Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Yield analysis of large capacity magnetic bubble circuits with redundancy design

The fabrication yield of an on-chip modifiable redundant circuit design for a 100M bit serial shift register is evaluated. The yield model is a redundancy design in which there is a primary loop and a set of secondary loops which can be enabled/disabled without introducing blanks to the data stream. This function has a finite yield, the loop-modification yield factor, which must be greater than 0.9 to make the system more economical than the simple nonredundant design. It is further established that small loop capacities greatly degrade the yield because of the effect of the modification yield factor, while large loop capacities degrade the yield because of defects in the operating area. As the modification yield increases the optimum loop capacity decreases. An optimum value for the number of redundant loops exists for each loop capacity. Other factors that affect the yield are the garnet film and the processed circuit.

Bailey, R. F.↗

Self discharge of nickel-hydrogen cells

Values for the capacity loss with time, naturally on open circuit stand, and information regarding the minimum amount of circuit charge needed to keep the cell charged can be determined from the self-discharge behavior of nickel hydrogen cells. Furthermore, the rate of reaction between hydrogen and a charged nickel electrode is also open for nickel cadmium batteries. In a nickel hydrogen cell, the hydrogen is stored as pressurized gas and the cell stack with the charge that is oxidized nickel-hydroxide electrode is in direct contact with the hydrogen. Therefore, the rate of reaction can be measured easily and precisely by monitoring the charge, the change in hydrogen pressure with time. Measures made on twelve 15 ampere hour nickel hydrogen cells of different stack configurations built for COMSAT are discussed.

Holleck, G.↗

Effects of various assumptions on the calculated liquid fraction in isentropic saturated equilibrium expansions

The saturated equilibrium expansion approximation for two phase flow often involves ideal-gas and latent-heat assumptions to simplify the solution procedure. This approach is well documented by Wegener and Mack and works best at low pressures where deviations from ideal-gas behavior are small. A thermodynamic expression for liquid mass fraction that is decoupled from the equations of fluid mechanics is used to compare the effects of the various assumptions on nitrogen-gas saturated equilibrium expansion flow starting at 8.81 atm, 2.99 atm, and 0.45 atm, which are conditions representative of transonic cryogenic wind tunnels. For the highest pressure case, the entire set of ideal-gas and latent-heat assumptions are shown to be in error by 62 percent for the values of heat capacity and latent heat. An approximation of the exact, real-gas expression is also developed using a constant, two phase isentropic expansion coefficient which results in an error of only 2 percent for the high pressure case.

Bursik, J. W.↗

Specific cooling capacity of liquid nitrogen

The assumed cooling process and the method used to calculate the specific cooling capacity of liquid nitrogen are described, and the simple equation fitted to the calculated specific cooling capacity data, together with the graphical form calculated values of the specific cooling capacity of nitrogen for stagnation temperatures from saturation to 350 K and stagnation pressures from 1 to 10 atmospheres, are given.

Kilgore, R. A.↗

Evaluation of the photochemical reflectance index in AVIRIS imagery

In this paper, we evaluate the potential for extracting the 'photochemical reflectance index' (PRI; previously called the 'physiological reflectance index') from AVIRIS data. This index, which is derived from narrow-band reflectance at 531 and 570 nm, has proven to be a useful indicator of photosynthetic function at the leaf and canopy scales. At the leaf level, PRI varies with photosynthetic capacity, radiation-use efficiency, and vegetation type (unpublished data). This finding is consistent with the hypothesis that vegetation types exhibiting chronically reduced photosynthesis during periods of stress (e.g. drought-tolerant evergreens) invest proportionally more in photoprotective processes than vegetation with high photosynthetic capacity (e.g. crops or deciduous perennials). Vertical transects in tropical and boreal forest canopies have indicated declines in PRI associated with downregulation of photosynthesis at the canopy tops under sunny, dry midday conditions (unpublished data). This reduced PRI in upper canopy levels provides a further basis for examining this signal with the 'view from above' afforded by aircraft overflights. Although many factors could confound interpretation of a subtle physiological signal at the landscape scale, we conducted a preliminary examination of PRI extracted from existing, AVIRIS imagery of Stanford University's Jasper Ridge Biological Preserve obtained on the June 2nd, 1992, overflight. The goal was to use the hyperspectral capabilities of AVIRIS to evaluate the potential of this index for obtaining useful physiological data at the landscape scale. The expectation based on leaf- and canopy-level studies was that regions containing vegetation of reduced photosynthetic capacity (e.g. chaparral or evergreen woodland) would exhibit lower PRI values than regions of high capacity (e.g. deciduous woodland).

Gamon, John A.↗

Thermophysical Properties of Cold and Vacuum Plasma Sprayed Cu-Cr-X Alloys, NiAl and NiCrAlY Coatings: Specific Heat Capacity - Part 2

Part I of the paper discussed the temperature dependencies of the electrical resistivities, thermal conductivities, thermal diffusivities and total hemispherical emissivities of several vacuum plasma sprayed (VPS) and cold sprayed copper alloy monolithic coatings, VPS NiAl, VPS NiCrAlY, extruded GRCop-84 and as-cast Cu-17(wt.%)Cr-5%Al. Part II discusses the temperature dependencies of the constant pressure specific heat capacities, CP, of these coatings. The data were empirically were regression-fitted with the equation: CP = AT4 + BT3 + CT2 + DT +E where T is the absolute temperature and A, B, C, D and E are regression constants. The temperature dependencies of the molar enthalpy, molar entropy and Gibbs molar free energy determined from experimental values of molar specific heat capacity are reported. Calculated values of CP using the Neumann-Kopp (NK) rule were in poor agreement with experimental data. Instead, a modification of the Neumann-Kopp rule was found to predict values closer to the experimental data with an absolute deviation less than 6.5%. The specific molar heat capacities for all the alloys did not agree with the Dulong-Petit law, and CP is greater than 3R, where R is the universal gas constant, were measured for all the alloys except NiAl for which CP is less than 3R at all temperatures.

Raj, S. V.↗

Combustor Computations for CO2-Neutral Aviation

Knowing the pure component C(sub p)(sup 0) or mixture C(sub p) (sup 0) as computed by a flexible code such as NIST-STRAPP or McBride-Gordon, one can, within reasonable accuracy, determine the thermophysical properties necessary to predict the combustion characteristics when there are no tabulated or computed data for those fluid mixtures 3or limited results for lower temperatures. (Note: C(sub p) (sup 0) is molar heat capacity at constant pressure.) The method can be used in the determination of synthetic and biological fuels and blends using the NIST code to compute the C(sub p) (sup 0) of the mixture. In this work, the values of the heat capacity were set at zero pressure, which provided the basis for integration to determine the required combustor properties from the injector to the combustor exit plane. The McBride-Gordon code was used to determine the heat capacity at zero pressure over a wide range of temperatures (room to 6,000 K). The selected fluids were Jet-A, 224TMP (octane), and C12. It was found that each heat capacity loci were form-similar. It was then determined that the results [near 400 to 3,000 K] could be represented to within acceptable engineering accuracy with the simplified equation C(sub p) (sup 0) = A/T + B, where A and B are fluid-dependent constants and T is temperature (K).

Hendricks, Robert C.↗

Thermal Property Measurement of Semiconductor Melt using Modified Laser Flash Method

This study further developed standard laser flash method to measure multiple thermal properties of semiconductor melts. The modified method can determine thermal diffusivity, thermal conductivity, and specific heat capacity of the melt simultaneously. The transient heat transfer process in the melt and its quartz container was numerically studied in detail. A fitting procedure based on numerical simulation results and the least root-mean-square error fitting to the experimental data was used to extract the values of specific heat capacity, thermal conductivity and thermal diffusivity. This modified method is a step forward from the standard laser flash method, which is usually used to measure thermal diffusivity of solids. The result for tellurium (Te) at 873 K: specific heat capacity 300.2 Joules per kilogram K, thermal conductivity 3.50 Watts per meter K, thermal diffusivity 2.04 x 10(exp -6) square meters per second, are within the range reported in literature. The uncertainty analysis showed the quantitative effect of sample geometry, transient temperature measured, and the energy of the laser pulse.

Lin, Bochuan↗

The main peculiarities of the processes of the deformation and destruction of lunar soil

The main results of study of the physical and mechanical properties of lunar soil, obtained by laboratory study of samples returned from the moon by Luna 16 and Luna 20, as well as by operation of the self-propelled Lunokhod 1 and Lunokhod 2 on the surface of the moon, are analyzed in the report. All studies were carried out by single methods and by means of unified instruments, allowing a confident comparison of the results obtained. The investigations conducted allowed the following values of the main physical-mechanical properties of lunar soil to be determined: in the natural condition the solid density corresponds to the porosity of 0.8; the modal value of the carrying capacity is 0.4 kg/square cm; adhesion is 0.04 to 0.06 kg/square cm; and the internal angle of friction is 20 to 25 degree. The main mechanisms of deformation and destruction of the soil are analyzed in the report, and the relationships between the mechanical properties and physical parameters of the soil are presented.

Leonovich, A. K.↗

Direct measurements of the Gibbs free energy of OH using a CW tunable laser

The paper describes an absorption measurement for determining the Gibbs free energy of OH generated in a mixture of water and oxygen vapor. These measurements afford a direct verification of the accuracy of thermochemical data of H2O at high temperatures and pressures. The results indicate that values for the heat capacity of H2O obtained through numerical computations are correct within an experimental uncertainty of 0.15 cal/mole K.

Killinger, D. K.↗

Development of AC impedance methods for evaluating corroding metal surfaces and coatings

In an effort to investigate metal surface corrosion and the breakdown of metal protective coatings the AC Impedance Method was applied to zinc chromate primer coated 2219-T87 aluminum. The model 368-1 AC Impedance Measurement System recently acquired by the MSFC Corrosion Research Branch was used to monitor changing properties of coated aluminum disks immersed in 3.5% NaCl buffered at ph 5.5 over three to four weeks. The DC polarization resistance runs were performed on the same samples. The corrosion system can be represented by an electronic analog called an equivalent circuit that consists of transistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for resistances and capacities that can be assigned in the equivalent circuit following a least squares analysis of the data describe changes that occur on the corroding metal surface and in the protective coating. A suitable equivalent circuit was determined that predicts the correct Bode phase and magnitude for the experimental sample. The DC corrosion current density data are related to equivalent circuit element parameters.

Knockemus, Ward↗

Laminar friction and heat transfer at Mach numbers from 1 to 10

Velocity and temperature profiles and laminar boundary-layer characteristics have been computed for Mach numbers from 1 to 10, utilizing experimental values of the heat capacity, viscosity, and conductivity. The analysis shows that effective temperature, which is a function of the surface temperature and stream conditions, arises naturally and is the proper reference temperature to be used in heat-transfer calculations. The effective temperature and the recovery temperature become identical for the condition of zero heat transfer.

Klunker, E B↗

Lunar Surface Material - Spacecraft Measurements of Density and Strength

The relation of the density of the lunar surface layer to depth is probably best determined from spacecraft measurements of the bearing capacity as a function of depth. A comparison of these values with laboratory measurements of the bearing capacity of low-cohesion particulate materials as a function of the percentage of solid indicates that the bulk density at the lunar surface is about 1.1 grams per cubic centimeter and that it increases nearly linearly to about 1.6 grams per cubic centimeter at a depth of 5 centimeters.

Jaffe, L. D.↗

MoO3 Cathodes for High-Temperature Lithium Thin-Film Cells

MoO3 has shown promise as a cathode material that can extend the upper limit of operating temperature of rechargeable lithium thin-film electrochemical cells. Cells of this type are undergoing development for use as energy sources in cellular telephones, wireless medical sensors, and other, similarly sized portable electronic products. The LiCoO2 and LiMn2O4 cathodes heretofore used in these cells exhibit outstanding cycle lives (of the order of hundreds of thousands of cycles) at room temperature, but operation at higher temperatures reduces their cycle lives substantially: for example, at a temperature of 150 C, cells containing LiCoO2 cathodes lose half their capacities in 100 charge/discharge cycles. The superiority of MoO3 as a cathode material was demonstrated in experiments on lithium thin-film cells fabricated on glass slides. Each cell included a layer of Ti (for adhesion to the glass slide), a patterned layer of Pt that served as a cathode current collector, a cathode layer of MoO3, a solid electrolyte layer of Li3.3 PO3.8 N0.22 ("LiPON"), and an anode layer of Li. All the layers were deposited by magnetron sputtering except for the Li layer, which was deposited by thermal evaporation. These cells, along with similar ones containing LiCoO2 cathodes, were subjected to several tests, including measurements of specific capacity in charge/discharge cycling at a temperature of 150 C. The results of these measurements, plotted in the figure, showed that whereas specific capacity of the cells containing LiCoO2 cathodes faded to about half its initial value after only 100 cycles, the specific capacity of the cells containing the MoO3 cathodes faded only slightly during the first few hundred cycles and thereafter not only recovered to its initial value but continued to increase up to at least 5,500 cycles.

West, William↗

Evaluation program for secondary spacecraft cells. Initial evaluation tests of Eagle-Picher Industries, Incorporated 3.0 ampere-hour nickel-cadmium spacecraft cells

The capacity of the cells ranged from 3.58 to 3.97 amperehours during the three capacity tests. Three cells were removed from test, due to high pressure, during the C/10, 24-hour charge at room ambient temperature. The voltage requirement of 1.480 volts was exceeded by the cells during the C/10, 24-hour charge at 20 C, although the end-of-charge voltage was below this value (1.466-1.475 volts). Average capacity out during the 20 C charge efficiency test was 0.84 AH which represents 48% and is below the minimum requirement of 55%. The cells exhibited no pressure decay during the open-circuit stand portion of the pressure versus capacity test, as all cells reached their voltage limit (1.550 volts) before their pressure reached 20 psia with the highest pressure being 8 psia during charge.

Harkness, J. D.↗