Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radially resolved active charge exchange measurements of the hydrogenic isotope fraction on DIII-D

Radially resolved hydrogenic isotope fraction measurement capabilities have been developed for DIII-D using the main-ion charge exchange recombination (MICER) spectroscopy system in preparation for mixed hydrogen and deuterium experiments. Constraints on the hydrogenic ion temperatures and velocities based on measurements of the impurity ion properties are required to accurately fit the spectrum. Corrections for cross sectional distortions, spatial smearing due to the halo, and a neoclassical offset between the impurity and hydrogenic toroidal rotation are applied to the constraints prior to fitting the MICER spectrum. Extensive atomic physics calculations have been performed using the FIDASIM code, which has recently been improved to allow simulations using mixtures of hydrogenic species. Overall, these results demonstrate that for the same plasma parameters, the Dα emission is 20%–30% brighter than Hα due to differences in rate coefficients associated with the different ion thermal velocities for the same temperature and therefore must be taken into consideration when calculating absolute densities. However, despite these differences, the absolute error when estimating the hydrogen isotope fraction [n H /(n H + n D )] by using the Hα radiance fraction [L Hα /(L Hα + L Dα )] is typically less than 5% due to the way the fraction is formed, making the radiance fraction a reasonably accurate estimate of the isotope fraction for most cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncertainties in Atomic Data for Modeling Astrophysical Charge Exchange Plasmas

Relevant uncertainties of theoretical atomic data are vital to determining the accuracy of plasma diagnostics in a number of areas, including, in particular, the astrophysical study. We present a new calculation of the uncertainties on the present theoretical ion-impact charge exchange atomic data and X-ray spectra, based on a set of comparisons with the existing laboratory data obtained in historical merged-beam, cold-target recoil-ion momentum spectroscopy, and electron beam ion traps experiments. The average systematic uncertainties are found to be 35–88% on the total cross sections, and 57–75% on the characteristic line ratios. The model deviation increases as the collision energy decreases. The errors on total cross sections further induce a significant uncertainty to the calculation of ionization balance for low-temperature collisional plasmas. Substantial improvements of the atomic database and dedicated laboratory measurements are needed to obtain the current models, ready for the X-ray spectra from the next X-ray spectroscopic mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aligning the Thomson scattering and charge exchange recombination diagnostics using neutral beam emission at DIII-D

This work addresses discrepancies in the alignment of the H-mode pedestal profiles of the electron and ion properties in the DIII-D tokamak as measured by Thomson Scattering (TS) and Charge Exchange Recombination Spectroscopy (CER) diagnostics. While the alignment of these profiles is key for accurate studies of tokamak physics and plasma confinement, misalignments can occur due to inaccuracies, such as in magnetic equilibrium reconstructions required to map measurements in different poloidal and toroidal locations. Both FIDASIM, an established simulation package, and a simplified collisional radiative model are used to simulate neutral beam state densities and neutral beam emission. Simulated neutral beam emissions are calculated based on shifted TS profiles and compared to beam emission measurements from the Main Ion CER system to determine the best shift for aligning TS with CER. This analysis is performed on various DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Doppler back-scattering and charge exchange measurements of E × B plasma rotation in the DIII-D tokamak under varying torque conditions

Measurements of the E × B toroidal angular velocity, $\omega_{E \times B}\,=\,E_\mathrm{r}/RB_\theta$ ($E_\mathrm{r}$ is the radial electric field, B θ is the poloidal magnetic field), are made using the Doppler back-scattering (DBS) and charge-exchange recombination (CER) spectroscopy diagnostics. DBS uses the Doppler shift of wavenumber-resolved density fluctuations while CER uses the Doppler shift of impurity emission lines to independently measure plasma parameters for calculating the local radial electric field. DBS and CER profiles of $\omega_{E \times B}$ as a function of normalized toroidal flux (ρ) are compared at various levels of neutral beam applied torque on the plasma. Under standard neoclassical theory $\omega_{E\times B}$ is a flux surface quantity, making it appropriate to compare across diagnostics. DBS and CER generally show good agreement when comparing $\omega_{E \times B}$ profiles at different levels of neutral beam injection-applied torque. Furthermore, the DBS values have close to the same precision as CER values when averaged over a similar time-scale and effects, such as prompt-torque are considered. DBS is able to observe the rapid ($\lt$10 ms) modification of the $E_\mathrm{r}$ profile by the diagnostic neutral beam 'blips'. This modification is most pronounced when the blip applies a large relative change in torque on the plasma. Overall, these results could have implications on transport analysis and suggests using DBS and CER in conjunction to constrain values of the E × B-shear (sometimes called $\gamma_{E \times B}$).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full-orbit simulations of fast-ion charge-exchange losses induced by neutral particles outside the plasma last closed flux surface

The interaction between neutrals outside tokamak plasmas and fast ions that are generated by neutral beam injection and pass outside the plasma is studied. It is shown that at beam energies (up to ~100~keV) fast-ion losses are significant, up to 20% in the studied case, because of charge exchange reactions between the neutrals and the fast ions. About half of the fast ions that neutralize outside the plasma get lost to the wall while the other half re-enter the plasma and ionize again, often on better confined orbits which is visible as an enhanced beam power deposition in the plasma core (rho ~< 0.7). As a result, the the plasma performance as measured from the beam-thermal neutrons is hardly changed despite the significant fast-ion losses toward the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Gamow-Teller transitions from 59 Co via the 59 Co ⁢(𝑡, 3 He +𝛾) charge-exchange reaction and its application to the stellar electron-capture rates

Electron-capture reactions on iron-group nuclei play a crucial role in the late stages of massive star evolution. Since stellar evolution simulations depend on accurate electron-capture rates—which are highly sensitive to the detailed Gamow-Teller (GT) strength distributions—reliable theoretical models are essential. However, experimental data on GT strength distributions are scarce. High-resolution measurements are therefore vital for benchmarking and improving these theoretical calculations. To provide high-resolution data on Gamow-Teller strength distributions of iron-group nuclei and to compare these results with theoretical calculations within this mass region. Differential cross sections for the 59 Co ⁢(𝑡, 3 He)⁢ 59 Fe charge-exchange reaction at 115 MeV/u were measured using the S800 spectrometer. Furthermore, to resolve individual levels that are not distinguishable in the S800 particle singles data, coincident 𝛾 rays from the 59 Fe residual nucleus were detected by using the Gamma-Ray Energy Tracking In-beam Nuclear Array 𝛾-ray tracking array. Here, the Gamow-Teller transition strength distribution from the ground state of 59 Co to 59 Fe was extracted up to an excitation energy of 10 MeV. Additionally, transition strengths for several low-lying states were determined from coincident 𝛾-ray measurements. Electron-capture rates calculated using the present data indicate that these low-lying states contribute significantly to the overall rates in relevant stellar environments. The experimental results show reasonable agreement with theoretical predictions based on both shell-model and projected shell-model calculations. High-resolution data on Gamow-Teller strength distributions—particularly for individual low-lying states—are essential for accurately determining electron-capture rates in iron-group nuclei. Coincident 𝛾-ray measurements provide a powerful tool for obtaining such detailed information. While the present work demonstrates that shell-model calculations successfully reproduce the experimental results, such comparisons are scarce and more experimental data are desirable.

59 ≤ A ≤ 89↗

Design of a new charge exchange recombination spectroscopy diagnostic for impurity transport experiments at Wendelstein 7-X

In this study, we present the design of a new charge exchange recombination spectroscopy (CXRS) system for Wendelstein 7-X (W7-X), which aims at measuring line radiation from highly ionized iron impurities after laser blow off injections over transport timescales. New fiber bundles with a core diameter of 600 µm have been added to one of the existing optical systems at W7-X used for CXRS. The fibers direct collected light to five newly developed single channel high frame rate F/2.8 spectrometers. The new custom-made spectrometers are built using entirely off-the-shelf and 3D printed components, and employ a round-to-linear fiber bundle, instead of an entrance slit, to maximize light throughput. The detector is an ultra-low readout noise EM-CCD camera capable of frame rates of up to 10 000 fps for about 500 consecutive frames when operated using a single readout channel. Such high frame rates will enable the study of inward convection of injected impurities. An initial sensitivity study is performed using a newly developed Markov chain Monte Carlo approach based on the pySTRAHL impurity transport code. This study indicates that, with the addition of the new CX diagnostic, impurity convection velocities can be inferred.

Instruments & Instrumentation↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

Measurement of Stark-split beam and carbon charge exchange emissions for simultaneous B-field and temperature/rotation analysis at DIII-D

A set of two newly designed, single-channel Czerny–Turner spectrometers has been deployed at the DIII-D tokamak for measurements of the motional Stark effect (MSE) split beam emission and the C6+ (CVI) carbon charge exchange recombination (CER) emission at high spectral (δλ = 0.13 nm) and temporal (1–5 kHz) resolution. High throughput optics (f/# = 2.8) allow for good signal-to-noise at high time resolution using fast EMCCD detectors. The MSE emission allows for spectral fitting of the magnitude and direction of the local B-field, while the carbon emission yields local ion temperature and toroidal rotation information. To reduce so-called Doppler broadening of the MSE emission, a new channel-specific variable lens-masking approach has been developed. Experimental data collected from the 2023 DIII-D experimental campaign demonstrate the signal quality and instrument fidelity for both diagnostic measurements. Moreover, initial CER data analysis shows a clear evolution of the toroidal rotation during edge localized modes. Initial progress on the advanced MSE model, including a new validated ray-trace model of the DIII-D collection optics, is shown via sensitivity analysis.

Instruments & Instrumentation↗

Experimental investigation of H-mode pedestal turbulence using a charge exchange imaging diagnostic system at DIII-D

Microtearing modes (MTMs) (ω ~ ω de k θ ρ s ~ 0.1, k r ρ s ~ 0.3 – 1.0) are predicted to cause substantial electron thermal transport in the H-mode pedestal, limiting fusion performance on high-power devices. Localized 2D measurements of low-to-intermediate wavenumber density fluctuations in the edge of DIII-D H-mode plasmas suggest the presence of temporally intermittent or ‘bursting’ MTMs during the inter-ELM cycle in the steep gradient region. These measurements are obtained using a new intermediate radial resolution multichannel Charge eXchange Imaging (CXI) diagnostic that analyzes the intensity of the CVI emission at 529 nm. The mode is peaked near ρ = 0.97 with a radial full-width half maximum of 1.5–2.0 cm and a normalized density fluctuation amplitude peak of $\frac{dn_C}{n_C}$ ~ 5%, peaking near 60 kHz in the lab frame. The mode additionally features a broad spectral width from 30 to 180 kHz and propagates in the electron diamagnetic direction in the plasma frame. CXI measurements taken during discharges with high density and current ramps provide evidence that MTMs become unstable at finite collisionality and remain at nearly the same location in ρ-space despite scanning of rational surface position. This indicates that the location of the peak in the electron diamagnetic frequency is a stronger driving force than individual rational surfaces.

DIII-D↗

Measurement of the pion charge exchange differential cross section on Argon with the ProtoDUNE-SP detector

The Deep Underground Neutrino Experiment (DUNE) utilizes Liquid Argon Time Projection Chamber (LArTPC) technology in its pursuit of uncovering the origins of matter. As a crucial prototype for the DUNE far detector (FD) module, ProtoDUNE-SP at CERN Neutrino Platform Facility employs a hadron test beam with a momentum range of 0.3 to 7 GeV/c to study the detector response to particles that could be produced in the neutrino interactions at the DUNE FD. Furthermore, ProtoDUNE-SP is dedicated to testing event reconstruction and performing detector calibration under controlled conditions. Neutral pion reconstruction performance is an important benchmark of the calorimetric and tracking capability of LArTPC, and understanding neutral pion in LArTPC is crucial to characterize backgrounds to oscillation measurements and rare searches. To improve neutral pion reconstruction in LArTPC, a kinematic fitting algorithm is developed, achieving a 12% resolution in neutral pion energy in ProtoDUNE-SP. This enhancement enables the first measurements of the pion-argon charge exchange differential cross-section. By comparing these results with the current model, valuable constraints can be made to improve generator simulations in the future DUNE experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A near X-point charge exchange neutral spectroscopy (CENS) system for DIII-D

A 16 channel spectroscopy system has been installed on DIII-D to provide information about the energy distribution of the atomic neutrals using the Doppler shift and broadening of passive Balmer-α emission. Here, the lines of sight are dominantly in the toroidal direction, with tangencies near the lowest point on closed magnetic flux surfaces moving from the lower divertor upward into the confined plasma. This allows the system to provide details of the neutrals as they undergo various atomic physics processes while traveling upward from the lower divertor. The spectrally resolved measurements provide several advantages that complement typical optical filter based measurements of hydrogenic spectral lines. These include more direct measurements of the neutrals that fuel deeper in the plasma and capturing neutral velocity distribution information via the Doppler broadened and shifted line. In addition, the spectral separation of higher energy “thermal” neutrals and bright cold emission from the scrape-off layer allows for a more straightforward calculation of the underlying neutral densities based on the emission because of the dependence of the thermal emission on confined plasma properties that are approximately flux functions and well measured.

Atomic and molecular physics↗