Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sandia Injury Biomechanics Laboratory Library

The Sandia Injury Biomechanics Laboratory (SIBL) Library is a collection of scripts and tools used to preprocess, process, and postprocess data for analysis of injury biomechanics data. SAND2020-3663 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hovey, Chad↗

Sensitivity of a Subject-specific Ankle Sprain Simulation to Extrinsic Versus Intrinsic Biomechanical Factors

Ankle sprains are the most common musculoskeletal injury in sport and military activity, despite existing prophylactic strategies. The purpose of this report was to develop a probabilistic simulation of lateral ankle sprains during single-limb drop landing, towards accelerating innovation in ankle sprain prevention. A deterministic, subject-specific musculoskeletal model was extended with automation and probabilistic distributions on sprain-related biomechanical factors. Probabilistic simulations were generated using traditional Monte Carlo techniques and the advanced mean value method, a more computationally-efficient approach. Predicted distributions of peak ankle joint rotations, velocities, and moments borne by supporting passive structures agreed favorably with the deterministic model and with reports of real sprain biomechanics. Parameter sensitivities identified that predictions were most strongly influenced by drop height, subtalar joint posture at contact, invertor/evertor co-activation, and passive ankle stiffness. The advanced mean value method predicted confidence bounds comparable to a 1000-trial Monte Carlo simulation, and required only 14 model evaluations and 4-min processing time. The extended probabilistic simulation may be useful to virtually test new prophylactic strategies for ankle sprains, and is made available for open-source use (https://simtk.org/projects/sprain-sim).

60 APPLIED LIFE SCIENCES↗

Development of biomechanical models for human factors evaluations

Previewing human capabilities in a computer-aided engineering mode has assisted greatly in planning well-designed systems without the cost and time involved in mockups and engineering models. To date, the computer models have focused on such variables as field of view, accessibility and fit, and reach envelopes. Program outputs have matured from simple static pictures to animations viewable from any eyepoint. However, while kinematics models are available, there are few biomechanical models available for estimating strength and motion patterns. Those, such as Crew Chief, that are available are based on strength measurements taken in specific positions. Johnson Space Center is pursuing a biomechanical model which will use strength data collected on single joints at two or three velocities to attempt to predict compound motions of several joint simultaneously and the resulting force at the end effector. Two lines of research are coming together to produce this result. One is an attempt to use optimal control theory to predict joint motion in complex motions, and another is the development of graphical representation of human capabilities. The progress to date in this research is described.

Woolford, Barbara↗

An overview of Space Shuttle anthropometry and biomechanics research with emphasis on STS/Mir recumbent seat system design

The Anthropometry and Biomechanics Laboratory (ABL) at JSC conducts multi-disciplinary research focusing on maximizing astronaut intravehicular (IVA) and extravehicular (EVA) capabilities to provide the most effective work conditions for manned space flight and exploration missions. Biomechanics involves the measurement and modeling of the strength characteristics of the human body. Current research for the Space Shuttle Program includes the measurement of torque wrench capability during weightlessness, optimization of foot restraint, and hand hold placement, measurements of the strength and dexterity of the pressure gloved hand to improve glove design, quantification of the ability to move and manipulate heavy masses (6672 N or 1500 lb) in weightlessness, and verification of the capability of EVA crewmembers to perform Hubble Space Telescope repair tasks. Anthropometry is the measurement and modeling of the dimensions of the human body. Current research for the Space Shuttle Program includes the measurement of 14 anthropometric parameters of every astronaut candidate, identification of EVA finger entrapment hazards by measuring the dimensions of the gloved hand, definition of flight deck reach envelopes during launch and landing accelerations, and measurement of anthropometric design parameters for the recumbent seat system required for the Shuttle/Mir mission (STS-71, Spacelab M) scheduled for Jun. 1995.

Klute, Glenn K.↗

A Biomechanical Approach to Assessing Hip Fracture Risk

Bone loss in microgravity is well documented, but it is difficult to quantify how declines in bone mineral density (BMD) contribute to an astronaut's overall risk of fracture upon return. This study uses a biomechanical approach to assessing hip fracture risk, or Factor of Risk (Phi), which is defined as the ratio of applied load to bone strength. All long-duration NASA astronauts from Expeditions 1-18 were included in this study (n=25), while crewmembers who flew twice (n=2) were treated as separate subjects. Bone strength was estimated based on an empirical relationship between areal BMD at the hip, as measured by DXA, and failure load, as determined by mechanical testing of cadaver femora. Fall load during a sideways fall was calculated from a previously developed biomechanical model, which takes into account body weight, height, gender, and soft tissue thickness overlying the lateral aspect of the hip that serves to attenuate the impact force. While no statistical analyses have been performed yet, preliminary results show that males in this population have a higher FOR than females, with a post- flight Phi of 0.87 and 0.36, respectively. FOR increases 5.1% from preflight to postflight, while only one subject crossed the fracture "threshold" of Phi = 1, for a total of 2 subjects with a postflight Phi > 1. These results suggest that men may be at greater risk for hip fracture due largely in part to their relatively thin soft tissue padding as compared to women, since soft tissue thickness has the highest correlation (R(exp 2)= .53) with FOR of all subject-specific parameters. Future work will investigate changes in FOR during recovery to see if baseline risk levels are restored upon return to 1-g activity. While dual x-ray absorptiometry (DXA) is the most commonly used clinical measure of bone health, it fails to provide compartment-specific information that is useful in assessing changes to bone quality as a result of microgravity exposure. Peripheral quantitative computed tomography (pQCT) accomplishes this by imaging transverse "slices" of the long bones. This project was a re-analysis of a 90 day bed rest study to determine if changes to cortical and trabecular compartments could be detected in the distal tibia with statistical significance using a new pQCT image analysis method. Nearly all changes in bone mineral density (BMD) and cross sectional area (CSA) measures were seen with statistical significance, with the exception of a change in cortical BMD. Total bone CSA increased by 1.1 % (p =0.01), cortical CSA decreased by - 5.6% (p<0.001) and trabecular CSA increased by 1.76% (p=0.007); the combination of which suggests bone resorption occurred at the endocortical surface in response to mechanical unloading by bed rest. Furthermore, total BMD and trabecular BMD decreased (-3.8%, p=0.001 and -2.8%, p =0.007, respectively), while decreases in cortical BMD failed to reach significance (-1.2%, p=0.07). Given that compartment-specific changes are seen with significance and are likely to influence bone strength, it is recommended that pQCT remain a standard measure used in bed rest because it provides a unique measure by which to better evaluate the efficacy of countermeasures to microgravity-induced bone loss.

Ellman, Rachel↗

Biomechanics of the Treadmill Locomotion on the International Space Station

Exercise prescriptions completed by International Space Station (ISS) crewmembers are typically based upon evidence obtained during ground-based investigations, with the assumption that the results of long-term training in weightlessness will be similar to that attained in normal gravity. Coupled with this supposition are the assumptions that exercise motions and external loading are also similar between gravitational environments. Normal control of locomotion is dependent upon learning patterns of muscular activation and requires continual monitoring of internal and external sensory input [1]. Internal sensory input includes signals that may be dependent on or independent of gravity. Bernstein hypothesized that movement strategy planning and execution must include the consideration of segmental weights and inertia [2]. Studies of arm movements in microgravity showed that individuals tend to make errors but that compensation strategies result in adaptations, suggesting that control mechanisms must include peripheral information [3-5]. To date, however, there have been no studies examining a gross motor activity such as running in weightlessness other than using microgravity analogs [6-8]. The objective of this evaluation was to collect biomechanical data from crewmembers during treadmill exercise before and during flight. The goal was to determine locomotive biomechanics similarities and differences between normal and weightless environments. The data will be used to optimize future exercise prescriptions. This project addresses the Critical Path Roadmap risks 1 (Accelerated Bone Loss and Fracture Risk) and 11 (Reduced Muscle Mass, Strength, and Endurance). Data were collected from 7 crewmembers before flight and during their ISS missions. Before launch, crewmembers performed a single data collection session at the NASA Johnson Space Center. Three-dimensional motion capture data were collected for 30 s at speeds ranging from 1.5 to 9.5 mph in 0.5 mph increments with a 12-camera system. During flight, each crewmember completed up to 6 data collection sessions spread across their missions, performing their normal exercise prescription for the test day, resulting in varying data collection protocols between sessions. Motion data were collected by a single HD video camera positioned to view the crewmembers' left side, and tape markers were placed on their feet, legs, and neck on specific landmarks. Before data collection, the crewmembers calibrated the video camera. Video data were collected during the entire exercise session at 30 Hz. Kinematic data were used to determine left leg hip, knee, and ankle range of motion and contact time, flight time, and stride time for each stride. 129 trials in weightlessness were analyzed. Mean time-normalized strides were found for each trial, and cross-correlation procedures were used to examine the strength and direction of relationships between segment movement pattern timing in each gravitational condition. Cross-correlation analyses between gravitational conditions revealed highly consistent movement patterns at each joint. Peak correlation coefficients occurred at 0% phase, indicating there were no lags in movement timing. Joint ranges of motion were similar between gravitational conditions, with some slight differences between subjects. Motion patterns in weightlessness were highly consistent at a given speed with those occurring in 1G, indicating that despite differing sensory input, subjects maintain running kinematics. The data suggest that individuals are capable of compensating for loss of limb weight when creating movement strategies. These results have important implications for creating training programs for use in weightlessness as practitioners can have greater confidence in running motions transferring across gravitational environments. Furthermore, these results have implications for use by researchers investigating motor control mechanisms and investigating hypotheses related to movement strategies when using sensory input that is dependent upon gravity.

DeWitt, John↗

Supplementing biomechanical modeling with EMG analysis

It is well established that astronauts experience musculoskeletal deconditioning when exposed to microgravity environments for long periods of time. Spaceflight exercise is used to counteract these effects, and the Advanced Resistive Exercise Device (ARED) on the International Space Station (ISS) has been effective in minimizing musculoskeletal losses. However, the exercise devices of the new exploration vehicles will have requirements of limited mass, power and volume. Because of these limitations, there is a concern that the exercise devices will not be as effective as ARED in maintaining astronaut performance. Therefore, biomechanical modeling is being performed to provide insight on whether the small Multi-Purpose Crew Vehicle (MPCV) device, which utilizes a single-strap design, will provide sufficient physiological loading to maintain musculoskeletal performance. Electromyography (EMG) data are used to supplement the biomechanical model results and to explore differences in muscle activation patterns during exercises using different loading configurations.

electromyography↗

Influence of Load Profile on Biomechanics of the Squat and Deadlift

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to counteract the effect reduced gravity has on the body. Astronauts will exercise on a flywheel based device on the second Orion Exploration Mission (EM2). The effect that the flywheel load profile has on biomechanics is unknown when compared to free weights or a simulated free weight profile. The purpose of this evaluation is to compare the differences in lower body kinematics and kinetics between the flywheel and free weight profile. Test subjects were instrumented with reflective markers for motion capture data collection while exercising on the Device for Aerobic and Resistive Training (DART) prototype developed by TDA Research, Inc. of Wheat Ridge, CO. Exercises performed were either the squat while wearing a harness or deadlift while grasping a T-bar, both of which interfaced with the DART through a rope cable. The DART, a motorized device controlled via software, is capable of producing different load profiles. Profiles include simulated free weights with adjustable eccentric overload capability and flywheel. Test variables included the applied device load and the load profile, both set through the DART software interface. Motion capture data was collected with a 12 camera system (Smart-DX, BTS Bioengineering, Brooklyn, NY). Bilateral ground reaction force data were collected with force plates (P6000, BTS Bioengineering). DART cable force was recorded through an internal load cell. Data was collected from a total of four test subjects. The three repetition maximum was determined for each test subject for both squat and deadlift. High, medium and low loads were determined based on this maximum. The test subject performed five repetitions of each exercise at each load and each test trial was repeated twice. Cadence was controlled during exercising. Biomechanical data were used to drive the models utilizing the OpenSim software platform. Subject specific models were scaled to match the anthropometrics of the test subjects and used to estimate the peak joint angle, joint range of motion, the peak joint moment and the joint moment impulse of the lower extremity joints and the lumbar joint.These are preliminary results because the data analysis is ongoing. There was a lot of inter-subject variability, however, in general, there was a greater peak lumbar flexion angle for the flywheel squat exercise. There was a trend towards a greater range of motion at the hip for the squat exercise with free weight. There was also a greater hip extension, lumbar extension and ankle plantar flexion impulse moment during the squat exercise with free weight. During the deadlift exercise, the peak knee flexion angle and peak knee extension moment were greater when using the free weight profile. For deadlift, the hip extension, lumbar extension and ankle plantar flexion impulse moment tended to be greater with the free weight profile. Overall, the kinematic and kinetic outcomes for the flywheel profile were either statistically the same as free weight profile in many cases, significantly reduced in a few cases, and rarely higher.

Bioengineering↗

Comparing Theoretically Scaled Biomechanical Models

BACKGROUND An investigation into incorporating space suit aspects required a 50th-percentile male model which was not part of the existing dataset of models. Previously, theoretical models for 5th-percentile female and 95th-percentile male were created utilizing a scaled test subject as close as possible to the target height and weight. Scaling factors were created by taking the height ratio and applying it uniformly to the model body segments, then fine tuning to ensure the theoretical model’s height is as expected. This study was initiated to examine the existing method of isometrically scaling in OpenSim [1,2] and to create alternative methods which do not rely on an existing subject being close in height and weight to the theoretical model of interest. Generating a theoretical biomechanical model provides additional abilities without the reliance on available OpenSim models or real subjects. Gained abilities include creating different percentile models and attaining representative anthropometry for any target height/weight, such as targeting specific crew populations or gaps within the current dataset. METHODS AND RESULTS This study includes 3 methods for generating the theoretical model; utilizing the modified unscaled OpenSim Full Body Rajagopal Model (FBRM) [3,4], a dataset of scaled OpenSim models, and existing scaling factors from Dumas et al. [5]. All methods use the Anthropometric Survey of US Army Personnel (ANSUR II) [6] as an input of necessary anthropometric measurements. The following measurements are retrieved from the ANSUR II collection: mass, stature, cervicale height, acromial height, axilla height, waist height, trochanterion height, lateral femoral epicondyle height, lateral malleolus height, acromion-radiale length, radiale-stylion length, palm length, ball of foot length, bicristal breadth, bimalleolar breadth. Some of the measurements are direct segment lengths and others are utilized to derive segment lengths. Height, weight, and age ranges are the required inputs to parse the collection for a mean value of the measurements. A simple iterative process may be necessary for the output of mean mass and stature consistent with the theoretical model of interest. In some cases, one may specify exact values instead of a range but that is dependent upon whether those exact values pertain to a single subject from the ANSUR II collection. Equations from Dumas et al. were used to calculate scaling factors for the two methods that utilize OpenSim scaled and unscaled models. In the third method, Dumas’ scaling factors were used directly instead of generating our own. After scaling factors are achieved, they are applied along with the mass and segment lengths retrieved from ANSUR II in order to calculate the segment mass, Center of Mass (CoM), mass Moment of Inertia (MoI), and the joint location in the parent frame. The theoretical models from the different methods were compared to the previous existing method of isometrically scaling in OpenSim, as well as the standards found in NASA STD-3000 [7] and the NASA Human Integration Design Handbook [8]. The whole-body center of mass is the main comparison performed between the models and the standards. The body segment mass properties were also compared when possible. In some cases, the standards do not provide complete data, or the center of mass location is not provided with respect to the appropriate joint coordinate system. For a 50th-percentile male subject, results from isometric scaling in OpenSim and the method utilizing the unscaled FBRM were compared to the standards in NASA STD-3000. According to the standard, the whole-body vertical CoM location was taken from the head vertex to the CoM. The standards provide 80.2 cm for the CoM vertical component whereas isometric scaling in OpenSim and utilizing the unscaled FBRM provide 82.2 and 82.3 cm, respectively. Through definition, the whole-body CoM in the medial/lateral direction agreed across the models. Investigation is on-going to clearly identify the reference point pertaining to dorsal/ventral whole-body CoM position in standards and relate that to the theoretical models. REFERENCES [1] Delp, S.L., et al., “OpenSim: Open-source Software to Create and Analyze Dynamic Simulations of Movement”, IEEE Transactions on Biomedical Engineering, (2007). [2] Seth, A., Hicks J.L., Uchida, T.K., Habib, A., Dembia, C.L., Dunne, J.J., Ong, C.F., DeMers, M.S., Rajagopal, A., Millard, M., Hamner, S.R., Arnold, E.M., Yong, J.R., Lakshmikanth, S.K., Sherman,n M.A., Delp, S.L. OpenSim: Simulating musculoskeletal dynamics and neuromuscular control to study human and animal movement. Plos Computational Biology, 14(7). (2018) [3] R. K. Huffman, W. K. Thompson, C. A. Gallo, L. J. Quiocho, “Improvement of Scaling and Inverse Kinematic Results with Additional Upper Body Joints Added to Opensim Rajagopal Model”, NASA Human Research Program Investigator’s Workshop, (2019). [4] Huffman R.K., Thompson W., Gallo C., “Modified OpenSim Rajagopal Full Body Model”, New Technology Report, MSC-26872-1. (August 2020). [5] Dumas R., Cheze L. and Verriest J., 2007. “Adjustments to McConville et al. and Young et al. body segment inertial parameters”. Journal of Biomechanics 40, pp. 543-553 [6] Gordon C.C., 2012 “Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics”, US Army Natick Soldier RD&E Center. [7] NASA STD-3000/REV-B, 1995. “The Man-System Integration Standards” [8] NASA/SP-2010-3407/REV-1, 2014. “The Human Integration Design Handbook (HIDH)”

F N Matari↗

Novel 3D Force Sensors for a Cost-Effective 3D Force Plate for Biomechanical Analysis

Three-dimensional force plates are important tools for biomechanics discovery and sports performance practice. However, currently, available 3D force plates lack portability and are often cost-prohibitive. To address this, a recently discovered 3D force sensor technology was used in the fabrication of a prototype force plate. Thirteen participants performed bodyweight and weighted lunges and squats on the prototype force plate and a standard 3D force plate positioned in series to compare forces measured by both force plates and validate the technology. For the lunges, there was excellent agreement between the experimental force plate and the standard force plate in the X-, Y-, and Z-axes (r = 0.950–0.999, p < 0.001). For the squats, there was excellent agreement between the force plates in the Z-axis (r = 0.996, p < 0.001). Across axes and movements, root mean square error (RMSE) ranged from 1.17% to 5.36% between force plates. Although the current prototype force plate is limited in sampling rate, the low RMSEs and extremely high agreement in peak forces provide confidence the novel force sensors have utility in constructing cost-effective and versatile use-case 3D force plates.

42 ENGINEERING↗

Spaceflight effects on biomechanical and biochemical properties of rat vertebrae

The biomechanical and biochemical responses of lumbar vertebral bodies during a 12.5-day spaceflight (Cosmos 1887 biosatellite) were determined for rapidly growing rats (90-day-old, Czechoslovakian-Wistar). By use of age-matched vivarium controls (normal cage environment) and synchronous controls (simulated flight conditions), as well as a basal control group (killed before lift-off on the 1st day of flight), the combined influences of growth and space-flight could be examined. Centra of the sixth lumbar vertebrae (L6) were compressed to 50% strain at a fast strain rate while immersed in physiological buffer (37 degrees C). The body masses of vivarium and synchronous controls were significantly heavier than either the flight or basal controls. The flight group had an L6 vertebral body compressional stiffness that was 39% less than the vivarium controls, 47% less than the synchronous control, and 16% less than the basal controls. In addition, the average initial maximum load of the flight L6 was 22% less than vivarium controls and 18% less than the synchronous controls, whereas the linear compressional load of the flight group averaged 34% less than the vivarium and 25% less than the synchronous groups. The structural properties of the vertebrae from the 12.5-day-younger basal group closely resembled the flight vertebrae. Calcium, phosphorous, and hydroxyproline concentrations were not significantly different among the groups. Nevertheless, the lack of strength and stiffness development in spaceflight, coupled with a smaller proportion of mature hydroxypyridinoline cross-links, suggested that the 12.5 days of spaceflight slowed the maturation of trabecular bone in the vertebral bodies of rapidly growing rats.

Non-NASA Center↗

Effects of spaceflight on rat humerus geometry, biomechanics, and biochemistry

The effects of a 12.5-day spaceflight (Cosmos 1887 biosatellite) on the geometric, biomechanical, and biochemical characteristics of humeri of male specific pathogen-free rats were examined. Humeri of age-matched basal control, synchronous control, and vivarium control rats were contrasted with the flight bones to examine the influence of growth and space environment on bone development. Lack of humerus longitudinal growth occurred during the 12.5 days in spaceflight. In addition, the normal mid-diaphysial periosteal appositional growth was affected; compared with their controls, the spaceflight humeri had less cortical cross-sectional area, smaller periosteal circumferences, smaller anterior-posterior periosteal diameters, and smaller second moments of area with respect to the bending and nonbending axes. The flexural rigidity of the flight humeri was comparable to that of the younger basal control rats and significantly less than that of the synchronous and vivarium controls; the elastic moduli of all four groups, nonetheless, were not significantly different. Generally, the matrix biochemistry of the mid-diaphysial cross sections showed no differences among groups. Thus, the spaceflight differences in humeral mechanical strength and flexural rigidity were probably a result of the differences in humeral geometry rather than material properties.

NASA Discipline Number 26-10↗

Probabilistic Modeling of Intracranial Pressure Effects on Optic Nerve Biomechanics

Altered intracranial pressure (ICP) is involved/implicated in several ocular conditions: papilledema, glaucoma and Visual Impairment and Intracranial Pressure (VIIP) syndrome. The biomechanical effects of altered ICP on optic nerve head (ONH) tissues in these conditions are uncertain but likely important. We have quantified ICP-induced deformations of ONH tissues, using finite element (FE) and probabilistic modeling (Latin Hypercube Simulations (LHS)) to consider a range of tissue properties and relevant pressures.

biomechanics↗

Integrated Model of the Eye/Optic Nerve Head Biomechanical Environment

Visual Impairment and Intracranial Pressure (VIIP) syndrome is a concern for long-duration space flight. Previously, it has been suggested that ocular changes observed in VIIP syndrome are related to the cephalad fluid shift that results in altered fluid pressures [1]. We are investigating the impact of changes in intracranial pressure (ICP) using a combination of numerical models, which simulate the effects of various environment conditions, including finite element (FE) models of the posterior eye. The specific interest is to understand how altered pressures due to gravitational changes affect the biomechanical environment of tissues of the posterior eye and optic nerve sheath. METHODS: Additional description of the numerical modeling is provided in the IWS abstract by Nelson et al. In brief, to simulate the effects of a cephalad fluid shift on the cardiovascular and ocular systems, we utilized a lumped-parameter compartment model of these systems. The outputs of this lumped-parameter model then inform boundary conditions (pressures) for a finite element model of the optic nerve head (Figure 1). As an example, we show here a simulation of postural change from supine to 15 degree head-down tilt (HDT), with primary outcomes being the predicted change in strains at the optic nerve head (ONH) region, specifically in the lamina cribrosa (LC), retrolaminar optic nerve, and prelaminar neural tissue (PLNT). The strain field can be decomposed into three orthogonal components, denoted as the first, second and third principal strains. We compare the peak tensile (first principal) and compressive (third principal) strains, since elevated strain alters cell phenotype and induces tissue remodeling. RESULTS AND CONCLUSIONS: Our lumped-parameter model predicted an IOP increase of c. 7 mmHg after 21 minutes of 15 degree HDT, which agreed with previous reports of IOP in HDT [1]. The corresponding FEM simulations predicted a relative increase in the magnitudes of the peak tensile and compressive strains in the lamina cribrosa of 42 and 43, respectively (Fig. 2). The corresponding changes in the optic nerve strains were 17 and 39, while in the PLNT they were 47 and 43. These magnitudes of relative elevations in peak strains may induce a phenotypic response in resident mechano-responsive resident cells [2]. This approach may be expanded to investigate other environmental changes (e.g. parabolic flight). Through our VIIP SCHOLAR project, we will validate and improve these integrated models by measuring patient-specific changes in optic nerve sheath geometry in patients with idiopathic intracranial hypertension before and after lumbar puncture and CSF removal.

biomechanics↗

Enhanced biomechanical performance of additively manufactured Ti-6Al-4V bone plates

As the global trauma fixation devices market expands rapidly, it is imperative to improve the production of fixation devices through enhanced design accuracy and fit for best performance and maximum patient comfort. Selective laser melting (SLM) is one of the mature additive manufacturing methods, which provides a viable route for the rapid production of such devices. In this work, the ability of SLM to produce near-net-shape parts, as desired for medical implants, was utilized for the fabrication of bone plates from Ti-6Al-4V alloy powder. Martensitic microstructure obtained after the printing of alloy resulted in poor ductility, limiting its application in the field of orthopedics. A specially designed repeated cyclic heating and cooling close to but below the β-transus was used to transform from acicular to a bimodal microstructure without the need for plastic deformation prior to heat treatment for improving the ductility. Bone plates subjected to this heat treatment were mechanically tested by means of tensile and 3-point bend tests and demonstrated large improvement in ductility, and the values were comparable to those similar plates prepared from wrought alloy. Other important properties required for implants were assessed, such as corrosion resistance in simulated body fluid and cytocompatibility in vitro using MC3T3-E1 cells. These results for the bone plate after heat treatment were excellent and similar to those of the additively manufactured and wrought plates. Taken together, the performance of the additively manufactured bone plates after subjecting to heat treatment was similar to those of bone plate manufactured using wrought alloy. These results have important implications for the fabrication of patient-specific metallic orthopedic devices using SLM without compromising their biomechanical performance by subjecting them to a tailored heat treatment.

36 MATERIALS SCIENCE↗

An implantable biomechanical energy harvester for animal monitoring devices

Insufficient service life and the resulting need for battery replacements have been a great challenge for implantable electronic devices. This is particularly true for animal tracking applications, because recapturing animals is often unlikely once they are released to the wild. To tackle this problem, we developed a biomechanical energy harvester that uses a Macro Fiber Composite™ (MFC) piezoelectric beam to harvest the mechanical energy from animals’ body bending movements as the power source for implantable and wearable devices. Prototypes of an underwater acoustic transmitter using this technology were subdermally implanted into juvenile white sturgeon and their energy harvesting performance was evaluated through the device’s transmissions. Additionally, the fish successfully recovered from the implantation surgery and freely swam inside a tank. The transmitter prototypes in the fish continually transmitted signals for a period up to 5 weeks. A benchtop test setup was also created to emulate the fish’s body bending, estimate the device’s energy harvesting performance in the live fish, and perform accelerated fatigue testing of the energy harvester by applying test parameters learned from a video study of the fish’s body movement and behavior characteristics. The gradual depolarization of the piezoelectric ceramic material in the MFC under cyclic mechanical loading was the main limiting factor for the life span of the energy harvester. Pathways for improvement are proposed to achieve long-term efficacy of powering implantable and wearable electronic devices.

42 ENGINEERING↗

Harnessing quantum light for microscopic biomechanical imaging of cells and tissues

The biomechanical properties of cells and tissues play an important role in our fundamental understanding of the structures and functions of biological systems at both the cellular and subcellular levels. Recently, Brillouin microscopy, which offers a label-free spectroscopic means of assessing viscoelastic properties in vivo, has emerged as a powerful way to interrogate those properties on a microscopic level in living tissues. However, susceptibility to photodamage and photobleaching, particularly when high-intensity laser beams are used to induce Brillouin scattering, poses a significant challenge. This article introduces a transformative approach designed to mitigate photodamage in biological and biomedical studies, enabling nondestructive, label-free assessments of mechanical properties in live biological samples. By leveraging quantum-light-enhanced stimulated Brillouin scattering (SBS) imaging contrast, the signal-to-noise ratio is significantly elevated, thereby increasing sample viability and extending interrogation times without compromising the integrity of living samples. The tangible impact of this methodology is evidenced by a notable three-fold increase in sample viability observed after subjecting the samples to three hours of continuous squeezed-light illumination, surpassing the traditional coherent light-based approaches. The quantum-enhanced SBS imaging holds promise across diverse fields, such as cancer biology and neuroscience where preserving sample vitality is of paramount significance. By mitigating concerns regarding photodamage and photobleaching associated with high-intensity lasers, this technological breakthrough expands our horizons for exploring the mechanical properties of live biological systems, paving the way for an era of research and clinical applications.

Li, Tian↗

Wearable Technology and Its Influence on Motor Development and Biomechanical Analysis

The convergence among biomechanics, motor development, and wearable technology redefines our understanding of human movement. These technologies allow for the continuous monitoring of motor development and the state of motor abilities from infancy to old age, enabling early and personalized interventions to promote healthy motor skills. For athletes, they offer valuable insights to optimize technique and prevent injuries, while in old age, they help maintain mobility and prevent falls. Integration with artificial intelligence further extends these capabilities, enabling sophisticated data analysis. Wearable technology is transforming the way we approach motor development and maintenance of motor skills, offering unprecedented possibilities for improving health, performance, and quality of life at every stage of life. The promising future of these technologies paves the way for an era of more personalized and effective healthcare, driven by innovation and interdisciplinary collaboration.

Morouço, Pedro (ORCID:0000000259569790)↗