Search NASA⌕ Search

SEARCH · Search NASA

Results for “benchmark dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Implementation and verification of PyNE R2S with DAG-OpenMC

The mesh-based Rigorous-Two-Step (R2S) method has been widely used in the accurate estimation of the shutdown dose rate (SDR) of fusion systems. Several mesh-based R2S code has been implemented based on Monte Carlo particle transport code MCNP5 or DAG-MCNP5 and inventory calculation code such as FISPACT-II, ALARA or ACAB. Recently, the OpenMC, a community-developed Monte Carlo particle transport code, implemented the photon particle transport capability, which enables OpenMC to be used in R2S. In this paper, PyNE R2S is extended with the support of DAG-OpenMC, i.e., OpenMC with DAGMC. Modifications that allow PyNE to read the flux result in the state point file of OpenMC has been implemented to PyNE R2S workflow. A custom source routine of OpenMC that reads the photon source file from PyNE R2S and sampling photon particle in OpenMC photon transport has been implemented in OpenMC. With these modifications, PyNE R2S is now capable of performing R2S calculations with both DAG-MCNP5 and DAG-OpenMC. The ITER FNG dose rate benchmark problem has been used to validate the code. The FNG neutron source has been modified for neutron transport with DAG-OpenMC. The shutdown dose rate of 19 cooling times has been calculated and compared with the experimental data and the computational results of other R2S codes. The results of PyNE R2S with DAG-OpenMC show satisfactory agreement with the experimental data and other computational results. Therefore, we consider PyNE R2S with DAG-OpenMC is a reliable code to calculate the SDR of fusion systems.

fusion↗

Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. In this study, results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computing material volume fractions on a superimposed mesh as applied to Monte Carlo particle transport simulations

Here, we present a newly implemented ray tracing algorithm in OpenMC for efficiently computing material volume fractions on superimposed meshes in complex geometries. By firing rays along each coordinate direction through the geometry, the approach accumulates track-length data in each mesh element, thereby determining the fractional composition of each material. Scaling studies on three different models—a random tetrahedra configuration, the Frascati Neutron Generator ITER dose rate benchmark, and a stellarator design—show excellent parallel performance, with nearly linear speedup on modern multi-threaded and distributed-memory systems. An analysis of the residual error relative to high-resolution reference solutions demonstrated that under optimal conditions it decreases as 1/R, where R is the number of rays fired, making it straightforward to achieve user-prescribed accuracy. This new functionality enables practical, mesh-based approaches for detailed nuclear analyses in production Monte Carlo workflows without resorting to expensive, fully conformal or unstructured meshing.

Monte Carlo↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation of the D1S Methodology for Shutdown Dose Rate Calculations in the OpenMC Monte Carlo Particle Transport Code

We present an implementation of the direct one-step (D1S) methodology for shutdown dose rate (SDR) calculations in the OpenMC Monte Carlo particle transport code. In addition to being the first fully open-source D1S implementation, it is also the first to require no ad hoc source code or nuclear data library modifications. The code can seamlessly switch between production of prompt and decay photons based on a user input parameter, and the decay data needed for decay photon generation are made available through a depletion chain file, which is already used for OpenMC’s built-in depletion/activation solver. A set of Python functions significantly eases the burden of computing and applying time correction factors needed to properly account for the time dependence of radionuclide activity. To assess the accuracy of the D1S implementation, SDR calculations have been carried out for three problems: a prism of iron irradiated by 14-MeV neutrons, the ITER port plug computational benchmark, and the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For each of these problems, comparisons were made to calculations using the rigorous two-step (R2S) method. The results on the iron prism problem illustrate how the D1S method achieves superior spatial resolution compared to the R2S method without the need for spatial discretization of the activation regions. The D1S and R2S results for the ITER port plug benchmark agree well with previously reported results in the literature. While the D1S results are 10% to 15% lower than the R2S results, this may be due to stochastic uncertainty and/or spatial discretization in the R2S calculations. On the FNG dose rate benchmark problem, the D1S method produces dose rate estimates that are within 4% of the dose rates predicted using a cell-based R2S workflow. The D1S estimates of the SDR are also in reasonable agreement with the experimental measurements and show the same basic trends that have been observed in previous works. A qualitative analysis of the execution time and uncertainty for the R2S and D1S workflows suggests that the D1S method would attain a higher figure of merit.

D1S method↗

Comparison of residual dose rates from MARS and DORIAN simulations with experimental data from the SINBAD database

This benchmarking study aims to compare residual dose rate predictions from the MARS and DORIAN codes with experimental measurements taken from samples irradiated at CERN's CERF facility. The research evaluates the residual dose rates of these samples over varied cooling intervals. Additionally, it delves into the influence of parameter choices, such as specific physics processes and energy thresholds, on the production and transport of particles and their effects on simulation outcomes. While both MARS and DORIAN largely align with experimental findings, discrepancies were observed in the copper sample. This prompted an in-depth examination of the elevated dose rates from MARS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark solutions for the galactic ion transport equations: Energy and spatially dependent problems

Nontrivial benchmark solutions are developed for the galactic ion transport (GIT) equations in the straight-ahead approximation. These equations are used to predict potential radiation hazards in the upper atmosphere and in space. Two levels of difficulty are considered: (1) energy independent, and (2) spatially independent. The analysis emphasizes analytical methods never before applied to the GIT equations. Most of the representations derived have been numerically implemented and compared to more approximate calculations. Accurate ion fluxes are obtained (3 to 5 digits) for nontrivial sources. For monoenergetic beams, both accurate doses and fluxes are found. The benchmarks presented are useful in assessing the accuracy of transport algorithms designed to accommodate more complex radiation protection problems. In addition, these solutions can provide fast and accurate assessments of relatively simple shield configurations.

Ganapol, Barry D.↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Space Weathering Experiments on Spacecraft Materials

A project to investigate space environment effects on specific materials with interest to remote sensing was initiated in 2016. The goal of the project is to better characterize changes in the optical properties of polymers found in multi-layered spacecraft insulation (MLI) induced by electron bombardment. Previous analysis shows that chemical bonds break and potentially reform when exposed to high energy electrons like those seen in orbit. These chemical changes have been shown to alter a material's optical reflectance, among other material properties. This paper presents the initial experimental results of MLI materials exposed to various fluences of high energy electrons, designed to simulate a portion of the geosynchronous Earth orbit (GEO) space environment. It is shown that the spectral reflectance of some of the tested materials changes as a function of electron dose. These results provide an experimental benchmark for analysis of aging effects on satellite systems which can be used to improve remote sensing and space situational awareness. They also provide preliminary analysis on those materials that are most likely to comprise the high area-to-mass ratio (HAMR) population of space debris in the geosynchronous orbit environment. Finally, the results presented in this paper serve as a proof of concept for simulated environmental aging of spacecraft polymers that should lead to more experiments using a larger subset of spacecraft materials.

Engelhart, D. P.↗

Verification of RESRAD-BUILD Code Version 4

This report documents the verification of the RESRAD-BUILD code, Version 4.0, which was released on December 22, 2022. Two earlier reports verifying Versions 3.0 and 3.1, respectively, were published in 2001 (Kamboj, et al. 2001) and 2003 (Tetra Tech NUS 2003). Version 4.0 of the RESRAD-BUILD code has many new features and modeling enhancements over the earlier versions, including the previously released Version 3.5. Chapter 2 of this report focuses on verifying the external dose and risk modeling for point, line, area, and volume sources, as well as for floor deposition. Besides verification, the external radiation doses calculated by RESRAD-BUILD were also benchmarked with those calculated by the MCNP code (Briemeister 1993). Section J.3 of the RESRAD-BUILD User’s Manual Vol. 1 (Yu et al. 2022) documents the results of that benchmarking effort. Chapter 3 of this report focuses on verifying the ventilation modeling, from checking the remaining source inventory, releases of radionuclides to the air, air concentrations and deposited floor concentrations over time, to the radiation dose and risk associated with inhalation, ingestion, and air submersion, with and without vacuuming. The verification efforts involve designing spreadsheets to perform calculations the same as or like those performed by the RESRAD-BUILD code and then comparing the spreadsheet results with those produced by the code. When the results agree or the differences are within acceptable range, the accuracy of model implementation in the code is verified. In addition to model implementation, the implementation of key functions and features that facilitate the modeling or the use of the code were also verified during the release testing of the code. Appendix A presents the test cases developed for these verification testing, and Appendix B presents the testing results that verify proper implementation of key functions and features.

54 ENVIRONMENTAL SCIENCES↗

Review of Experimental Data for Validating Computer Codes Used in Shielding Calculations for Spent Fuel Storage and Transportation Systems

This report presents a review of available radiochemical assay data and shielding benchmarks applicable to spent nuclear fuel (SNF) shielding calculations. The relevant information reviewed herein includes the Spent Fuel Composition (SFCOMPO) database, the Shielding Integral Benchmark Archive and Database (SINBAD), the International Handbook of Evaluated Criticality Safety Benchmark Experiments, and published measurements of external dose rates of casks loaded with SNF. The relevant experimental data identified in this report may be used to support verification and validation of computer codes used in SNF cask/transport shielding applications, as well as development of calculation uncertainties. It should be noted that a relatively small subset of the identified experimental data (e.g., criticality alarm experiments) is available in a standard format established by the international community participating in experimental isotopic and shielding data evaluations. An effort of the SFCOMPO Technical Review Group (TRG) is underway to publish first isotopic evaluations of individual assay data using a standard data evaluation format. The SINBAD TRG has recently initiated benchmark evaluations and modernization of the database. Therefore, more relevant information is expected in the future that will enable users to select quality experimental data in depletion code and shielding code validations for SNF applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Digital twins and deep learning segmentation of defects in monolayer MX 2 phases

Developing methods to understand and control defect formation in nanomaterials offers a promising route for materials discovery. Monolayer MX 2 phases represent a particularly compelling case for defect engineering of nanomaterials due to the large variability in their physical properties as different defects are introduced into their structure. However, effective identification and quantification of defects remain a challenge even as high-throughput scanning transmission electron microscopy methods improve. This study highlights the benefits of employing first principles calculations to produce digital twins for training deep learning segmentation models for defect identification in monolayer MX 2 phases. Around 600 defect structures were obtained using density functional theory calculations, with each monolayer MX 2 structure being subjected to multislice simulations for the purpose of generating the digital twins. Several deep learning segmentation architectures were trained on this dataset, and their performances evaluated under a variety of conditions such as recognizing defects in the presence of unidentified impurities, beam damage, grain boundaries, and with reduced image quality from low electron doses. Further, this digital twin approach allows benchmarking different deep learning architectures on a theory dataset, which enables the study of defect classification under a broad array of finely controlled conditions. It thus opens the door to resolving the underpinning physical reasons for model shortcomings and potentially chart paths forward for automated discovery of materials defect phases in experiments.

36 MATERIALS SCIENCE↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Deciphering decomposition pathways of high explosives with cryogenic X-ray Raman spectroscopy

We employed cryogenic X-ray Raman spectroscopy to investigate the early-stage decomposition of the high explosive molecule hexanitrohexaazaisowurtzitane (CL-20). By systematically varying the radiation dose under cryogenic conditions, we induced the decomposition of the molecule using ionizing radiation and observed the evolution of spectral features at the carbon, nitrogen, and oxygen K edges. Through extensive first-principles calculations, we identified key intermediates in the early stages of the decomposition process, resulting from C–C and C–N bond cleavage which leads to the opening of the internal cage structure. A detailed analysis of spectral trends and fingerprints provided evidence supporting N–NO 2 homolytic cleavage as the primary initial decomposition pathway. The combination of advanced core-level spectroscopy methods and state-of-the-art theoretical calculations enabled a comprehensive characterization of the molecular changes induced by controlled radiation dose exposures. In conclusion, our findings establish a benchmark for understanding the decomposition chemistry of high-explosive materials, offering important insights into their stability and reactivity under extreme conditions.

X-ray Raman spectroscopy↗

Experiments for SINBAD: Evaluation of Oak Ridge Health Physics Research Reactor Operation Data for CAAS Benchmark Creation [Slides]

This report was a real information preservation and dissemination work with a lot of legacy content that was found and used. There was an abundance of uncertainty, discrepancy, and contradictory information. Yet, a detailed, functional SCALE model was built, and the benchmark created is useful for shielding and CAAs validation work. Sulfur fluence C/E ratios are large (2 to 5), so different benchmark metrics were studied. Neutron fluence, element 57 dose, and other dosimetry responses at 3 meters C/E ratios are below 1.5 for bare and steel configurations. Additional promising metrics as dose per unit fluence and steel shield attenuation were computed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Feasibility of a multigroup Boltzmann–Fokker–Planck solution for electron beam dose calculations

Legacy nuclear-reactor Boltzmann solvers start clinical deployment as an alternative to Monte Carlo (MC) codes and Fermi–Eyges semiemprical models in radiation oncology treatment planning. Today’s certified clinical solvers are limited to photon beams. In this paper, ELECTR, a state-of-the-art multigroup electron cross sections generation module in NJOY is presented and validated against Lockwood’s calorimetric measurements, EGS-nrc and GEANT-4 for 1–20 MeV unidirectional electron beams. The nuclear-reactor DRAGON-5 solver is upgraded to access the library and solve the Boltzmann–Fokker–Planck (BFP) equation. A variety of heterogeneous radiotherapy and radiosurgery phantom configurations were used for validation purpose. Case studies include a thorax benchmark, that of a typical breast Intra-Operative Radiotherapy and a high-heterogeneity patient-like benchmark. For all beams, 100% of the water voxels satisfied the American Association of Physicists in Medicine accuracy criterion for a BFP-MC dose error below 2%. At least, 97.0% of adipose, muscle, bone, lung, tumor and breast voxels satisfied the 2% criterion. The average BFP-MC relative error was about 0.56% for all voxels, beams and materials combined. By irradiating homogeneous slabs from Z = 1 (hydrogen) to Z = 99 (einsteinium), we reported performance and defects of the CEPXS mode [US. Sandia National Lab., SAND-89-1685] in ELECTR for the entire periodic table. For all Lockwood’s benchmarks, NJOY-DRAGON dose predictions are within the experimental data precision for 98% of voxels.

42 ENGINEERING↗