Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE

Component pose reconstruction using a single robotic total station for panelized building envelopes

The construction industry can benefit greatly from increased automation in construction processes in terms of precision, time, and labor costs. This is especially true for prefabricated construction for either new buildings or envelope retrofits. Here, prefabricated components are manufactured offsite according to design specifications and installed onsite. Accurate information on the component’s position and orientation (pose) is needed to achieve this. A tool named “Real-Time Evaluator” (RTE), designed to autonomously track prefabricated components as they are being installed and provide real-time installation instructions, is currently under development using a single robotic total station. This is challenging since at least three points are needed to determine the pose of an object in space. To achieve this goal with a single robotic total station, two key algorithms were developed: the “resection” algorithm aligns the digital twin with the physical twin regardless of the location of the total station, and the “transformation” algorithm gives instructions of translations and rotations to installers to achieve the desired installation pose. The algorithms were evaluated experimentally on a lab-scale demonstration. Results show that the resection algorithm achieved an average error of < 3.1 mm, while the transformation algorithm predicted the rotation angle along a single axis with an error of < 0.5◦.

Tang, Mengjia

Thermal diode and thermal switch for bi-directional heat transfer in building envelopes

The present disclosure relates to a directional heat transfer using thermal control devices, including a dual phase change thermal diode and an active contact-based thermal switch. The thermal diode includes a positive temperature coefficient switching material and a negative temperature coefficient switching material arranged in series. The thermal switch includes two thermally conducting surfaces which may be moved to contact (i.e., having a distance between them of substantially zero) creating minimal thermal contact resistance. Both thermal control devices may be used to control heat flow into and/or out of a building.

Kishore, Ravi Anant

Hygrothermal Performance of Bio-Based Materials in Residential Building Wall Envelope Systems

In the United States, building envelope systems contribute approximately 28% of building energy consumption, with walls being a primary factor. As the construction industry explores new approaches to lower the energy intensity needed to manufacture materials and, in turn, reduce energy consumption, bio-based materials are gaining attention as a promising alternative. While prior studies have demonstrated that bio-based materials can decrease material energy intensity, their long-term hygrothermal behavior within a whole residential wall system is not yet fully understood. This study aims to evaluate the potential of replacing Oriented Strand Board (OSB) and drywall in residential wall systems with bio-based alternatives. The research focuses on two bio-based materials, assessing their hygrothermal performance under Chicago climate condition (Climate Zone 5). To achieve that, a series of laboratory experiments were conducted to measure key properties of the bio-based materials such as thickness, dimensions, density, thermal conductivity (as a function of temperature and humidity), moisture-dependent permeance and water vapor permeability (WVP), and sorption isotherms. These properties were then used in WUFI® simulations to predict the moisture durability of a standard residential wall system in Climate Zone 5. Results show that substituting OSB and drywall with bio-based materials can achieve acceptable moisture durability, effectively mitigating risks of mold growth and structural damage over time.

Palani, Hevar [ORNL] (ORCID:0000000220211994)

A review of prefabricated overclad panels for building energy retrofits

Over 50% of existing buildings in the US were constructed before 1980 and lack modern, energy-efficient technologies. Despite the large number of old buildings, less than 2% of buildings are retrofitted each year with many of those retrofits consisting of small incremental improvements that often ignore the building envelope. The opaque building envelope affects 25% of building energy use equating to 10% of total US primary energy use. To meet decarbonization goals by 2035, the US must increase the rate of retrofit of existing building envelopes. The process of prefabrication is one potential opportunity to increase the rate of envelope retrofits and reduce costs. Prefabrication is the process of manufacturing construction components in a controlled environment before shipping them on-site to perform assembly of the construction. The process of prefabrication has been demonstrated to increase production efficiency, quality control, and rate of production. Prefabricated overclad panels, consisting of a cladding material and insulation designed to be installed over the existing envelope, have been successfully used to retrofit existing buildings in countries other than the US; however, the technology still has some barriers to major market adoption within the US. This paper will present a review of current implementations and demonstrations of prefabricated overclad panels. The review will include identification of panel types, materials, and applications and aims to identify barriers to retrofit market entry and widespread adoption.

Hayes, Nolan [ORNL] (ORCID:0000000332245718)

Cost-Effective Thermally Activated Building Systems to Support a Power Grid System With High Penetrations Of As-Available Renewable Energy Resources

With a goal to reduce the energy cost for building operation as well as to support renewable energy sources (RES) for the power grid reliability, quality, resilience, and dispatchability, this project developed and demonstrated a novel thermally activated building envelope system that integrates Phase Change Material (PCM)-based Thermal Energy Storage (TES) and the hydronic activation into the building envelope. The main objectives of this study are: 1) to design and laboraorty-test a novel thermally activated building envelope system that integrate PCM-based TES and the hydronic activation into building envelope, and 2) to exploit this new system to significantly reduce the energy cost of operating buildings and manage and support renewable energy sources (RES), e.g., solar and wind for the power grid reliability, quality, resilience, and dispatchability. To achieve the project objectives, a new low-cost, fire-retardant PCM packaging technology (CenoPCM) was developed specifically for high-volume building applications.

25 ENERGY STORAGE

Dynamic Modeling, Trajectory Optimization, and Linear Control of Cable-Driven Parallel Robots for Automated Panelized Building Retrofits

The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.

CDPR

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Lab-Scale Cable-Driven Parallel Robot Prototype for Automated Prefabricated Component Manipulation

This paper presents the design and evaluation of a lab-scale cable-driven parallel robot (CDPR) developed as a flexible platform for automated installation of prefabricated components onto exterior building envelopes. Traditional manual installation methods for prefabricated components, which depend on scaffolding, cranes, cherry pickers, and verbal coordination, are not only labor-intensive and error-prone but also face significant limitations in dense urban environments due to site access constraints. To address these challenges, we developed a lab-scale CDPR platform capable of autonomously transporting building envelope components from a designated pickup zone to their target installation location, minimizing the need for human intervention. This study describes the system’s mechanical design, actuation architecture, real-time feedback system, and control strategy of the CDPR, and evaluates its performance in a laboratory environment. The robot’s actuation system uses torque control for end-effector manipulation. The robot’s real-time pose feedback comes from a construction-grade total station and a wireless inertial measurement unit (IMU), which together support precise end-effector control. Experimental results demonstrate the successful integration of the hardware, sensing, state estimation, and control subsystems. Preliminary tests showed that our lab-scale prototype can position the end effector with an error of less than 3 mm, which is a level of precision not previously achieved by existing CDPRs in construction applications. The key findings are twofold: (1) torque-only control is necessary but not sufficient for minimizing final pose error, and (2) incorporating real-time pose feedback can achieve the desired placement accuracy.

Liu, Yifang [Oak Ridge National Laboratory (ORNL),

P2P: Point Cloud to Panel Layout Optimization

Building envelope retrofits, despite their benefits on enhancing energy efficiency, progress slowly due to high operating costs. Overclad panelized systems present an attractive solution to make retrofits affordable and easy to install. However, several stages of the retrofit process remain disconnected, suboptimal, and require significant human intervention. This study aims to bridge the gap between digital twin generation and overclad panel installation by automating the design of an optimal panel layout directly from a building envelope point cloud. In this end-to-end approach, the dimensional twin is generated by segmenting the facade point cloud. The facade then undergoes a three-step process to generate an optimized panel layout for integration with automated placement systems.

Philips, Nisha Deborah [ORNL]

Alchemy: A Model-Based Approach for 2D to 3D Autonomous Nuclear System Design

Engineering design of nuclear power plant (NPP) piping and equipment systems frequently bypasses crucial 2D system planning, instead moving straight to 3D modeling. This often leads to designs that exceed building envelope constraints, forcing expensive and time-consuming redesigns. When 2D modeling is employed, it typically involves labor-intensive manual workflows that convert 2D drawings into 3D models, resulting in inefficiencies and errors across design iterations. These workflows further suffer from poor software interoperability and dependence on proprietary software ecosystems, thereby contributing to schedule delays and cost overruns. This paper presents Alchemy, an autonomous framework that transforms 2D system definitions into Industry Foundation Classes (IFC)-compliant 3D building information models (BIMs) for expediting nuclear facility design at the conceptual preliminary phase. Using a model-based approach, the framework treats the 2D system diagram as the central reference model employed to automatically generate all subsequent outputs, ensuring consistency between the system definition and the resulting physical design. A web-based interface enables engineers to define hierarchical system topologies including associated equipment, geometric properties, and connectivity requirements. A two-phase equipment layout optimization algorithm automatically computes collision-free spatial configurations within predefined building envelopes. An artificial intelligence (AI)-assisted pipe routing module then generates orthogonal, collision-free routing paths, allowing the user to select either an A* search-based method or an Ant Colony Optimization (ACO)-based method. All outputs are authored natively in IFC format, relying on open-source technologies and standardized formats in order to ensure extensibility and eliminate proprietary software dependencies. The proposed framework is validated on two representative pressurized-water reactor (PWR)-based case studies, for which it autonomously generates IFC-compliant 3D models in minutes, drastically reducing workflows that typically require hours of manual effort. The generated model demonstrates topologically correct equipment placement, physically plausible spatial relationships, and collision-free pipe routing consistent with known PWR loop configurations. This work represents a foundational step toward digital engineering for nuclear facility preliminary design, with future ongoing development targeting design code compliance and expanded system complexity.

97 - MATHEMATICS AND COMPUTING

Technology pathways for energy- and water-efficient controlled environment agriculture: A review of technologies, implementation pathways, and regional use cases

Controlled Environment Agriculture (CEA) offers high-yield, climate-resilient food production, but high energy and resource demands challenge its sustainability. This paper synthesizes technologies that can improve outcomes across six categories—energy, CO 2 utilization, building envelope, hardware, water, and process—plus colocation strategies. We evaluate 80 technologies and define ten implementation pathways bundling complementary technologies to reduce energy use, optimize water consumption, and minimize emissions. Regional application is demonstrated through five U.S. case studies spanning different climates. A logic framework guides pathway selection for case studies based on climate, infrastructure, and regulatory context, informing context-sensitive technology deployment. Results show energy intensity reductions of 3–55 %, ranging from energy management programs to comprehensive lighting retrofits; water savings of 20–40 % through closed-loop recirculation; and emissions reductions of 3–100 %, with strategic energy management achieving 3–5 % and renewable electricity paired with electrified heating achieving up to 100 %. Text mining revealed that energy, hardware, and process technologies account for 91 % of literature coverage. Water, building envelope, and CO 2 utilization remain underexplored, indicating priorities for future research. This integrative approach to technology assessment supports growers, developers, and policymakers in aligning CEA system design with local conditions, improving resource efficiency and addressing gaps in cross-domain technology coverage.

Controlled environment agriculture

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI