Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of 83m Kr prompt scintillation signals in the PIXeY detector

Prompt scintillation signals from 83m Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because 83m Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (Δ t), notably its increase at low Δ t. Finally, in PIXeY data, the Δ t dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of 0.05 ± 0.02 μ s, which can be attributed to processing effects and pulse overlap and one with a time constant of 10.2 ± 2.2 μs that increases in amplitude with electric drift field, the origin of which is not yet understood.

47 OTHER INSTRUMENTATION↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Calibrating the DUNE LArTPC detectors for precision physics

The Deep Underground Neutrino Experiment (DUNE) is an international collaboration focused on studying neutrino oscillation over a long baseline (1300 km). DUNE will make use of a near detector and $\mathcal{O}$(GeV) neutrino beam originating at Fermilab in Batavia, IL, and a far detector operating 1.5 km underground at the Sanford Underground Research Facility in Lead, South Dakota. The near and far detectors will use the LArTPC (Liquid Argon Time Projection Chamber) technology to image neutrino interactions. In order to make precise physics measurements at DUNE, such as the amount of CP violation in the neutrino sector, it is essential to be able to accurately reconstruct particle energies and other kinematic quantities; this in turn necessitates an extensive calibration program for DUNE s LArTPC detectors. In this presentation, we describe the requirements for calibrating the DUNE detectors, emphasizing the challenges of massive multi-kiloton LArTPC detectors which are to operate for multiple years deep underground. A preliminary DUNE detector calibration program, including use of both dedicated calibration hardware and cosmogenic/beam-induced calibration sources, is presented. First results on detector calibration at the ProtoDUNE-SP prototype detector located at CERN, and associated impact on calibrations at the DUNE far detector, are also emphasized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Best Practices in PEC Water Splitting: How to Reliably Measure Solar-to-Hydrogen Efficiency of Photoelectrodes

Photoelectrochemical (PEC) water splitting, which utilizes sunlight and water to produce hydrogen fuel, is potentially one of the most sustainable routes to clean energy. One challenge to success is that, to date, similar materials and devices measured in different labs or by different operators lead to quantitatively different results, due to the lack of accepted standard operating procedures and established protocols for PEC efficiency testing. With the aim of disseminating good practices within the PEC community, we provide a vetted protocol that describes how to prepare integrated components and accurately measure their solar-to-hydrogen (STH) efficiency (η STH ). This protocol provides details on electrode fabrication, η STH test device assembly, light source calibration, hydrogen evolution measurement, and initial material qualification by photocurrent measurements under monochromatic and broadband illumination. Common pitfalls in translating experimental results from any lab to an accurate STH efficiency under an AM1.5G reference spectrum are discussed. A III–V tandem photocathode is used to exemplify the process, though with small modifications, the protocol can be applied to photoanodes as well. Dissemination of PEC best practices will help those approaching the field and provide guidance for comparing the results obtained at different lab sites by different groups.

08 HYDROGEN↗

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background↗

Design of an electron cyclotron emission diagnostics suite for COMPASS Upgrade tokamak

COMPASS Upgrade is a medium size and high field tokamak that is capable of addressing key challenges for reactor grade tokamaks, including power exhaust and advanced confinement scenarios. Electron cyclotron emission will be available among the first diagnostics to provide measurements of high spatial and temporal resolution of electron temperature profiles and electron temperature fluctuation profiles through a radial view. A separate oblique view at 12° from normal will be utilized to study non-thermal electrons. Both the radial and oblique views are envisioned to be located in a wide-angle midplane port, which has dimensions that enable simultaneous hosting of the front-end of their quasi-optical (QO) designs. Each QO design will have an in situ hot calibration source in the front-end to provide standalone and calibrated Te (R,t) measurements. The conceptual design for each QO system, the Gaussian beam analysis, and the details of the diagnostic channels are presented.

Instruments & Instrumentation↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test GammaPix™ Radiation Detection Software with Smartphones

GammaPix™ is a smartphone application that uses smartphone cameras to detect ionizing radiation. Brookhaven National Laboratory (BNL) evaluated the performance of the software in detecting radioactive materials. For this purpose, a series of tests were conducted at the Radiation Calibration Facility Annex at BNL. The experiments included dose measurements with three types of NIST-traceable calibration sources, 60Co, 241Am, and 137Cs. The recorded results by GammaPix™ were compared with the values measured by calibrated dosimeters to determine the detection thresholds. Several selected models of iPhones and Android cell phones with different pixel sizes and resolution were tested. In this paper, we present the test procedures and discuss the test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium neutrino absorption cross section and its uncertainty

In the recent Baksan Experiment on Sterile Transitions (BEST), a suppressed rate of neutrino absorption on a gallium target was observed, consistent with earlier results from neutrino source calibrations of the SAGE and GALLEX/GNO solar neutrino experiments. The BEST Collaboration, utilizing a 3.4 MCi 51 Cr neutrino source, found observed-to-expected counting rates at two very short baselines of 𝑅 = 0.791 ± 0.05 and 0.766 ± 0.05, respectively. Among recent neutrino experiments, BEST is notable for the simplicity of both its neutrino spectrum, line neutrinos from an electron-capture source whose intensity can be measured to a estimated precision of 0.23%, and its absorption cross section, where the precisely known rate of electron capture to the gallium ground state, 71 Ge ⁢(𝑒−, 𝜈 𝑒 )⁢ 71 Ga ⁢(g.s.), establishes a minimum value. However, the absorption cross section uncertainty is a common systematic in the BEST, SAGE, and GALLEX/GNO neutrino source experiments. Here, in this work, we update that cross section, considering a variety of electroweak corrections and the role of transitions to excited states, to establish both a central value and reasonable uncertainty, thereby enabling a more accurate assessment of the statistical significance of the gallium anomalies. Results are given for 51 Cr and 37 Ar sources. The revised neutrino capture rates are used in a reevaluation of the BEST and gallium anomalies.

electroweak interactions in nuclear physics↗

Operation modes of the KATRIN experiment Tritium Loop System using 83m Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83m Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83m Kr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83m Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83m Kr-rates, gas densities, and gas compositions inside the WGTS.

47 OTHER INSTRUMENTATION↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

A composite likelihood approach for inference under photometric redshift uncertainty

ABSTRACT Obtaining accurately calibrated redshift distributions of photometric samples is one of the great challenges in photometric surveys like LSST, Euclid, HSC, KiDS, and DES. We present an inference methodology that combines the redshift information from the galaxy photometry with constraints from two-point functions, utilizing cross-correlations with spatially overlapping spectroscopic samples, and illustrate the approach on CosmoDC2 simulations. Our likelihood framework is designed to integrate directly into a typical large-scale structure and weak lensing analysis based on two-point functions. We discuss efficient and accurate inference techniques that allow us to scale the method to the large samples of galaxies to be expected in LSST. We consider statistical challenges like the parametrization of redshift systematics, discuss and evaluate techniques to regularize the sample redshift distributions, and investigate techniques that can help to detect and calibrate sources of systematic error using posterior predictive checks. We evaluate and forecast photometric redshift performance using data from the CosmoDC2 simulations, within which we mimic a DESI-like spectroscopic calibration sample for cross-correlations. Using a combination of spatial cross-correlations and photometry, we show that we can provide calibration of the mean of the sample redshift distribution to an accuracy of at least 0.002(1 + z), consistent with the LSST-Y1 science requirements for weak lensing and large-scale structure probes.

(cosmology:) large-scale structure of Universe↗

Demonstration of neutron radiation-induced nucleation of supercooled water

In this study, we present direct evidence for neutrons causing nucleation of supercooled water. Highly purified water (20 nm filtration) is cooled to well below freezing (as low as −20 °C) with a radioactive calibration source of neutrons/gamma-rays either present or removed during each of many control cooling runs for the same volume of water. When it is primarily neutrons irradiating the sample bulk, the non-equilibrium freezing point (also known as the “supercooling point”) is, on average, +0.7 °C warmer than the control equivalent, with a statistical significance of greater than 5 Sigma, with systematic uncertainty included. This effect is not observed with water in the presence of gamma-rays instead of neutrons. While these neutrons should have theoretically had sufficient energy to mount the energy barrier, corroborating our results, their raising of supercooling temperature has never been reported experimentally to the best of our knowledge. The potential to use deeply supercooled solutions, not only water, as metastable detectors for radiation and perhaps dark matter or neutrino physics presents now a new avenue for exploration.

Szydagis, Matthew↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

Cryogenic Detector Development for SuperCDMS

The dark matter (DM) problem is currently one of the most pressing issues facing physics. This thesis presents some of my work and contributions to the detectors employed by the Super Cryogenic Dark Matter Search (SuperCDMS), one of the many experiments currently investigating DM. First, we present an overview of astrophysical and cosmological observations to give insight into our current understanding of DM and its role in the universe. Some potential particle DM candidates are also discussed. Then we describe the SuperCDMS experiment and relevant detector technologies. We go into particular detail in discussing the phonon sensors, deriving the relationships that define their fundamental working principles and describing their practical deployment. We also discuss the main noise contributions to the phonon sensors which can limit experimental sensitivity. We then present some work related to reconstruction of event position in the detectors, including new analysis techniques and a n ovel cryogenic calibration source mover we have developed and tested. We also present tests of improving experimental scalability by increasing individual detector masses using the largest-diameter cryogenic Si detectors yet operated. We present first experimental results from the novel use of $(n,\gamma)$ processes to calibrate the low energy nuclear recoil energy scale. This work is essential to understand how DM-nuclear interactions will manifest in semiconductor detectors. We also take a short look at the newest, most sensitive detectors currently operated by SuperCDMS and discuss how they are allowing new insights into critical physics processes in all SuperCDMS detectors. Finally, we demonstrate how some of the various improvements discussed in this work can improve the experimental reach of the next generation of SuperCDMS at SNOLAB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Primary Beam of the Tianlai Cylindrical Antenna Using an Unmanned Aerial Vehicle

The Tianlai Cylinder Pathfinder Array consists of three adjacent cylindrical reflectors fixed on the ground, each 40 m long and 15 m wide, with the cylinder axis oriented along the North–South (N–S) direction. Dual linear polarization feeds are distributed along the focus line, parallel to the cylinder axis. Measurement of the primary beam profile of these cylindrical reflectors is difficult, as they are too large to be placed in an anechoic chamber. While the beam profile along the East–West (E–W) direction can be measured with the transit observations of bright astronomical radio sources, the beam profile along the N–S direction remains very uncertain. Here, we present a preliminary measurement of the beam profile of the Tianlai cylindrical antenna along both the N–S direction and E–W direction in the frequency range of 700–800 MHz, using a calibrator source carried by an unmanned aerial vehicle (UAV) flying in the far field. The beam profile of the Tianlai cylindrical antenna is determined from the analysis of the auto-correlation signals from the cylinder array correlator, taking into account the emitter antenna beam profile, itself measured with a dipole antenna on the ground. The accuracy of the UAV-based determination of the cylinder beam profiles is validated by comparing the results with the one derived from bright astronomical source transits, and with simulated beams.

Li, Jixia [Chinese Academy of Sciences (CAS), Beij↗

Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ~2.5 cm (FWHM) and an effective time resolution of ~1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. In conclusion, the upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗