Search NASA⌕ Search

SEARCH · Search NASA

Results for “carbon dioxide measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precise Measurement of Carbon Dioxide Column by Passive Ground Based Sensor

Over the past four years we have developed a family of differential radiometers based upon the Fabry-Perot interferometers that exhibit very great sensitivity to changes in the atmospheric column of carbon dioxide, oxygen, and water vapor. Our instruments employ a solid Fabry-Perot etalon that is tuned to the proper wavelength by changing its temperature. The thickness of the etalon has been selected so that its multiple pass bands align with regularly space absorption features of the molecule under investigation. Using multiple absorption features improves the optical throughput of the instrument and improves the stability of the instrument response with respect to environmental changes. We are presently working to extend this technique to the carbon 13 isotope of carbon dioxide and to methane. Our instruments are intrinsically rugged and can be fabricated in a small package at relatively low cost.. As such they hold promise for widespread use in ground based networks for calibration and validation of satellite instruments such as OCO and GOSAT. Results will be presented for long term ground based operations of these systems. The effects of atmospheric scattering, pointing errors, pressure broadening and temperature effects will be discussed with regard to achieving precision better than .5% required for validation of carbon dioxide column measured from space. Finally we will outline the approach for extension of this methodology to additional molecular species of interest.

Heaps, William S.↗

Analysis of field measurements of carbon dioxide and water vapor fluxes

Analysis of the field measurements of carbon dioxide and water vapor fluxes is discussed. These data were examined in conjunction with reflectance obtained from helicopter mounted Modular Multiband Radiometer. These measurements are representative of the canopy scale (10 to 100 m)(exp 2) and provide a good basis for investigating the hypotheses/relationship potentially useful in remote sensing applications. All the micrometeorological data collected during FIFE-89 were processed and fluxes of CO2, water vapor, and sensible heat were calculated. Soil CO2 fluxes were also estimated. Employing these soil CO2 flux values, in conjunction with micrometeorological measurements, canopy photosynthesis is being estimated. A biochemical model of leaf photosynthesis was adapted to the prairie vegetation. The modeled leaf photosynthesis rates were scaled up to the canopy level. This model and a multiplicative stomatal conductance model are also used to calculate canopy conductance.

Verma, Shashi B.↗

Autonomous measurements of carbon dioxide uptake in a blue carbon habitat

A better understanding of carbon cycling dynamics in coastal ecosystems is critical to quantify “blue carbon” storage. However, obtaining the necessary measurements is complicated due to the dynamic conditions that characterize these ecosystems, and requires both spatially and temporally resolved measurements of carbon dioxide concentrations and complementary water quality parameters. In this study, we evaluate the use of a utility-class autonomous surface vehicle as a platform for measuring carbon dioxide dynamics in a shallow, intertidal, blue carbon ecosystem. We integrated a carbon dioxide sensor, a water quality sonde, and hydroacoustic sensors with an autonomous surface vehicle and performed measurements in and around a meadow of Zostera marina eelgrass. Results demonstrate the utility of this system to provide insight into complex carbon cycling dynamics in and around a shallow, intertidal blue carbon habitat.

54 ENVIRONMENTAL SCIENCES↗

A 4 U Laser Heterodyne Radiometer for Methane (CH4) and Carbon Dioxide (CO2) Measurements from an Occultation-Viewing CubeSat

We present a design for a 4 U (20 cm 20 cm 10 cm) occultation-viewing laser heterodyne radiometer (LHR) that measures methane (CH4), carbon dioxide (CO2) and water vapor(H2O) in the limb that is designed for deployment on a 6 U CubeSat. The LHR design collects sunlight that has undergone absorption by the trace gas and mixes it with a distributive feedback (DFB) laser centered at 1640 nm that scans across CO2, CH4, and H2O absorption features. Upper troposphere lower stratosphere measurements of these gases provide key inputs to stratospheric circulation models: measuring stratospheric circulation and its variability is essential for projecting how climate change will affect stratospheric ozone.

occultation↗

Measuring the Spectral Expression of Carbon Dioxide in the Solar Reflected Spectrum with AVIRIS

Carbon dioxide is a low-concentration, but important, component of the Earth's atmosphere. This gas absorbs electromagnetic radiation (EMR) in several regions of the spectrum. Absorption of energy by carbon dioxide adds heat to the atmosphere. In the world today, the burning of fossil fuels and other anthropogenic processes adds carbon dioxide to the atmosphere. Other natural processes in the Earth's system both add and remove carbon dioxide. Overall, measurements of atmospheric carbon dioxide at selected sites around the globe show an increased carbon dioxide concentration in the atmosphere. A figure shows the measured carbon dioxide from Mauna Loa, Hawaii, from 1958 to 2000. Overall, the concentration has increased from 315 to 365 ppm at this site over this period. (There is also a yearly cycle to the concentration that is timed with and hypothesized to be related to the vegetation growing season in the Northern Hemisphere.) The overall expected effect of this increase of atmospheric carbon dioxide is trapping of heat in the atmosphere and global warming. While this overall relationship between carbon dioxide and global warming seems straightforward, many of the specific details relating to regional and local sources and sinks and gradients of carbon dioxide are not well understood. A remote sensing capability to measure carbon dioxide could provide important inputs for scientific research to better understand the distribution and change in atmospheric carbon dioxide at detailed spatial and temporal levels. In pursuit of this remote sensing of carbon dioxide objective, this paper analyzes the expression of carbon dioxide in the spectral range measured by the Airborne Visible/Infrared Imagery Spectrometer (AVIRIS). Based on these analyses, a spectral-fitting algorithm that uses AVIRIS measured spectra and MODTRAN radiative-transfer code modeled spectra to derive total column carbon dioxide abundance has been developed. This algorithm has been applied to an AVIRIS data set acquired over Pasadena, California, in 1999 and a data set acquired over the Pacific Ocean near Hawaii in 2000 with promising results. This is ongoing research; the current initial analyses, measurements, and results are reported in this paper.

Green, Robert O.↗

Carbon Dioxide Flux Measurement System (CO2FLX) Instrument Handbook

The Southern Great Plains (SGP) carbon dioxide flux (CO2 flux) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), and sensible heat. The fluxes are obtained by the eddy covariance technique, which computes the flux as the mean product of the vertical wind component with CO2 and H2O densities, or estimated virtual temperature. A three-dimensional sonic anemometer is used to obtain the orthogonal wind components and the virtual (sonic) temperature. An infrared gas analyzer is used to obtain the CO2 and H2O densities. A separate sub-system also collects half-hour average measures of meteorological and soil variables from separate 4-m towers.

54 ENVIRONMENTAL SCIENCES↗

Carbon Dioxide Removal Measurement, Reporting, and Verification Simulation toolkit (CDR MRVSim) v0.1

CDR MRVSim is a statistical software toolkit for techno-economic analysis of measurement, reporting, and verification of multiple carbon dioxide removal technologies. The current version applies Monte Carlo simulation to existing datasets estimate the cost and uncertainty of measuring the soil organic carbon (SOC) content of agricultural land, accounting for multiple sources of uncertainty, using data from field measurements. We are planning to incorporate enhanced rock weathering and other technologies into the software. The current model leverages existing data to characterize underlying variability in soil organic carbon and related parameters, including bulk density, in an agricultural field attempting to increase its SOC. We then simulate baseline and post-intervention "measurement campaigns" in which some number of SOC and bulk density measurements are conducted using a selected technology. This enables estimates of the cost and accuracy of measuring changes in SOC in the simulated field. The primary advantages over similar software are: 1) ability to quantify tradeoffs between cost and uncertainty in MRV across a range of possible MRV approaches 2) focus on guiding development of novel sensors by determining desirable sets of characteristics

Sherwin, Evan [Lawrence Berkeley National Laborato↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.

Meginnis, Ian M.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

It is essential to provide adequate carbon dioxide (CO2) washout in a space suit to reduce the risks associated with manned operations in space suits. Symptoms of elevated CO2 levels range from reduced cognitive performance and headache to unconsciousness and death at high levels of CO2. Because of this, NASA imposes limits on inspired CO2 levels for space suits when they are used in space and for ground testing. Testing and/or analysis must be performed to verify that a space suit meets CO2 washout requirements. Testing for developmental space suits has traditionally used an oronasal mask that collects CO2 samples at the left and rights sides of the mouth. Testing with this mask resulted in artificially elevated CO2 concentration measurements, which is most likely due to the dead space volume at the front of the mask. The mask also extends outward and into the supply gas stream, which may disrupt the washout effect of the suit supply gas. To mitigate these problems, a nasal cannula was investigated as a method for measuring inspired CO2 based on the assumptions that it is low profile and would not interfere with the designed suit gas flow path, and it has reduced dead space. This test series compared the performance of a nasal cannula to the oronasal mask in the Mark III space suit. Inspired CO2 levels were measured with subjects at rest and at metabolic workloads of 1000, 2000, and 3000 BTU/hr. Workloads were achieved by use of an arm ergometer or treadmill. Test points were conducted at air flow rates of 2, 4, and 6 actual cubic feet per minute, with a suit pressure of 4.3 psid. Results from this test series will evaluate the accuracy and repeatability across subjects of the nasal cannula collection method, which will provide rationale for using a nasal cannula as the new method for measuring inspired CO2 in a space suit. Proper characterization of sampling methods and of suit CO2 washout capability will better inform requirements definition and verification techniques for future CO2 washout limits in space suits

Meginnis, I↗

Miniature carbon dioxide sensor

Sensor with no moving parts measures carbon dioxide partial pressures of 0 to 40 mm Hg for total pressures up to 14 psia with a full scale accuracy of 5 percent.

Mc Henry, T. F.↗

Novel Technique and Technologies for Active Optical Remote Sensing of Greenhouse Gases

The societal benefits of understanding climate change through identification of global carbon dioxide sources and sinks led to the desired NASA's active sensing of carbon dioxide emissions over nights, days, and seasons (ASCENDS) space-based missions of global carbon dioxide measurements. For more than 15 years, NASA Langley Research Center (LaRC) have developed several carbon dioxide active remote sensors using the differential absorption lidar (DIAL) technique operating at the two-micron wavelength. Currently, an airborne two-micron triple-pulse integrated path differential absorption (IPDA) lidar is under development. This IPDA lidar measures carbon dioxide as well as water vapor, the dominant interfering molecule on carbon dioxide remote sensing. Advancement of this triple-pulse IPDA lidar development is presented.

Singh, Upendra N.↗

Volcanic CO2 Abundance of Kilauea Plume Retrieved by Meand of AVIRIS Data

Absorbing the electromagnetic radiation in several regions of the solar spectrum, CO2 plays an important role in the Earth radiation budget since it produces the greenhouse effect. Many natural processes in the Earth s system add and remove carbon dioxide. Overall, measurements of atmospheric carbon dioxide at different sites around the world show an increased carbon dioxide concentration in the atmosphere. At Mauna Loa Observatory (Hawaii) the measured carbon dioxide increased from 315 to 365 ppm, in the period 1958 2000 [Keeling et al., 2001]. While at the large scale, the relationship between CO2 increase and global warming is established [IPCC, 1996], at the local scale, many studies are still needed to understand regional and local sources of carbon dioxide, such as volcanoes. The volcanic areas are particularly rich in carbon dioxide; this is due to magma degassing in the summit craters region of active volcanoes, and to the presence of fractures and active faults [Giammanco et al., 1998]. Several studies estimate a global flux of volcanic CO2 (34+/-24)10(exp 6) tons/day from effusive volcanic emissions, such as the tropospheric volcanic plume (Table 1) [McClelland et al., 1989]. Plumes are a turbulent mixture of gases, solid particles and liquid droplets, emitted continuously at high temperature from summit craters, fumarolic fields or during eruptive episodes. Inside the plume, water vapour represents 70 90% of the volcanic gases. The main gaseous components are CO2, SO2, HCl, H2, H2S, HF, CO, N2 and CH4. Other plume components are volcanic ash, aqueous and acid droplets and solid sulphur-derived particles [Sparks et al., 1997]. Volcanic gases and aerosols are evidences of volcanic activity [Spinetti et al., 2003] and they have important climatic and environmental effects [Fiocco et al., 1994]. For example, Etna volcano is one of the world s major volcanic gas sources [Allard et al., 1991]. New studies on volcanic gaseous emissions have pointed out that a variation of the gas ratio CO2/SO2 is related to eruptive episodes [Caltabiano et al., 1994]. However, measurements and monitoring of volcanic carbon dioxide are difficult and often hazardous, due to the high background presence of atmospheric CO2 and the inaccessibility of volcanic sites. Hyperspectral remote sensing is a suitable technique to overcome the difficulties of ground measurement. It permits a rapid, comprehensive view of volcanic plumes and their evolution over time, detection of all gases with absorption molecular lines within the sensor s multispectral range and, in general, measurement of all the volatile components evolving from craters. The molecular and particle plume components scatter and absorb incident solar radiation. The integral of the radiation difference composes the signal measured by the remote spectrometer. The inversion technique consists of retrieving the plume component concentrations, hence decomposing the signal into the different contributions. The accuracy of remote sensing techniques depends primarily on the sensor capability and sensitivity.

Spinetti, C.↗

Development of an Airborne Triple-Pulse 2-Micron Integrated Path Differential Absorption Lidar (IPDA) for Simultaneous Airborne Column Measurements of Carbon Dioxide and Water Vapor in the Atmosphere

This presentation will provide status and details of an airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar being developed at NASA Langley Research Center with support from NASA ESTO Instrument Incubator Program. The development of this active optical remote sensing IPDA instrument is targeted for measuring both atmospheric carbon dioxide and water vapor in the atmosphere from an airborne platform. This presentation will focus on the advancement of the 2-micron triple-pulse IPDA lidar development. Updates on the state-of-the-art triple-pulse laser transmitter will be presented including the status of seed laser locking, wavelength control, receiver and detector upgrades, laser packaging and lidar integration. Future plan for IPDA lidar system for ground integration, testing and flight validation will also be presented.

Singh, Upendra N.↗

Progress on Development of an Airborne Two-Micron IPDA Lidar for Water Vapor and Carbon Dioxide Column Measurements

An airborne 2 micron triple-pulse integrated path differential absorption (IPDA) lidar is currently under development at NASA Langley Research Center (LaRC). This lidar targets both atmospheric carbon dioxide (CO2) and water vapor (H2O) column measurements, simultaneously. Advancements in the development of this IPDA lidar are presented in this paper. Updates on advanced two-micron triple-pulse high-energy laser transmitter will be given including packaging and lidar integration status. In addition, receiver development updates will also be presented. This includes a state-of-the-art detection system integrated at NASA Goddard Space Flight Center. This detection system is based on a newly developed HgCdTe (MCT) electron-initiated avalanche photodiode (e-APD) array. Future plan for IPDA lidar system for ground integration, testing and flight validation will be discussed.

Singh, Upendra N.↗

Progress in Measurement of Carbon Dioxide Using a Broadband Lidar

In order to better understand the budget of carbon dioxide in the Earth's atmosphere it is necessary to develop a global high precision understanding of the carbon dioxide column. In order to uncover the 'missing sink" that is responsible for the large discrepancies in the budget as we presently understand it calculation has indicated that measurement accuracy on the order of 1 ppm is necessary. Because typical column average CO2 has now reached 380 ppm this represents a precision on the order of .25% for these column measurements. No species has ever been measured from space at such a precision. In recognition of the importance of understanding the CO2 budget in order to evaluate its impact on global warming the National Research Council in its decadal survey report to NASA recommended planning for a laser based total CO2 mapping mission in the near future. The extreme measurement accuracy requirements on this mission places very strong requirements on the laser system used for the measurement. This work presents an overview of the characteristics necessary in a laser system used to make this measurement. Consideration is given to the temperature dependence, pressure broadening, and pressure shift of the CO2 lines themselves and how these impact the laser system characteristics We have been examining the possibility of making precise measurements of atmospheric carbon dioxide using broad band source of radiation. This means that many of the difficulties in wavelength control can be treated in the detector portion of the system rather than the laser source. It also greatly reduces the number of individual lasers required to make a measurement. Simplifications such as these are extremely desirable for systems designed to operate from space.

Heaps, William S.↗

Progress in Measurement of Carbon Dioxide Using a Broadband LIDAR

Innovative active system using advanced source technology development will enable precise daytime or nighttime measurements of column CO2. Directly responds to NRC DS ASCENDS mission. Number of lasers is reduced compared to competing technologies which reduces the complexity of sensor and thus the cost and risk of failure. Knowledge gained from previously developed passive sensor decreases the risk and cost of the present lidar system development. The instrument can play a significant role as an intercomparison instrument for OCO (Orbiting Carbon Observatory) if it is rebuilt and launched as well as other laser based instruments under development for participation in ASCENDS. It can play a role as an airborne instrument in its own right in addressing the problems of scale arising from differences between point observations by the existing ground based CO2 network and wider area measurements obtained by satellites. Developed 2.0 micron broadband system as well and will compare performance of both systems to choose optimal approach for ASCENDS. Have begun development of approach that uses array detectors instead of APD. This approach will have lower noise than APD and may simplify design of the detector optical train.

Heaps, William S.↗