Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tackling the Giants: Applying Smart Labs Principles to Constant Air Volume Lab Buildings

Laboratories typically consume 3 to 10 times more energy than similarly sized commercial buildings, and as much as 50% of that energy is wasted by inefficient and poorly operating fume hoods and ventilation systems. One challenge faced by older laboratory buildings is the heating, ventilation, and air-conditioning systems serving many of these buildings. The older systems are usually constant air volume (CAV) systems that maintain constant ventilation rates that cause excess airflow and inefficient energy use. Variable air volume systems can be more efficient systems with sensors to detect the need for a change in volumetric flow rate; however; renovation of ventilation systems can create disruption to ongoing research and operations along with considerable up-front costs. When a Smart Labs program is implemented, an organization has a systems-based management approach that yields a high-performing laboratory building. As decarbonization continues as a priority for sites, buildings with CAV systems are difficult to address. This work centers around practical guidance for improving lab buildings with CAV. In conjunction with industry input on top technology solutions and best practices, recommendations will include performing a laboratory ventilation risk assessment in conjunction with robust retro-commissioning work, which is a crucial step in the Smart Lab process. By applying Smart Labs principles, the aging laboratory building stock of 153,343 (Lawrence Berkeley National Laboratory [LBNL] 2017), comprising roughly 500,000 lab spaces in the United States, can be brought to safe and high-performance operations.

building↗

Effect of Environmental and Socioeconomic Factors on Increased Early Childhood Blood Lead Levels: A Case Study in Chicago

This study analyzes the prevalence of elevated blood lead levels (BLLs) in children across Chicagoland zip codes from 2019 to 2021, linking them to socioeconomic, environmental, and racial factors. Wilcoxon tests and generalized additive model (GAM) regressions identified economic hardship, reflected in per capita income and unemployment rates, as a significant contributor to increased lead poisoning (LP) rates. Additionally, LP rates correlate with the average age of buildings, particularly post the 1978 lead paint ban, illustrating policy impacts on health outcomes. The study further explores the novel area of land surface temperature (LST) effects on LP, finding that higher nighttime LST, indicative of urban heat island effects, correlates with increased LP. This finding gains additional significance in the context of anthropogenic climate change. When these factors are combined with the ongoing expansion of urban territories, a significant risk exists of escalating LP rates on a global scale. Racial disparity analysis revealed that Black and Hispanic/Latino populations face higher LP rates, primarily due to unemployment and older housing. The study underscores the necessity for targeted public health strategies to address these disparities, emphasizing the need for interventions that cater to the unique challenges of these at-risk communities.

Lee, Jangho (ORCID:0000000289421092)↗

An Intermediate-age Alpha-rich Galactic Population in K2

We explore the relationships between the chemistry, ages, and locations of stars in the Galaxy using asteroseismic data from the K2 mission and spectroscopic data from the Apache Point Galactic Evolution Experiment survey. Previous studies have used giant stars in the Kepler field to map the relationship between the chemical composition and the ages of stars at the solar circle. Consistent with prior work, we find that stars with high [α/Fe] have distinct, older ages in comparison to stars with low [α/Fe]. We provide age estimates for red giant branch (RGB) stars in the Kepler field, which support and build upon previous age estimates by taking into account the effect of α-enrichment on opacity. Including this effect for [α/Fe]-rich stars results in up to 10% older ages for low-mass stars relative to corrected solar mixture calculations. This is a significant effect that Galactic archeology studies should take into account. Looking beyond the Kepler field, we estimate ages for 735 RGB stars from the K2 mission, mapping age trends as a function of the line of sight. We find that the age distributions for low- and high-[α/Fe] stars converge with increasing distance from the Galactic plane, in agreement with suggestions from earlier work. We find that K2 stars with high [α/Fe] appear to be younger than their counterparts in the Kepler field, overlapping more significantly with a similarly aged low-[α/Fe] population. This observation may suggest that star formation or radial migration proceeds unevenly in the Galaxy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Issues in the reconstruction of environmental doses on the basis of thermoluminescence measurements in the Techa riverside

The potential of thermoluminescence measurements of bricks from the contaminated area of the Techa river valley, Southern Urals, Russia, for reconstructing external exposures of affected population groups has been studied. Thermoluminescence dating of background samples was used to evaluate the age of old buildings available on the river banks. The anthropogenic gamma dose accrued in exposed samples is determined by subtracting the natural radiation background dose for the corresponding age from the accumulated dose measured by thermoluminescence. For a site in the upper Techa river region, where the levels of external exposures were extremely high, the depth-dose distribution in bricks and the dependence of accidental dose on the height of the sampling position were determined. For the same site, Monte Carlo simulations of radiation transport were performed for different source configurations corresponding to the situation before and after the construction of a reservoir on the river and evacuation of the population in 1956. A comparison of the results provides an understanding of the features of the measured depth-dose distributions and height dependencies in terms of the source configurations and shows that bricks from the higher sampling positions are likely to have accrued a larger fraction of anthropogenic dose from the time before the construction of the reservoir. The applicability of the thermoluminescent dosimetry method to environmental dose reconstruction in the middle Techa region, where the external exposure was relatively low, was also investigated.

NASA Discipline Radiation Health↗

Viscoplastic Model Development to Account for Strength Differential: Application to Aged Inconel 718 at Elevated Temperature

The magnitude of yield and flow stresses in aged Inconel 718 are observed to be different in tension and compression. This phenomenon, called the Strength differential (SD), contradicts the metal plasticity axiom that the second deviatoric stress invariant alone is sufficient for representing yield and flow. Apparently, at least one of the other two stress invariants is also significant. A unified viscoplastic model was developed that is able to account for the SD effect in aged Inconel 718. Building this model involved both theory and experiments. First, a general threshold function was proposed that depends on all three stress invariants and then the flow and evolution laws were developed using a potential-based thermodynamic framework. Judiciously chosen shear and axial tests were conducted to characterize the material. Shear tests involved monotonic loading, relaxation, and creep tests with different loading rates and load levels. The axial tests were tension and compression tests that resulted in sufficiently large inelastic strains. All tests were performed at 650 C. The viscoplastic material parameters were determined by optimizing the fit to the shear tests, during which the first and the third stress invariants remained zero. The threshold surface parameters were then fit to the tension and compression test data. An experimental procedure was established to quantify the effect of each stress invariant on inelastic deformation. This requires conducting tests with nonproportional three-dimensional load paths. Validation of the model was done using biaxial tests on tubular specimens of aged Inconel 718 using proportional and nonproportional axial-torsion loading. These biaxial tests also helped to determine the most appropriate form of the threshold function; that is, how to combine the stress invariants. Of the set of trial threshold functions, the ones that incorporated the third stress invariant give the best predictions. However, inclusion of the first stress invariant does not significantly improve the model predictions. The model shows excellent predictive capability for nonproportional load paths. Additionally, it reduces to the well-known models of Mises Drucker and Drucker-Prager. The requisite experiments involve reasonably simple load paths in the axial-shear stress plane and hence can be performed on a variety of different materials: be they metallic, geological. polymeric, ceramic or granular. The general form of the threshold function allows representation of inelastic deformation in a range of materials.

Iyer, Saiganesh↗

Cryogenic Moisture Analysis of Spray-On Foam Insulation (SOFI)

The NASA Cryogenics Test Laboratory at Kennedy Space Center conducted long-term testing of SOFI materials under actual-use cryogenic conditions. The lab tested NCFI 24-124 (acreage foam), BX-265 (close-out foam, including intertank flange and bipod areas), and a potential alternate material, NCFI 27-68 (acreage foam with the flame retardant removed). Specimens of all three materials were placed at a site that simulated aging (the Vehicle Assembly Building [VAB]) and a site that simulated weathering (Atmospheric Exposure Test Site [beach site]). After aging/ weathering intervals of 3, 6, and 12 months, the samples were retrieved and tested for their ability to absorb moisture under conditions similar to those experienced by the Space Shuttle External Tank (ET) during the loading of cryogenic propellants.

Source record↗

Minimized aging of isocyanurate-based rigid cellular foams for buildings through tailored barrier facers and optimized formulation

The thermal resistivity (h·ft 2 ·°F/Btu/in.) of closed-cell rigid foam insulation materials significantly decreases over time. Diffusion-tight facers are designed to significantly enhance initial thermal resistivity and long-term thermal performance by preventing gas diffusion into the foam cells and inhibiting the escape of low thermal conductivity blowing agents. In addition to the gas diffusion property of the facer film, adhesion between the foam and the facer is crucial for achieving diffusion-tight bonding. Here, this study addresses the challenge of thermal aging by investigating how facer film properties and foam formulation influence the durability of thermal performance. A systematic evaluation was conducted to understand the effects of polymeric barrier films, surface treatments, facer coverage, and foam matrix rigidity on thermal resistivity over time. Key findings reveal that diffusion-tight facers, particularly those with metallized layers and compatible heat seal layers, significantly reduce gas exchange and improve foam-facer adhesion. The optimized system, incorporating barrier facers and a tailored polyisocyanurate foam formulation, achieved initial and aged thermal resistivity values after 200 days of approximately 8.3 and 7.4 h ft 2 ·°F/Btu/in., respectively representing only a 10 % reduction compared to a 17 % reduction observed in control samples without facers. Notably, polyurethane spray foams with facers exhibited only a 4 % reduction in thermal resistivity, compared to a 23 % decrease in control samples, demonstrating nearly six times better retention of thermal performance. This innovative facer technology presents a promising solution for reducing energy costs and represents a significant advancement in optimizing energy management for building envelopes in future technologies. This technology can also be adapted for other applications that necessitate the preservation of long-term thermal performance.

Wanasinghe, Shiwanka Vidarshi [Oak Ridge National ↗

Oak Ridge National Laboratory Roane and Anderson Counties, Tennessee Historic Architectural Resource Survey June 2018

From February through September 2017, Cultural Resource Analysts, Inc. personnel completed a historic architectural resource survey of the Oak Ridge National Laboratory in Roane and Anderson Counties, Tennessee. The survey was completed at the request of UT-Battelle, LLC, the private not-for-profit company that manages and operates Oak Ridge National Laboratory for the U.S. Department of Energy. The purpose of the survey was to assist the Department of Energy in complying with the National Historic Preservation Act of 1966, as amended, by providing updated recommendations regarding the National Register of Historic Places eligibility of historic architectural resources at Oak Ridge National Laboratory. The survey included the entirety of Oak Ridge National Laboratory’s main campus that occupies approximately 1,100 acres in Bethel and Melton Valleys and on Chestnut Ridge. Based on Facilities Information Management System data and guidance provided by UT-Battelle, LLC, preservation and modernization staff, the survey team developed a list of resources for inclusion in the survey. The list included all substantial buildings constructed in or before 1980 in order to provide sufficient coverage of buildings that will turn 50 years of age within the next decade. Only those buildings with recorded area over 100 sq ft were included in the survey. Additionally, the UT-Battelle team identified 15 buildings for more intensive survey because such buildings are central to Oak Ridge National Laboratory’s future mission needs and are expected to undergo renovations in the foreseeable future. These building were subject to both exterior and interior documentation with particular focus on identifying character-defining features, and thus were subject to more detailed analysis than the other resources included in the survey. The findings of this historic resource survey build on the conclusions of the 1994 survey by DuVall & Associates, Inc., as well as the survey updates completed by Thomason and Associates in 2004 and 2015 in support of the Oak Ridge National Laboratory Historic Preservation Plan. Within 12 distinct areas of Oak Ridge National Laboratory, as well as outlying areas, the survey recorded 195 buildings and structures constructed in or before 1980. In consideration of the role and significance of each area and each individual resource within the context of Oak Ridge National Laboratory, and in light of their current integrity and condition, each recorded resource was evaluated to determine if it is eligible for listing in the National Register of Historic Places.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Breast-Specific Molecular Clocks Comprised of ELF5 Expression and Promoter Methylation Identify Individuals Susceptible to Cancer Initiation

A robust breast cancer prevention strategy requires risk assessment biomarkers for early detection. We show that expression of ELF5, a transcription factor critical for normal mammary development, is downregulated in mammary luminal epithelia with age. DNA methylation of the ELF5 promoter is negatively correlated with expression in an age-dependent manner. Both ELF5 methylation and gene expression were used to build biological clocks to estimate chronological ages of mammary epithelia. ELF5 clock-based estimates of biological age in luminal epithelia from average-risk women were within three years of chronological age. Biological ages of breast epithelia from BRCA1 or BRCA2 mutation carriers, who were high risk for developing breast cancer, suggested they were accelerated by two decades relative to chronological age. The ELF5 DNA methylation clock had better performance at predicting biological age in luminal epithelial cells as compared with two other epigenetic clocks based on whole tissues. We propose that the changes in ELF5 expression or ELF5-proximal DNA methylation in luminal epithelia are emergent properties of at-risk breast tissue and constitute breast-specific biological clocks.

60 APPLIED LIFE SCIENCES↗

TASTI-GRID: a holistic view of Florida's grid resilience opportunities

In December of 2025, the American Society of Civil Engineers updated Florida’s infrastructure grade to a ”C+” – reflecting overall investments in recent years. With the recommendation to further strengthen the electric grid and establish consistent building standards, extreme weather, aging infrastructure, and population in-migration are still compounding Florida’s grid vulnerabilities. Key challenges related to hurricane and other tropical & marine weather events are not unique to Florida. However, the state’s topography, location, demographics, and variation among rural and urban centers for tourism and industry, demonstrate the need for unique approaches to advancing critical infrastructure resilience, particularly for large concentrations of elderly residents or in areas of historic underinvestment. Florida’s grid asset advancements are credited with a reduction in average power outage durations. Yet, improvements since 2021 have set the stage for future resilience activities – as modernization efforts have greatly improved data collection – enabling better understanding of vulnerabilities and trends across counties and localities (particularly in Central Florida).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methodology for designing accelerated aging tests for predicting life of photovoltaic arrays

A methodology for designing aging tests in which life prediction was paramount was developed. The methodology builds upon experience with regard to aging behavior in those material classes which are expected to be utilized as encapsulant elements, viz., glasses and polymers, and upon experience with the design of aging tests. The experiences were reviewed, and results are discussed in detail.

Gaines, G. B.↗

Thermal Performance of Aged and Weathered Spray-On Foam Insulation (SOFI) Materials Under Cryogenic Vacuum Conditions (Cryostat-4)

The NASA Cryogenics Test Laboratory at Kennedy Space Center conducted long-term testing of SOFI materials under actual-use cryogenic conditions with Cryostat-4. The materials included in the testing were NCFI 24-124 (acreage foam), BX-265 (close-out foam, including intertank flange and bipod areas), and a potential alternate material, NCFI 27-68, (acreage foam with the flame retardant removed). Specimens of these materials were placed at two locations: a site that simulated aging (the Vehicle Assembly Building [VAB]) and a site that simulated weathering (the Atmospheric Exposure Test Site [beach site]). After aging/weathering intervals of 3, 6, and 12 months, the samples were retrieved and tested for their thermal performance under cryogenic vacuum conditions with test apparatus Cryostat-4.

Source record↗

Leveraging Partnerships, Science Content, Special Events, and NASA Assets to Help Girl Scouts Earn Space Science Badges

Throughout 2019, NASA celebrated historic anniversaries and announced bold new programs generating excitement about earth and space exploration. One of the most notable events was the celebration of the 50th anniversary of Apollo 11 historic first steps on the Moon. Complementing this anniversary event were the additional activities and events conducted across the agency that highlighted the many science achievements that were attained across all of NASA’s Science Mission Directorate (SMD) Divisions (earth, planetary, heliophysics, and astrophysics). Further excitement was generated through NASA’s Artemis program which plans to send the first woman and next man to the surface of the Moon. NASA continues to inspire the public including learners of all ages around the world. Building on this momentum, in October 2019, the Astromaterials Research and Exploration Science (ARES) Science Engagement team partnered with the Lunar and Planetary Institute (LPI) and the Girl Scouts of San Jacinto to host an event that enabled Girl Scouts to earn recently released space science badges developed by the Reach for the Stars: NASA Science for Girls Scouts Program. The event celebrated SMD science and highlighted Earth’s Moon and International Observe the Moon Night (InOMN) while facilitating the earning of the NASA inspired space science badges. This event was coordinated and led by the ARES Science Engagement team as part of their collaborative work and involvement in NASA’s SMD Science Activation Program.

Graff, P. V.↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗