Search NASA⌕ Search

SEARCH · Search NASA

Results for “boolean factorization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

21 records · Page 2

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

Data Analysis

Analysis of the material protection, control, and accountability (MPC&A) system is necessary to understand the limits and vulnerabilities of the system to internal threats. A self-appraisal helps the facility be prepared to respond to internal threats and reduce the risk of theft or diversion of nuclear material. The material control and accountability (MC&A) system effectiveness tool (MSET) fault tree was developed to depict the failure of the MPC&A system as a result of poor practices and random failures in the MC&A system. It can also be employed as a basis for assessing deliberate threats against a facility. MSET uses fault tree analysis, which is a top-down approach to examining system failure. The analysis starts with identifying a potential undesirable event called a 'top event' and then determining the ways it can occur (e.g., 'Fail To Maintain Nuclear Materials Under The Purview Of The MC&A System'). The analysis proceeds by determining how the top event can be caused by individual or combined lower level faults or failures. These faults, which are the causes of the top event, are 'connected' through logic gates. The MSET model uses AND-gates and OR-gates and propagates the effect of event failure using Boolean algebra. To enable the fault tree analysis calculations, the basic events in the fault tree are populated with probability risk values derived by conversion of questionnaire data to numeric values. The basic events are treated as independent variables. This assumption affects the Boolean algebraic calculations used to calculate results. All the necessary calculations are built into the fault tree codes, but it is often useful to estimate the probabilities manually as a check on code functioning. The probability of failure of a given basic event is the probability that the basic event primary question fails to meet the performance metric for that question. The failure probability is related to how well the facility performs the task identified in that basic event over time (not just one performance or exercise). Fault tree calculations provide a failure probability for the top event in the fault tree. The basic fault tree calculations establish a baseline relative risk value for the system. This probability depicts relative risk, not absolute risk. Subsequent calculations are made to evaluate the change in relative risk that would occur if system performance is improved or degraded. During the development effort of MSET, the fault tree analysis program used was SAPHIRE. SAPHIRE is an acronym for 'Systems Analysis Programs for Hands-on Integrated Reliability Evaluations.' Version 1 of the SAPHIRE code was sponsored by the Nuclear Regulatory Commission in 1987 as an innovative way to draw, edit, and analyze graphical fault trees primarily for safe operation of nuclear power reactors. When the fault tree calculations are performed, the fault tree analysis program will produce several reports that can be used to analyze the MPC&A system. SAPHIRE produces reports showing risk importance factors for all basic events in the operational MC&A system. The risk importance information is used to examine the potential impacts when performance of certain basic events increases or decreases. The initial results produced by the SAPHIRE program are considered relative risk values. None of the results can be interpreted as absolute risk values since the basic event probability values represent estimates of risk associated with the performance of MPC&A tasks throughout the material balance area (MBA). The RRR for a basic event represents the decrease in total system risk that would result from improvement of that one event to a perfect performance level. Improvement of the basic event with the greatest RRR value produces a greater decrease in total system risk than improvement of any other basic event. Basic events with the greatest potential for system risk reduction are assigned performance improvement values, and new fault tree calculations show the improvement in total system risk. The operational impact or cost-effectiveness from implementing the performance improvements can then be evaluated. The improvements being evaluated can be system performance improvements, or they can be potential, or actual, upgrades to the system. The RIR for a basic event represents the increase in total system risk that would result from failure of that one event. Failure of the basic event with the greatest RIR value produces a greater increase in total system risk than failure of any other basic event. Basic events with the greatest potential for system risk increase are assigned failure performance values, and new fault tree calculations show the increase in total system risk. This evaluation shows the importance of preventing performance degradation of the basic events. SAPHIRE identifies combinations of basic events where concurrent failure of the events results in failure of the top event.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CANA v1.0.0: efficient quantification of canalization in automata networks

The biomolecular networks underpinning cell function exhibit canalization, or the buffering of fluctuations required to function in a noisy environment. We present a new major release of $\tt{CANA}$, v1.0.0, an open-source Python package for understanding canalization in automata network models, discrete dynamical systems in which activation of biomolecular entities (e.g. transcription of genes) is modeled as the activity of coupled automata. One understudied putative mechanism for canalization is the functional equivalence of biomolecular regulators (e.g. among the transcription factors for a gene). We study this mechanism using the theory of symmetry in discrete functions. We present a new exact method, $\tt{schematodes}$, for finding maximal symmetry groups among the inputs to discrete functions, and integrate it into $\tt{CANA}$. The $\tt{schematodes}$ method substantially outperforms the inexact method of previous $\tt{CANA}$ versions both in speed and accuracy. We apply $\tt{CANA}$ v1.0.0 to study symmetry in 74 experimentally supported automata network models from the Cell Collective (CC) repository. The symmetry distribution is significantly different in the CC than in random automata with the same in-degree (connectivity) and bias (average output) (Kolmogorov–Smirnov test, P ≪ .001). Its spread is much wider than in a null model (IQR 0.31 versus IQR 0.20 with equal medians), demonstrating that the CC is enriched in functions with extreme symmetry or asymmetry.

Boolean networks↗