Search NASA⌕ Search

SEARCH · Search NASA

Results for “ceramic implants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source

The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1–10 mm{sup 2}. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

36 MATERIALS SCIENCE↗

Radiation damage of hollandite in multiphase ceramic waste forms

Radiation damage was simulated in multiphase titanate-based ceramic waste forms using an ion accelerator to generate high energy alpha particles (He + ) and an ion implanter to generate 7 MeV gold (Au 3+ ) particles. X-ray diffraction and transmission electron microscopy were used to characterize the damaged surfaces and nearby regions. Simulated multiphase ceramic waste forms were prepared using two processing methods: spark plasma sintering and melt-processing. Both processing methods produced ceramics with similar phase assemblages consisting of hollandite-, zirconolite/pyrochlore-, and perovskite- type phases. The measured heavy ion (Au 3+ ) penetration depth was less in spark plasma sintered samples than in melt-processed samples. Furthermore, structural breakdown of the hollandite phase occurred under He + irradiation indicated by the presence of x-ray diffraction peaks belonging to TiO 2 , BaTiO 5 , and other hollandite related phases (Ba 2 Ti 9 O 20 ). The composition of the constituent hollandite phase affected the extent of damage induced by Au 3+ ions.

36 MATERIALS SCIENCE↗

Investigation of Bone Growth in Additive-Manufactured Pedicle Screw Implant by Using Ti-6Al-4V and Bioactive Glass Powder Composite

In this study, we optimized the geometry and composition of additive-manufactured pedicle screws. Metal powders of titanium-aluminum-vanadium (Ti-6Al-4V) were mixed with reactive glass-ceramic biomaterials of bioactive glass (BG) powders. To optimize the geometry of pedicle screws, we applied a novel numerical approach to proposing the optimal shape of the healing chamber to promote biological healing. We examined the geometry and composition effects of pedicle screw implants on the interfacial autologous bone attachment and bone graft incorporation through in vivo studies. The addition of an optimal amount of BG to Ti-6Al-4V leads to a lower elastic modulus of the ceramic-metal composite material, effectively reducing the stress-shielding effects. Pedicle screw implants with optimal shape design and made of the composite material of Ti-6Al-4V doped with BG fabricated through additive manufacturing exhibit greater osseointegration and a more rapid bone volume fraction during the fracture healing process 120 days after implantation, per in vivo studies.

stress-shielding effect↗

Direct hydrothermal synthesis of hydroxyapatite/alumina nanocomposite

Hydrothermal synthesis offers numerous advantages such as: control over product homogeneity, nucleation, growth and aging. This leads to the control of particle aggregation, size uniformity and morphology over conventional and non-conventional ceramic synthesis methods. In the present work, a novel procedure for the direct synthesis of Hydroxyapatite (HAp)/alumina nanocomposite in a hydrothermal vessel with continuous stirring was investigated, where the effects of different concentration of aluminium nitrate were also studied. The optimized concentration of starting material for the characteristic formation of HAp/alumina composite (hexagonal HAp and monoclinic alumina phases) was determined by X-ray diffraction (XRD) study. The size distribution of HAp/alumina composite was found as 100 nm by electron microscopy and EDAX revealed that the concentration of alumina in the HA4 was ~ 10%, which is more suitable for biomedical implant. Further, the cytotoxicity study against MG 63 cells showed that HA4 was biocompatible even at higher concentration (200 μg/ml). Hence, the direct synthesis of HAp/alumina composite without the formation of any intermediate like calcium aluminate could be used as a novel approach to prepare HAp based biomedical implants.

36 MATERIALS SCIENCE↗

Ceramics Based on Powder Mixtures Containing Calcium Hydrogen Phosphates and Sodium Salts (Na{sub 2}CO{sub 3}, Na{sub 4}P{sub 2}O{sub 7}, and NaPO{sub 3})

Ceramic materials in the Na{sub 2}O–CaO–P{sub 2}O{sub 5} system have been produced using powder mixtures containing calcium hydrogen phosphates (monetite/brushite: CaHPO{sub 4}/CaHPO{sub 4} ∙ 2H{sub 2}O) and sodium salts (Na{sub 2}CO{sub 3} ∙ H{sub 2}O, Na{sub 4}P{sub 2}O{sub 7} ∙ 10H,O, and NaPO{sub 3}). These salts were used as precursors to the following high-temperature phases: Сa{sub 2}P{sub 2}O{sub 7}, Na{sub 2}O, Na{sub 4}P{sub 2}O{sub 7}, and NaPO{sub 3}. The amount of the salts in the powder mixtures was such that the oxide composition of the ceramics corresponded to 10 mol % sodium oxide for each mixture in the Na{sub 2}O–CaO–P{sub 2}O{sub 5} system. The powder mixtures were prepared using mechanical activation in acetone, which was accompanied by monetite rehydration to brushite. X-ray diffraction characterization showed that, after firing, the phase composition of the ceramics produced from the powder mixtures thus prepared lay in the Сa{sub 2}P{sub 2}O{sub 7}–NaCaPO{sub 4}–Na{sub 2}СaP{sub 2}O{sub 7}–Са(РО{sub 3}){sub 2} phase field. The resultant ceramic materials contain biocompatible and bioresorbable phases and can be recommended for bone implant fabrication.

36 MATERIALS SCIENCE↗

Resources for a lunar base: Rocks, minerals, and soil of the Moon

The rocks and minerals of the Moon will be included among the raw materials used to construct a lunar base. The lunar regolith, the fragmental material present on the surface of the Moon, is composed mostly of disaggregated rocks and minerals, but also includes glassy fragments fused together by meteorite impacts. The finer fraction of the regolith (i.e., less than 1 cm) is informally referred to as soil. The soil is probably the most important portion of the regolith for use at a lunar base. For example, soil can be used as insulation against cosmic rays, for lunar ceramics and abodes, or for growing plants. The soil contains abundant solar-wind-implanted elements as well as various minerals, particularly oxide phases, that are of potential economic importance. For example, these components of the soil are sources of oxygen and hydrogen for rocket fuel, helium for nuclear energy, and metals such as Fe, Al, Si, and Ti.

Taylor, Lawrence A.↗

Status and directions of modified tribological surfaces by ion processes

An overview is presented of recent advances in modifying contacting surfaces in motion by the various ion assisted surface coating/modification processes to reduce and control tribological failures. The ion assisted coating processes and the surface modification processes offer the greatest potential to custom tailor and optimize the tribological performance. Hard, wear resistant and low shear coatings deposited by the ion assisted processes are discussed. Primarily the recent advances of sputtered MoS2 ion plated Au, Ag, Pb lubricating films and sputtered and ion plated hard, wear resistant TiN, HfN, TiC films are described in terms of structural property performance interrelationships which lead to improved adhesion, cohesion, nucleation, morphological growth, density, film thickness as determined by structural and chemical characterization and frictional and wear behavior. Also, the recent tribological advances using the surface modification processes such as ion implantation, ion beam mixing is discussed with emphasis on the development of lubricous high temperature ceramic surfaces.

Spalvins, Talivaldis↗

Diopside (CaO-MgO-2SiO2)-fluorapatite (9CaO-3P2O5-CaF2) glass-ceramics: Potential materials for bone tissue engineering

Glass-ceramics in the diopside (CaMgSi2O6) - fluorapatite [Ca5(PO4)3F] system are potential candidates for restorative dental and bone implant materials. In the present study, a series of glasses along diopside - fluorapatite binary system have been prepared with varying diopside/fluorapatite ratios for their potential applications in bone tissue engineering. The glasses were obtained from compositions with fluorapatite contents varying between 0-40 wt.%. The sintering ability and crystallization kinetics of as obtained amorphous glasses have been studied through hot-stage microscopy (HSM) and differential thermal analysis (DTA), respectively while crystalline phase evolution in sintered GCs has been followed by X-ray diffraction (XRD) adjoined with Rietveld-R.I.R. technique and scanning electron microscopy (SEM). Further, biodegradation and apatite forming ability of glass-ceramics were investigated by immersion of glass-ceramic discs in simulated body fluid (SBF) solution while chemical degradation and weight loss of glass-ceramics were studied by immersion in Tris-HCl in accordance with standard ISO 10993-14. The addition of fluorapatite (10-25 wt.%) in diopside glass system significantly enhanced the sintering ability of glass-ceramics and improved their apatite forming ability along with their biodegradation behaviour. Moreover, the in vitro cellular responses to glass-ceramics showed good cell viability and significant stimulation of osteoblastic differentiation, suggesting the possible use of the glass-ceramics for bone regeneration.

58 GEOSCIENCES↗

Reliability of scanning laser acoustic microscopy for detecting internal voids in structural ceramics

The reliability of 100 MHz scanning laser acoustic microscopy (SLAM) for detecting internal voids in sintered specimens of silicon nitride and silicon carbide was evaluated. The specimens contained artificially implanted voids and were positioned at depths ranging up to 2 mm below the specimen surface. Detection probability of 0.90 at a 0.95 confidence level was determined as a function of material, void diameter, and void depth. The statistical results presented for void detectability indicate some of the strengths and limitations of SLAM as a nondestructive evaluation technique for structural ceramics.

Roth, D. J.↗

Reliability of scanning laser acoustic microscopy for detecting internal voids in structural ceramics

The reliability of 100 MHz scanning laser acoustic microscopy (SLAM) for detecting internal voids in sintered specimens of silicon nitride and silicon carbide was evaluated. The specimens contained artificially implanted voids and were positioned at depths ranging up to 2 mm below the specimen surface. Detection probability of 0.90 at a 0.95 confidence level was determined as a function of material, void diameter, and void depth. The statistical results presented for void detectability indicate some of the strengths and limitations of SLAM as a nondestructive evaluation technique for structural ceramics.

Roth, D. J.↗

Physical and Tribological Characteristics of Ion-Implanted Diamond Films

Unidirectional sliding friction experiments were conducted with a natural, polished diamond pin in contact with both as-deposited and carbon-ion-implanted diamond films in ultrahigh vacuum. Diamond films were deposited on silicon, silicon carbide, and silicon nitride by microwave-plasma-assisted chemical vapor deposition. The as-deposited diamond films were impacted with carbon ions at an accelerating energy of 60 keV and a current density of 50 micron A/cm(exp 2) for approximately 6 min, resulting in a dose of 1.2 x 10(exp 17) carbon ions/cm(exp 2). The results indicate that the carbon ion implantation produced a thin surface layer of amorphous, nondiamond carbon. The nondiamond carbon greatly decreased both friction and wear of the diamond films. The coefficients of friction for the carbon-ion-implanted, fine-grain diamond films were less than 0.1, factors of 20 to 30 lower than those for the as-deposited, fine-grain diamond films. The coefficients of friction for the carbon-ion-implanted, coarse-grain diamond films were approximately 0.35, a factor of five lower than those for the as-deposited, coarse-grain diamond films. The wear rates for the carbon-ion-implanted, diamond films were on the order of 10(exp -6) mm(exp 3)/Nm, factors of 30 to 80 lower than that for the as-deposited diamond films, regardless of grain size. The friction of the carbon-ion-implanted diamond films was greatly reduced because the amorphous, nondiamond carbon, which had a low shear strength, was restricted to the surface layers (less than 0.1 micron thick) and because the underlying diamond materials retained their high hardness. In conclusion, the carbon-ion-implanted, fine-grain diamond films can be used effectively as wear resistant, self-lubricating coatings for ceramics, such as silicon nitride and silicon carbide, in ultrahigh vacuum.

Miyoshi, K.↗

Bioactive glass-ceramic coatings prepared by pulsed laser deposition from RKKP targets (sol-gel vs melt-processing route)

Highlights: Black-Right-Pointing-Pointer Bioactive glass-ceramic coatings for bone tissue repair and regeneration. Black-Right-Pointing-Pointer Pulsed Lased Deposition allowed congruent transfer of target composition to coating. Black-Right-Pointing-Pointer Target was prepared by sol-gel process suitable for compositional tailoring. Black-Right-Pointing-Pointer Titanium, widely used for orthopaedics and dental implants, was used as substrate. Black-Right-Pointing-Pointer The physico-chemical properties of the prepared coatings are reported. -- Abstract: The deposition of innovative glass-ceramic composition (i.e. RKKP) coatings by Pulsed Lased Deposition (PLD) technique is reported. RKKP was synthesised following two methodologies: melt-processing and sol-gel, the latter being particularly suitable to tailor the compositional range. The PLD advantage with respect to other deposition techniques is the congruent transfer of the target composition to the coating. The physico-chemical properties of films were investigated by Scanning Electron and Atomic Force Microscopies, Fourier Transform Infrared Spectroscopy, Angular and Energy Dispersive X-ray Diffraction, and Vickers microhardness. The deposition performed at 12 J/cm{sup 2} and 500 Degree-Sign C allows to prepare crystalline films with the composition that replicates rather well that of the initial targets. The 0.6 {mu}m thin melt-processing RKKP films, possessing the hardness of 25 GPa, and the 4.3 {mu}m thick sol-gel films with the hardness of 17 GPa were obtained.

36 MATERIALS SCIENCE↗

Surface properties, crystallinity and optical properties of anodised titanium in mixture of β-glycerophosphate (β-GP) and calcium acetate (CA)

Anodic oxidation is an electrochemical method for the production of ceramic films on a metallic substrate. It had been widely used to deposit the ceramic coatings on the metals surface. This method has been widely used in surface modification of biomaterials especially for dental implants. In this study, the surface morphology, crystallinity and optical properties of titanium foil was modified by anodising in mixture of β-glycerophosphate disodium salt pentahydrate (β-GP) and calcium acetate monohydrate (CA). The experiments were carried out at high voltage (350 V), different anodising time (5 and 10 minutes) and current density (10-70 mA.cm{sup −2}) at room temperature. Anodised titanium was characterised by using field emission scanning electron microscopy (FESEM), X-ray diffractometer (XRD), and UV-Vis spectrometry. The result of the experiment showed that surface morphology, crystallinity and optical properties depended strongly on the current density and anodising time. More porous surface and large amount of anatase and rutile was produced at higher current density and longer anodising time. Apart from that, it is also revealed that the energy band gap of anodised titanium increases as the increase in current density due to the presence of anatase and rutile TiO{sub 2}.

36 MATERIALS SCIENCE↗

Effect of surface texture by ion beam sputtering on implant biocompatibility and soft tissue attachment

The objectives in this report were to use the ion beam sputtering technique to produce surface textures on polymers, metals, and ceramics. The morphology of the texture was altered by varying both the width and depth of the square pits which were formed by ion beam erosion. The width of the ribs separating the pits were defined by the mask used to produce the texture. The area of the surface containing pits varies as the width was changed. The biological parameters used to evaluate the biological response to the texture were: (1) fibrous capsule and inflammatory response in subcutaneous soft tissue; (2) strength of the mechanical attachment of the textured surface by the soft tissue; and (3) morphology of the epidermal layer interfacing the textured surface of percutaneous connectors. Because the sputter yield on teflon ribs was approximately an order of magnitude larger than any other material the majority of the measurements presented in the report were obtained with teflon.

Gibbons, D. F.↗

Application of modern surface analytical tools in the investigation of surface deterioration processes

Surface profilometry and scanning electron microscopy were utilized to study changes in the surface of polymers when eroded. The X-ray photoelectron spectroscopy (XPS) and depth profile analysis indicate the corrosion of metal and ceramic surfaces and reveal the diffusion of certain species into the surface to produce a change in mechanical properties. Ion implantation, nitriding and plating and their effects on the surface are characterized. Auger spectroscopy analysis identified morphological properties of coatings applied to surfaces by sputter deposition.

Buckley, D. H.↗

Biocompatibility of a novel heat-treated and ceramic-coated magnesium alloy (Mg–1.2Zn–0.5Ca–0.5Mn) for resorbable skeletal fixation devices

Our recent exploration into the use of biodegradable metals and surface treatments resulting in sufficient strength for skeletal reconstruction applications has led to the need to test these devices’ cytotoxicity. More specifically, our group has developed a resorbable magnesium alloy, Mg–1.2Zn–0.5Ca–0.5Mn, that can be strengthened by heat treatment and coated with a ceramic layer offering time-certain resorption of a medical device. This in vitro study shows that these treatments do not result in cytotoxicity. Both heat-treated (HT) and HT + ceramic-coated (sol–gel) coupons demonstrated more than 70% viability. Thus, these processing steps are likely to be useful in producing biocompatible, resorbable implants that incorporate our Mg–1.2Zn–0.5Ca–0.5Mn alloy.

36 MATERIALS SCIENCE↗

Sliding seal materials for low heat rejection engines

Sliding friction coefficients and wear rates of promising piston seal materials were measured under temperature, environmental, velocity, and loading conditions that are representative of the low heat rejection (LHR) diesel engine environment. These materials included carbides, oxides, and nitrides. In addition, silicon nitride and partially stablized zirconia disks (cylinder liners) were ion-implanted with TiNi, Ni, Co, and Cr, and subsequently run against carbide pins (piston rings), with the objective of producing reduced friction via solid lubrication at elevated temperature. Friction and wear measurements were obtained using pin-on-disk laboratory experiments and a unique engine friction test rig. Unmodified ceramic sliding couples were characterized at all temperatures by friction coefficients of 0.24 and above during the pin-on-disk tests. The coefficient at 800 C in an oxidizing environment was reduced to below 0.1, for certain material combination, by the ion-implantation of TiNi or Co. This beneficial effect was found to derive from the lubricious Ti, Ni, and Co oxides. Similar results were demonstrated on the engine friction test rig at lower temperatures. The structural integrity and feasibility of engine application with the most promising material combination were demonstrated during a 30-hour single-cylinder, direct-injection diesel engine test.

Beaty, Kevin↗