Search NASA⌕ Search

SEARCH · Search NASA

Results for “bypass ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Pathways for methane emissions and oxidation that influence the net carbon balance of a subtropical cypress swamp

We evaluated the major pathways for methane emissions from wetlands to the atmosphere at four wetland sites in the Big Cypress National Preserve in southwest Florida. Methane oxidation was estimated based on the d13C-CH4 of surface water, porewater, and bubbles to evaluate mechanisms that limit surface water emissions. Spatially-scaled methane fluxes were then compared to organic carbon burial rates. The pathway with the lowest methane flux rate was diffusion from surface waters (3.50 ± 0.22 mmol m-2 d-1). Microbial activity in the surface water environment and/or shallow oxic sediment layer oxidized 26 ± 3% of the methane delivered from anerobic sediments to the surface waters. The highest rates of diffusion were observed at the site with the lowest extent of oxidation. Ebullition flux rates were 2.2 times greater than diffusion and more variable (7.79 ± 1.37 mmol m-2 d-1). Methane fluxes from non-inundated soils were 1.6 times greater (18.4 ± 5.14 mmol m-2 d-1) than combined surface water fluxes. Methane flux rates from cypress knees (emergent cypress tree root structures) were 3.7 and 2.3 times higher (42.0 ± 6.33 mmol m-2 d-1) than from surface water and soils, respectively. Cypress knee flux rates were highest at the wetland site with the highest porewater methane partial pressure, suggesting that the emergent root structures allow methane produced in anaerobic sediment layers to bypass oxidation in aerobic surface waters or shallow sediments. Scaled across the four wetlands, emissions from surface water diffusion, ebullition, non-inundated soils, and knees contributed to 14 ± 2%, 25 ± 6%, 34 ± 10%, and 26 ± 5% of total methane emissions, respectively. When considering only the three wetlands with cypress knees present, knee emissions contributed to 39 ± 5% of the total scaled methane emissions. Finally, the molar ratio of CH4 emissions to OC burial ranged from 0.03 to 0.14 in the wetland centers indicating that all four wetland sites are net sources of atmospheric warming potential on 20-100 yr timescales, but net sinks over longer time scales (500 yr) with the exception of one wetland site that was a net source even over 500 yr time scales.

Ward, Nicholas D.↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Iodide Double Perovskites and the Limits of their Structural Stability

AbstractWhile halide double perovskites A2M(I)M(III)X6 have attracted significant attention, examples involving iodides are rare. We examine the limits of the structural stability of iodide double perovskites, presenting the synthesis and single‐crystal structures of Cs2NaScI6 and Cs2NaYI6. Bypassing the common expectation that iodides have small band gaps, these compounds display optical gaps of 3.10 eV [M(III) = Sc] and 3.65 eV [M(III) = Y]. Cs2NaScI6 is the only iodide double perovskite to exhibit a cubic crystal structure at room temperature. Density functional theory‐based electronic structure calculations help understand the role of competing Cs3M(III)2I9 (3 : 2 : 9) phases and provide possible reasons for why iodide double perovskites based around In(III), Sb(III) and Bi(III) cations have proved elusive. We confirm design rules for halide double perovskites based around concepts of the tolerance factor and the radius ratio of the smaller, trivalent ion, but also point to situations such as what is observed for Cs2NaScI6 where a double perovskite can be trapped in a metastable structure.

Mulligan, Anya S.↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the modeling of near-wall interphase heat transfer in porous media models of Pebble Bed Reactors

Here, this work aims to improve capabilities for modeling localized effects in porous media models of Pebble Bed Reactors. The wall-channeling effect is the primary local phenomenon of interest in a PBR, where the presence of the reflector wall disrupts the pebble packing, causing the pebbles near the wall to pack less efficiently and creating large void regions. Accurate modeling of the near-wall region is important as it will affect core bypass flow and temperature predictions. Porous media models are commonly used for design scoping and plant-level simulations of PBRs. Although these models have some capabilities to model the near-wall region, the correlations that are available in porous media codes are often inaccurate when a multi-region model is used to discretize the near-wall region. This work employs a high-to-low analysis to study the accuracy of available interphase heat transfer closures. NekRS, a spectral element computational fluid dynamics code, is used to perform Large Eddy Simulations. These LES simulation results are compared to porous media model results from the Pronghorn porous media code. The friction term of the KTA drag closure is first improved, reducing the error in the prediction of the near-wall velocity from over 50% to less than 5%. This is combined with improvements to the form term from previous works to produce a drag closure that is capable of accurately modeling the wall-channeling effect across a variety of flow conditions. The Nusselt number predictions of several heat transfer correlations are compared to the high-fidelity results where it is found that the KTA heat transfer correlation is capable of accurately predicting the local Nusselt numbers that were determined in the high-fidelity simulation. Comparison of the radial solid temperature profiles, however, reveal discrepancies between NekRS and Pronghorn. It is discovered that the implementation of the interphase heat transfer coefficient that exists in many current porous media codes is not valid when local porosities are modeled. Instead, it is suggested that the interphase heat transfer coefficient should be dependent on the local porosity, the Nusselt number, and the local solid surface-to-volume ratio. Implementation of this change produces improvement in the agreement between the results obtained by NekRS and Pronghorn while using the KTA heat transfer correlation.

interphase heat transfer↗

Dissolution of Fluoride Salts in Hanford Tank Waste

The Direct Feed High-Level Waste (DFHLW) strategy seeks to bypass the Hanford Waste Treatment and Immobilization Plant Pretreatment Facility while retaining some processing functions to maximize waste feed loading and minimize high-level waste (HLW) waste volume. The DFHLW flowsheet needs leaching, washing, and solids concentration operations either in new or existing tanks. The effectiveness and efficiency of sludge washing has a substantial impact on DST space, mission duration, and the evaporation and low-activity waste (LAW) treatment operations required by these large wash-water additions. One target species requiring washing is fluoride. The HLW glass composition limits for fluorine drive operations to dissolve fluoride-bearing salts into the LAW fraction and thereby maximize waste loading in HLW glass. The fluoride in many high-level wastes at Hanford is predominantly in the form of fluoride-salt precipitates: villiaumite (NaF), kogarkoite (Na 3 FSO 4 ), and natrophosphate (Na 7 F(PO 4 ) 2 ·19H 2 O). Fluoride produces melter off-gas that creates corrosion risk in the off-gas system piping, while the sulfate and phosphate in the fluoride double salts kogarkoite and natrophosphate can be detrimental to glass waste loading. Fluoride salts are sparingly soluble, with solubilities ranging from approximately 40 to 130 kg per kL of pure water, and the dissolution kinetics of the three fluoride salts are not well known. Unexpected delays in a tank dissolution process could be encountered as a result of the lack of information about dissolution rates. In addition, if the double salts show transient non-stoichiometric dissolution of fluoride versus phosphate or sulfate, unexpectedly high concentrations of one of these other constituents could be produced. Washington River Protection Solutions authorized Pacific Northwest National Laboratory to collect the available data for fluoride salt dissolution rate, provide a scoping estimate of dissolution time if possible, and identify gaps in the understanding and predictive capability for estimating dissolution time. Open literature and Hanford reports were reviewed to document, understand, and (where possible) evaluate limitations on fluoride salt equilibria and dissolution kinetics, including both mass transport and surface reaction rate. Scoping estimates of dissolution time were made for mass-transfer-controlled dissolution of spherical particles of fluoride salts suspended in liquid. This is not the only potential governing mechanism; dissolution could be substantially slower if the surface reaction rate (the rate of release of ions from the surface) is the controlling mechanism. When the minimum amount of water for complete dissolution is used and the slip velocity between the liquid and suspended particles is less than or equal to the terminal settling velocity, the estimated mass-transfer rates allow 0.1 mm particles of fluoride salt to dissolve in minutes at 25 °C in water containing no other dissolved salts. Much larger solids, such as the 6-mm chunks that have been seen in heels, could take a few hours to more than a week to dissolve. The actual dissolution times will depend strongly on the actual slip velocity, the extent of particle suspension, constraint by surface reaction rates, the ratio of solvent to solid, and the presence of common ions that shift the solubility equilibria to restrict dissolution of fluoride salts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗