Search NASA⌕ Search

SEARCH · Search NASA

Results for “blower door testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

LIQUIDARMOR CM Flashing and Sealant, High Impact Technology Demonstration

Air leakage is responsible for about 1.1 quads of energy or 6% of the total energy used by commercial buildings in the US. Consequently, infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning loads in commercial buildings. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. LIQUIDARMORTM CM Flashing and Sealant is an example of these new advanced material technologies. This technology is a spray-applied sealant and liquid flashing and can span gaps that are up to ¼ in. wide without a supporting material. ORNL verified the performance of LIQUIDARMORTM CM with field tests and energy simulations from a building in which LIQUIDARMORTM CM was one of components of the air barrier system. The Homeland Security Training Center (HTC) at the College of DuPage in Glen Ellyn, IL, served as the demonstration site. Blower door test results show the average air leakage rate in the demonstration site to be 0.15 cfm/ft2 at 1.57 psf, or 63% lower than the 0.4 cfm at 1.57 psf specified in the 2015 International Energy Conservation Code (IECC). According to simulation results, HTC lowered its annual heating and cooling cost by about $3,000 or 9% compared to a similar building that lacked an air barrier system. This demonstration project serves as an example of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrates the energy and financial savings that such an airtight envelope could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 story bungalow↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 STORY BUNGALOW↗

Building America Case Study: Project Overcoat: Airtightness Strategies and Impacts for 1-1/2 Story Homes, Minneapolis, Minnesota (Fact Sheet)

In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 STORY BUNGALOW↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weatherizing Wilkes-Barre

Ride along with some weatherizers in Wilkes-Barre, PA, as they blower door test, manage z-doors, and dense pack their way to an energy efficient future one house at a time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy 101: Home Energy Assessment

A home energy checkup helps owners determine where their house is losing energy and money - and how such problems can be corrected to make the home more energy efficient. A professional technician - often called an energy auditor - can give your home a checkup. You can also do some of the steps yourself. Items shown here include checking for leaks, examining insulation, inspecting the furnace and ductwork, performing a blower door test and using an infrared camera.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building Energy Codes: Air Leakage Guide

Meeting the Air Leakage Requirements of the 2012 IECC provides a resource for understanding the requirements in the 2012 IECC to limit air leakage through a building's thermal envelope, and guidance on how to meet these requirements. It also provides information from Building America's Air Sealing Guide, best practices, and case studies on homes that currently are meeting the requirements. Finally, it provides information critical to understanding how to conduct a required blower door test to assess the actual air leakage rate of the home, report the results, and validate energy code compliance. To enhance the connection of the information to the relevant codes, the 2012 IECC and relevant 2012 International Residential Code requirements are referenced throughout the guide.

Energy efficiency, home comfort, building envelope↗

Predicting Envelope Leakage in Attached Dwellings (Fact Sheet)

The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number is used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Predicting Envelope Leakage in Attached Dwellings

The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this “solo” test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. In an attempt to create a simplified tool for predicting leakage to the outside, Building America team Consortium for Advanced Residential Buildings (CARB) performed a preliminary statistical analysis on blower door test results from 112 attached dwelling units in four apartment complexes. Although the subject data set is limited in size and variety, the preliminary analyses suggest significant predictors are present and support the development of a predictive model. Further data collection is underway to create a more robust prediction tool for use across different construction types, climate zones, and unit configurations.

algorithm↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Envelope Leakage Model

The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Field Testing of Compartmentalization Methods for Multifamily Construction (Fact Sheet)

The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, thus driving the need for easier and more effective methods of compartmentalization in multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Field Testing of Compartmentalization Methods for Multifamily Construction

Fire-resistance rated (or area separation) wall assemblies present a great difficulty in air sealing/compartmentalization, particularly in townhouse construction. To address this challenge, Building Science Corporation partnered with builder K. Hovnanian Homes to determine whether taping exterior sheathing details improves air sealing in townhouse and multifamily construction, and to better understand air leakage pathways.

air leakage↗

Field Testing of Compartmentalization Methods for Multifamily Construction - Washington DC

BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction - Capitol Heights, MD 20743 A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) with a rear-facing "tuck under" garage. The three-story townhome design results in 3 ACH50 being equivalent to a stringent surface-area based target (0.16-0.17 CFM50/ft2 building enclosure). The party walls between units were area separation walls, with a 2-hour fire resistance rating (Underwriters Laboratories U347 assembly; equivalent to U373 and U336). This assembly has a 1-in. vertical air cavity on each side of a 2-in. vertical gypsum panel in the middle of the assembly, resulting in an airflow network that is connected over multiple floors (despite nominal draft stopping), and has potential connections to exterior conditions. The test townhomes were built with several experimental airtightness details, including taping of exterior sheathing as an air barrier closure detail (in particular, at area separation walls). Various measures were applied to the units for this experiment, including a "control" conventional construction unit and some units with "improved" detailing (without taped sheathing).

air leakage↗