour map or three dimensional plot of the cornea can be made as a computer readout in addition to corneal radius and refractive power analysis.

Adachi, Iwao P.↗

Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors

Optical ranging is a problem of estimating the round-trip flight time of a phase- or amplitude-modulated optical beam that reflects off of a target. Frequency- modulated, continuous-wave (FMCW) ranging systems obtain this estimate by performing an interferometric measurement between a local frequency- modulated laser beam and a delayed copy returning from the target. The range estimate is formed by mixing the target-return field with the local reference field on a beamsplitter and detecting the resultant beat modulation. In conventional FMCW ranging, the source modulation is linear in instantaneous frequency, the reference-arm field has many more photons than the target-return field, and the time-of-flight estimate is generated by balanced difference- detection of the beamsplitter output, followed by a frequency-domain peak search. This work focused on determining the maximum-likelihood (ML) estimation algorithm when continuous-time photoncounting detectors are used. It is founded on a rigorous statistical characterization of the (random) photoelectron emission times as a function of the incident optical field, including the deleterious effects caused by dark current and dead time. These statistics enable derivation of the Cramér-Rao lower bound (CRB) on the accuracy of FMCW ranging, and derivation of the ML estimator, whose performance approaches this bound at high photon flux. The estimation algorithm was developed, and its optimality properties were shown in simulation. Experimental data show that it performs better than the conventional estimation algorithms used. The demonstrated improvement is a factor of 1.414 over frequency-domainbased estimation. If the target interrogating photons and the local reference field photons are costed equally, the optimal allocation of photons between these two arms is to have them equally distributed. This is different than the state of the art, in which the local field is stronger than the target return. The optimal processing of the photocurrent processes at the outputs of the two detectors is to perform log-matched filtering followed by a summation and peak detection. This implies that neither difference detection, nor Fourier-domain peak detection, which are the staples of the state-of-the-art systems, is optimal when a weak local oscillator is employed.

Erkmen, Baris I.↗

Optical vector receiver operating near the quantum limit

An optical receiver concept or binary signals with performance approaching the quantum limit at low average signal background photons has been devised by Dolinar, however this receiver requires ideal optical combining and complicated real-time shaping of the local field, hence tends to be difficult to implement at high data rates. A simpler nulling receiver that approaches the quantum limit without complex optical processing, suitable for high-rate operation has been suggested earlier by Kennedy. Here we formulate a vector receiver concept that incorporates the Kennedy receiver together with a physical beamsplitter, but also utilizes the reflected signal component to improve signal detection. It is found that augmenting the Kennedy receiver with classical coherent detection at the auxiliary beamsplitter output, and optimally processing the vector observations, always improves on the performance of the Kennedy receiver alone, significantly so at low average photon rates. This is precisely the region of operation where modern codes approach channel capacity. It is also shown that the addition of background radiation has little effect on the performance of the coherent receiver component, suggesting a viable approach for near quantum-limited performance in high background environments

Lau, Chi-Wung↗

Laser absorptivity measurement device

A laser absorptivity measurement device uses a linearly polarized incident beam, an optical configuration comprising an internal polarizing beamsplitter that transmits the linearly polarized incident beam and a quarter-wave plate that converts linearly polarized incident beam into a circularly polarized incident beam that is reflected off a processing substrate. The quarter-wave plate and polarizing beamsplitter can then direct the reflected light back into an integrating volume, where the power of the reflected light can be measured by a photodetector. The laser absorptivity measurement device is capable of making real-time absorption efficiency measurements of a variety of laser-based processes, including laser welding and brazing, additive manufacturing, and laser marking.

Tung, Daniel↗