Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Proton-Induced Transients and Charge Collection Mechanisms in a LWlR HgCdTe Focal Plane Array

Low noise performance of IR detectors is required, even in the presence of charged particles. Galactic cosmic rays, trapped protons & solar energetic particles. Particle induced transients identified as an important source of noise on ESA's ISO satellite. Also observed on NICMOS Instrument on NASA% Hubble Space Telescope. Tools to analyse particle induced transients have been developed. To date, comparisons of model have been made to flight data for a HgCdTe array exposed to trapped protons, and to a Si array exposed to laboratory protons. We report ground based proton transient measurements in a modem LWlR HgCdTe array operating under cryogenic conditions. Demonstration of charge collection mechanisms. Provide benchmarks for modeling tools.

Marshall, Paul↗

Diffusion length measurements in bulk and epitaxially grown 3-5 semiconductors using charge collection microscopy

Diffusion lengths and surface recombination velocities were measured in GaAs diodes and InP finished solar cells. The basic techniques used was charge collection microscopy also known as electron beam induced current (EBIC). The normalized currents and distances from the pn junction were read directly from the calibrated curves obtained while using the line scan mode in an SEM. These values were then equated to integral and infinite series expressions resulting from the solution of the diffusion equation with both extended generation and point generation functions. This expands previous work by examining both thin and thick samples. The surface recombination velocity was either treated as an unknown in a system of two equations, or measured directly using low e(-) beam accelerating voltages. These techniques give accurate results by accounting for the effects of surface recombination and the finite size of the generation volume.

Leon, R. P.↗

Diffusion length measurement in bulk and epitaxially grown III-V semiconductors using charge collection microscopy

Diffusion lengths and surface recombination velocities were measured in GaAs diodes and InP finished solar cells. The basic technique used was charge collection microscopy, also known as electron beam induced current (EBIC). The normalized currents and distances from the pn junction were read directly from the calibrated curves obtained while using the line-scan mode in an SEM. These values were then equated to integral and infinite series expressions resulting from the solution of the diffusion equation with both extended-generation and point-generation functions. This expands previous work by examining both thin and thick samples. The surface recombination velocity was either treated as an unknown in a system of two equations or measured directly using low e(-) beam accelerating voltages. These techniques give accurate results by accounting for the effects of surface recombination and the finite size of the generation volume.

Leon, R. P.↗

Simulation of Charge Collection to Spacecraft Surfaces: Freja Satellite

As spacecraft travel through plasma, spacecraft surfaces become charged by the collection of charged particles. This process is referred to as Surface Charging. These charges can be detrimental to the vehicle's electronic subsystems as they present a threat of electrostatic discharge (ESD) to onboard circuitry. The process of Surface Charging is complex and is affected by many elements. The charging of each surface is unique. The potential of an individual surface is dependent upon many variables including but not limited to the surface's geometry, material and its location. Each surface also has unique interactions with the surrounding plasma. Other factors that play large roles in the charging process is the density and temperature of plasma ions and electrons. Using Nascap-2k, a model of the Freja satellite has been constructed, and its auroral plasma environment has been imitated to simulate surface charging characteristics. The charging process of the Freja satellite has been modeled iteratively with incremental changes in both the Maxwellian electron temperature (eV) as well as the Gaussian electron energy (eV). This study provides an analysis of the sensitivity between spacecraft surface charging and these two primary variables of electron differential flux.

Wolfley, Olivia H.↗

Simulation of Charge Collection to Spacecraft Surfaces: Freja Satellite

As spacecraft travel through space plasma, spacecraft surfaces become charged by the collection of charged particles. This process is referred to as Surface Charging. These charges can be detrimental to the vehicle's electronic subsystems as they present a threat of electrostatic discharge (ESD) to onboard circuitry. The process of Surface Charging is complex and is affected by many elements. The charging of each surface is unique. The potential of an individual surface is dependent upon many variables including but not limited to the surface's geometry, material and its location. Each surface also has unique interactions with the surrounding plasma. Other factors that play large roles in the charging process is the density and temperature of plasma ions and electrons. Using Nascap-2k, a model of the Freja satellite has been constructed, and its auroral plasma environment has been imitated to simulate surface charging characteristics. The charging process of the Freja satellite has been modeled iteratively with incremental changes in both the Maxwellian electron temperature (eV) as well as the Gaussian electron energy (eV). This study provides an analysis of the sensitivity between spacecraft surface charging and these two primary variables of electron differential flux.

Wolfley, Olivia Hope↗

Characterizing SRAM Single Event Upset in Terms of Single and Double Node Charge Collection

A well-collapse source-injection mode for SRAM SEU is demonstrated through TCAD modeling. The recovery of the SRAM s state is shown to be based upon the resistive path from the p+-sources in the SRAM to the well. Multiple cell upset patterns for direct charge collection and the well-collapse source-injection mechanisms are then predicted and compared to recent SRAM test data.

Black, J. D.↗

Charge collection during hypervelocity penetrations of thin foils

The following represents trajectory sensor development work for the space-station-based Cosmic Dust Collection Facility (CDCF). This facility-class payload was to expose some 7 sq m of NASA-provided general-user instruments in addition to three instruments provided by formally selected principal investigators. The preferred trajectory sensor for this general-user instrument envisioned the detection of impact-triggered plasma for both velocity measurement and location instruments. Space station developments in late 1992/early 1993 lead to cancellation of this potential flight project, for both technical and fiscal reasons. This precipitated termination of all plasma detection work at JSC on behalf of CDCF's general-user instrument. The following comprises three informal reports that summarize the CDCF efforts regarding plasma sensing for trajectory determinations. The reports were initially written for internal CDCF use and were not widely distributed. Because no formal publications are envisioned at present, the three reports are included in full in this document. They not only demonstrate that substantial progress was accomplished in the development of plasma trajectory sensors during 1990-1992, but the results are hopefully of interest and use to others who may continue these developments. The chronological sequence of these three reports is reversed, with the first containing the latest information.

Peterson, Robert B.↗

The future scientific CCD

Since the first introduction of charge-coupled devices (CCDs) in 1970, CCDs have been considered for applications related to memories, logic circuits, and the detection of visible radiation. It is pointed out, however, that the mass market orientation of CCD development has left largely untapped the enormous potential of these devices for advanced scientific instrumentation. The present paper has, therefore, the objective to introduce the CCD characteristics to the scientific community, taking into account prospects for further improvement. Attention is given to evaluation criteria, a summary of current CCDs, CCD performance characteristics, absolute calibration tools, quantum efficiency, aspects of charge collection, charge transfer efficiency, read noise, and predictions regarding the characteristics of the next generation of silicon scientific CCD imagers.

Janesick, J. R.↗

Scientific charge-coupled devices

The charge-coupled device dominates an ever-increasing variety of scientific imaging and spectroscopy applications. Recent experience indicates, however, that the full potential of CCD performance lies well beyond that realized in devices currently available.Test data suggest that major improvements are feasible in spectral response, charge collection, charge transfer, and readout noise. These properties, their measurement in existing CCDs, and their potential for future improvement are discussed in this paper.

Janesick, James R.↗

Radiation effects studies for the high-resolution spectrograph

The generation and collection of charge carriers created during the passage of energetic protons through a silicon photodiode array are modeled. Pulse height distributions of noise charge collected during exposure of a digicon type diode array to 21 and 75 MeV protons were obtained. The magnitude of charge collected by a diode from each proton event is determined not only by diffusion, but by statistical considerations involving the ionization process itself. Utilizing analytical solutions to the diffusion equation for transport of minority carriers, together with the Vavilov theory of energy loss fluctuations in thin absorbers, simulations of the pulse height spectra which follow the experimental distributions fairly well are presented and an estimate for the minority carrier diffusion length L sub d is provided.

Smith, L. C.↗

Faraday Cup Array Integrated with a Readout IC and Method for Manufacture Thereof

A detector array and method for making the detector array. The array includes a substrate including a plurality of trenches formed therein, and includes a plurality of collectors electrically isolated from each other, formed on the walls of the trenches, and configured to collect charge particles incident on respective ones of the collectors and to output from said collectors signals indicative of charged particle collection. The array includes a plurality of readout circuits disposed on a side of the substrate opposite openings to the collectors. The readout circuits are configured to read charge collection signals from respective ones of the plurality of collectors.

Bower, Christopher A.↗

Collection Of Charge By Diffusion From Ion Track

Collection of electric charge carriers from track of energetic ion through silicon electronic device studied using diffusion model representing transport of charge from ion track to sink. Effects of ionizing radiation approximated by simple equations.

Edmonds, Larry D.↗

Correlation of ISS Electric Potential Variations with Mission Operations

Orbiting approximately 400 km above the Earth, the International Space Station (ISS) is a unique research laboratory used to conduct ground-breaking science experiments in space. The ISS has eight Solar Array Wings (SAW), and each wing is 11.7 meters wide and 35.1 meters long. The SAWs are controlled individually to maximize power output, minimize stress to the ISS structure, and minimize interference with other ISS operations such as vehicle dockings and Extra-Vehicular Activities (EVA). The Solar Arrays are designed to operate at 160 Volts. These large, high power solar arrays are negatively grounded to the ISS and collect charged particles (predominately electrons) as they travel through the space plasma in the Earth's ionosphere. If not controlled, this collected charge causes floating potential variations which can result in arcing, causing injury to the crew during an EVA or damage to hardware [1]. The environmental catalysts for ISS floating potential variations include plasma density and temperature fluctuations and magnetic induction from the Earth's magnetic field. These alone are not enough to cause concern for ISS, but when they are coupled with the large positive potential on the solar arrays, floating potentials up to negative 95 Volts have been observed. Our goal is to differentiate the operationally induced fluctuations in floating potentials from the environmental causes. Differentiating will help to determine what charging can be controlled, and we can then design the proper operations controls for charge collection mitigation. Additionally, the knowledge of how high power solar arrays interact with the environment and what regulations or design techniques can be employed to minimize charging impacts can be applied to future programs.

Willis, Emily M.↗

CCD advances for X-ray scientific measurements in 1985

A theoretical model is presented which predicts the output response of a CCD to soft X-ray spectra. The model simulates the four fundamental parameters that ultimately limit CCD performance: quantum efficiency, charge collection efficiency, charge transfer efficiency, and read noise. Simulated results are presented for a wide variety of CCD structures, and general conclusions are presented about achieving a practical balance of sensitivity, energy, and spatial resolution for an AXAF instrument. The results of the analysis are compared to an existing state-of-the art CCD and improvements which will be made in the near future are projected.

Janesick, James↗

High Density Faraday Cup Array or Other Open Trench Structures and Method of Manufacture Thereof

A detector array and method for making the detector array. The detector array includes a substrate including a plurality of trenches formed therein, and a plurality of collectors electrically isolated from each other, formed on the walls of the trenches, and configured to collect charged particles incident on respective ones of the collectors and to output from the collectors signals indicative of charged particle collection. In the detector array, adjacent ones of the plurality of trenches are disposed in a staggered configuration relative to one another. The method forms in a substrate a plurality of trenches across a surface of the substrate such that adjacent ones of the trenches are in a staggered sequence relative to one another, forms in the plurality of trenches a plurality of collectors, and connects a plurality of electrodes respectively to the collectors.

Bower, Christopher A.↗

Research investigation of the physical interactions and phenomena associated with hypervelocity sub-micron particles

Signals from impact ionization plasmas were studied as a means of performing microparticle composition analysis. Impact ionization signal response was measured in a time-of-flight (TOF) system for lanthanum hexaboride, carbonyl iron, and aluminum microparticle impacts on a tantalum target, primarily in the 1 - 8 km/s velocity range. Oscilloscope photographs of representative ion TOF signal response are given for each material studied. Graphs and histograms are presented of the total charge collected as well as the charge collected in each observed ion mass group. Data show that ion signals consist primarily of the lower ionization potential elements over the 1 - 8 km/s range.

Roy, N. L.↗

Field Funneling and Range Straggling in Silicon Detectors

Magnitudes of field funneling and range straggling determined in silicon-surface-barrier (Schottky-barrier) charged-particle detectors (SSBD's) through meaurement of charges collected from alpha-particle tracks. Method used extended to straightforward measurement of charge collection from heavy-ion tracks in these and other semiconductor devices. Such measurements used to assess single-event upsets in integratedcircuit chips, with view toward making them resistant to radiation. Field funneling and range straggling measured with electronic system in which charge collected from individual ions measured and recorded by multichannel analyzer.

Zoutendyk, J. A.↗