At least 37 records · Page 2

Trielectrode capacitive pressure transducer

A capacitive transducer and circuit especially suited for making measurements in a high-temperature environment are described. The transducer includes two capacitive electrodes and a shield electrode. As the temperature of the transducer rises, the resistance of the insulation between the capacitive electrode decreases and a resistive current attempts to interfere with the capacitive current between the capacitive electrodes. The shield electrode and the circuit coupled there reduce the resistive current in the transducer. A bridge-type circuit coupled to the transducer ignores the resistive current and measures only the capacitive current flowing between the capacitive electrodes.

Coon, G. W.↗

A system for measuring thermal activation energy levels in silicon by thermally stimulated capacitance

One method being used to determine energy level(s) and electrical activity of impurities in silicon is described. The method is called capacitance transient spectroscopy (CTS). It can be classified into three basic categories: the thermally stimulated capacitance method, the voltage-stimulated capacitance method, and the light-stimulated capacitance method; the first two categories are discussed. From the total change in capacitance and the time constant of the capacitance response, emission rates, energy levels, and trap concentrations can be determined. A major advantage of using CTS is its ability to detect the presence of electrically active impurities that are invisible to other techniques, such as Zeeman effect atomic absorption, and the ability to detect more than one electrically active impurity in a sample. Examples of detection of majority and minority carrier traps from gold donor and acceptor centers in silicon using the capacitance transient spectrometer are given to illustrate the method and its sensitivity.

Cockrum, R. H.↗

Influence of Charge Transport Layers on Capacitance Measured in Halide Perovskite Solar Cells

Capacitance-based techniques were previously used to measure the electrical properties of halide perovskite solar cells (PSCs) such as defect activation energy and density, carrier concentration, and dielectric constant, which provide key information for evaluating the device performance. Herein, we show that capacitance-based techniques cannot be used to reliably analyze the properties of defects in the perovskite layer or at its interface, since the high-frequency capacitance signature is due to the response of charge carriers in the hole-transport layer (HTL). For HTL-free PSCs, the high-frequency capacitance can be considered as the geometric capacitance for analyzing the dielectric constant of the perovskite layer, since there is no trapping and de-trapping of charge carriers in the perovskite layer. We also find that the low-frequency capacitance signature can be used to calculate the activation energy of the ionic conductivity of the perovskite layer, but the overlapping effects with charge transport materials must be avoided.

14 SOLAR ENERGY↗

Novel High Temperature Capacitive Pressure Sensor Utilizing SiC Integrated Circuit Twin Ring Oscillators

This paper describes initial development and testing of a novel high temperature capacitive pressure sensor system. The pressure sensor system consists of two 4H-SiC 11-stage ring oscillators and a SiCN capacitive pressure sensor. One oscillator has the capacitive pressure sensor fixed at one node in its feedback loop and varies as a function of pressure and temperature while the other provides a pressure-independent reference frequency which can be used to temperature compensate the output of the first oscillator. A two-day repeatability test was performed up to 500C on the oscillators and the oscillator fundamental frequency changed by only 1. The SiCN capacitive pressure sensor was characterized at room temperature from 0 to 300 psi. The sensor had an initial capacitance of 3.76 pF at 0 psi and 1.75 pF at 300 psi corresponding to a 54 change in capacitance. The integrated pressure sensor system was characterized from 0 to 300 psi in steps of 50 psi over a temperature range of 25 to 500C. The pressure sensor system sensitivity was 0.113 kHzpsi at 25C and 0.026 kHzpsi at 500C.

high temperature↗

Effects of interlayer confinement and hydration on capacitive charge storage in birnessite

Nanostructured birnessite exhibits high specific capacitance and nearly ideal capacitive behaviour in aqueous electrolytes, rendering it an important electrode material for low-cost, high-power energy storage devices. The mechanism of electrochemical capacitance in birnessite has been described as both Faradaic (involving redox) and non-Faradaic (involving only electrostatic interactions). To clarify the capacitive mechanism, we characterized birnessite’s response to applied potential using ex situ X-ray diffraction, electrochemical quartz crystal microbalance, in situ Raman spectroscopy and operando atomic force microscope dilatometry to provide a holistic understanding of its structural, gravimetric and mechanical responses. These observations are supported by atomic-scale simulations using density functional theory for the cation-intercalated structure of birnessite, ReaxFF reactive force field-based molecular dynamics and ReaxFF-based grand canonical Monte Carlo simulations on the dynamics at the birnessite–water–electrolyte interface. We show that capacitive charge storage in birnessite is governed by interlayer cation intercalation. We conclude that the intercalation appears capacitive due to the presence of nanoconfined interlayer structural water, which mediates the interaction between the intercalated cation and the birnessite host and leads to minimal structural changes.

36 MATERIALS SCIENCE↗

A Probabilistic Mass Estimation Algorithm for a Novel 7- Channel Capacitive Sample Verification Sensor

A document describes an algorithm created to estimate the mass placed on a sample verification sensor (SVS) designed for lunar or planetary robotic sample return missions. A novel SVS measures the capacitance between a rigid bottom plate and an elastic top membrane in seven locations. As additional sample material (soil and/or small rocks) is placed on the top membrane, the deformation of the membrane increases the capacitance. The mass estimation algorithm addresses both the calibration of each SVS channel, and also addresses how to combine the capacitances read from each of the seven channels into a single mass estimate. The probabilistic approach combines the channels according to the variance observed during the training phase, and provides not only the mass estimate, but also a value for the certainty of the estimate. SVS capacitance data is collected for known masses under a wide variety of possible loading scenarios, though in all cases, the distribution of sample within the canister is expected to be approximately uniform. A capacitance-vs-mass curve is fitted to this data, and is subsequently used to determine the mass estimate for the single channel s capacitance reading during the measurement phase. This results in seven different mass estimates, one for each SVS channel. Moreover, the variance of the calibration data is used to place a Gaussian probability distribution function (pdf) around this mass estimate. To blend these seven estimates, the seven pdfs are combined into a single Gaussian distribution function, providing the final mean and variance of the estimate. This blending technique essentially takes the final estimate as an average of the estimates of the seven channels, weighted by the inverse of the channel s variance.

Wolf, Michael↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

14 SOLAR ENERGY↗

Observability of negative capacitance of a ferroelectric film: Theoretical predictions

Here, we theoretically explore mechanisms that can potentially give rise to the steady-state and transient negative capacitance in a uniaxial ferroelectric film stabilized by a dielectric layer. The analytical expressions for the steady-state capacitance of a single-domain and polydomain states are derived within the Landau-Ginzburg-Devonshire approach and used to study the state stability vs the domain splitting as a function of dielectric layer thickness. Analytical expressions for the critical thickness of the dielectric layer, polarization amplitude, equilibrium domain period, and susceptibility are obtained and corroborated by finite element modeling. Furthermore we explore the possible effects of nonlinear screening by two types of screening charges at the ferroelectric-dielectric interface and show that if at least one of the screening charges is very slow, the total polarization dynamics can exhibit complex time- and voltage-dependent behaviors that can be interpreted as an observable negative capacitance. In this setting, the transient negative capacitance effect is accompanied by almost zero dielectric susceptibility in a wide voltage range and low frequencies. These results may help to elucidate the observation of the transient negative capacitance in thin ferroelectric films, and identify materials systems that can give rise to the behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stray-Capacitance As a Simple Tool for Monitoring and Locating Heat Generation Demonstrated in Three Superconducting Magnets

Real-time monitoring of heat loads in cryogenic systems is critical for many applications, particularly high field magnets. In this work, we demonstrated that by monitoring changes in the capacitance of local probes consisting of thin metal strips with a porous glass fiber dielectric, boiling helium from as little as 0.1 J of deposited heat can be located by an analysis of the response speed and amplitude in nearby probes. We further implemented stray-capacitance monitoring of a magnet's metal support structures, a more global probe of the magnet volumes, in three high temperature superconducting Bi-2212 magnet types. Global structural stray-capacitance monitoring was evaluated for a single racetrack coil, a common coil dipole, and a canted cosine theta winding, showing a quench response comparable to voltage signals without inductive effects. The response of the local and global probes was compared in the single racetrack coil with well-known quench properties. Monitoring the cool-down of the common coil dipole demonstrated the added benefit of the global stray-capacitance as a liquid level monitor. This simple method of monitoring the capacitance has proven to be a versatile and robust technique for monitoring and locating heat.

43 PARTICLE ACCELERATORS↗

Active Reduction of Apparent Cable Capacitance

This paper presents a method for reducing apparent cable capacitance seen by sensors. The proposed method is designed for sensing in extreme environments including ultra-high temperatures, but can be applied in benign environments as well. By reducing the cable capacitance, high speed signals can be transmitted over longer distances, allowing the application of advanced control systems that require high bandwidth data for stable operation. A triaxial cable with an associated guard circuit is developed that actively reduces cable capacitance while also rejecting extraneous electric and magnetic interference on the signal. The active capacitance reduction method developed is tested experimentally and shown to reduce apparent cable capacitance to two percent of the static value.

47 OTHER INSTRUMENTATION↗

Capacitance of Carbon Nanotube/Graphene Composite Electrodes with [BMIM + ][BF$_4^–$]/Acetonitrile: Fixed Voltage Molecular Dynamics Simulations

The capacitance of nanoporous carbon electrode materials is dictated by the physical interactions with electrolyte ions and molecules at the accessible interior electrode surface. While significant progress has been made in designing and synthesizing carbon materials with well-defined and relatively homogeneous nanoporosity, the majority of materials remain heterogeneous, and the resulting properties reflect an average over this distribution. In this regard, computer simulations can be a valuable tool to predict or validate structure/property relationships by systematically investigating well-defined, model electrode morphologies. In this work, we utilize fixed-voltage molecular dynamics simulations to predict structure/capacitance relationships for five different model morphologies of carbon nanotube/graphene (CNT/G) composite electrodes with 1-butyl-3-methylimidazolium tetrafluoroborate/acetonitrile electrolyte. The CNT/G electrode models are inspired by experimental “layer-by-layer” syntheses and strike a balance between realism and computational tractability. Comparison between different model electrode architectures elucidates important structure/property relationships. We find that CNT/graphene contact points serve as “hot spots” with significantly enhanced charge separation relative to the rest of the electrode. Furthermore, we demonstrate a specific nanoconfinement motif that provides substantial 3–4$\times$ enhancement of local capacitance, resulting in a ~40% increase of the total electrode differential capacitance. Because the accessible surface area of the model CNT/G electrodes is precisely determined, a comparison of per-area capacitance across systems is unambiguous. Our results thus complement a prior computational demonstration of capacitance enhancement in nanoconfinement while elucidating additional interaction motifs at CNT/G electrochemical interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Negative capacitance regime in antiferroelectric PbZrO 3

The potential of antiferroelectrics to exhibit a negative capacitance regime has been largely overlooked as all the attention focused on their polar counterparts, ferroelectrics. We use nonequilibrium first-principles-based molecular dynamics to probe a negative capacitance regime in prototypical antiferroelectric PbZrO 3 . Simulations predict that this antiferroelectric can exhibit a negative capacitance/susceptibility regime in response of polarization to an internal electric field, which is a superposition of applied and residual depolarizing fields. Consequently, the regime emerges when the polarization surface charge in the polar phase of antiferroelectric is not fully screened, as is often the case in thin films and nanostructures. The negative capacitance regime occurs below the Curie temperature and disappears in the paraelectric phase. We find that the time the material spends in the negative capacitance regime is proportional to the time needed to complete antipolar–polar (or its reverse) transition and shortens as the frequency of the applied field increases. Furthermore, a negative susceptibility value exhibits strong dependence on the quality of surface charge screening with the largest in magnitude values occurring in the vicinity of the transition into a negative capacitance regime.

36 MATERIALS SCIENCE↗

Development of a capacitance measurement for pulsed magnetic fields

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an auto-balancing bridge method, leveraging a high-bandwidth transimpedance amplifier to mitigate parasitic contributions from coaxial cables. This technique enables precise capacitance measurements in rapidly changing magnetic fields, as demonstrated in experiments on the magnetoelectric material NiCo 2 TeO 6 . The results reveal strong magnetoelectric coupling, including a pronounced hysteresis in capacitance that coincides with magnetization measurements and an enhanced energy dissipation peak at high sweep rates. Compared to traditional LCR meter measurements in DC fields, our method exhibits excellent agreement while providing additional insight into field-induced phase transitions. This work establishes a robust methodology for capacitance measurements under extreme conditions and opens new opportunities for studying multiferroic and correlated electron systems under high magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Capacitance-type blade-tip clearance measurement system using a dual amplifier with ramp/dc inputs and integration

The analysis and prototype results of a dual-amplifier circuit for measuring blade-tip clearance in turbine engines are presented. The capacitance between the blade tip and mounted capacitance electrode within a guard ring of a probe forms one of the feedback elements of an operational amplifier (op amp). The differential equation governing the circuit taking into consideration the nonideal features of the op amp was formulated and solved for two types of inputs (ramp and dc) that are of interest for the application. Under certain time-dependent constraints, it is shown that (1) with a ramp input the circuit has an output voltage proportional to the static tip clearance capacitance, and (2) with a dc input, the output is proportional to the derivative of the clearance capacitance, and subsequent integration recovers the dynamic capacitance. The technique accommodates long cable lengths and environmentally induced changes in cable and probe parameters. System implementation for both static and dynamic measurements having the same high sensitivity is also presented.

Sarma, Garimella R.↗

Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends were surrounded by a metal guard to reduce the sensitivity of the electrodes to outside interference and to help maintain the spacing between the arrays. Other uses for this innovation potentially include quantifying the amount of commodity remaining in the fuel and oxidizer tanks while on-orbit without having to fire spacecraft engines. Another orbit application is moisture sensing in plant-growth experiments because microgravity causes moisture in soil to distribute itself in unusual ways. At the moment, the hardware and image reconstruction technique may only be of interest to people involved in nondestructive evaluation. The reconstructed image takes almost a full week to reproduce with existing computer power. However, because computer power and speeds follows Moore s Law, execution times are likely to become acceptable within the next five to eight years. The code was written in Mathematica for dedicated use with the ECVT system. In its present form, it is not suitable to be used directly as a consumer product. However, the code could be likely improved by rewriting it in a compiled language such as C or Fortran.

Nurge, Mark↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗

Size Effect of Negative Capacitance State and Subthreshold Swing in Van der Waals Ferrielectric Field–Effect Transistors

Analytical calculations corroborated by the finite element modeling show that thin films of Van der Waals ferrielectrics covered by a 2D-semiconductor are promising candidates for the controllable reduction of the dielectric layer capacitance due to the negative capacitance (NC) effect emerging in the thin films. The NC state is conditioned by energy-degenerated poly-domain states of the ferrielectric polarization induced in the films under incomplete screening conditions in the presence of a dielectric layer. Calculations performed for the FET-type heterostructure “ferrielectric CuInP 2 S 6 film—2D-MoS 2 single-layer—SiO 2 dielectric layer” reveal the pronounced size effect of the multilayer capacitance. Derived analytical expressions for the electric polarization and multilayer capacitance allow to predict the thickness range of the dielectric layer and ferrielectric film for which the NC effect is the most pronounced in various Van der Waals ferrielectrics, and the corresponding subthreshold swing becomes much less than the Boltzmann's limit. Obtained results can be useful for the size and temperature control of the NC effect in the steep-slope ferrielectric FETs.

36 MATERIALS SCIENCE↗

Dissolved CO 2 Modulates the Electrochemical Capacitance on Gold Electrodes

The presence of CO 2 at an electrified interface between an aqueous electrolyte and a metal electrode is the prerequisite for many electrochemical CO 2 capture technologies. To understand the behavior of dissolved CO 2 at an aqueous electrified interface, we characterized the electrochemical interface of planar gold electrodes with cyclic voltammetry, electrochemical impedance spectroscopy (EIS), electrochemical surface plasmon resonance (EC–SPR), and attenuated total reflectance surface-enhanced infrared spectroscopy (ATR–SEIRAS). Under all investigated conditions, we observed a decrease in the electrochemical capacitance upon saturation of the electrolyte with CO 2 , as compared to an electrolyte saturated with Ar. EIS and EC–SPR showed that this capacitance reduction was also potential dependent: it reached a minimum near the point of zero charge and became more significant as the applied potential moved further away from the point of zero charge. Hybrid quantum–classical simulations of the gold/aqueous electrolyte interface indicate that bicarbonate decreases the capacitance and modifies the composition of the electric double layer. In addition to the binding of bicarbonate under positive bias, we propose that molecular CO 2 can be induced by applied potential to concentrate in the diffuse layer of the electric double layer, leading to a reduction in the electrochemical capacitance under both negative and positive bias. Furthermore, this work advances the understanding of non-Faradaic effects of dissolved CO 2 at aqueous electrified interfaces of relevance for electrochemical CO 2 capture.

25 ENERGY STORAGE↗