Search NASA⌕ Search

SEARCH · Search NASA

Results for “bundle adjustment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Orthographic Stereo Correlator on the Terrain Model for Apollo Metric Images

A stereo correlation method on the object domain is proposed to generate the accurate and dense Digital Elevation Models (DEMs) from lunar orbital imagery. The NASA Ames Intelligent Robotics Group (IRG) aims to produce high-quality terrain reconstructions of the Moon from Apollo Metric Camera (AMC) data. In particular, IRG makes use of a stereo vision process, the Ames Stereo Pipeline (ASP), to automatically generate DEMs from consecutive AMC image pairs. Given camera parameters of an image pair from bundle adjustment in ASP, a correlation window is defined on the terrain with the predefined surface normal of a post rather than image domain. The squared error of back-projected images on the local terrain is minimized with respect to the post elevation. This single dimensional optimization is solved efficiently and improves the accuracy of the elevation estimate.

Terrain Model↗

Mid-Air Range-Visual-Inertial Estimator Initialization for Micro Air Vehicles

Monocular Visual-Inertial Odometry (VIO) has become ubiquitous for navigation of autonomous Micro Air Vehicles (MAVs). Yet, state-of-the-art VIO is still very failure- prone, which can have dramatic consequences. To prevent this, VIO must be able to re-initialize in mid-air, either during a free fall or on a constant horizontal velocity trajectory after attitude control has been re-established. However, for both of these trajectories, the visual scale cannot be observed with VIO batch initializers because of the absence of acceleration change. We propose to use a small and lightweight laser range finder and a scene facet model to initialize vision-based navigation at the right scale under any motion condition and over any scene structure. This new range constraint is integrated into a visual-inertial bundle adjustment initializer. We demonstrate in simulation and real data how this approach can address mid-air state estimation failure in real-time and analyze the sensitivity of estimators to initial state errors.

Brockers, Roland↗

Vision-based Velocimetry over Unknown Terrain with a Low-Noise IMU

This paper presents a novel approach to terrain-relative navigation with a visual camera and Inertial Measurement Unit (IMU). The proposed algorithm uses an Extended Kalman Filter (EKF) to combine an IMU propagated state estimate with batch correction estimates computed over a sliding window of measurements. The batch correction algorithm follows the Maximum Likelihood Estimation (MLE) approach used in other Bundle Adjustment systems. Unlike other systems, the proposed system parameterizes the state over the entire window in terms of the state at a single epoch. By ignoring IMU error over the window duration, we obtain a state epoch MLE that jointly estimates the epoch state and terrain parameters with drastically reduced computationally cost. This paper presents the general architecture which can be adapted for various state parameterizations and measurement inputs. For space applications with high-accuracy IMUs, the reduction in computational cost comes with only a modest increase in estimation errors. The increase in error is quantified via a linear covariance analysis presented in this paper. Furthermore, we present simulation results which show the applicability of this algorithm to planetary landing problems.

San Martin, A. Miguel↗

Development of the Model Deformation System at the National Transonic Facility

This paper describes the model deformation system currently being developed for the National Transonic Facility at NASA Langley Research Center. The photogrammetry system uses up to eight network cameras that are time synced with an external hardware trigger. Camera extrinsics are calculated per frame with a bundle adjustment process with coded targets painted to the floor and walls of the test section. We describe our algorithm pipeline including the coded target system for target correspondence between camera views. We also present our future plans for modernizing the system.

Timothy Fahringer↗

Development of the model deformation system at the National Transonic Facility

This paper describes the model deformation system currently being developed for the National Transonic Facility at NASA Langley Research Center. The photogrammetry system uses up to eight network cameras that are time synced with an external hardware trigger. Camera extrinsics are calculated per frame with a bundle adjustment process with coded targets painted to the floor and walls of the test section. We describe our algorithm pipeline including the coded target system for target correspondence between camera views. We also present our future plans for modernizing the system.

Timothy Fahringer↗

New Strategies for Time Delay Estimation during System Calibration for UAV-Based GNSS/INS-Assisted Imaging Systems

The need for accurate 3D spatial information is growing rapidly in many of today’s key industries, such as precision agriculture, emergency management, infrastructure monitoring, and defense. Unmanned aerial vehicles (UAVs) equipped with global navigation satellite systems/inertial navigation systems (GNSS/INS) and consumer-grade digital imaging sensors are capable of providing accurate 3D spatial information at a relatively low cost. However, with the use of consumer-grade sensors, system calibration is critical for accurate 3D reconstruction. In this study, ‘consumer-grade’ refers to cameras that require system calibration by the user instead of by the manufacturer or other high-end laboratory settings, as well as relatively low-cost GNSS/INS units. In addition to classical spatial system calibration, many consumer-grade sensors also need temporal calibration for accurate 3D reconstruction. This study examines the accuracy impact of time delay in the synchronization between the GNSS/INS unit and cameras on-board UAV-based mapping systems. After reviewing existing strategies, this study presents two approaches (direct and indirect) to correct for time delay between GNSS/INS recorded event markers and actual time of image exposure. Our results show that both approaches are capable of handling and correcting this time delay, with the direct approach being more rigorous. When a time delay exists and the direct or indirect approach is applied, horizontal accuracy of 1–3 times the ground sampling distance (GSD) can be achieved without either the use of any ground control points (GCPs) or adjusting the original GNSS/INS trajectory information.

47 OTHER INSTRUMENTATION↗

Accuracy Analysis on Large Blocks of High Resolution Images

Although high altitude frequencies effects are removed at the time of basic image generation, low altitude (Yaw) effects are still present in form of affinity/angular affinity. They are effectively removed by additional parameters. Bundle block adjustment based on properly weighted ephemeris/altitude quaternions (BBABEQ) are not enough to remove the systematic effect. Moreover, due to the narrow FOV of the HRSI, position and altitude are highly correlated making it almost impossible to separate and remove their systematic effects without extending the geometric model (Self-Calib.) The systematic effects gets evident on the increase of accuracy (in terms of RMSE at GCPs) for looser and relaxed ground control at the expense of large and strong block deformation with large residuals at check points. Systematic errors are most freely distributed and their effects propagated all over the block.

Passini, Richardo M.↗

Automated Data Production For A Novel Airborne Multiangle Spectropolarimetric Imager (AIRMSPI)

A novel polarimetric imaging technique making use of rapid retardance modulation has been developed by JPL as a part of NASA's Instrument Incubator Program. It has been built into the Airborne Multiangle SpectroPolarimetric Imager (AirMSPI) under NASA's Airborne Instrument Technology Transition Program, and is aimed primarily at remote sensing of the amounts and microphysical properties of aerosols and clouds. AirMSPI includes an 8-band (355, 380, 445, 470, 555, 660, 865, 935 nm) pushbroom camera that measures polarization in a subset of the bands (470, 660, and 865 nm). The camera is mounted on a gimbal and acquires imagery in a configurable set of along-track viewing angles ranging between +67 deg and -67 deg relative to nadir. As a result, near simultaneous multi-angle, multi-spectral, and polarimetric measurements of the targeted areas at a spatial resolution ranging from 7 m to 20 m (depending on the viewing angle) can be derived. An automated data production system is being built to support high data acquisition rate in concert with co-registration and orthorectified mapping requirements. To date, a number of successful engineering checkout flights were conducted in October 2010, August-September 2011, and January 2012. Data products resulting from these flights will be presented.

Multi-angle↗

Conceptual Design of a Water Tank Critical Facility for SPARC

Critical experiments, sometimes referred to zero-power reactors, are crucial tools in developing and validating nuclear physics predictions and thus an indispensable capability to ensure criticality safety during all parts of the nuclear fuel cycle and in reducing uncertainties in reactor physics predictions toward optimizing nuclear energy production. The System Physics Advanced Reactor Facility (SPARC) project was recently initiated to enable large-scale criticality experiments using a horizontal split table machine well suited toward solid core materials systems (fuel, moderator, reflector). The facility selected for this mission was a former pool-type research reactor building and thus also well suited toward a second critical experiment capability able to house full-size light-water reactor (LWR) fuel bundles. A conceptual design study was undertaken to review past water tank critical experiments used for LWR physics experiments and to develop an early engineering design for a new critical assembly tank (CAT). The work described here shows that a relatively simple CAT concept can be constructed and deployed in the SPARC facility to meet the urgent demands for new critical experiments on advanced LWR fuel bundles designs. The SPARC facility layout is conducive to the receipt and upending of LWR fuel bundles using existing containers and equipment from the LWR industry. The facility’s overhead crane can then be used to handle fuel bundles and place them in a vertical storage rack or in the CAT for critical experiments, both of which fit within the building’s “open basement” alongside other equipment planned for SPARC and the horizontal split table. A slightly lower area in the basement can serve as a large drain tank so that fail-safe valves drain the CAT reactor tank for safe shutdown. Neutronic configurations were determined where a 3 × 3 array of fuel bundles can be surrounded by full-length “loose rods” to adjust reactivity so that critical is achieved when the bundles are fully submerged. Viable configurations were determined for both pressurized- and boiling-water-reactor-type fuel bundles. This design concept was used to develop an early planning basis for establishing the CAT capability alongside the otherwise planned SPARC project in order to help streamline the process. Recent presidential executive orders have highlighted the need to achieve power uprates in LWR plants and the CAT capability will be a crucial element of these initiatives. Based on the work described herein, it is recommended that an earnest and timely project begin in order to establish this urgently needed capability.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis and optical properties of GaN micro/nanocone bundles on copper wafers

GaN micro/nanocone bundles with controllable size and density have been synthesized on Cu or Cu{sub 95}In{sub 5} alloy wafers using a modified thermal-evaporation process. The size and density of GaN cone bundles could be efficiently controlled by adjusting growth temperatures and the components of metal substrates. The structure and morphology of the as-synthesized GaN cones were characterized using X-ray diffraction, scanning electron microscopy and transmission electron microscopy. The as-synthesized micro/nanocones are single crystals with a hexagonal wurtzite structure, growing along the [101-bar1] direction. The growth process follows a vapor-liquid-solid mechanism. The dependence of photoluminescence property on the size and density of GaN cone bundles at room temperature was also investigated.

36 MATERIALS SCIENCE↗

Scale factor gage for fiber optics inspection device

Flexible wire device, fastened along outside of fiber bundle from viewing portion to tip, positions calibrated adjustable gage in field of view. Scale factor is determined from known magnification characteristics of fiber optics system or from graduations on gage tip.

Mcmahon, W.↗

Shape deformation of the organ of Corti associated with length changes of outer hair cell

Cochlear outer hair cells (OHC) are commonly assumed to function as mechanical effectors as well as sensory receptors in the organ of Corti (OC) of the inner ear. OHC in vitro and in organ explants exhibit mechanical responses to electrical, chemical or mechanical stimulation which may represent an aspect of their effector process that is expected in vivo. A detailed description, however, of an OHC effector operation in situ is still missing. Specifically, little is known as to how OHC movements influence the geometry of the OC in situ. Previous work has demonstrated that the motility of isolated OHCs in response to electrical stimulation and to K(+)-gluconate is probably under voltage control and causes depolarisation (shortening) and hyperpolarization (elongation). This work was undertaken to investigate if the movements that were observed in isolated OHC, and which are induced by ionic stimulation, could change the geometry of the OC. A synchronized depolarization of OHC was induced in guinea pig cochleae by exposing the entire OC to artificial endolymph (K+). Subsequent morphometry of mid-modiolar sections from these cochleae revealed that the distance between the basilar membrane (BM) and the reticular lamina (RL) had decreased considerably. Furthermore, in the three upper turns OHC had significantly shortened in all rows. The results suggest that OHC can change their length in the organ of Corti (OC) thus deforming the geometry of the OC. The experiments reveal a tonic force generation within the OC that may change the position of RL and/or BM, contribute to damping, modulate the BM-RL-distance and control the operating points of RL and sensory hair bundles. Thus, the results suggest active self-adjustments of cochlear mechanics by slow OHC length changes. Such mechanical adjustments have recently been postulated to correspond to timing elements of animal communication, speech or music.

Non-NASA Center↗

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

Influence of Axial Power Distributions on Rod-to-wall Gap

In a scaled-down (3 x 3, 4 x 4, 5 x 5 or 6 x 6) rod bundle thermal hydraulic experiment, channel walls were often applied to surround the experimental rod bundle and provide a hydraulic flow boundary for the experiments. However, in the actual PWR (Pressurized Water Reactor), there are no walls surrounding the rod bundle fuel assembly. These non-representative walls can lead to non-prototypical conditions in the rod bundle experiments. There are several researches about the wall effects in rod bundle experiments. Based on hydraulic consideration, Zang developed a wall effect factor by subchannel analysis method to investigate the wall effects of different scale rod bundles. He did not pay attention to the wall effects in thermal aspects. Li studied the wall effects of different scale rod bundles of tight arrangement spiral-fin fuel assembly by CFD. The existing researches mostly focus on the wall effects of different scale rod bundles. There are very few, if any at all, studies focus on how to avoid or minimize wall effects through proper experimental design by adjusting the rod-to-wall gap (the gap between the channel wall and outer rod wall) for rod bundles of various scales. In addition, the axial power distribution is different in different periods of the life cycle in the PWR core. For example, it usually is outlet peak power distribution in the axial direction at the beginning of life span. However, it may turn to the inlet peak power distribution when the control rods are pulled out from the high burn up of fuel in the reactor core. Both flow dynamics and heat transfer mechanism change depending on various axial power distributions. Subsequently, it is important to study the impacts of the wall effects on flow and heat transfer with different axial power distributions in rod bundle experiments. That is, in the evaluation of rod-to-wall gap in rod bundle experiments, the influence of axial power distributions should be examined. In this paper, the rod-to-wall gap was calculated in axially uniform and non-uniform power, including inlet peak, cosine, and exit peak heat flux distributions. The rod-to-wall gap calculation results were then compared with respect to two different criterion: the average fluid temperature and the maximum wall temperature criterion, to study the influence of axial heat flux profile on radial thermal distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Modular Tissue Phantom for Evaluating Vascular Access Devices

Central vascular access (CVA) may be critical for trauma care and stabilizing the casualty. However, it requires skilled personnel, often unavailable during remote medical situations and combat casualty care scenarios. Automated CVA medical devices have the potential to make life-saving therapeutics available in these resource-limited scenarios, but they must be properly designed. Unfortunately, currently available tissue phantoms are inadequate for this use, resulting in delayed product development. Here, we present a tissue phantom that is modular in design, allowing for adjustable flow rate, circulating fluid pressure, vessel diameter, and vessel positions. The phantom consists of a gelatin cast using a 3D-printed mold with inserts representing vessels and bone locations. These removable inserts allow for tubing insertion which can mimic normal and hypovolemic flow, as well as pressure and vessel diameters. Trauma to the vessel wall is assessed using quantification of leak rates from the tubing after removal from the model. Lastly, the phantom can be adjusted to swine or human anatomy, including modeling the entire neurovascular bundle. Overall, this model can better recreate severe hypovolemic trauma cases and subject variability than commercial CVA trainers and may potentially accelerate automated CVA device development.

59 BASIC BIOLOGICAL SCIENCES↗

Minor actinide transmutation in thorium and uranium matrices in heavy water moderated reactors

The irradiation of Th{sup 232} breeds fewer of the problematic minor actinides (Np, Am, Cm) than the irradiation of U{sup 238}. This characteristic makes thorium an attractive potential matrix for the transmutation of these minor actinides, as these species can be transmuted without the creation of new actinides as is the case with a uranium fuel matrix. Minor actinides are the main contributors to long term decay heat and radiotoxicity of spent fuel, so reducing their concentration can greatly increase the capacity of a long term deep geological repository. Mixing minor actinides with thorium, three times more common in the Earth's crust than natural uranium, has the additional advantage of improving the sustainability of the fuel cycle. In this work, lattice cell calculations have been performed to determine the results of transmuting minor actinides from light water reactor spent fuel in a thorium matrix. 15-year-cooled group-extracted transuranic elements (Np, Pu, Am, Cm) from light water reactor (LWR) spent fuel were used as the fissile component in a thorium-based fuel in a heavy water moderated reactor (HWR). The minor actinide (MA) transmutation rates, spent fuel activity, decay heat and radiotoxicity, are compared with those obtained when the MA were mixed instead with natural uranium and taken to the same burnup. Each bundle contained a central pin containing a burnable neutron absorber whose initial concentration was adjusted to have the same reactivity response (in units of the delayed neutron fraction β) for coolant voiding as standard NU fuel. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal hydraulic issues of HTGR helical tube once through steam generator: methods and applications - 18478

High Temperature Gas-cooled Reactor (HTGR) usually uses helical tube once through steam generators (OTSG) for steam generation. The most concerned thermal hydraulic issues of HTGR helical tube OTSG are two phase flow instability and temperature non-uniformity. One dimensional transient code and two dimensional code are developed to investigate these two issues. The codes are briefly introduced, then the results are briefly presented and discussed. The main conclusions are that there does not appear two phase instability for all the working conditions for the steam generator of HTR-PM. Tube plugging can introduce temperature non-uniformity in the tube bundle. The temperature non-uniformity can be evened by changing the flow rate distribution through adjusting the throttle orifice at the inlet. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗