Search NASA⌕ Search

SEARCH · Search NASA

Results for “beta counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method

The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested a method using commercial sorbents containing Aliquat ® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137 Cs removal step. The method was initially tested on SRS tank waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FY2018 Report on Fission Chamber Development at LANL

This report provides a description of a subset of FY18 activities conducted by Los Alamos National Laboratory (LANL) as part of the Nuclear Physics: Cumulative Fission Product Yields (Fission R-values) task of the NA-22 sponsored F2016 Venture Project. Specifically, this report describes the design, fabrication and testing of the Mark II fission chamber that was fielded as part of fission R-value measurements on the Flattop critical assembly located at the National Criticality Experiments Research Center (NCERC). Historically, fission product R-value measurements were performed by chemical separation and beta counting of samples from carefully controlled fission chamber experiments. These measurements form the basis for reporting data used in debris diagnostics and subsequent modeling. It was also the means to extract absolute cumulative fission product yields (yield per fission or $Y_i/f$ for the $i_{th}$ fission product) that are included in the international nuclear data libraries, and ultimately used in diagnostic evaluations and device modeling. The challenge for this effort was to design a functional fission chamber given the harsh neutron and gamma fields and severe space limitations of the Flattop critical assembly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission-product decay studies with the FRIB Decay Station

The Facility for Rare Isotopes Beams (FRIB) will be the flagship facility in low-energy nuclear physics when it comes online in 2022. This U.S. Department of Energy Office of Science user facility will open up a multitude of new opportunities to study exotic nuclei and will lead to new discoveries in nuclear structure, nuclear astrophysics, fundamental symmetries, and isotopes of importance to nuclear applications. The b-decay properties of neutron-rich isotopes will be measured with the FRIB Decay Station, a sophisticated state-of-the-art modular multi-detector system envisioned to perform b, g, n, and charged-particle spectroscopy. In this feasibility study, we use nuclear decay data collected with the FRIB Decay Station precursor, the Beta-Counting Station, currently used at Michigan State University with a radioactive beam produced at the National Superconducting Cyclotron Laboratory to identify the FRIB Decay Station capabilities for future measurements of neutron-rich exotic nuclei at FRIB to help provide a path forward for future measurements of interest to the lab’s mission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission Product Chain Yield Measurements [Slides]

Fission product chain yields were historically determined by chemical separation and beta counting of fissile samples irradiated in carefully controlled fission chamber experiments. These measurements provided the means to extract absolute fission product yields (yield per fission, or Y $\mathcal{i}$ /$\mathcal{f}$ for the $\mathcal{i}$ $\mathcal{th}$ fission product) that are included in the international nuclear data libraries, and ultimately used to model and characterize multiplying systems. However, reevaluations conducted at Los Alamos National Lab and Lawrence Livermore National Lab in 2005-2009 for neutron-induced fission of 235 U and 239 Pu highlighted disagreement among many of the measurements. This led to several new, targeted experimental programs to resolve these disagreements. In this presentation we will highlight recent efforts to address these discrepancies using energy-integral measurements at the National Criticality Experiments Research Center (NCERC) and outline our plans to complete the work over the next several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropy of the neutron fluence from a plasma focus.

The fluence of neutrons from a plasma focus was measured by gamma spectrometry of an activated silver target. This method results in a significant increase in accuracy over the beta-counting method. Multiple detectors were used in order to measure the anisotropy of the fluence of neutrons. The fluence was found to be concentrated in a cone with a half-angle of 30 deg about the axis, and to drop off rapidly outside of this cone; the anisotropy was found to depend upon the total yield of neutrons. This dependence was strongest on the axis. Neither the axial concentration of the fluence of neutrons nor its dependence on the total yield of neutrons is explained by any of the currently proposed models. Some other explanations, including the possibility of an axially distributed source, are considered.

Lee, J. H.↗

Tritium release and trapping in austenitic stainless steels: Role of microstructure and desorption anneal

The behavior of hydrogen and its isotopes in materials is a major concern in future nuclear systems both for the predictive analysis of the role of H, D, T in the environmental degradation of structural materials, for the confinement and inventory of tritium, and for the management of tritiated wastes. This study is focused on the characterization of the effect of the alloy microstructure, of desorption anneal and of oxide films on the tritium behavior (desorption kinetics, trapping, residual concentration) in various austenitic stainless steels. Different techniques (high temperature extraction of hydrogen, beta counting of tritium in massive samples) were used to study: the tritium absorption and desorption in several stainless steels, the role of the annealing conditions (temperature/time) on the tritium residual concentration and desorption flow, and the role of microstructural defects and of oxide films on the diffusion and trapping of tritium. (authors)

36 MATERIALS SCIENCE↗

Local Power Impact Experiment Design for a New Fuel Type for use in the Advanced Test Reactor

The Advanced Test Reactor (ATR), and complimentary zero-power ATR Critical (ATRC) reactor, located at Idaho National Labs (INL), are undergoing conversion from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU). Both have a variety of testing locations that can receive large variations in flux due to its unique serpentine design, consisting of five lobes (see Figure 1). Initial criticality and power distribution throughout the core are controlled by core-external outer shim control cylinders (OSCCs). Distinct test loops allow for testing at specific temperatures, pressures, and irradiation conditions. The ATR is one of the key nuclear engineering research and testing facilities within the DOE National Laboratory Complex, and the ATRC supports its operation [1]. Currently, the Office of Material Management and Minimization (M3) within the National Nuclear Security Administration of the DOE is working to convert the remaining research reactors, including the ATR, from 93% HEU fuel to 19.75% LEU fuel (LEU) to support non-proliferation [2]. Extensive materials testing at INL and internationally has demonstrated that a high-density uranium molybdenum (U 10Mo) alloy can meet the performance requirements of the remaining high powered research reactors. However, there are many technical challenges to address before the conversion to LEU can be successful, including the accurate characterization of the reactor core physics with LEU fuel. Reactor physics safety evaluations currently use Monte Carlo for the 21st Century (MC21), a continuous-energy Monte Carlo radiation transport code [3]. Existing MC21 models of the ATR and ATRC cores have a validation basis for use in neutronics analyses with HEU fuel. The models are used to support safety analyses that include comparisons to the safety requirements for the reactors. However, the use of the LOWE element in the ATR and ATRC is not currently covered by the current model validation basis. To deploy the new fuel type, extensive computational reactor physics support is necessary to support the use of LOWE in the ATR and ATRC. Therefore, LOWE requires a rigorous validation basis, aligned with that of HEU fuel, that takes advantage of the existing software tools and processes currently used for the ATR and ATRC. The experiment to validate of the MC21 models for determining power, the Power Impact Validation Experiment, will consist of two flux runs in the ATRC, one with fully HEU loading and one with a single LOWE element. Both flux runs will be instrumented with 20 sets of azimuthal fission wires and 3 sets of axial fission wires, as shown in Figure 4. Standard flux run methodology will be used [4]. Power Impact Validation Experiment data will be compared against MC21 calculated data, both for absolute fission rate accuracy and to determine the relative change in fission rates between the two runs. The results of the Power Impact Validation Experiment and subsequent evaluations will provide the validation basis for MC21 for use with LOWE elements. Key features of the Power Impact Validation Experiment include: (1) Two flux runs to allow for LOWE perturbed measurements to be compared to already validated measurements taken from a full core of HEU fuel, (2) Optimization of instrumentation to balance analytical needs with practical considerations (e.g., limited time window to count beta particles from fission products), and (3) Standard ATRC core loading, including both driver positions and flux traps, to minimize cost while remaining representative of typical ATR core loading.

42 ENGINEERING↗

Direct determination of lead-210 by liquid-scintillation counting

Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

Fairman, W. D.↗

International inter-comparison exercise on $${}^{153}\hbox {Sm}$$153Sm

Samarium-153 ( 153 Sm) is one of the many isotopes of interest to the nuclear forensics community. This short-lived radionuclide decays to stable europium-153 via beta emission, with subsequent de-excitation via gamma emission and internal conversion. Historical measurements of 153 Sm by gamma spectrometry and beta liquid scintillation counting have shown a low bias compared to beta proportional counting. In order to investigate this, four national laboratories jointly conducted an experimental inter-comparison exercise on a certified 153Sm sample, created from neutron activation of samarium-152. Radiometric measurements were conducted using gamma spectrometry, liquid scintillation, gas proportional counting, and passivated implanted planar silicon detectors and compared across the four institutions against the certificate. The results from this experiment are presented together with a number of conclusions which suggest that the current published cumulative fission yield for 153 Sm, as used by many laboratories, is approximately 15% high and is the likely cause of the previously observed historical bias.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An experiment to verify that the weak interactions satisfy the strong equivalence principle

The construction of a clock based on the beta decay process is proposed to test for any violations by the weak interaction of the strong equivalence principle bu determining whether the weak interaction coupling constant beta is spatially constant or whether it is a function of gravitational potential (U). The clock can be constructed by simply counting the beta disintegrations of some suitable source. The total number of counts are to be taken a measure of elapsed time. The accuracy of the clock is limited by the statistical fluctuations in the number of counts, N, which is equal to the square root of N. Increasing N gives a corresponding increase in accuracy. A source based on the electron capture process can be used so as to avoid low energy electron discrimination problems. Solid state and gaseous detectors are being considered. While the accuracy of this type of beta decay clock is much less than clocks based on the electromagnetic interaction, there is a corresponding lack of knowledge of the behavior of beta as a function of gravitational potential. No predictions from nonmetric theories as to variations in beta are available as yet, but they may occur at the U/sg C level.

Eby, P. B.↗

The {sup 150}Nd({sup 3}He,t) and {sup 150}Sm(t,{sup 3}He) reactions with applications to {beta}{beta} decay of {sup 150}Nd

The {sup 150}Nd({sup 3}He,t) reaction at 140 MeV/u and {sup 150}Sm(t,{sup 3}He) reaction at 115 MeV/u were measured, populating excited states in {sup 150}Pm. The transitions studied populate intermediate states of importance for the (neutrinoless) {beta}{beta} decay of {sup 150}Nd to {sup 150}Sm. Monopole and dipole contributions to the measured excitation-energy spectra were extracted by using multipole decomposition analyses. The experimental results were compared with theoretical calculations obtained within the framework of the quasiparticle random-phase approximation, which is one of the main methods employed for estimating the half-life of the neutrinoless {beta}{beta} decay (0{nu}{beta}{beta}) of {sup 150}Nd. The present results thus provide useful information on the neutrino responses for evaluating the 0{nu}{beta}{beta} and 2{nu}{beta}{beta} matrix elements. The 2{nu}{beta}{beta} matrix element calculated from the Gamow-Teller transitions through the lowest 1{sup +} state in the intermediate nucleus is maximally about half that deduced from the half-life measured in 2{nu}{beta}{beta} direct counting experiments, and at least several transitions through 1{sup +} intermediate states in {sup 150}Pm are required to explain the 2{nu}{beta}{beta} half-life. Because Gamow-Teller transitions in the {sup 150}Sm(t,{sup 3}He) experiment are strongly Pauli blocked, the extraction of Gamow-Teller strengths was complicated by the excitation of the 2({h_bar}/2{pi}){omega}, {Delta}L=0, {Delta}S=1 isovector spin-flip giant monopole resonance (IVSGMR). However, the near absence of Gamow-Teller transition strength made it possible to cleanly identify this resonance, and the strength observed is consistent with the full exhaustion of the non-energy-weighted sum rule for the IVSGMR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NATALIE: A 32 detector integrated acquisition system to characterize laser produced energetic particles with nuclear techniques

We present a stand-alone system to characterize the high-energy particles emitted in the interaction of ultrahigh intensity laser pulses with matter. According to the laser and target characteristics, electrons or protons are produced with energies higher than a few mega electron volts. Selected material samples can, therefore, be activated via nuclear reactions. A multidetector, named NATALIE, has been developed to count the {beta}{sup +} activity of these irradiated samples. The coincidence technique used, designed in an integrated system, results in very low background in the data, which is required for low activity measurements. It, therefore, allows a good precision on the nuclear activation yields of the produced radionuclides. The system allows high counting rates and online correction of the dead time. It also provides, online, a quick control of the experiment. Geant4 simulations are used at different steps of the data analysis to deduce, from the measured activities, the energy and angular distributions of the laser-induced particle beams. Two applications are presented to illustrate the characterization of electrons and protons.

43 PARTICLE ACCELERATORS↗

Measurement and reduction of low-level radon background in the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next generation, model independent, large scale experiment to determine the mass of the electron anti-neutrino by investigating the kinematics of tritium beta decay with a sensitivity of 200 meV/c{sup 2}. The measurement setup consists of a high luminosity windowless gaseous molecular tritium source (WGTS), a differential and cryogenic pumped electron transport and tritium retention section, a tandem spectrometer section (pre-spectrometer and main spectrometer) for energy analysis, followed by a detector system for counting transmitted beta decay electrons. Measurements performed at the KATRIN pre-spectrometer test setup showed that the decay of radon (Rn) atoms in the volume of the KATRIN spectrometers is a major background source. Rn atoms from low-level radon emanation of materials inside the vacuum region of the KATRIN spectrometers are able to penetrate deep into the magnetic flux tube so that the alpha decay of Rn contributes to the background. Of particular importance are electrons emitted in processes accompanying the Rn alpha decay, such as shake-off, internal conversion of excited levels in the Rn daughter atoms and Auger electrons. Lowenergy electrons (< 100 eV) directly contribute to the background in the signal region. High-energy electrons can be stored magnetically inside the volume of the spectrometer and are able to create thousands of secondary electrons via subsequent ionization processes with residual gas molecules. In order to reduce the Rn induced background different active and passive counter measures were developed and tested. This proceeding will give an overview on Rn sources within the KATRIN spectrometer, describes how Rn decays inside the spectrometer produce background events at the detector and presents different counter measures to reduce the Rn induced background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVALUATION OF AN UPWARD TREND IN BACKGROUND COUNT RATES FROM A STACK PARTICULATE CONTINUOUS AIR MONITOR

The Pacific Northwest National Laboratory (PNNL) operates the Radiochemical Processing Laboratory (RPL), which is a multi-purpose, non-reactor nuclear research facility. Regulations require both continuous sampling and monitoring of radioactive particulates and tritium gas in the exhaust from the main stack. Releases of other radioactive gases, including planned releases of radon, are tracked separately in a database and reported. During the 2015 calibration of the RPL stack continuous air monitor (CAM), measured alpha and beta background count rates were much higher than expected, especially when compared to count rates from previous calibrations. The source of the higher background count rates was examined by trending of historical CAM measurements and a comparison to the sampler data. The analysis revealed that the sample results showed no increase in emissions, whereas the CAM showed a steady increase in count rates. Ultimately, the CAM filter was analyzed and found to contain higher-than-normal background levels of 220Rn progeny. Assessments were performed to determine the cause of the increased background values, including reviews of building research activities, radioactive material usage and storage, adequacy of procedures, and the potential for internal CAM contamination. Project reviews determined that a research activity involving 228Th was left in a semi-stored state, resulting in 220Rn being released from a hot cell into the exhaust system. The 228Th source material was subsequently repackaged and contained resulting in a decrease of CAM background count rates. An estimate of the 220Rn release was made and the contribution to the annual offsite dose from the facility was calculated. The released activity and reported dose results were well below the permit limits for the facility.

radon, 220Rn, environmental assessment, air monito↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The use of lichen (Canoparmelia texana) as biomonitor of atmospheric deposition of natural radionuclides from U-238 and Th-232 series

Lichens have been used in studies of environmental pollution monitoring of various air pollutants, especially heavy metals. This paper aims to study the possibility of using this specimen for the assessment of radionuclides deposition in the vicinity of a nuclear research institute, Instituto de Pesquisas Energeticas e Nucleares (IPEN) located in Sao Paulo, Brazil. This Institute has as major activity to perform research in the field of the nuclear fuel cycle, and therefore deals with considerable amounts of natural radionuclides of the U and Th series. The activity of the naturally occurring radionuclides U-238, Ra-226, Ra-226 and Pb-210 was determined in samples of lichen (Canoparmelia texana) and soil collected at IPEN campus. The concentrations of Ra-228, Ra-226 and Pb-210 were determined by measuring alpha and beta gross counting in a gas flow proportional detector; U and Th were determined by neutron activation analysis. The values obtained varied from 164 Bq/kg to 864 Bq/kg, 13 Bq/kg to 50 Bq/kg, and from 287 Bq/kg to 730 Bq/kg for Ra-228, Ra-226 and Pb-210 respectively. For natural U and Th the values obtained varied from 1.2 Bq/kg to 162 Bq/kg and 1.84 Bq/kg to 5.17 Bq/kg respectively. The results obtained so far suggest that the Canoparmelia texana can be used as radionuclide monitor in the vicinity of nuclear installations.

54 ENVIRONMENTAL SCIENCES↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗