Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration and fitting methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A flight evaluation of a trailing anemometer for low-speed calibrations of airspeed systems on research aircraft

Research airspeed systems on three low-speed general aviation airplanes were calibrated by the trailing anemometer method. Each airplane was fitted with an NASA pitot-static pressure tube mounted on either a nose or wing boom. The uncalibrated airspeed systems contained residual static-pressure position errors which were too large for high-accuracy flight research applications. The trailing anemometer calibration was in agreement with the tower flyby calibration for the one aircraft for which the comparison was made. The continuous deceleration technique for the trailing anemometer method offers reduced test time with no appreciable loss of accuracy for airspeed systems with pitot-static system lag characteristics similar to those described.

Fisher, B. D.↗

Improved Regression Analysis of Temperature-Dependent Strain-Gage Balance Calibration Data

An improved approach is discussed that may be used to directly include first and second order temperature effects in the load prediction algorithm of a wind tunnel strain-gage balance. The improved approach was designed for the Iterative Method that fits strain-gage outputs as a function of calibration loads and uses a load iteration scheme during the wind tunnel test to predict loads from measured gage outputs. The improved approach assumes that the strain-gage balance is at a constant uniform temperature when it is calibrated and used. First, the method introduces a new independent variable for the regression analysis of the balance calibration data. The new variable is designed as the difference between the uniform temperature of the balance and a global reference temperature. This reference temperature should be the primary calibration temperature of the balance so that, if needed, a tare load iteration can be performed. Then, two temperature{dependent terms are included in the regression models of the gage outputs. They are the temperature difference itself and the square of the temperature difference. Simulated temperature{dependent data obtained from Triumph Aerospace's 2013 calibration of NASA's ARC-30K five component semi{span balance is used to illustrate the application of the improved approach.

wind tunnel testing↗

Hidden Connections between Regression Models of Strain-Gage Balance Calibration Data

Hidden connections between regression models of wind tunnel strain-gage balance calibration data are investigated. These connections become visible whenever balance calibration data is supplied in its design format and both the Iterative and Non-Iterative Method are used to process the data. First, it is shown how the regression coefficients of the fitted balance loads of a force balance can be approximated by using the corresponding regression coefficients of the fitted strain-gage outputs. Then, data from the manual calibration of the Ames MK40 six-component force balance is chosen to illustrate how estimates of the regression coefficients of the fitted balance loads can be obtained from the regression coefficients of the fitted strain-gage outputs. The study illustrates that load predictions obtained by applying the Iterative or the Non-Iterative Method originate from two related regression solutions of the balance calibration data as long as balance loads are given in the design format of the balance, gage outputs behave highly linear, strict statistical quality metrics are used to assess regression models of the data, and regression model term combinations of the fitted loads and gage outputs can be obtained by a simple variable exchange.

Ulbrich, Norbert↗

Archetype-based Redshift Estimation for the Dark Energy Spectroscopic Instrument Survey

We present a computationally efficient galaxy archetype-based redshift estimation and spectral classification method for the Dark Energy Survey Instrument (DESI) survey. The DESI survey currently relies on a redshift fitter and spectral classifier using a linear combination of principal component analysis–derived templates, which is very efficient in processing large volumes of DESI spectra within a short time frame. However, this method occasionally yields unphysical model fits for galaxies and fails to adequately absorb calibration errors that may still be occasionally visible in the reduced spectra. Our proposed approach improves upon this existing method by refitting the spectra with carefully generated physical galaxy archetypes combined with additional terms designed to absorb data reduction defects and provide more physical models to the DESI spectra. We test our method on an extensive data set derived from the survey validation (SV) and Year 1 (Y1) data of DESI. Our findings indicate that the new method delivers marginally better redshift success for SV tiles while reducing catastrophic redshift failure by 10%–30%. At the same time, results from millions of targets from the main survey show that our model has relatively higher redshift success and purity rates (0.5%–0.8% higher) for galaxy targets while having similar success for QSOs. These improvements also demonstrate that the main DESI redshift pipeline is generally robust. Additionally, it reduces the false-positive redshift estimation by 5%–40% for sky fibers. We also discuss the generic nature of our method and how it can be extended to other large spectroscopic surveys, along with possible future improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model Robust Calibration: Method and Application to Electronically-Scanned Pressure Transducers

This article presents the application of a recently developed statistical regression method to the controlled instrument calibration problem. The statistical method of Model Robust Regression (MRR), developed by Mays, Birch, and Starnes, is shown to improve instrument calibration by reducing the reliance of the calibration on a predetermined parametric (e.g. polynomial, exponential, logarithmic) model. This is accomplished by allowing fits from the predetermined parametric model to be augmented by a certain portion of a fit to the residuals from the initial regression using a nonparametric (locally parametric) regression technique. The method is demonstrated for the absolute scale calibration of silicon-based pressure transducers.

Walker, Eric L.↗

AVIRIS study of Death Valley evaporite deposits using least-squares band-fitting methods

Minerals found in playa evaporite deposits reflect the chemically diverse origins of ground waters in arid regions. Recently, it was discovered that many playa minerals exhibit diagnostic visible and near-infrared (0.4-2.5 micron) absorption bands that provide a remote sensing basis for observing important compositional details of desert ground water systems. The study of such systems is relevant to understanding solute acquisition, transport, and fractionation processes that are active in the subsurface. Observations of playa evaporites may also be useful for monitoring the hydrologic response of desert basins to changing climatic conditions on regional and global scales. Ongoing work using Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data to map evaporite minerals in the Death Valley salt pan is described. The AVIRIS data point to differences in inflow water chemistry in different parts of the Death Valley playa system and have led to the discovery of at least two new North American mineral occurrences. Seven segments of AVIRIS data were acquired over Death Valley on 31 July 1990, and were calibrated to reflectance by using the spectrum of a uniform area of alluvium near the salt pan. The calibrated data were subsequently analyzed by using least-squares spectral band-fitting methods, first described by Clark and others. In the band-fitting procedure, AVIRIS spectra are fit compared over selected wavelength intervals to a series of library reference spectra. Output images showing the degree of fit, band depth, and fit times the band depth are generated for each reference spectrum. The reference spectra used in the study included laboratory data for 35 pure evaporite spectra extracted from the AVIRIS image cube. Additional details of the band-fitting technique are provided by Clark and others elsewhere in this volume.

Crowley, J. K.↗

An Improved Weighted Least Squares Algorithm for the Analysis of Strain-Gage Balance Calibration Data

An improved version of an algorithm is presented that uses a weighted least squares fit of balance calibration data for the generation of the balance load prediction equations. The weighted least squares fit assigns a weighting factor between zero and one to each calibration data point that depends on a simple count of the number of intentionally loaded balance gages. The greater the number of the loaded gages is, the smaller a data point's weighting factor becomes. This strategy has two advantages. First, single-component loads become more influential during the regression analysis of the calibration data. In addition, the negative influence of load schedule asymmetries on the regression analysis results can more effectively be controlled. The original algorithm of 2017 was improved in 2020. Now, gage output differences relative to the natural zeros are exclusively used as input for the determination of the number of intentionally loaded gages. The improved weighted least squares fit can be applied with both the Non-Iterative Method and the Iterative Method that are used for the balance load prediction in the aerospace testing community. Machine calibration data of a force balance is used to illustrate benefits of the application of the improved weighted least squares fit of balance calibration data.

strain-gage balance↗

A highly accurate method for the determination of mass and center of mass of a spacecraft

An extremely accurate method for the measurement of mass and the lateral center of mass of a spacecraft has been developed. The method was needed for the Voyager spacecraft mission requirement which limited the uncertainty in the knowledge of lateral center of mass of the spacecraft system weighing 750 kg to be less than 1.0 mm (0.04 in.). The method consists of using three load cells symmetrically located at 120 deg apart on a turntable with respect to the vertical axis of the spacecraft and making six measurements for each load cell. These six measurements are taken by cyclic rotations of the load cell turntable and of the spacecraft, about the vertical axis of the measurement fixture. This method eliminates all alignment, leveling, and load cell calibration errors for the lateral center of mass determination, and permits a statistical best fit of the measurement data. An associated data reduction computer program called MASCM has been written to implement this method and has been used for the Voyager spacecraft.

Chow, E. Y.↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing mineralogy, carbon composition/speciation, and crystal orientation all within a petrographic context. Adequately examining the heterogeneous composition of a meteorite, while maintaining low laser powers needed to prevent damage to meteorite mineralogy and organics, often requires the collection of large Raman images with long collection times on the timescale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. This decrease in frequency precision can compromise the analysis of geological markers that can provide important information on a meteorite sample. We examine, in detail, the change in bandwidth and frequency of the Raman bands and Hg-Ar emission lines in our Raman images as a function of time and laboratory temperature. To overcome the drift in calibration, we utilize a commercial WITec Raman instrument with an internal Hg-Ar calibration lamp to individually calibrate each spectrum in the Raman image. Our instrument, known as “Ratatoskr”, uses a beam splitter in place of the customary mirror to facilitate collection of Hg-Ar calibration lines concurrent with Raman spectra. We show that using the internal calibration we can improve the frequency precision for the spectra in our Raman images from ~±0.15 cm(exp -1) to ~±0.05 cm(exp -1) for Raman spectra collected over multiple days. This is important as it improves measurements of mineral chemistry, latent strain, and other features that are dependent upon accurate peak position determination. We also examine the spectral signal-to-noise ratio needed to minimize the frequency error when fitting bands to Gaussian/Lorentzian profiles. We then use our results to suggest a general method for calibrating the frequency of Raman spectra in large Raman images.

Jakubek, Ryan S.↗

Dark Energy Survey: Galaxy sample for the baryonic acoustic oscillation measurement from the final dataset

In this paper, we present and validate the galaxy sample used for the analysis of the baryon acoustic oscillation (BAO) signal in the Dark Energy Survey (DES) Y6 data. The definition is based on a color and redshift-dependent magnitude cut optimized to select galaxies at redshifts higher than 0.6, while ensuring a high-quality photo- z determination. The optimization is performed using a Fisher forecast algorithm, finding the optimal i -magnitude cut to be given by i < 19.64 + 2.894 z ph . For the optimal sample, we forecast an increase in precision in the BAO measurement of ∼ 25 % with respect to the Y3 analysis. Our BAO sample has a total of 15,937,556 galaxies in the redshift range 0.6 < z ph < 1.2 , and its angular mask covers 4 , 273.42 deg 2 to a depth of i = 22.5 . We validate its redshift distributions with three different methods: directional neighborhood fitting algorithm (DNF), which is our primary photo- z estimation; direct calibration with spectroscopic redshifts from VIPERS, which is a spectroscopic galaxy sample that overlaps with our BAO sample and is complete within our selection cuts; and clustering redshift using SDSS galaxies. The fiducial redshift distribution is a combination of these three techniques performed by modifying the mean and width of the DNF distributions to match those of VIPERS and clustering redshift. In this paper, we also describe the methodology used to mitigate the effect of observational systematics, which is analogous to the one used in the Y3 analysis. This paper is one of the two dedicated to the analysis of the BAO signal in DES Y6. In its companion paper, we present the angular diameter distance constraints obtained through the fitting to the BAO scale.

79 ASTRONOMY AND ASTROPHYSICS↗

Photographic photometry with Iris diaphragm photometers

A general method is presented for solving problems encountered in the analysis of Iris diaphragm photometer (IDP) data. The method is used to derive the general shape of the calibration curve, allowing both a more accurate fit to the IDP data for comparison stars and extrapolation to magnitude ranges for which no comparison stars are measured. The profile of starlight incident and the characteristic curve of the plate are both assumed and then used to derive the profile of the star image. An IDP reading is then determined for each star image. A procedure for correcting the effects of a nonconstant background fog level on the plate is also demonstrated. Additional applications of the method are made in the appendix to determine the relation between the radius of a photographic star image and the star's magnitude, and to predict the IDP reading of the 'point of optimum density'.

Schaefer, B. E.↗

Effects of edge-rounding on geodesic lenses

A method that eliminates the need for a mathematical model is described for measuring the absolute light intensity radiated from volume chemiluminescent and fluorescent sources. This technique applies to a uniform cylindrical luminous volume, which is the geometry most often practical for the study of flowing chemiluminescent and fluorescent fluids. In this method, the necessary integration over a luminous volume is carried out experimentally, using a calibrated piston source that has as its head a disk of uniform luminosity. The relatively small total error in absolute light intensity measurements with the piston source technique represents a significant improvement over competing comparison methods. The construction of a piston source to fit the cross section of a particular cylindrical volume is straightforward, and its calibration against a standard source can be readily made while exercising normal precautions.

Wood, V. E.↗

Metafitting: Weight optimization for least-squares fitting of PTTI data

For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

Douglas, Rob J.↗

Cosmological constraints from the Planck cluster catalogue with DES shear profiles and Chandra observations

We present cosmological constraints from the Planck PSZ2 cosmological cluster sample, using weak-lensing shear profiles from Dark Energy Survey (DES) data and X-ray observations from the Chandra telescope for the mass calibration. We compute hydrostatic mass estimates for all clusters in the PSZ2 sample with a scaling relation between their Sunyaev-Zeldovich signal and X-ray derived hydrostatic mass, calibrated with the Chandra data. We introduce a method to correct these masses with a hydrostatic mass bias using shear profiles from wide-field galaxy surveys. We simultaneously fit the number counts of the PSZ2 sample and the mass calibration with the DES data, finding $Ω_\text{m}=0.312^{+0.018}_{-0.024}$, $σ_8=0.777\pm 0.024$, $S_8\equiv σ_8 \sqrt{Ω_\text{m} / 0.3}=0.791^{+0.023}_{-0.021}$, and $(1-b)=0.844^{+0.055}_{-0.062}$ for our baseline analysis when combined with BAO data. When considering a hydrostatic mass bias evolving with mass, we find $Ω_\text{m}=0.353^{+0.025}_{-0.031}$, $σ_8=0.751\pm 0.023$, and $S_8=0.814^{+0.019}_{-0.020}$. We verify the robustness of our results by exploring a variety of analysis settings, with a particular focus on the definition of the halo centre used for the extraction of shear profiles. We compare our results with a number of other analyses, in particular two recent analyses of cluster samples obtained from SPT and eROSITA data that share the same mass calibration data set. We find that our results are in overall agreement with most late-time probes, in very mild tension with CMB results (1.6$σ$), and in significant tension with results from eROSITA clusters (2.9$σ$). We confirm that our mass calibration is consistent with the eROSITA analysis by comparing masses for clusters present in both Planck and eROSITA samples, eliminating it as a potential cause of tension.

Aymerich, G. [Orsay, IAS; AIM, Saclay] (ORCID:0009↗

Measurements of the spectrum of galactic electrons at very high energies

A counter telescope has been exposed in three balloon flights in 1970 to measure the flux and energy spectrum of cosmic ray electrons between 10 and 1000 GeV. This instrument has been modified by incorporating a large area CsI crystal as well as highly efficient time of flight circuitry, and was flown again twice during 1972. The methods of data analysis are based on extensive accelerator calibrations at SLAC. The resulting electron spectrum fits well to a single power law with an index (gamma) equal to 2.66 over the whole energy region. No obvious steepening can be observed, although statistical uncertainties prohibit definite claims beyond 250 GeV.

Mueller, D.↗

Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes

Segment mirror phasing, a critical step of segment mirror alignment, requires the ability to sense and correct the relative pistons between segments from up to a few hundred microns to a fraction of wavelength in order to bring the mirror system to its full diffraction capability. When sampling the aperture of a telescope, using auto-collimating flats (ACFs) is more economical. The performance of a telescope with a segmented primary mirror strongly depends on how well those primary mirror segments can be phased. One such process to phase primary mirror segments in the axial piston direction is dispersed fringe sensing (DFS). DFS technology can be used to co-phase the ACFs. DFS is essentially a signal fitting and processing operation. It is an elegant method of coarse phasing segmented mirrors. DFS performance accuracy is dependent upon careful calibration of the system as well as other factors such as internal optical alignment, system wavefront errors, and detector quality. Novel improvements to the algorithm have led to substantial enhancements in DFS performance. The Advanced Dispersed Fringe Sensing (ADFS) Algorithm is designed to reduce the sensitivity to calibration errors by determining the optimal fringe extraction line. Applying an angular extraction line dithering procedure and combining this dithering process with an error function while minimizing the phase term of the fitted signal, defines in essence the ADFS algorithm.

Spechler, Joshua A.↗

Advancements in Constitutive Model Calibration: Leveraging the Power of Full‐Field DIC Measurements and In Situ Load Path Selection for Reliable Parameter Inference

Accurate material characterization and model calibration are essential for computationally supported high-consequence engineering decisions. Historically, characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data are collected for a specific model of interest, (3) use deterministic methods that provide best-fit parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work brings together several recent advancements into an improved workflow called interlaced characterization and calibration (ICC) that advances the state-of-the-art in constitutive model calibration. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) quantifies parameter uncertainty through Bayesian inference and (4) incorporates these advancements into a quasi real-time feedback loop. The ICC framework is demonstrated here on the calibration of a material model using simulated full-field data for an aluminium cruciform specimen being deformed biaxially. The cruciform is actively driven through the myopically preferred load path using Bayesian optimal experimental design, which selects load steps that yield the maximum expected information gain (EIG). Principal component analysis (PCA) is performed on the model predictions of full-field displacements, and fast surrogate models are built to approximate the input-output relationships of the expensive finite element model. Furthermore, the tools developed and demonstrated here show that high-fidelity constitutive models can be efficiently and reliably calibrated with quantified uncertainty, thus supporting credible decision-making and potentially increasing the agility of solid mechanics modelling by enabling utilization of computational simulations at earlier stages of the design cycle.

Bayesian optimal experimental design↗

Enhanced reduction of velocity data obtained during CETA flight experiment

A newly developed technique for enhanced data reduction provides an improved procedure that allows least squares minimization to become possible between data sets with an unequal number of data points. This technique was applied in the Crew and Equipment Translation Aid (CETA) experiment on the STS-37 Shuttle flight in April 1991 to obtain the velocity profile from the acceleration data. The new technique uses a least-squares method to estimate the initial conditions and calibration constants. These initial conditions are estimated by least-squares fitting the displacements indicated by the Hall-effect sensor data to the corresponding displacements obtained from integrating the acceleration data. The velocity and displacement profiles can then be recalculated from the corresponding acceleration data using the estimated parameters. This technique, which enables instantaneous velocities to be obtained from the test data instead of only average velocities at varying discrete times, offers more detailed velocity information, particularly during periods of large acceleration or deceleration.

Finley, Tom D.↗