Search NASA⌕ Search

SEARCH · Search NASA

Results for “carryover”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Accelerating actinium-225 purification by high-pressure ion chromatography

Actinium-225 (t1/2 = 9.92 days) is an important radioisotope for targeted alpha therapy applications. The limited supply obtained through the decay of thorium-229 has motivated accelerator-based production routes, including irradiation of thorium targets. Irradiated targets can produce useful quantities of actinium-225, but the product requires final purification from chemically similar lanthanide contaminants. This work describes an automated high-pressure ion chromatography method for this final polishing step. The method uses a reusable strong-acid cation-exchange column bearing sulfonic acid functional groups. α-Hydroxyisobutyric acid (α-HIBA), adjusted to pH 4.3 with lithium hydroxide, complexes and elutes lanthanides, a dilute hydrochloric acid matrix-exchange step removes residual α-HIBA, and concentrated hydrochloric acid then elutes retained actinium(III). The protocol purified actinium-225 to >99% radiopurity across tracer-level samples and samples containing >150 µCi (5.6 MBq) of activity. A 10 min, 0.1 M hydrochloric acid matrix exchange substantially reduced organic eluent carryover, and in-line sodium iodide detection enabled real-time monitoring of actinium and lanthanide elution. The developed method can be completed in <1 h and provides a basis for automated purification workflows for accelerator-produced actinium-225.

Gaddis, Kevin [ORNL] (ORCID:0000000183398314)↗

An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant

As a promising alternative to inefficient vapor-compression-based air conditioning, liquid desiccant dehumidification uses a liquid desiccant in contact with the humid air absorbing the moisture. However, it has not gained much market share due to the issues related to the carryover, corrosion, fouling, and crystallization of liquid desiccant. The research has developed a new membrane-based exchanger, which uses a non-corrosive ionic liquid desiccant and nonporous tubular membranes to address these issues. As the second generation of the prototype, the new exchanger was tested at various operating conditions. According to the experimental data, when it is used in the dehumidification loop, the new membrane-based exchanger achieves a specific vapor transportation rate of 778.6 g/(h–m 2 ) and an average water vapor flux of 0.316 g/(h-m 2 -Pa), which is a significant improvement compared with the previous designs using nonporous membranes. It also achieved a comparable or even better dehumidification performance compared with the dehumidifiers that use porous membrane and conventional liquid desiccants. However, the regeneration performance is not as good as its dehumidification. It is mainly caused by the high operating temperature required in the regeneration loop. The experimental data and findings provide first-hand experimental data and enhance the understanding of advanced membrane-based ionic liquid desiccant systems.

42 ENGINEERING↗

One-dimensional, transient modeling of a fixed-bed regenerator as a replacement for recuperators in supercritical CO 2 power cycles

Fixed-bed regenerators may be a low cost alternative to recuperators for supercritical CO 2 power cycles. However, the transient nature of regenerators operating in sCO 2 power cycles has not been previously characterized. This study details a one-dimensional, transient model of a fixed-bed regenerator that captures phenomena such as local fluid properties and heat transfer coefficients, entrained fluid heat capacity, and the effects of conservation of mass during process switching. The model is validated with experimental results of a 10 kWth regenerator. This comparison shows that the model predicts temperature as a function of both time and space exceptionally well. The model predicts effectiveness, heat transfer, and discharge temperatures within 5%, and predicts pressure drop and fluid carryover within 10%. This model could be used in future studies to simulate regenerators within a supercritical CO 2 power cycle.

30 DIRECT ENERGY CONVERSION↗

Development of small-scale plutonium electrorefining in molten CaCl 2

Molten salt extraction and electrorefining of plutonium were successfully conducted with only a 200-g initial charge. Due to this small scale, the electrorefining cell components were redesigned relative to conventional, multi-kg standards. The efficiency and yield of this small-scale process are comparable to those of larger-scale exemplars. Chemical analysis of the plutonium product and the anode heel is presented. Here, the product was 99.8% pure. The anode heel was able to be depleted beyond the expected freezing point without significant impurity carryover.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Hypoxia-cultured mouse mesenchymal stromal cells from bone marrow and compact bone display different phenotypic traits

Highlights: • Mouse compact bone is richer in MSC compared to central bone marrow. • Derivation of MSC from mouse compact bone is associated with lower risk of contamination with hematopoietic cells. • MSC from compact bone display higher osteogenic differentiation capacity than bone marrow MSC. It has been suggested that the bone marrow microenvironment harbors two distinct populations of mesenchymal stromal cells (MSC), one with a perivascular location and other present in the endosteum. A better understanding of the biology of these MSC subsets has been pursued in order to refine its clinical application. However, most comparative characterizations of mouse MSC have been performed in normoxia. This can result in misleading interpretations since mouse MSC subsets with low/defective p53 activity are known to be selected during culture in normoxia. Here, we report a comprehensive in vitro characterization of mouse MSC isolated from bone marrow (BM-MSC) and compact bone (CB-MSC) expanded and assayed under hypoxia for their morphology, clonogenic efficiency and differentiation capacity. We found that, under hypoxia, compact bone is richer in absolute numbers of MSC and isolation of MSC from compact bone is associated with a reduced risk of hematopoietic cell carryover. In addition, CB-MSC have higher in vitro osteogenic capacity than BM-MSC, while adipogenic differentiation potential is similar. These findings reinforce the hypothesis of the existence of MSC in bone marrow and compact bone representing functionally distinct cell populations and highlight the compact bone as an efficient source of murine MSC under physiological oxygen concentrations.

60 APPLIED LIFE SCIENCES↗

Stress Testing California's Hydroclimatic Whiplash: Potential Challenges, Trade‐Offs and Adaptations in Water Management and Hydropower Generation

Abstract Inter‐annual precipitation in California is highly variable, and future projections indicate an increase in the intensity and frequency of hydroclimatic “whiplash.” Understanding the implications of these shocks on California's water system and its degree of resiliency is critical from a planning perspective. Therefore, we quantify the resilience of reservoir services provided by water and hydropower systems in four basins in the western Sierra Nevada. Using downscaled runoff from 10 climate model outputs, we generated 200 synthetic hydrologic whiplash sequences of alternating dry and wet years to represent a wide range of extremes and transitional conditions used as inputs to a water system simulation model. Sequences were derived from upper (wet) and lower (dry) quintiles of future streamflow projections (2030–2060). Results show that carryover storage was negatively affected in all basins, particularly in those with lower storage capacity. All basins experienced negative impacts on hydropower generation, with losses ranging from 5% to nearly 90%. Reservoir sizes and inflexible operating rules are a particular challenge for flood control, as in extremely wet years spillage averaged nearly the annual basins' total discharge. The reliability of environmental flows and agricultural deliveries varied depending on the basin, intensity, and duration of whiplash sequences. Overall, wet years temporarily rebound negative drought effects, and greater storage capacity results in higher reliability and resiliency, and lesser volatility in services. We highlight potential policy changes to improve flexibility, increase resilience, and better equip managers to face challenges posed by whiplash while meeting human and environmental needs.

Environmental Sciences & Ecology↗

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Here, an automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO 2 F 2 ), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO 3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235 U/ 238 U and 234 U/ 238 U isotope ratios for the UO 2 F 2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of –0.041% and –1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235 U/ 238 U isotope ratio of 0.00206(7), a –0.96% relative difference from the reference value of 0.00208(1). The 234 U/ 238 U and 236 U/ 238 U isotope ratios were 0.000008(1) and 0.000031(4), –5.1% RD and –4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface – including blanks, mass bias, and triplicate extractions – was completed in less than an hour without any sample preparation necessary.

47 OTHER INSTRUMENTATION↗

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

Documenting Development of Processing Parameters for Fabrication of Doped and Undoped Fuel Pellets (Summary Report)

Early FY20 restructuring of the TREAT work package FT-20LA02020608 Enriched Fuel Fabrication for Safety Testing, and associated deliverables necessitated the rescoping of existing LANL deliverables. This rescoped carryover report summarizes work to date on doped and undpoped fuel pellet fabrication development of proceeding parameters. This summary also includes a status update of intended research activities that fall under the activity associated with this work package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls from the Tank 49H B4 downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. The scope of this task is to perform fluid flow analysis to determine the impact of a “plunging jet” through the B4 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF.

54 ENVIRONMENTAL SCIENCES↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Impact of Additional Manganese from the Recycle Collection Tank (RCT) Glycolate Destruction Process on Glass Properties

The Defense Waste Processing Facility (DWPF) is planning to implement glycolic acid as a reductant within the waste processing flowsheet. An assessment of the glycolic acid flowsheet has revealed the potential for thermolytic production of hydrogen in the Concentration, Storage and Transfer Facilities (CSTF) from glycolate entrained in the DWPF recycle stream. To mitigate this potential scenario, a glycolate destruction process utilizing sodium permanganate (NaMnO 4 ) is being developed for use in the DWPF Recycle Collection Tank (RCT). The RCT is fed by the Slurry Mix Evaporator Condensate Tank (SMECT) and the Off-Gas Condensate Tank (OGCT). The SMECT could receive glycolate via a foamover from the Sludge Receipt and Adjustment Tank (SRAT) or the Slurry Mix Evaporator (SME), and the OGCT could receive glycolate via carryover of sludge particles in the purge from the melter during surge conditions. The use of NaMnO 4 additions in the RCT will result in additional manganese (Mn) in the waste stream and needs to be evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Organic Evaporation and Oxidation Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method to supplement vitrification. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. This work evaluates potential avenues to eliminate that impediment to permit possible use of a cementitious waste form and work towards a decision whether additional LDR organic pretreatment would be required. Savannah River National Laboratory (SRNL) performed testing using simulants to examine evaporation as a method to remove some prevalent organics from LAW. Spiking the caustic LAW simulant with selected regulated organic chemicals found one that clearly decomposes because of caustic instability. Oxidation testing of other organic chemicals found some LDR organics degrade as desired and others are stable in the presence of peroxide and permanganate. In addition to studies with simulants, a literature review was performed to evaluate radiological stability of LDR organics. Descriptions of the experimental details, equipment, and results are included in this report. Evaporation testing consisted of preparing the LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation) and also at atmospheric pressure. The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na + ] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species. Organic chemicals were chosen for the work with a consideration of how their volatility compares with that of methanol. This was done by comparing the ratio of the pure water Henry’s law coefficient (K h ) of methanol to that of the compound in question (hereafter termed the K h ratio), where ratios above unity indicated less volatility than methanol. Methanol was chosen because it is a common regulated chemical with relatively low volatility but which has been removed by evaporation in previous laboratory work. While organic separation results depend on evaporator design, laboratory experiments verified that organic partitioning to the overhead condensate stream by evaporation is a practical process. The work reported here found difficulties in quantitative analysis of the organic chemicals in aqueous samples. Most of the time there was insufficient analysis to close a mass balance for evaporator runs, but qualitative evidence of carryover was obtained. The methods were also able to show whether organic chemicals were susceptible or resistant to solution oxidation in permanganate or hydrogen peroxide tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on Initial Tribological Studies of Graphite in Dry Argon and Molten Salt Environment

This report documents completion of the Advanced Reactor Technologies (ART) Level 2 Milestone M2TG-24OR0501081: “Complete report on initial tribological studies within molten salt environment”, due January 31, 2024. This milestone is a carryover milestone from FY23 M2TG-23OR0501091. The report summarizes the initial studies on tribological characterization of the graphite–graphite sliding interface in a dry argon and molten FLiNaK salt environment. The experiments were conducted on a high-temperature multifunctional tribometer placed in a glovebox. This configuration enables probing the wear and friction properties at high temperatures in an inert environment. The worn surfaces were analyzed using high-resolution microscopy and white-light profilometry to determine the wear modes and wear rates. This report discusses the previous wear and friction studies on 316H stainless steel (SS) sliding against graphite in molten salt for different temperatures, sliding speeds, and salt amount. Moreover, key tribological parameters of pebble-on-pebble interaction in gas-cooled and molten salt reactors (MSRs) are analyzed and used to design an experimental test matrix for future studies. The outcomes of this project could provide key information about the tribological behavior of graphite pebbles in gas-cooled and MSRs, thereby contributing to safer operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Z Facility Sustainment Status (November FY 2024) [Slides]

FY24 sustainment project list has been revised resulting in sixteen projects. Total budget for the finalized project list is $9,570,968 (includes FY23 Carryover and FY24). Key factors for project selection included: risk mitigation to address operations highest failure risk subsystems, purchase of long lead parts to address life limited parts, and completion of multi phase sustainment projects initiated in prior year. Given the backlog of projects and limited FY24 funding, there are identified projects that are not included in the final project list that could reduce future Z facility failure risk. Should additional budget become available, these identified projects can be kicked off.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗