Qualitative numerical study of simultaneous high-G-intensified gas–solids contact, separation and segregation in a bi-disperse rotating fluidized bed in a vortex chamber
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Rotating fluidized beds provide a unique opportunity to exploit fluidization under higher particle forces. The centripetal force in a rotating fluid bed is typically on the order of 10 times the force of gravity. Since the force keeping the particles in the unit is larger, the drag force can also be larger, allowing for higher gas and slip velocities. This operating regime provides intensified gas-solids contact through higher mass transfer, heat transfer, gas throughput, and bubble suppression. One application for using a rotating fluidized bed is in Chemical Looping Combustion (CLC). When solid fuels are used, oxygen carrier and ash are mixed in the process. In order to maintain high carbon capture efficiencies and recyclability of the oxygen carrier, the ash needs to be separated from the oxygen carrier. This separation can be done aerodynamically since the oxygen carrier is larger and heavier than the ash. It is theorized that rotating fluidized beds could improve both the gas-solid and solid-solid separation process efficiency and throughput as compared to conventional fluidized beds. A 43 cm diameter, 2.5 cm long vortex chamber has been designed and constructed to investigate the application to particle separation. A series of experiments have been performed to investigate the separation of different binary mixtures of solids. These experiments demonstrate the use of a rotating fluidized bed for high-G intensified particle separation that can be combined with high-G intensified gas-solids contact and gas-solids separation.¼
The fluidization behavior of Geldart B particles in micro fluidized beds is investigated numerically using Computational Fluid Dynamics coupled with Discrete Element Method (CFD-DEM) available in the open-source Multiphase Flow with Interphase eXchanges (MFIX) code. The effects of different bed inner diameters (D) of 8 mm, 12 mm, 16 mm and various initial static bed heights (H) were examined. It is found that both decreasing the column diameter and increasing the bed height in a micro fluidized bed increases the minimum fluidization velocity (Umf). The observed overshoot in pressure drop that occurs before the onset of fluidization decreases in magnitude with increasing column diameter, however there is less sensitivity to bed height. Overall, the numerical results agree qualitatively with existing theoretical correlations and experimental studies. The simulations show that both column diameter and particle-wall friction contribute to the variation in minimum fluidization velocity. Finally, these two factors are coupled and hard to separate. The detailed influences of wall friction on minimum fluidization velocity are then investigated for a prescribed column diameter of 8 mm by varying the wall friction from 0 to 0.4.
Not Available
In this work, we show that a freshly sedimented granular bed settles and creeps forward over extended periods of time under an applied hydrodynamic shear stress which is below the critical value for bedload transport. The rearrangements are found to last over a timescale which is millions of times the sedimentation timescale of a grain in the fluid. Compaction occurs uniformly throughout the bed, but creep is observed to decay exponentially with depth and decreases over time. The granular volume fraction in the bed is found to increase logarithmically, saturating at the random close packing value Φ rcp ≈ 0.64, while the surface roughness is observed to remain essentially unchanged. We demonstrate that an increasingly higher shear stress is required to erode the bed, after a subcritical shear is applied, which results in an increase in its volume fraction. Thus, we find that bed armoring occurs due to a deep shear-induced relaxation of the bed toward the volume fraction associated with the glass transition.
A review of literature associated with Pebble Bed and Particle Bed reactor core research has revealed a systemic problem inherent to reactor core concepts which utilize randomized rather than structured coolant channel flow paths. For both the Pebble Bed and Particle Bed Reactor designs; case studies reveal that for indeterminate reasons, regions within the core would suffer from excessive heating leading to thermal runaway and localized fuel melting. A thermal Computational Fluid Dynamics model was utilized to verify that In both the Pebble Bed and Particle Bed Reactor concepts randomized coolant channel pathways combined with localized high temperature regions would work together to resist the flow of coolant diverting it away from where it is needed the most to cooler less resistive pathways where it is needed the least. In other words given the choice via randomized coolant pathways the reactor coolant will take the path of least resistance, and hot zones offer the highest resistance. Having identified the relationship between randomized coolant channel pathways and localized fuel melting it is now safe to assume that other reactor concepts that utilize randomized coolant pathways such as the foam core reactor are also susceptible to this phenomenon.
A moving bed gasification/thermal treatment reactor includes a geometry in which moving bed reactor particles serve as both a moving bed filter and a heat carrier to provide thermal energy for thermal treatment reactions, such that the moving bed filter and the heat carrier are one and the same to remove solid particulates or droplets generated by thermal treatment processes or injected into the moving bed filter from other sources.
Utilizing pyrolysis chars as the injection fuel in a blast furnace can reduce the dependence on high-quality pulverized coal injection (PCI) coal. In this study, the physical properties and reaction characteristics of chars prepared from two different industrial-scale pyrolyzers (fluidized bed and moving bed) are investigated. The results reveal remarkable component segregation in the char particles with different particle sizes. The properties of large-size char particles are found to better satisfy the PCI fuel requirement in a blast furnace. Compared with PCI coal, the char particles exhibit a rough surface, well-developed pore structure, and less-ordered chemical structure of carbon. Results from isothermal combustion, isothermal gasification, and drop tube furnace experiments show that both types of chars exhibit a better reactivity than PCI coal. The excellent reactivity of chars is closely related to its high Brunauer–Emmett–Teller surface area and relatively poor chemical ordering during conversion. Based on these characteristics, both fluidized bed char (FBC) and moving bed char (MBC) have a great potential to be used as PCI fuels. The application method of chars for PCI in a blast furnace is proposed finally.
Penetration of solar photovoltaic (PV) installations into the grid has increased in recent years. In the past, photovoltaic installations have not included grid-support functionality. Grid support functions including Volt-VAR (VVAR), Frequency-Watt (FW), Volt-Watt (VW), frequency/voltage-ride through, as well as other inverter functions such as anti-islanding are recommended by standards such as IEEE 1547 to allow PV inverters to contribute to acceptable operation and stability of distribution systems with high penetrations of PV and to ensure predictable response of the PV inverters. First, low-level and high-level grid support inverter control functions were developed and tested in simulation. The developed controller is able to integrate advanced controller functions in a coordinated approach, avoiding any conflict between the different control objectives. The algorithms were then programmed on an off-the-shelf embedded controller that included a dual-core CPU and FPGA. The details of the high-level grid support function and the lower level switching control will be presented. Second, this programmed controller is tested using a controller-hardware-in-the-loop (CHIL) test bed setup using an FPGA-based real-time simulator. The CHIL setup has the capability to run at a 500 nano-second time-step to accommodate the 20 kHz switching frequency of the developed controller. The advanced control function and CHIL test bed details provided here will aide future researchers to design, implement, and test advanced inverter functions for PV inverters.
Dual-sorbent systems are proposed for radioiodine management with a regenerated primary bed for multiple cycles of use in complex conditions and a secondary bed for disposal with higher waste loadings. Sorbent approaches for the effective capture of gaseous radioiodine (isotopes 129 I and 131 I) produced from a range of nuclear processes have been studied for over half a century. (1−5) Whether or not a sorbent (e.g., molecular sieve) is required to physically screen/trap or chemically bind a radionuclide of interest through chemisorption, the complexity of the gas stream has a large impact on the performance (e.g., loading capacity, selectivity) and active life of a sorbent bed. (3) Silver mordenite (AgZ), the U.S. Department of Energy baseline sorbent for radioiodine capture from nuclear processes, performs well within acidic conditions and at elevated temperatures (6) and can be consolidated into a chemically durable waste form for long-term disposal. (7,8) However, new sorbents are being sought because optimal capture performance of AgZ significantly decreases in dynamic oxidizing environments with competing species, and it is expensive and it contains Ag (a toxic metal). (9) Until a new sorbent is found to replace AgZ, the regeneration and reuse of AgZ is an attractive alternative to a single-use primary sorbent bed. In this regard, a primary sorbent could be designed for enhanced capture in complex gas streams and the ability to be regenerated for reuse. Here, a secondary sorbent could then be tailored for maximum iodine loading in the gas stream and chemical durability within a disposal facility.
The proposition for molten salt and high-temperature gas-cooled reactors has increased the focus on the dynamics and physics in randomly packed pebble beds. Research is being conducted on the validity of these designs as a possible contestant for the fourth-generation nuclear power systems. A detailed understanding of the coolant flow behavior is required in order to ensure proper cooling of the reactor core during normal and accident conditions. In order to increase the understanding of the flow through these complex geometries and enhance the accuracy of lower-fidelity modeling, high-fidelity approaches such as direct numerical simulation (DNS) can be utilized. Nek5000, a spectral-element computational fluid dynamics (CFD) code, was used to develop DNS fluid flow data. The flow domain consisted of 147 pebbles enclosed by a bounding wall. In the work presented, the Reynolds numbers ranged from 430 to 1050 based on the pebble diameter and inlet velocity. Characteristics of the flow domain such as volume averaged porosity, axial porosity, and radial porosity were studied and compared with correlations available in the literature. Friction factors from the DNS results for all Reynolds numbers were compared with correlations in the literature. The first- and second-order statistics show good agreement with the available experimental data. Turbulence length scales were analyzed in the flow. Reynolds stress anisotropy was characterized by utilizing invariant analysis. Overall, the results of the analysis in this study provide deeper understanding of the flow behavior and the effect of the wall in packed beds.
This assessment is based on readily available literature and discusses both Newtonian and non-Newtonian slurries with respect to sliding beds and erosion due to sliding beds. This report does not quantify the size of the sliding beds or erosion rates due to sliding beds, but only assesses if they could be present. This assessment addresses process pipelines in the Pretreatment (PT) facility and the high level waste (HLW) transfer lines leaving the PT facility to the HLW vitrification facility concentrate receipt vessel.
Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (Umf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.
Chemical looping with oxygen uncoupling (CLOU) is a promising carbon capture technology that utilizes two interconnected fluidized-bed reactors to separate oxygen from air using a metal oxide, and then to use that oxygen to combust fuel in a nitrogen-free environment. CLOU is particularly well suited for solid fuels such as coal since released O 2 will readily combust with solid char. This study presents simulations of the University of Utah's dual fluidized bed chemical looping process development unit (PDU) operating as a CLOU system at 100 kW th , using CPFD Software's Barracuda-VR™ CFD modeling program. A full 3D model of the PDU was used including both reactors, as well as loop seals and cyclone separators. Hydrodynamic settings and the drag model are based on previous cold-flow validation experiments. Mechanisms describing CLOU reaction kinetics for cuprous oxide oxidation in the air reactor and cupric oxide reduction in the fuel reactor were adapted from previously completed experimental work. Coal char kinetics were based on the carbon-hydrogen-nitrogen-oxygen-sulfur, CHNOS, method. Submodels for devolatilization, gasification, and homogenous gas-phase reactions used relationships from the literature. Results predict volatile burnout almost immediately, though coal combustion continues into the upper portions of the fuel reactor and cyclone. Lastly, nitrogen gas leakage into the fuel reactor is shown to be mostly carryover from the air reactor
In this study, a method of producing velocity profile maps from electrical capacitance volume tomography (ECVT) measurements by reconstructing displacement from measured changes in capacitance is developed and applied to fluidized bed systems. The mapping of the reconstruction leverages the gradient of the sensitivity distribution of the ECVT sensor to circumvent the need for image cross correlation techniques. Experimental data of both bubbling and slugging fluidized beds are collected in a cold flow model. Adaptation of the technique is discussed in detail, and velocity profiles are obtained for a range of gas flow rates. The produced velocity maps are compared against the established methods of cross correlation and against empirical correlations from the literature and are found to agree well in tracking slug and bubble velocity. The exception is when the tracked object is large relative to the ECVT sensor dimensions, a scenario that can be avoided through proper sensor design. The quantities of average velocity, momentum, and solid and gas volume fraction are derived from the image and velocity profiles. The results demonstrate and extend the power of ECVT as a measurement tool for the study and monitoring of gas–solid fluidized beds by providing a computationally cheaper alternative to 3-D cross correlation for deriving velocity profiles.
In this paper, the limitations of axisymmetric and Cartesian two-dimensional (2D) simulations of cylindrical gas-solid fluidized beds are discussed. A new method has been proposed to carry out pseudo-two-dimensional (2.5D) simulations of a cylindrical fluidized bed by appropriately combining computational domains of Cartesian 2D and axisymmetric simulations. The proposed method was implemented in the open-source code MFIX and applied to the simulation of a lab-scale bubbling fluidized bed with necessary sensitivity study. After a careful grid study to ensure the numerical results are grid independent, detailed comparisons of the flow hydrodynamics were presented against axisymmetric and Cartesian 2D simulations. Furthermore, the 2.5D simulation results have been compared to the three-dimensional (3D) simulation for evaluation. This new approach yields better agreement with the 3D simulation results than with axisymmetric and Cartesian 2D simulations.