Search NASA⌕ Search

SEARCH · Search NASA

Results for “chilled water system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar energy retrofit for Clarksville Middle School, Clarksville, Indiana

The solar energy retrofit heating system installed to provide heating for two gymnasiums at the Clarksville Middle School located in Clarksville, Indiana is described in detail. The system type is hot water using existing chilled water piping and chilled water coils in an air handler system. Flat plate, single-glazed selectively coated solar collectors were installed on the roof of each gymnasium. Total collector area covers 6,520 square feet. The liquid is stored in a 10,000 gallon steel tank installed below grade.

Source record↗

Application of a run around coil system to a roof fan house at Michoud Assembly Facility at New Orleans, Louisiana

Analysis of the proposed run around coil system indicates that it offers a decrease in steam, electricity and water consumptions. The run around coil system consist of two coils, a precooling coil which will be located at up stream and a reheating coil which will be located at down stream of the chilled water spray chamber. This system will provide the necessary reheat in summer, spring and fall. At times, if the run around coil system can not provide the necessary reheat, the existing reheat coil could be utilized.

Source record↗

Solar-Cooled Hotel in the Virgin Islands

Performance of solar cooling system is described in 21-page report. System provides cooling for public areas including ball rooms, restaurant, lounge, lobby and shops. Chilled water from solar-cooling system is also used to cool hot water from hotel's desalinization plant.

Harber, H.↗

Optimizing mixed cool thermal storage systems across a connected community

A high level of electric demand flexibility must be integrated into our building infrastructure to enable greater renewable energy penetration in the grid. In the U.S., 9% of electricity generated is used to cool buildings in a periodic manner, making this end-use an ideal target for active management through cool thermal energy storage (CTES) technologies. Historic uses for CTES are designed around central chilled water plants, but these systems cool less than 25% of U.S. commercial floorspace. Emerging technologies are under development to serve the many smaller distributed cooling systems, such as rooftop units (RTUs), and have the potential to add CTES to an additional 66% of cooled commercial floorspace. However, these unitary thermal storage systems (UTSS) lack the modeling and analysis tools to evaluate them in the future interactive grid context. Here, this study develops the modeling and optimization tools necessary to simultaneously examine central and distributed ice storage systems within the multi-building, connected community context. An integrated simulation-optimization workflow is created to allow for rapid customized analysis. Results demonstrate the energy and flexibility tradeoffs of various implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

Atmospheric leakage and condensate production in NASA's biomass production chamber. Effect of diurnal temperature cycles

A series of tests were conducted to monitor atmospheric leakage rate and condensate production in NASA's Biomass Production Chamber (BPC). Water was circulated through the 64 plant culture trays inside the chamber during the tests but no plants were present. Environmental conditions were set to a 12-hr photoperiod with either a matching 26 C (light)/20 C (dark) thermoperiod, or a constant 23 C temperature. Leakage, as determined by carbon dioxide decay rates, averaged about 9.8 percent for the 26 C/20 C regime and 7.3 percent for the constant 23 C regime. Increasing the temperature from 20 C to 26 C caused a temporary increase in pressure (up to 0.5 kPa) relative to ambient, while decreasing the temperature caused a temporary decrease in pressure of similar magnitude. Little pressure change was observed during transition between 23 C (light) and 23 C (dark). The lack of large pressure events under isothermal conditions may explain the lower leakage rate observed. When only the plant support inserts were placed in the culture trays, condensate production averaged about 37 liters per day. Placing acrylic germination covers over the tops of culture trays reduced condensate production to about 7 liters per day. During both tests, condensate production from the lower air handling system was 60 to 70 percent greater than from the upper system, suggesting imbalances exist in chilled and hot water flows for the two air handling systems. Results indicate that atmospheric leakage rates are sufficiently low to measure CO2 exchange rates by plants and the accumulation of certain volatile contaminants (e.g., ethylene). Control system changes are recommended in order to balance operational differences (e.g., humidity and temperature) between the two halves of the chamber.

Wheeler, Raymond M.↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Tides on South Mill Apartment Complex

This dataset includes data from the building management system for a large multi-family rental property located in Tempe, Arizona. The name of this rental property is “Tides on South Mill” and it is owned by the FCP which is a real-estate investment company based in Maryland with a large portfolio of rental properties that spreads out throughout the U.S. FCP’s portfolio includes large multi-family housing and commercial buildings. The property is split into four quadrants. Each quadrant has roughly 130 apartments. The total floor area of each Quadrant is about 94,000 sq. ft. The campus of Solara spreads over 27 acres. The mechanical system consists of a 2-pipe system that runs chilled or hot water thru individual Fan Coil Units depending upon the season. The gas-fired boiler will supply hot water when seasonal change-over will take place. This dataset spans October to December 2021 and includes time-series measurements corresponding electricity meter data (Cooling Tower Fan, Pumps, Chillers,) with 1-minute resolution, chilled water temperature data and outside air data with 5-minute resolution etc. as CSV files. In addition to the measurements, a metadata .json file, and a .pdf dataset description file are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

A Flow Rate Dependent 1D Model for Thermally Stratified Hot-Water Energy Storage

Stratified tank models are used to simulate thermal storage in applications such as residential or commercial hot-water storage tanks, chilled-water storage tanks, and solar thermal systems. The energy efficiency of these applications relates to the system components and the level of stratification maintained during various flow events in the tank. One-dimensional (1D) models are used in building energy simulations because of the short computation time but often do not include flow-rate dependent mixing. The accuracy of 1D models for plug flow, plug flow with axial conduction, and two convection eddy-diffusivity models were compared with experimental data sets for discharging a 50-gal residential tank and recharging the tank with hot water from an external hot-water source. A minimum and maximum relationship for the eddy diffusivity factor were found at Re <2100 and >10,000 for recirculation of hot water to the top of the tank and vertical tubes inletting cold water at the bottom. The root mean square error decreased from >4 °C to near 2 °C when considering flow-based mixing models during heating, while the exponential decay of the eddy diffusion results in a root mean square error reduction of 1 °C for cone-shaped diffusers that begin to relaminarize flow at the inlet.

1D flow model↗

The NASA Langley building solar project and the supporting Lewis solar technology program

A solar energy technology program is described that includes solar collector testing in an indoor solar simulator facility and in an outdoor test facility, property measurements of solar panel coatings, and operation of a laboratory-scale solar model system test facility. Early results from simulator tests indicate that non-selective coatings behave more nearly in accord with predicted performance than do selective coatings. Initial experiments on the decay rate of thermally stratified hot water in a storage tank have been run. Results suggest that where high temperature water is required, excess solar energy collected by a building solar system should be stored overnight in the form of chilled water rather than hot water.

Ragsdale, R. G.↗

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

The EGS Collab Project: Status and Accomplishments

The EGS Collab project, supported by the US Department of Energy, is addressing challenges in implementing enhanced geothermal systems (EGS). This includes improving understanding of the stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The project is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory. Data and observations from the field test are compared to simulations to understand processes and to build confidence in numerical modeling of the processes. In Experiment 1, we examined hydraulic fracturing an underground test bed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km. We drilled eight sub-horizontal boreholes in a well-characterized phyllite. Six of the boreholes were instrumented with many sensor types to allow careful monitoring of stimulation events and flow tests, and the other two boreholes were used for water injection and production. We performed a number of stimulations and flow tests in the testbed. Our monitoring systems allowed detailed observations and collection of numerous data sets of processes occurring during stimulation and during dynamic flow tests. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Data were rapidly analyzed, allowing adaptive control of the tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results. Many simulations were performed in near-real-time in conjunction with the field experiments, with more detailed process study simulations performed on a longer timeframe. Experiment 2 will examine hydraulic shearing in a test bed being built at the SURF at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1. Five sets of fracture orientations were considered in design, and three orientations seem to be consistently observed.

EGS Collab↗

Design and performance of Skylab thermal/environmental control system

The function of the thermal/environmental control systems was to provide a comfortable thermal environment for the crew, to cool electronic components, to supply a controlled oxygen/nitrogen atmosphere, and to remove moisture, carbon dioxide, odors, and trace contaminants from the atmosphere. A separate refrigeration system was used to chill and freeze food and biomedical samples and to provide cold water for drinking. This paper describes system design and compares in-flight performance to preflight predictions. A discussion of in-flight anomalies and corrective actions is also included.

Hopson, G. D.↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗