Modeling Distributed Generation in California

In support of analysis for the biennial Integrated Energy Policy Report, the California Energy Commission and the National Renewable Energy Laboratory have partnered to study the growth of distributed energy resources in California. This study involves the use of National Renewable Energy Laboratory's Distributed Generation Market Demand model, available at https://www.nrel.gov/analysis/dgen/, to project statewide adoption of distributed photovoltaics and paired storage. Key outcomes of the collaboration include: • Improved representation of California building stock, load profiles, historical adoption, and tariffs, including the net billing tariff, in the dGen model; • Trained CEC staff members to use and adapt the dGen model for their specific needs; • Developed a methodology for representing emerging consumer segments to potentially adopt distributed energy resources, including low-income, multifamily, and renter-occupied buildings; • Forecasted solar photovoltaic and paired storage growth in California using a common set of modeling parameters. This report describes the multiyear effort, which includes a discussion of: • Methodology and data employed in adapting the Distributed Generation Market Demand model for California to forecast solar photovoltaic and storage statewide through 2040; • Steps taken to modify the base model to forecast solar photovoltaic adoption in emerging market segments such as multifamily or renter-occupied homes or both; • Future enhancements of the model.

14 SOLAR ENERGY↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analytics and Visualization of Energy Systems for Critical Infrastructure Insights

Modernization of energy systems including transportation facilities provides opportunities for increased efficiency, expansion of commerce and meeting industry and federal goals. A significant increase in electrical demand is projected to meet these needs, which concentrates at facilities such as airports. For example, Xcel Energy working with two airports in their service area recently published information projecting an up to fivefold increase in electricity demand in the next 25 years [1]. Concurrently, the US Government Accountability Office (GAO) recently surveyed 30 commercial service airports identifying more than 300 outages of more than 5 minutes between 2015 and 2022 [2]. Power, reliability, and resilience planning becomes more important to safely maintain operations and the flow of commerce with fewer energy carriers providing necessary energy to safely move passengers and goods. NREL proposes to develop methodologies to allow owners, utilities, and federal agencies to dynamically analyze, forecast, and manage energy loads at airports, focused upon maintaining the flow of commerce in an efficient, sustainable, and resilient way. To address these energy challenges, a suite of technologies and methodologies can be leveraged to validate concepts, inform design, de-risk solutions and optimize energy management during deployment. These technologies include digitalization of energy systems, microgrid methodologies, and related energy technologies for building and vehicle loads. [1] Electrifying Airport Ecosystems - https://www.enterprisemobility.com/content/dam/enterpriseholdings/marketing/innovation-in-mobility/vehicle-innovation/airport-electrification-study-full-report-2024.pdf [2] Airport Infrastructure: Selected Airport's Efforts to Enhance Electrical Resilience https://www.gao.gov/products/gao-23-105203.

critcal infrastructure↗

HP-FLEX MPC v0.1.0

HP-FLEX MPC is control software developed by Lawrence Berkeley National Laboratory with support from the California Energy Commission (CEC) through EPIC-19-301. HP-FLEX aims to provide load flexibility for heat pumps (HPs) in response to dynamic grid signals (including Time-of-Use, Dynamic Pricing, and Critical Peak Pricing) while maintaining thermostat temperatures within user-specified bounds. The software includes a system-identification module, which models the dynamics of the building envelope with thermostat data, and a control module based on a model predictive controller (MPC) to make optimal decisions. HP-FLEX receives forecasts of outdoor air temperature, solar irradiation, and internal gain (if available), as well as trajectories of energy price, temperature lower and upper bounds over a prediction horizon. It then optimizes heating and cooling capacities to minimize energy cost and peak power (with a user-defined weight on peak power) over the prediction horizon, while maintaining room air temperature within the temperature constraints, and outputs the optimal thermostat setpoints.

Kim, Donghun↗

Potential Adoption and Benefits of Co-Optimized Multimode Engines and Fuels for U.S. Light-Duty Vehicles

Exploring a diverse portfolio of technologies for decarbonization is crucial to understanding the potential impacts of different technological solutions and their associated environmental implications. Using high-octane, high-sensitivity biofuel blends in co-optimized multimode engines can increase engine efficiency and reduce vehicle emissions. Here, the multimode engine research focuses on the benefits of light-duty vehicle engines, which can operate in multiple modes depending on the vehicle's load. Low-temperature combustion can improve efficiency and reduce emissions (such as those from oxides of nitrogen and particulate matter) during low-load operation, while spark ignition performance is maintained in high-load operation. These advanced engines can be optimized to run on blends of biobased fuels. This analysis models scenarios for potential market adoption of co-optimized multimode vehicles fueled by three different bioblendstocks: ethanol, isopropanol, and isobutanol. An integrated modeling approach is used to forecast the energy and environmental impacts of the deployment of co-optimized multimode vehicles and fuels in the light-duty sector over the 2020-to-2050 time horizon. The multidisciplinary approach combines vehicle sales modeling, system dynamics modeling of the biorefining industry, and life cycle assessment to estimate the emissions and energy benefits. The models consider market forces such as consumer preferences for vehicle attributes, biofuel supply and demand dynamics subject to biorefinery capacity build-out and bioresource constraints, and forecasted changes to the U.S. bulk energy system over time. Market adoption of co-optimized vehicles is evaluated across a wide parameter space for incremental vehicle cost and engine efficiency improvement. This analysis reveals that the deployment of co-optimized multimode fuels and vehicles results in up to a 5% reduction in annual sector-wide life cycle greenhouse gas (GHG) emissions by 2050, relative to a business-as-usual scenario, but is also indicates environmental trade-offs, such as higher life cycle water-use. Emission benefits could potentially increase beyond 2050, as the new technologies penetrate the market and gain a foothold. Results also show that, under certain circumstances, vehicles with engines co-optimized for use with high-octane, high-sensitivity biofuel blends can be cost-competitive with conventional gasoline, while reducing GHG emissions. Our modeling results indicate that co-optimized multimode fuels and engines can be strategically leveraged in tandem with electrification to decarbonize the light-duty sector. Co-optimized vehicles could play a role in the early years of the time horizon, while electric vehicles (EVs) could become more competitive in the later years, highlighting the complementary benefits of these technologies for GHG reductions.

Oke, Doris↗

State Requirements for Electric Distribution System Planning

Utilities have conducted distribution planning since they first began building and operating electricity systems. But filing these plans for regulatory and stakeholder review is a relatively recent phenomenon. This report summarizes legislative and regulatory requirements for regulated electric utilities to file some type of distribution system plan in 20 U.S. jurisdictions. Some plans focus on expedited cost recovery for certain types of distribution system improvements; other plans focus on investments for grid modernization or distributed energy resources. Increasingly, states are adopting requirements for Integrated Distribution Plans. Such plans provide holistic grid investment strategies that address state and local policies and increasing complexity at the grid edge. The report covers the following topics for distribution system plans, highlighting advanced practices: -State goals and objectives -Procedural requirements -Forecasting loads and distributed energy resources -Hosting capacity analysis -Baseline information requirements -Grid modernization strategy -Grid needs assessment -Non-wires solutions -Reliability and resilience analyses -Stakeholder engagement -Equity -Pilots -Coordination with other planning processes The report includes links to legislation; regulatory requirements, proceedings, and orders; and filed utility plans. The U.S. Department of Energy’s Office of Electricity provided funding support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of automated data-driven feature extraction and selection methods for practical and scalable building energy consumption prediction models

Here, this study quantifies the impact of automated feature engineering methods (feature extraction and selection) on the quality and accuracy of machine learning models that predict building energy consumption. The case study compares model performance for three main scenarios: baseline (no feature extraction and selection), feature extraction only, and feature extraction combined with feature selection (filter and/or wrapper methods) for fully trained machine learning models for 200 metered/sub-metered energy measurements across 118 real buildings. For consistency, the same machine learning model architecture (a black box deep learning neural network with probabilistic forecast output) was used for all scenarios. Based on results, all feature engineering methods provided noticeable prediction accuracy improvements (e.g., 29%-68% median prediction improvement) compared to baseline scenarios. However, in this application, feature selection methods provide little practical value due to their limited performance gains and high computational cost. Smarter algorithm development supported by better computational environments will be needed before feature selection methods can reliably and efficiently improve predictive model performance.

97 MATHEMATICS AND COMPUTING↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗